Onkyo TX-RZ830 User manual

Service Manual
Published by Onkyo & Pioneer Corporation Global CS Department 2018
Ref.No. : 4799
TX-RZ830
11.2ch AV Receiver
Final Issue
Final Issue
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Model Color Type Power Requirement Remarks
TX-RZ830 (B) – Black MDC AC 120 V Canada/USA/(Mexico)
TX-RZ830 (B) – Black MMP AC 220 V to 240 V Europe
TX-RZ830 (S) - Silver MMP AC 220 V to 240 V Europe
TX-RZ830 (B) – Black MMB AC 220 V to 240 V UK
TX-RZ830 (B) – Black MMR AC 220 V to 240 V China
TX-RZ830 (B) – Black MMA AC 220 V to 240 V Australia/New Zealand
For details, refer to "Important Check Points for good servicing".

543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Service Notes
Important Check Points for Good Servicing
In this manual, procedures that must be performed during repairs are marked with the below symbol.
Please be sure to confirm and follow these procedures.
1. Product safety
Please conform to product regulations (such as safety and radiation regulations), and maintain a safe servicing environment by following the safety instructions described in this manual.
1 Use specified parts for repair.
Use genuine parts. Be sure to use important parts for safety.
2 Do not perform modifications without proper instructions.
Please follow the specified safety methods when modification(addition/change of parts) is required due to interferences such as radio/TV interference and foreign noise.
3 Make sure the soldering of repaired locations is properly performed.
When you solder while repairing, please be sure that there are no cold solder and other debris.
Soldering should be finished with the proper quantity.
4 Make sure the screws are tightly fastened.
Please be sure that all screws are fastened, and that there are no loose screws.
5 Make sure each connectors are correctly inserted.
Please be sure that all connectors are inserted, and that there are no imperfect insertion.
6 Make sure the wiring cables are set to their original state.
Please replace the wiring and cables to the original state after repairs.
In addition, be sure that there are no pinched wires, etc.
7 Make sure screws and soldering scraps do not remain inside the product.
Please check that neither solder debris nor screws remain inside the product.
8 There should be no semi-broken wires, scratches, melting, etc. on the coating of the power cord.
Damaged power cords may lead to fire accidents, so please be sure that there are no damages.
If you find a damaged power cord, please exchange it with a suitable one.
9 There should be no spark traces or similar marks on the power plug.
When spark traces or similar marks are found on the power supply plug, please check the connection and advise on secure connections and suitable usage.
Please exchange the power cord if necessary.
10 Safe environment should be secured during servicing.
When you perform repairs, please pay attention to static electricity, furniture, household articles, etc. in order to prevent injuries.
Please pay attention to your surroundings and repair safely.
2. Adjustments
To keep the original performance of the products, optimum adjustments and confirmation of characteristics within specification.
Adjustments should be performed in accordance with the procedures/instructions described in this manual.
Also, No Adjustments should be performed in accordance without the procedures/instructions described in this manual, such as the tuner pack.
3. Lubricants, Glues, and Replacement parts
Use grease and adhesives that are equal to the specified substance.
Make sure the proper amount is applied.
4. Cleaning
For parts that require cleaning, such as optical pickups, tape deck heads, lenses and mirrors used in projection monitors, proper cleaning should be performed to restore their performances.
オンキヨー
インテグラ

5 4 3
2
1 6
D
C
A
B
D
C
A
B
5 4 3
2
1 6
COMMON
Service Notes
Service Notes
1. Safety-related component warning!!
Components identified by mark on the schematic diagram and by mark “!” in the parts list are critical for risk of fire and electrical
shock. Replace these components with ONKYO parts whose part numbers appear as shown in this manual.
2. Safety check after servicing
(1) To ensure safety, check that the covered insulating sheet or tube are removed, all parts and wires which are removed or
disconnected while servicing have been put back to their original positions after servicing.
(2) To insure structural integrity, check that all the screws or mechanical parts have been put back in their original positions after
servicing.
(3) Check that in the process of servicing or replacing parts that the surrounding area has not been contaminated or adversely affected.
(4) After servicing an insulation check on the external metal connectors and between the blades of the power plug must be performed.
Method of checking insulation resistance
Unplug the power cord and short the both ends of the plug with a jumper wire.
Using a 500V insulation resistance tester, check that the insulation resistance value between the plug of the power cord
and externally exposed metal parts is 1MΩ or greater.
※The mechanical power switch should be turned on if it is available.
3. Caution on replacing the battery
Danger of explosion if rechargeable batteries is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. When disposing of used batteries, please comply with governmental regulations or environmental public institution’s rules
that apply in your country / area.
4. Other Cautions
・When AC plug is non-polarized and if Main or Primary fuse enters in the Neutral line of AC Mains supply or if there is possibility of Main
or Primary Fuse entering in the Neutral line of AC Mains supply, then AC Mains supply must be disconnected to de-energize the circuit.
・Be sure to use only lead free solder.
・When soldering, please be careful not to use too much solder and affect adjacent components.
・When you repair the CD Player, Please do not stare into the beam in Optical Instruments and do not view directly since there is visible
and invisible laser radiation when open the unit.
This service manual is intended for qualified service technicians; it is not meant for the casual do-it-yourselfer.Qualified technicians have the necessary test
equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the
repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.

