Model
GSI-152
Rated capacity
1000W 3000W 4000W 5000W 6000W
Input Voltage
(170-265)VAC
Frequency
45-65Hz
Voltage
AC220V+2%(Battery mode)
Output
Frequency
50/60Hz+1%(Battery mode)
Output wave form
Pure sine wave
Efficiency
>87%
Battery
Optional
Battery rated voltage
12/24/48VDC 24/48/96VDC
Protection
Transform
Interactive
Overload
Communication
RS-232
Temperature
-20-+75℃
Environ-
ment Humidity
Product Size L*W*H(mm)
Weight(N.W.) (kg)
GSI-202
2000W
0--35A(Optional)(96V Max.15A)
10%-90%
475*270*205mm
640*270*205mm
12kg 15.3kg
16.8kg
24kg
26.5kg
31.5kg
GSI-302 GSI-402 GSI-502 GSI-602
Max AC charging current
11 12
Switch off with loads
Terminal heating
Switch on failure
Alarm when switch
on
Ⅷ. Convenient method of maintenance & fixing:
Fault
Battery no energy or overload
Fault connection with city power
or battery
Fault or loose connection
Recoverable fuse popup
Battery no energy or overload
Cause
Press fuse back
Fasten again
Charge battery or reduce loads
Check connection with battery or
connect again
Charge battery or reduce loads
Solution
Buzzer scream 2 secs
every 1 sec stop
Over temperature alarm (85 alarm-90
shut down) Check if fan heat dissipation hole jammed
Fan twirls sometimes
fast as well as slowly
Fan twirls fast when inside temperature
reaches 45 degree, twirls slowly when 42
degree
Normal phenomenon, fan is under intelligent
control
No city power input
Ⅶ. Care and maintenance
1). This series of products seldom need to be fix. The standard model battery is
like a adjusting tap. Low maintenance, ensuring better life only by charging
often. When connecting to mains supply, no matter whether the inverter is on
or not, it still keeps charging for battery, and provides over charge, over
discharge protection.
2). If there has been long time no using the inverter, it would be better to charge
on after four to six months.
3). The normal working life of battery is 3 or 5 years, if it doesn’t work, please
change as early as possible by professionals.
4). Don’t change the single battery , changing the battery should according to
the suppliers instructions.
5). In normal, the battery should discharge then recharge after working each four
or six months , start to charge and finish discharge, standard charging time
should be more than 12 hours.
6). In high temperature area, the battery should be charged and discharged
every 2 months and the standard charging time is more than 12 hours.
Note:
1). Before changing battery, must turn off inverter and disconnect the
mains supply.
2). Remove metal object like ring, watch etc.
3). Please don’t put the metal objects on the battery.
4). It is a normal phenomenon that the wire will appear a small spark when
connecting to the inverter, but it will not does harm to the people or the
inverter.
5). Be attention to do not reverse connecting between the positive pole and the
negative pole.
If connected to the generator, the following steps should be required.
1).To start the generator till it runs steadily, then connect the generator output to
the inverter input terminal. And turn on the inverter step by step according to
the operating instruction. After the inverter starts, connect the load one by one
to the inverter.
2).Please select the inverter capacity two or three times over than the
capacity of the generator.
Ⅸ. Technical Data
Overload, short circuit, battery high and low voltage and AC input high and low voltage protection
110%~120% turn to bypass after 30secs, 160%maintain 300ms and then shut down
Above parameter revision change without notification.