INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
1. Introduction
The lyriQ™ High Performance Keypad Volume Control with IR, P/N AU1000-xx
(see Figure 1), is an integral part of the lyriQ™ Multi-Room Audio System. It is
a component which, when combined with other essential components and your
source equipment (receiver, CD player, etc.), creates a versatile whole-house
audio system that will fill your rooms with high-quality sound for years to come.
It uses Category 5 wiring to distribute audio signals, control information and IR
for remote control. The High Performance Keypad has two on-board 20 Watt
per channel class D amplifiers to provide a rich level of clean sound even in
outdoor or large room applications. It also contains a full set of features,
including the integrated ability to control all other keypad volume controls in the
house.
2. Description
The front panel of the lyriQ™ High Performance Keypad Volume Control with IR,
PN AU1000-xx (see Figure 1), looks almost identical to the standard lyriQ™
Keypad Volume Control with IR (F7394-xx). It also has push buttons for
VOLUME UP/DOWN (with five associated green Volume Bar Graph LEDs),
SOURCE (with four green Source Selection LEDs) and MUTE (with one red
status LED). There is also an IR target window and tri-colored status LED. The
visual cue from the front panel that this is a High Performance Volume Control
are the parenthesis surrounding the music note in the lower right hand corner.
You’ll have no problem telling that this is a lyriQ™ High Performance Keypad
Volume Control from the rear of the keypad (see Figure 2). The first thing you’ll
notice is that the Category 5 connection is now an RJ45 jack (J1) rather than a
110 style punch down strip. The TB2 speaker output connections (left and right,
plus and minus) are spring loaded and designed to support up to 14 gauge wire.
The TB3 Line Out connections (plus and minus) are also spring loaded and
designed to support up to 14 gauge wire. This mono-summed output is designed
for powered sub-woofers and as such is filtered through an 80Hz low pass filter.
The other terminal block on the rear (TB1) is used for powering the keypad. Up to
14 gauge speaker wire may be used for this purpose, and this speaker wire (two
conductor or four conductor) is run from a power distribution module (P/N
AU1001) in the enclosure to the volume control. We recommend 16/4 speaker
wire, since it is available paired with Category 5 from a variety of sources. Again,
the TB1 connections are spring loaded (plus and minus) with the two plus
connections on the red portion of TB1 and the two minus connections on the
black portion of TB1. For ease of installation, connect the red wire and white wire
to the red (plus) portion of TB1 and the black and green wire to the black (minus)
portion of TB1.
Figure 1
Figure 2

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 2 of 6
INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
3. Installation
Installation of the lyriQ™ High Performance Keypad Volume Control with IR is best accomplished at multiple times
during new construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed
and painted.
NOTE: Before connecting the volume controls: Make sure that power supplies are not connected to the
lyriQ™ Audio and Power Distribution Modules. For instructions on pre-wiring and installing other
components of the lyriQ™ Audio System, please see the Instruction Sheets included with those
components.
NOTE: All wiring should be terminated to the T568A wiring standard. Failure to follow the correct wiring
standard could result in damaged equipment.
A. “Rough-in” steps:
1) A single Category 5 cable and 16/4 speaker wire should be run from the enclosure location to a single
gang outlet box or mud ring at each Volume Control location.
B. “Trim-out” steps:
1) Connect the volume control by terminating the pre-wired Category 5 cable from the enclosure with an
RJ45 plug, following the T568A wiring standard and insert this plug into jack J1 (see Figure 2).
2) For the power connection (TB1) strip 3/8” of insulation from each of the four conductors and insert the
red and white wires into the red (plus ) portion of TB1. Insert the stripped black and green wires into the
black (minus) portion of TB1 (see Figure 2).
NOTE: The two red connections are tied together, as are the two black connections. They are
provided in pairs to provide flexibility of wiring.
NOTE: Electricians may prefer to think of the black and red wires as plus and the green and white
wires as minus. That wiring will also work, as long as it is also followed at the other end of the cable
(at the Power Distribution Module in the enclosure).
3) Speaker/Line Out/Sub-Woofer connections (see Figure 2):
NOTE: Polarity and channels are clearly marked (L+, L-, R-, R+) for proper identification during
installation.
a) Use TB2 to connect your evōQ™ audio speakers to the volume control.
b) Use TB3 to connect your evōQ™ powered sub-woofer or an external amplifier to the volume control.
These connection terminals do not provide any amplification but the volume control on the keypad
controls the output level of this connection.