543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Note for Parts List
D AC 120 V
G AC 220 V to 230 V
H AC 220 V to 230 V / 240 V
J AC 100 V
M AC 220 V to 240 V
P AC 230 V
U AC 100 V to 240 V
V AC 110 V to 240 V
W AC 120 V / 220 V to 240 V
Z ※1
Speaker System (without AMP.) :
0 Passive Subwoofer
F Front Speaker
C Center Speaker
R Rear Speaker
B Back Speaker
A Australia
B United Kingdom
C North American
D USA
F Taiwan
J Japan
K Korea
L Russia
P Europe
Q Hong Kong
R China
S Brazil
T Thai
U Worldwide
Speaker System (without AMP.) :
L Left channel
R Right channel
0 Center channel
When parts list is EXCEL file, please refer to the following explanation about file name.
P L _ T X –S R 3 4 3 ( B ) M J J . x l s x
(X) Not related to color
(B) Black (M) Wood
(BR) Brown (O) Orange
(C) Cream (P) Pink
(G) Gold (R) Red
(GR) Green (S) Silver
(H) Gray (T) Titan
(K) Black (V) Violet
(L) Blue (W) White
(LB) Light Blue (Y) Yellow
Look at the rear panel serial number 6 digit.
○○○○○J○○○○○○○○○○
Look at the rear panel serial number 5 digit.
○○○○J○○○○○○○○○○○
File Name of Parts List File (EXCEL File)
※1 There is a charge function and a power supply (adapter) is needed, but an adapter isn't bundled.

543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6
TX-RZ830
Panel
Front Panel
Rear Panel
Remote Control Unit
Accessory
Panel
RC-911R
Dimensions (W ×H ×D) : 435 mm ×201.5 mm ×398 mm (17-1/8" ×7-15/16" ×15-11/16")
Weight : 14 kg (30.9 lbs.)
1. Remote controller (RC-911R) (1)
2. Batteries (AAA/R03) (2)
3. Speaker setup microphone (1)
4. Indoor FM antenna (1)
5. AM loop antenna (1)
6. Power cord (1)

5 4 3
2
1 6
D
C
A
B
D
C
A
B
5 4 3
2
1 6
TX-NR585/NR686/NR787
TX-RZ630/RZ730/RZ830
DRX-3.2/4.2/5.2
Reset
【STORE】
[ SETUP ] + [ ENTER ] x 2
【RESET】
1. [ CBL/SAT ] + [ STANDBY ]
2. Unplug the power cord from AVR after the disappeared "Clear"
of FL tube and AVR goes standby.
【RECALL】
[ SETUP ] + [ RETURN ] x 2
Detail Key Operation is here.
Reset

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Protect Mode
The unit goes into standby automatically when detect the abnormal condition of thermal detection, dc voltage detection or current detection. (e.g. TX-NR555 block diagram below)
BACLA PCB
Info
BAAF PCB Info
BAETC
PCB Info
BAPS PCB Info
BAPRC PCB Info
MPU
Q7009
VOLTAGE
DRIVE
RELAY
RL6501
(FL/FR)
Power amp.
(Front L)
Q6001
Q6021
SPRLF
THERMAL
DETECT
Q6800
POWER
TRANS.
T901
CURRENT
DETECT
Power
Supply
AC IN
PON_MAIN PON_MAIN
Relay
RL9001
FUSE
F9002 SEC-1
(HIGH)
SEC-1
(LOW) FUSE
F6901
F6902
RELAY
RL6911
RL6912
Power
Supply
(H)
(L)
(H)
or
(L)
SEC1H
IPRO
DC
DETECT
VPRO
IPROTECT
VPROTECT
VOLTAGE
DETECT
VOLH
VOLH
THERMAL
P6800A
P9002
P8002
P2800B
SUB
TRANS. Power Supply
for STANDBY VPRO: DC voltage detection
IPRO: Current detection
SPEAKER - OUT

