2
SPECIFICATION PARAMETER (GB)
Model number CZL544 / 4548176
Supply Voltage 220-240V~, 50/60 Hz
Protection class Class I
Type of wiring Cable 1.0 m H07RN-F 3 x 1.5 mm2
Power consumption 25 W (19 W / 12,5 W / 7,5 W)
Color temperature 3CCT: 3000 K / 4000 K / 5000 K
Luminous ux 3200 lm
Color rendering index CRI > 80
Degree of protection IP66
Impact strength IK10
Housing color Black (RAL9017)
Dimensions Ø203 x 975 mm
Weight 5.3 kg
Working Temperature -30°C... +45°C
Storing Temperature -40°C...+70°C
Max. number of luminaires per
miniature circuit breaker
B10: 55
C16: 88
Lumen output 3000 K 4000 K 5000 K
CZL544
25W 3000lm 3200lm 3150lm
19W 2250lm 2450lm 2400lm
12,5W 1500lm 1600lm 1600lm
7,5W 950lm 1000lm 1000lm
Important safety instruction
To ensure correct function and safety, please read and follow all instruction carefully before using the product,
Basic safety precautions should always be followed when installing, including the following:
1. Turn o power supply before installation or before doing any maintenance, cleaning, changing the globe or
adjustment to the tting.
2. Do not install any luminaire near the heat source.
3. IP grade please refer to product label, only IP54 can be used in wet or damp locations.
4. Do not exceed the nominal supply voltage or amperage ratings.
5. All wiring and installation of the light tting must adhere to local and national wiring rules.
6. Take care not to pull any electrical wires during unpacking as this may damage the connection.
7. Lay out all the components on a smooth surface and make sure there are no components missing before
assembling.
8. To avoid injury or damage to the tting, please ensure that power leads and screws are secure before connecting
the power.
9. If the external exible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the
manufacturer or his service agent or a similar qualied person in order to avoid a hazard.
10. The light source or driver contained in this luminaire shall only be replaced by the manufacturer or other
qualied person.
11. Please keep instruction for future reference.
Warning:
1. Switch o before installation.
2. Switch on only after complete installation and
examination of the circuit.
3. Professional electrician for installation and
maintenance only.
Turn O Power
Supply