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 3 of 6
INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
4) Connections in the enclosure (see Figure 3 ):
a) The Category 5 cable that was run to each volume control location should be terminated with an RJ45
plug according to the T568A wiring standard and inserted into one of the zone output jacks of the
associated lyriQ™ audio distribution module.
b) For the 16/4 speaker wire power cable that was run to each volume control location, strip 3/8” of
insulation from each of the four conductors and insert the red and white wires into the red (plus ) portion
of TB1. Insert the stripped black and green wires into the black (minus) portion of TB1
NOTE: As noted before, Electricians may prefer to think of the black and red wires as plus and the
green and white wires as minus. That wiring will also work, as long as it is also followed at each
end of the cable.
5) Keypad Mounting: check all connections and test the system’s operation before installing the volume
controls into the wall. Use the included screws to install the volume control and wall plate into a standard
single gang box.
NOTE: If not using a low voltage mounting ring, a 20 in.³ or greater single gang box is recommended.
Figure 3

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 4 of 6
INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
4. Operation
A. ON/OFF:
Keypad – Press any button for ON / Press and hold MUTE
button for OFF (see Figure 4).
Remote – Press POWER button to toggle ON or OFF (see
Figure 5).
B. SOURCE select:
Keypad – Press SOURCE button multiple times (see Figure 4).
Remote – Press SOURCE 1, 2, 3, or 4 button (see Figure 5).
NOTE: Upon source change, volume ramps down and then
back up automatically.
C. Volume Steps: Keypad or Remote – Press VOLUME UP or DOWN button
(40 steps).
D. Mute: Keypad or Remote – Tap MUTE button.
E. Back Light Level Adjust:
Keypad – Press and hold VOLUME UP and DOWN buttons simultaneously. The
button back lights will flash to indicate they may be adjusted. Press VOLUME UP
or DOWN button to adjust back light level. Press SOURCE or MUTE button to exit
or wait for 10 second time out (see Figure 4).
NOTE: When any Keypad button is tapped, back light level goes to full bright and
returns to the adjusted level when activity ceases. For Remote operation, the
back light goes to full bright when an IR command is received and returns to the
adjusted level when activity ceases.
F. Temporary Do Not Disturb (DND):
Keypad – Double tap MUTE button, Status/IR LED glows dim RED (see
Figure 4).
NOTE: When Keypad is in temporary DND mode, it will NOT respond to whole
house commands from other locations. Press any button to disable temporary
DND mode.
G. Whole-House Source Control/Party Mode (see Figure 4):
NOTE: In this mode, every operation performed on this keypad will be relayed
to all keypads in the system (like Whole House Mode on the Remote).
Keypad – Press the MUTE and SOURCE buttons simultaneously and the IR/Status LED should blink orange.
Figure 4
Figure 5
Source
LEDs
Source
Button
Mute
Button
Volume
Buttons/
LEDs
IR
Target
Status
LED
Power
Button
Source
Buttons
Volume
Buttons
Mute
Button

