Operative Experience RealMom User manual

OEI Part Number 10002_A
RealMomTM

RealMom
copyright © 2018 Operative E perience 10002_A
i
All rights reserved
Copyright Notice
Copyright ©2018 Operative E perience, Inc. All rights reserved.
This documentation is protected by the copyright laws as an unpublished work.
Confidentiality and Proprietary Rights
This documentation is the confidential property of Operative E perience, Inc. It is furnished under an
agreement with Operative E perience, Inc. and may only be used in accordance with the terms of that
agreement. The use of this documentation is restricted to customers of Operative E perience, Inc. and
their employees who have a need to know the contents of this documentation. The user of this
documentation agrees to protect the Operative E perience, Inc. proprietary rights as e pressed herein.
The user further agrees not to permit access to this documentation by any person for any purpose other
than as an aid in the use of the associated products. In no case will this documentation be e amined for
the purpose of copying any portion of the product described herein or to design another product to
accomplish similar results. This documentation or portions of it may not be copied, modified or
distributed without written permission from Operative E perience, Inc. The information in this
documentation is subject to change without notice.
No part of this documentation may be reproduced in any form or incorporated into any information
retrieval system, electronic or mechanical, without the written permission of the copyright owner.
Inquiries regarding permission for use of material contained in this documentation should be
addressed to:
Operative E perience, Inc.
500 Principio Parkway West, Suite 900
North East, MD 21901
Phone: 410-287-5748
E-mail: info@operativee perience.com
Disclaimer
This documentation is provided “as is” without any e press or implied warranty of any kind including
warranties of merchantability, non-infringement of intellectual property, or fitness for any particular
purpose. In no event shall Operative E perience, Inc. or its representatives be liable for any damages
whatsoever (including, without limitation, damages for loss of profits, business interruption, or loss of
information) arising out of the use of or inability to use this documentation, even if Operative
E perience, Inc. has been advised of the possibility of such damages. Because some jurisdictions prohibit
the e clusion or limitation of liability for consequential or incidental damages, the above limitation may
not apply to you. Operative E perience, Inc. further does not warrant the accuracy or completeness of
the information, te t, graphics, or other items contained within these materials.
Operative E perience is a registered trademark of Operative E perience, Inc. Germaben II is a registered
trademark of International Specialty Products. Google Play is a trademark of Google LLC. iTunes is a
registered trademark of Apple Inc. All other company names, logos, and trademarks mentioned herein
are the property of their respective owners.

RealMom
copyright © 2018 Operative E perience 10002_A
ii
All rights reserved
Table of Contents
Figures .......................................................................................................................................................... iv
The RealMom Simulator System ................................................................................................................... 1
Product Components ................................................................................................................................ 1
E ternal Access ......................................................................................................................................... 1
Caring for Your Simulator.............................................................................................................................. 2
Lubrication ................................................................................................................................................ 2
Use and Treatment ................................................................................................................................... 2
Cleaning..................................................................................................................................................... 2
Storage ...................................................................................................................................................... 2
Troubleshooting ........................................................................................................................................ 2
RealMom ....................................................................................................................................................... 3
Understanding the Tablets ........................................................................................................................... 4
Configuring the Tablets ............................................................................................................................. 4
Downloading from the Apple App Store ............................................................................................... 4
Downloading from the Google Play Store ............................................................................................ 4
Configuring the Wireless Connection ....................................................................................................... 5
Establishing the Wireless Connection ....................................................................................................... 5
Running the Simulation ................................................................................................................................. 6
Connecting the Power............................................................................................................................... 6
Powering On.............................................................................................................................................. 6
Preparing the Simulators .......................................................................................................................... 7
Using the Tablet ........................................................................................................................................ 9
Controlling the Simulation with the Instructor Interface ..................................................................... 9
Viewing RealMom’s Condition Using the Trainee Interface Tablet ...................................................... 9
Understanding the OEI Sim Application ...................................................................................................... 10
Using the Operational Panel ................................................................................................................... 11
Setting the Physiological Controls .......................................................................................................... 12
Heart Rate ........................................................................................................................................... 12
HR Condition ....................................................................................................................................... 13
Bleeding (PPH)..................................................................................................................................... 14