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
PCB Information
BAPRC BAAF BAETC BAPS
TX-NR585 BAPRC-2409 TX-NR585 BAAF-1979 TX-NR585 BAETC-1980 TX-NR585 BAPS-1984
TX-NR686 ↑TX-NR686
↑TX-NR686 ↑TX-NR686 ↑
TX-NR787 BAPRC-2605 TX-NR787 BAAF-2597 TX-NR787 BAETC-2598 TX-NR787 BAPS-2557
TX-RZ630 ↑TX-RZ630 ↑TX-RZ630 ↑TX-RZ630 ↑
TX-RZ730 ↑TX-RZ730 ↑TX-RZ730 ↑TX-RZ730 ↑
TX-RZ830 ↑TX-RZ830 ↑TX-RZ830 ↑TX-RZ830 BAPS-2585
DRX-3.2 ↑DRX-3.2 ↑DRX-3.2 ↑DRX-3.2 BAPS-2562
DRX-4.2 ↑DRX-4.2 ↑DRX-4.2 ↑DRX-4.2 ↑
DRX-5.2 ↑DRX-5.2 ↑DRX-5.2 ↑DRX-5.2 BAPS-2594
BACLA BATRM
TX-NR585 BACLA-1988 TX-NR585 BATRM-2023
TX-NR686 ↑TX-NR686
↑
TX-NR787 BACLA-2559 TX-NR787 BATRM-2601
TX-RZ630 ↑TX-RZ630 ↑
TX-RZ730 ↑TX-RZ730 ↑
TX-RZ830 BACLA-2587 TX-RZ830 ↑
DRX-3.2 BACLA-2568 DRX-3.2 ↑
DRX-4.2 ↑DRX-4.2 ↑
DRX-5.2 BACLA-2596 DRX-5.2 ↑

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Self-diagnostics
This function is for avoiding the rupture of electrolytic capacitors with amplifier circuit
failure during power-ON.
Operation of Self-diagnostic
Self-diagnostic will start at the timing of next power on, after goes to the protect mode
by Current detection or DC voltage detection.
Only On/Standby key could work in this mode. Also remote control does not work.
However, the CLEAR operation is enabled.
During Self-diagnostic, the power supply for amplifier circuit become low voltage
state(SEC1-LOW), and the speaker relay will be turned off. Then, MPU will check each
amplifier circuits Internally by entering the test signal (20 kHz,-20 dBFS sine wave) to
each channel from DSP.
MPU will judge the amplifier circuit is good or not from VOLH value.
The normal range of VOLH value is 0.04 V < VOLH < 0.20 V.
If VOLH value is in the out of this range, it will be judged as NG (No good).
No problem found
When protected by current detection, and no problem found, "CHECK SP WIRE“ will be displayed.
In this State, Only the On/Standby key is effective. And if do not anything for 3 minutes, unit goes
into standby automatically.
When protected by a DC voltage detection, and no problem found, unit goes into normal
operation.
Problem found
When judged as there is a problem on any channel, the information of channel that has a problem
will be displayed as in the right figure.
In this State, Only the On/Standby key is effective. Also remote control does not work. If do not
anything for 3 minutes, unit goes into standby automatically. This state will keep also after unit
turn on/off, or AC unplugged.
the power supply for amplifier circuit become low voltage state(SEC1-LOW), and the speaker
relay will be turned off.
Display of during Self-diagnostics
A M P D i a g M o d e
2 Line FL tube type
“Mode” This part display the channel which is currently checked. (E.g. "[FL]", etc.)
A M P D i a g M o d e
1 Line FL tube type
Display of when problem found
N G C H :
L C R S L S R B L B
R
N G : L C R S L S R B L B R
2 Line FL tube type
1 Line FL tube type
L
C
R
S L
S R
B L
B R
Front L channel
Center channel
Front R channel
Surround L channel
Surround R channel
Surround back R channel
Surround back L channel