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 5 of 6
INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
NOTE: The other keypads that are on and not in DND mode momentarily flash their Volume Bar Graph LEDs
(indicating they are under Whole House control). Their IR /Status LED also blinks orange.
In this mode, all functions performed on the local keypad such as Volume Up/Down, Mute, Source selection, or
Power Up/Down are relayed to and performed on all active keypads in the system.
NOTE: There are also two special SOURCE commands that may be issued In this mode as described
below.
1) When in Whole-House Source Control Mode and the SOURCE button is pressed and held, a command will
be issued for all keypads to turn on and go to the selected source.
2) When in Whole-House Source Control Mode and the SOURCE button is double tapped, a command will be
issued for all active keypads to go to the source that the local keypad is currently on. This is handy to get
everyone sync’d to the same source without going through all the selections. Remember, if I’m listening to a
source let’s say #3 for example and want to perform Whole House commands to get everyone else there, if I
simply go into Whole-House Source Control mode and press the SOURCE button it will cause everyone to
go to #4 and then #1 and then #2 and finally to #3, while double tapping it will cause every active keypad to
go directly to Source #3.
NOTE: The Whole-House Source Control mode will be exited when the user fails to press a key
within 10 seconds or by pressing and holding the MUTE and SOURCE buttons simultaneously as
before.
5. Important Safety Precautions:
READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING THE lyriQ™ AUDIO SYSTEM.
• Do not attempt to service, move or change any component of this system unless you are qualified to do so.
• This system should be installed by a qualified installer and must conform to all local building and electrical codes.
• Do not apply power to the lyriQ™ Audio System until all components have been installed and all wiring has been properly
terminated.
• Do not attempt to terminate, change or un-install any wiring without first turning off power at the lyriQ™ Audio System which
is located in the enclosure. Unplug the power transformer/s that is/are powering the lyriQ™ Audio System from the power
outlet before proceeding with wiring terminations or changes.
• Install each component of this system away from heat sources such as HVAC ducts/registers, stoves or any other heat
source.
• Do not expose any component that was designed for indoor use to moisture. Doing so can create electrical hazards or
render the component unusable. Exposure to moisture will also void the warranty on the system.
• Only use a damp cloth to clean the cover plates of the system components. Do not use vacuum cleaners, liquid or aerosol
cleaners.

301 Fulling Mill Road, Suite G
Middletown, PA 17057
Phone (800) 321-2343 / Fax (717) 702-2546
www.onqlegrand.com
Page 6 of 6
INSTRUCTION/INSTALLATION SHEET
lyriQ™ High Performance Keypad
V
olume Control With IR
IS-0369 REV. O
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
6. Installer Configuration
A. Installer Mode (see Figure 4):
Keypad – Press and hold all four buttons (VOLUME UP, DOWN, MUTE and SOURCE) for @ 5 seconds (Status
LED will continually flash green then red while in Installer Mode).
1) Permanent DND – Press SOURCE to light LED #1
NOTE: With Source LED #1 lit, Press VOLUME buttons to adjust permanent DND (Volume Bar Graph LED
#1 ON = DND enabled or Volume Bar Graph LED #2 ON = DND disabled).
2) Turn On Volume – Press SOURCE to light LED #2
NOTE: With Source LED #2 lit, Volume Bar Graph lights indicate Turn On Level. Press VOLUME buttons
to adjust. If Volume is adjusted all the way up (bottom three LEDs lit) and you keep pressing VOLUME
UP, the top LED and bottom LED only will light = Turn On to last volume level.
3) Maximum Volume – Press SOURCE to light LED #3
NOTE: With Source LED #3 lit, Press VOLUME buttons to adjust maximum volume level. The user will
then not be able to exceed this volume level.
4) IR Receiver Adjust – Press SOURCE to light LED #4
NOTE: With Source LED #4 lit, Press VOLUME buttons to adjust IR functionality. Volume Bar Graph LED
#1 ON = Normal IR functionality. Volume Bar Graph LED #2 ON = IR output disabled (Remote controls
only this volume control). Volume Bar Graph LED #3 ON = IR Target disabled (useful for ganged volume
controls – may not want to control volume of outside speakers along with inside speakers).
5) Balance – Press SOURCE to light LED #1 and LED #2
NOTE: With Source LED #1 and #2 lit, Center Volume Bar Graph LED is On. Press VOLUME buttons to
adjust left/right balance.
6) Back Light Mode – Press SOURCE to light LED #1 and LED #3
NOTE: With Source LED #1 and #3 lit, Press VOLUME buttons to adjust Back Light Mode (Volume Bar
Graph LED #1 ON = Back Light ON or Volume Bar Graph LED #2 ON = Back Light OFF).
7) Default Settings – Press SOURCE to light LED #1 and LED #2 and LED #3 and LED #4
NOTE: With Source LED #1 and #2 and #3 and #4 lit, Press VOLUME UP or DOWN button to reset the
volume control to factory default settings.
B. Firmware Version (see Figure 4):
Keypad – With the volume control on, press the following sequence: MUTE, VOLUME DOWN, VOLUME UP,
VOLUME UP – repeat 3 times.
NOTE: After pressing this sequence, the current firmware revision will be displayed on the Source LEDs
and Volume Bar Graph LEDs. For example, if we are at firmware revision 1.1, Source LED #1 and the
bottom Volume Bar Graph LED will be lit.
Table of contents