RealMom
copyright © 2018 Operative E perience 10002_A
iii
All rights reserved
Blood Pressure .................................................................................................................................... 15
Temperature ....................................................................................................................................... 16
SpO2 .................................................................................................................................................... 17
Respiratory Rate.................................................................................................................................. 17
Fetal Heart Rate .................................................................................................................................. 18
Station ................................................................................................................................................. 18
Effacement .......................................................................................................................................... 19
Dilation ................................................................................................................................................ 19
Shoulder Dystocia ............................................................................................................................... 20
Recording the Simulation ........................................................................................................................ 20
Modifying Settings .................................................................................................................................. 21
The Trainee Interface .......................................................................................................................... 22
Light Mode (Dark Mode Set to Off) .................................................................................................... 23
Viewing the Simulation Logs ................................................................................................................... 24
E amining Diagnostics ............................................................................................................................ 25
Viewing the About Page .......................................................................................................................... 27
Operating Your Simulator ........................................................................................................................... 28
Inserting the Birth Canal ......................................................................................................................... 28
Sealing the Vaginal Opening ................................................................................................................... 31
Connecting the Fluid Supplies ................................................................................................................. 32
Troubleshooting During Operation ......................................................................................................... 34
Shutting Down the Simulator .................................................................................................................. 35
Performing Deliveries ............................................................................................................................. 36
Modifying the Delivery ........................................................................................................................ 36
Controlling the Postpartum Hemorrhage Control .............................................................................. 37
Maintaining Your Simulator ........................................................................................................................ 38
Flushing/Cleaning the Bleeding System .................................................................................................. 38
Upgrading the Simulator’s Firmware ...................................................................................................... 38
Requirements ...................................................................................................................................... 38
Procedure ............................................................................................................................................ 38
Storing the Simulators ................................................................................................................................ 44