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Repair Process and How to Confirm
Confirmation of the protect cause
While NG channel is displayed, You can confirm the protect cause by following the step below.
1. Press the Enter button
2. The protect cause are displayed for 5 seconds.
Please check the around of those amplifier circuit and repair it.
Clear of NG CH information
After repair, you can clear NG CH information by following the steps below.
1. Press the On/Standby key while pressing the Enter key.
2. Display as in the right figure appears.
3. Unit goes into Standby automatically after 5 seconds.
Self-diagnostic will start again at the timing of next power on.
By this, You can verify whether repair was properly or not.
If problem found after repair, please re-check the around of its circuit.
Cancel of Self-diagnostic
You can cancel this mode by clear operation (press Standby key while pressing CBL/SAT key).
After cancel this mode, receiver will be started as normal operation.
Manual Execution of Self-diagnostic
1. [DIMMER] + [ON/STANDBY] x 2
Main Firmware Version will appear on the main unit’s display.
2. [SETUP] or [HOME]
Service Menu will appear on the main unit’s display
3. Setup & select channel for self-diagnostic by enter service mode to “AMPChDiag”
Display as in the right figure appears. Select channel by cursor Left & Right.
4. [STANDBY/ON]
Unit will go into standby.
5. [STANDBY/ON]
Unit will turn on. Then self-diagnostic will start automatically.
Protected by current detection
Protected by DC Voltage detection
D E T . P R O T E C T : I
D E T . P R O T E C T : V
N G C H C L E A R
Clear of NG CH information
A m p C h D i a g : O f f
Manual Execution of Self-diagnostic

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
How to enter to service mode.
Step1 :
[DIMMER] + [ON/STANDBY] x 2
Step2 :
[SETUP] or [HOME]
Step3:
Follow this Tree operation for each service mode.
Displaying Service information
This service informationdisplay system is helpful in analyze the status when the unit goes into
Protect mode and is powered off. Pay attention that the status will change if a button is pushed.
Follow this Tree for “ProtectData” section at the “1-1 Tech Sprt”
Step1 :
When the [ENTER] button is pressed, It will show error history
Step2:
When the [ENTER] button during display error history,
the additional information of error history will be appeared.
How to change History No. 1 ~ 3.
[CURSOR LEFT] or [CURSOR RIGHT]
How to exit the service mode.
Please press the [ANY INPUT SELECTOR]
How to clear Protect Data
Step1:
Select “ProtectDataCLR” from this tree
Step2:
Press [ENTER] button
After display “DATA Cleared!”, It will be data reset and go to normal mode.
Enter Service mode, Service Information
[CUROR LEFT] [CURSOR RIGHT]
[CURSOR LEFT] [CURSOR RIGHT]
Normal display
M1.xx / xxxxxAEx The version of main microprocessor.
(displayed only for 3 seconds)
1. Service
Protect Data CLR
1 01: 23 10h
2 01: 47 8h
3 00: 00 00h
1 I 8 0 F 3 0 D D
2 I 9 1 F 2 7 D D
3 -0 0 F 0 0 A
T : 0 I : 2 V : 0 No Use
T : Thermal Protect
[ENTER]
Count of each protect
I : Current Protect
V : Voltage Protect
1 I 8 0 F 3 0 D D
History No.
: 1 ~ 3
(1 is latest.)
PROTECT
I: Current Protect
V: Voltage Protect
T: Thermal Protect
Tempe-
rature Volume
Value Listening Mode
See This value
1 01: 23 10h Information Displayed
(Record this Information)
Time after Power on
xx : xx Cumulative operation time after Reset
: xx h
History No.
: 1 ~ 3
(1 is latest.)
Clear:[ENTER]
DataCleared!

Diagnostic Function
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Listening Mode Code List
Service Information
00
NORMAL_LMD_BEGIN
01
LAST
02
PURE
03
DIRECT
04
STEREO
05
MONO
06
ORCHESTRA
07
UNPLUGGED
08
STUDIOMIX
09
TVLOGIC
0A
ALLCHST
0B
FULLMONO
0C
TD
0D
RPG
0E
ACTION
0F
ROCKBAND
10
SPORTS
11
WHOLEHOUSE
12
RPG_GENRE
13
ACTION_GENRE
14
ROCKBAND_GENRE
15
SPORTS_GENRE
12
NORMAL_LMD_END
20 SURR_LMD_BEGIN
21 SURR_20_PLII_MOVIE
22 SURR_20_PLII_MUSIC
23 SURR_20_PLII_GAME
24 SURR_20_PLIIX_MOVIE
25 SURR_20_PLIIX_MUSIC
26 SURR_20_PLIIX_GAME
27 SURR_20_PLIIZ
28 SURR_20_NEO6_MOVIE
29 SURR_20_NEO6_MUSIC
2A SURR_20_NEURAL_MUSIC
2B SURR_20_NEURAL_CINEMA
2C SURR_51_OFF
2D SURR_51_MTR
2E SURR_51_DSC
2F SURR_51_NEO6
30 SURR_51_EX
31 SURR_51_PLIIX_MOVIE
32 SURR_51_PLIIX_MUSIC
33 SURR_51_PLIIZ
34 SURR_51_NEURAL_CINEMA
35 SURR_20_NEOX_CINEMA
36 SURR_20_NEOX_MUSIC
37 SURR_20_NEOX_GAME
38 SURR_51_NEOX_CINEMA
39 SURR_51_NEOX_MUSIC
40 SURR_51_NEOX_GAME
41 SURR_20_DOLBY_SURR
42 SURR_51_DOLBY_SURR
43 SURR_LMD_END
48 DTSSS_LMD_BEGIN
49 DTSSS_20_NEO6_MUSIC
4A DTSSS_20_NEO6_CINEMA
4B DTSSS_51
4C DTSSS_LMD_END
50
THX_MUSIC_LMD_BEGIN
51
THX_20_PLII_MUSIC
52
THX_20_PLIIX_MUSIC
53
THX_20_PLIIZ_MUSIC
54
THX_20_NEO6_MUSIC
55
THX_20_NEURAL_MUSIC
56
THX_51_OFF_MUSIC
57
THX_51_MTR_MUSIC
58
THX_51_DSC_MUSIC
5A
THX_51_PLIIX_MUSIC
5B
THX_51_PLIIZ_MUSIC
5C
THX_51_NEO6_MUSIC
5D
THX_51_NEURAL_MUSIC
5E
THX_20_NEOX_MUSIC
5F
THX_51_NEOX_MUSIC
60
THX_20_DOLBY_SURR_MUSIC
61
THX_51_DOLBY_SURR_MUSIC
62
THX_MUSIC_LMD_END
70
THX_GAME_LMD_BEGIN
71
THX_20_PLII_GAME
72
THX_20_PLIIX_GAME
73
THX_20_PLIIZ_GAME
74
THX_20_NEURAL_GAMES
75
THX_51_OFF_GAMES
76
THX_51_MTR_GAMES
77
THX_51_DSC_GAMES
78
THX_51_PLIIX_GAME
79
THX_51_PLIIZ_GAMES
7A
THX_51_NEO6_GAMES
7B
THX_51_NEURAL_GAMES
7C
THX_20_NEOX_GAMES
7D
THX_51_NEOX_GAMES
7E
THX_20_DOLBY_SURR_GAME
7F
THX_51_DOLBY_SURR_GAME
80
THX_GAME_LMD_END
90 THX_CINEMA_LMD_BEGIN
91 THX_20_PLII_MOVIE
92 THX_20_PLIIX_MOVIE
93 THX_20_PLIIZ_CINEMA
94 THX_20_NEO6_MOVIE
95 THX_20_NEURAL_CINEMA
96 THX_51_OFF_CINEMA
97 THX_51_MTR_CINEMA
98 THX_51_DSC_CINEMA
99 THX_51_NEO6_CINEMA
9A THX_51_PLIIX_MOVIE
9B THX_51_PLIIZ_CINEMA
9C THX_51_NEURAL_CINEMA
9D THX_51_EX
9E THX_20_NEOX_CINEMA
9F THX_51_NEOX_CINEMA
A0 THX_20_DOLBY_SURR_CINEMA
A1 THX_51_DOLBY_SURR_CINEMA
A2 THX_CINEMA_LMD_END
B0 THX_U2GAME_LMD_BEGIN
B1 THX_20_PLII_SLCT2_GAME
B2 THX_20_PLIIZ_SLCT2_GAME
B3 THX_51_SLCT2_GAM
B4 THX_51_PLIIZ_SLCT2_GAME
B5 THX_U2GAME_LMD_END
B6 THX_U2MUSIC_LMD_BEGIN
B7 THX_51_SLCT2_MUS
B8 THX_51_PLIIZ_SLCT2_MUSIC
B9 THX_U2MUSIC_LMD_END
BA
THX_U2CINEMA_LMD_BEGIN
BB
THX_51_SLCT2_CIN
BC
THX_51_PLIIZ_SLCT2_CINEMA
BD
THX_U2CINEMA_LMD_END
D0 AUDYSSEY_LMD_BEGIN
D1 AUDYSSEY_20_PLII_MUSIC
D2 AUDYSSEY_20_PLIIX_MUSIC
D3 AUDYSSEY_20_NEO6_MUSIC
D4 AUDYSSEY_20_NEURAL_CINEMA
D5 AUDYSSEY_20_NEURAL_MUSIC
D6 AUDYSSEY_20_PLII_MOVIE
D7 AUDYSSEY_20_PLIIX_MOVIE
D8 AUDYSSEY_20_NEO6_MOVIE
D9 AUDYSSEY_20_PLII_GAME
DA AUDYSSEY_20_PLIIX_GAME
DB AUDYSSEY_51_OFF
DC AUDYSSEY_51_PLIIX_MUSIC
DD AUDYSSEY_51_PLIIX_MOVIE
DE AUDYSSEY_51_NEO6
DF AUDYSSEY_51_NEURAL_CINEMA
E0 // AUDYSSEY_51_NEURAL_MUSIC
E1 AUDYSSEY_51_EX
E2 AUDYSSEY_LMD_END
F0 SPECIAL_LMD_BEGIN
F1 TESTTONE
F2 TESTTHR
F3 TESTAUTO
F4 ASC
F5 FLASH
F6 DEBUGMODE
F7 FLASH2
F8 FLASH3
F9 FLASH4
FA FLASH_CHECK
FB SPECIAL_LMD_END

WiFi 5GHz Setting
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Wireless LAN 5GHz Setting
IMPORTANT!!
Back Ground:
It is totally different from Radio Law at the each country on 5GHz band.
It means it is totally different from enabled Channel of 5GHz band at the each country.
We define the “Country Code” for 5GHz band.
You must set up the appropriate country code to the product.
Example;
Case1:
When you use the “P” destination products and bring move to Russia or Israel,
If you did not setup change country code and use in Russia and Israel,
You will be on the illegal Radio Law in Russia and Israel.
Case2;
When you use “C” or “D” destination product bring move to Japan or Taiwan,
If you did not setup change country code and use in Japan and Taiwan,
You will be on the illegal Radio Law in Japan and Taiwan.
Service Parts information:
The default country code is set on “Processing Circuit Board(PRC board)”.
You must make sure and set up the “Country Code“ when you replace the processing
circuit pc board.
Otherwise You and your customer should be on the illegal Radio Law and
IT HAS POSSIBILITY TO HAVE A RISK OF
PUNISHMENT FROM EACH COUNTRY GOVERNMENT.
If you did not make sure country code and no setup code and face any trouble,
We does not have any responsibility.
For setting up the Country Code,
Please ask the procedure of changing country code
to your distributer or our sales.
It is no described the procedure of changing Country Code on this Service Manual
If you have any trouble of unclear procedure for update country code,
Please contact our sales department.
PRC Board Default Value of Country Code
The PRC board is already set default Country Code by the representative destination.
To confirm the default country code, Please refer to the "How to read PRC Board part
number and Default value of Country Code"section.

WiFi 5GHz Setting
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Wireless LAN 5GHz Setting
IMPOTANT!!
Make sure and Setup Country Code
You have to make sure country code for using or replacing “Processing Circuit PC
Board”.
It means that you have to make sure country code between using Processing Circuit
PC board( PRC Board) and your customer’s country code.
When it is not match PRC board default country code and customer’s country, you
have to setup Country Code.
Case3;
When you repair the “P” destination products and replace “P” destination PRC Board
and the customer live in UK, It is no necessary to setup Country Code
Because “P” destination PRC board already setup “EU” country code.
Match Country code
NO NECESSARY TO SETUP COUNTRY CODE
Case4;
When you repair the “P” destination products and replace “P” destination PRC board
and the customer live in Russia, It is necessary to setup Country Code
Because “P” destination PRC Board already setup “EU” country code.
However, the customer’s country code is “RU”. It means no match PRC Board code
and Customer’s code.
No Match Country code
NECESSARY TO SETUP COUNTRY CODE
Case5;
When you repair the “C” destination products and replace “C” destination PRC board
and the customer live in US, it is no necessary to setup Country Code
Because “C” destination PRC board already setup “US” country code.
Match Country code
NO NECESSARY TO SETUP COUNTRY CODE
Case6;
When you repair the “C” destination product and replace “C” destination PRC board
and the customer live in Taiwan, It is necessary to setup Country Code.
Because “C” destination PRC Board already setup “US” country code as default.
However, the customer’s country code is “TW”. It means no match PRC Board code
and the customer’s country code
No Match Country code
NECESSARY TO SETUP COUNTRY CODE
Customer: UK: EU PRC Board: EU
Customer: Russia: RU PRC Board: EU
Customer: US: US PRC Board: US
Customer: Taiwan: TW PRC Board: US

WiFi 5GHz Setting
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Wireless LAN 5GHz Country Code 1/2
Region Country Code
America
USA US
Canada US
Mexico US
Brazil US
Chile CL
Guatemala US
Puerto Rico US
Trinidad TT
Dominican Rep US
Argentina AR
Ecuador US
Paraguay PY
Colombia US
Guam US
Panama US
Costa Rica US
Uruguay UY
Peru PE
Region Country Code
Asia / Oceania
Japan JP
China CN
Hong Kong EU
Korea KR
Taiwan TW
Singapore SG
Malaysia MY
Philippines EU
Vietnam EU
Indonesia ID
Sri Lanka EU
Australia AU
New
Zealand AU
Thailand EU
India IN
Pakistan PK
Region Country Code
Middle East
UAE EU
Bahrain BH
Kuwait KW
Oman EU
Qatar QA
Lebanon EU
Jordan JO
Saudi Arabia EU

WiFi 5GHz Setting
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
Wireless LAN 5GHz Country Code 2/2
Region Country Code
Europe / Africa
Germany EU
UK EU
France EU
Netherlands EU
Italy EU
Switzerland EU
Denmark EU
Sweden EU
Austria EU
Belgium EU
Spain EU
Norway EU
Finland EU
Czech EU
Israel IL
Ukraine EU
Hungary EU
Slovakia EU
Luxembourg EU
Turkey EU
Portugal EU
Malta EU
Latvia EU
Poland EU
Region Country Code
Europe / Africa
Cyprus EU
Estonia EU
Slovenia EU
Bulgaria EU
Greece EU
Romania EU
Lithuania EU
Serbia EU
Croatia EU
Ireland EU
Macedonia EU
Moldova EU
Russia RU
Andorra EU
Armenia EU
Azerbaijan EU
Belarus EU
Bosnia and
Herzegovina EU
Northern
Cyprus(Turkey) EU
Georgia EU
Iceland EU
Kazakhstan EU
Region Country Code
Europe / Africa
Liechtenstein EU
Monaco EU
Montenegro EU
San Marino EU
Vatican City EU
Kosovo EU
Kaliningrad(Russia) RU
Gibraltar(UK) EU
Canary
Islands(Spain) EU
Ceuta EU
Melilla EU
Morocco MA
Algeria EU
Tunisia TN
Egypt EG
Mauritius US
South Africa EU

WiFi 5GHz Setting
543
2
1 6
D
C
A
B
D
C
A
B
543
2
1 6 COMMON
How to read PRC Board part number and Default value of Country Code
1B5142049-2A686MDC
Board No.
585 : TX-NR585
686 : TX-NR686
787 : TX-NR787
620 : TX-RZ620
720 : TX-RZ720
820 : TX-RZ820
PRC Board Default setting Country Code
Dst Code Main Country
C US North America
D US United State
S US Brazil
P EU Europe
B EU United Kingdom
Q EU Hong Kong
T EU Thai
L RU Russia
A AU Australia / New Zealand
R CN China
F TW Taiwan
K KR Korea
J JP Japan
Model Number Last 3 Digit Destination
Suffix No.
1B5142049 : TX-NR585, TX-NR686
1B5142605 : TX-NR787, TX-RZ620
TX-RZ720, TX-RZ820

Firmware
5 4 3
2
1 6
D
C
A
B
D
C
A
B
5 4 3
2
1 6
TX-RZ630/RZ730/RZ830
How to check Firmware Version & Preparation of Update
Step1 : [DIMMER] + [ON/STANDBY] x 2
Main Firmware Version will appear on the main unit’s display.
Step2 : [TONE +1] ( Rotate “TONE” knob right 1 click)
NET Firmware Version will appear on the main unit’s display.
Step3 : [TONE +2] ( Rotate “TONE” knob right 2 click)
DSP Firmware Version will appear on the main unit’s display.
Step4 : [TONE +3 ] ( Rotate “TONE” knob right 3 click)
Video Firmware Version will appear on the main unit’s display.
Step5 : [TONE +4] ( Rotate “TONE” knob right 4 click)
OSD Firmware Version will appear on the main unit’s display.
Step6 : [TONE +5 over] ( Rotate “TONE” knob right 5 click over)
Return to Display Main Firmware Version ( Return Step1)
When It is rotated left ( - ) TONE knob, It is appeared before step.
[Preparation of Update]
1. Connect the USB storage device to your PC. If there is any data in the USB storage
device, remove it.
2. Download the firmware file (package file) from the Onkyo FTP-server. However European
service partners should download the firmware file (package file) from the ExtraNet.
Onkyo FTP-server: ftp://manex.onkyo.co.jp/
ID and Password are those we informed when changed.
Filename is as follows: ONKAVR0029******************.zip
Unzip the downloaded file. A following file is created.
ONKAVR0029**************.of0
ONKAVR0029**************.of1
ONKAVR0029**************.of2
ONKAVR0029**************.of3
ONKAVR0029**************.of4
3. Copy it to the USB storage device. Be careful not to copy the zip file.
4. Remove the USB storage device from your PC.

Firmware
5 4 3
2
1 6
D
C
A
B
D
C
A
B
5 4 3
2
1 6
TX-RZ630/RZ730/RZ830
How to Update (service mode) 1/2
Overwriting is also possible.
1. Connect the USB strage to the USB port on the unit.
2. Turn on the unit. It takes some time to start after you switch on the unit.
Press: [DIMMER] + [ON/STANDBY] x 2
3. Press [RETURN] button, Then it is displayed as below
If you need each module of the firmware update, you can select the module by pressing
PRESET < and > button.
If you need change source NET or USB, you can select the source by pressing
TUNING UP and Down key
It should be updated firmware by selecting USB -> ALL normally.
Please Do NOT choose T-SRV (it is test server)
USB -> ALL: ALL firmware update ( default )
USB -> DSP1: DSP firmware update
USB -> OSD: OSD firmware update
USB -> VMPU: VMPU firmware update
USB -> NET: NET firmware update
USB -> MMPU: Main MPU firmware update
USB -> WORK: Compare between AVR and USB, Only update new version firmware
NET -> ALL: ALL firmware update ( default )
NET -> DSP1: DSP firmware update
NET -> OSD: OSD firmware update
NET -> VMPU: VMPU firmware update
NET -> NET: NET firmware update
NET -> MMPU: Main MPU firmware update
NET -> WORK: Compare between AVR and MMC,
Only update new version firmware by network
The default setting is “ ALL”
CAUTION: When you will update each module firmware,
you have to keep combination of firmware.

Firmware
5 4 3
2
1 6
D
C
A
B
D
C
A
B
5 4 3
2
1 6
TX-RZ630/RZ730/RZ830
How to Update (service mode) 2/2
4. Press [ENTER] button. Start update firmware.
5. Wait until update is completed. When the update ends, “Completed!” is displayed. When
“ Completed!” message appeared, you can power off by pressing “ ON/STANDBY” button.
(If you leave it, it automatically turns standby mode. )
6. Press [ON/STANDBY] button, and the unit turns on.
7. Check the new FW version number.
<Note>
If the procedure might not be successful, please select “USB -> ALL”.
Other manuals for TX-RZ830
1
Table of contents
Other Onkyo Stereo Receiver manuals

Onkyo
Onkyo TX-8260 User manual

Onkyo
Onkyo TX-SR373 User manual

Onkyo
Onkyo TX-8255 User manual

Onkyo
Onkyo TX-8211 User manual

Onkyo
Onkyo TX-8211 User manual

Onkyo
Onkyo TX-SR393DAB User manual

Onkyo
Onkyo TX-8211 User manual

Onkyo
Onkyo TX-2100 User manual

Onkyo
Onkyo K-185X User manual

Onkyo
Onkyo TX-1500 User manual

Onkyo
Onkyo TX-8020 User manual

Onkyo
Onkyo TX-8255 User manual

Onkyo
Onkyo TX-NR696 Manual

Onkyo
Onkyo TX-NR6100 User manual

Onkyo
Onkyo TX-8255 User manual

Onkyo
Onkyo TX-8500 User manual

Onkyo
Onkyo Integra TX-DS898 User manual

Onkyo
Onkyo TX-NR1000E User manual

Onkyo
Onkyo TX-NR929 Setup guide

Onkyo
Onkyo TX-SR875 User manual