RealMom
copyright © 2018 Operative E perience 10002_A
iv
All rights reserved
Figures
FIGURE 1: REALMOM AND BABY ........................................................................................................................................... 3
FIGURE 2: CONFIGURING THE WI-FI CONNECTION .................................................................................................................... 5
FIGURE 3: THE SHORTCUT ICON ............................................................................................................................................ 5
FIGURE 4: LOADING THE SIMULATION APPLICATION .................................................................................................................. 5
FIGURE 5: THE POWER CORD CONNECTED TO THE SIMULATOR ................................................................................................... 6
FIGURE 6: THE POWER BUTTON IN THE ON MODE ................................................................................................................... 6
FIGURE 7: LUBRICATING THE BABY ......................................................................................................................................... 7
FIGURE 8: INSERTING THE BABY............................................................................................................................................. 7
FIGURE 9: BABY'S ANTERIOR (HEAD) OPENING ........................................................................................................................ 8
FIGURE 10: BABY'S POSTERIOR OPENING ................................................................................................................................ 8
FIGURE 11: PUSHER INSERTED .............................................................................................................................................. 8
FIGURE 12: POSITIONING THE PLACENTA ................................................................................................................................ 8
FIGURE 13: THE ABDOMINAL SKIN IN POSITION ....................................................................................................................... 8
FIGURE 14: THE INSTRUCTOR TABLET’S MAIN SCREEN ............................................................................................................ 10
FIGURE 15: THE MENU ..................................................................................................................................................... 11
FIGURE 16: THE PLAY AND STOP BUTTONS............................................................................................................................ 11
FIGURE 17: PHYSIOLOGICAL CONTROLS ................................................................................................................................ 12
FIGURE 18: SETTING THE HEART RATE .................................................................................................................................. 12
FIGURE 19: SETTING BLEEDING ........................................................................................................................................... 14
FIGURE 20: CONTROLLING THE BLOOD PRESSURE ................................................................................................................... 15
FIGURE 21: SETTING THE TEMPERATURE ............................................................................................................................... 16
FIGURE 22: SETTING THE SPO2 ........................................................................................................................................... 17
FIGURE 23: SETTING THE RESPIRATORY RATE ......................................................................................................................... 17
FIGURE 24: SETTING THE FETAL HEART RATE ......................................................................................................................... 18
FIGURE 25: CONTROLLING THE STATION ............................................................................................................................... 18
FIGURE 26: CONTROLLING EFFACEMENT ............................................................................................................................... 19
FIGURE 27: SETTING DILATION............................................................................................................................................ 19
FIGURE 28: SHOULDER DYSTOCIA SET TO ON ........................................................................................................................ 20
FIGURE 29: RECORDING THE SIMULATION ............................................................................................................................. 20
FIGURE 30: THE SETTINGS PAGE ......................................................................................................................................... 21
FIGURE 31: SELECTING THE CONTROL INTERFACE TYPE ............................................................................................................ 21
FIGURE 32: SELECTING THE LANGUAGE ................................................................................................................................. 21
FIGURE 33: THE TRAINEE INTERFACE .................................................................................................................................... 22
FIGURE 34: INSTRUCTOR INTERFACE IN LIGHT MODE .............................................................................................................. 23
FIGURE 35: TRAINEE INTERFACE IN LIGHT MODE .................................................................................................................... 23
FIGURE 36: THE SIMULATION LOGS PAGE ............................................................................................................................. 24
FIGURE 37: THE DIAGNOSTICS PAGE .................................................................................................................................... 25
FIGURE 38: SYSTEM DIAGNOSTICS SHOWING SYSTEM FAILURES ................................................................................................ 26
FIGURE 39: REBOOT SIMULATOR VERIFICATION MESSAGE ....................................................................................................... 26
FIGURE 40: SHUTDOWN SIMULATOR VERIFICATION MESSAGE .................................................................................................. 26
FIGURE 41: THE ABOUT PAGE ............................................................................................................................................ 27
FIGURE 42: PREPARING THE BIRTH CANAL ............................................................................................................................ 28
FIGURE 43: INSERTING THE BIRTH CANAL .............................................................................................................................. 28

RealMom
copyright © 2018 Operative E perience 10002_A
v
All rights reserved
FIGURE 44: PULLING THE UTERUS INTO PLACE ....................................................................................................................... 29
FIGURE 45: POSITIONING THE BIRTH CANAL .......................................................................................................................... 29
FIGURE 46: COMPLETING THE BIRTH CANAL PLACEMENT ......................................................................................................... 30
FIGURE 47: MIXING THE ADHESIVE ...................................................................................................................................... 31
FIGURE 48: APPLYING THE ADHESIVE ................................................................................................................................... 31
FIGURE 49: SECURING THE SKIN .......................................................................................................................................... 31
FIGURE 50: CONNECT THE LINES IN THE ABDOMEN ................................................................................................................. 32
FIGURE 51: FLUID LINE LOCATION ....................................................................................................................................... 32
FIGURE 52: CONNECTING THE FLUID LINES ON THE LEFT SHOULDER ........................................................................................... 33
FIGURE 53: THE LEFT SHOULDER FLUID LINES CONNECTED ....................................................................................................... 33
FIGURE 54: THE SIMULATOR HIGH TEMPERATURE WARNING ................................................................................................... 34
FIGURE 55: CONNECTION ERROR NOTIFICATION..................................................................................................................... 34
FIGURE 56: DELIVERY ASSISTED BY SUCTION .......................................................................................................................... 36
FIGURE 57: DELIVERY ASSISTED BY FORCEPS .......................................................................................................................... 36
FIGURE 58: DOWNLOADING THE UPDATE FILE ....................................................................................................................... 39
FIGURE 59: OPEN THE MENU ON THE OEI SIM APP .............................................................................................................. 39
FIGURE 60: CLICK SETTINGS ............................................................................................................................................... 40
FIGURE 61: SEARCHING FOR A FILE (MAC OS) ....................................................................................................................... 40
FIGURE 62: SEARCHING FOR A FILE (WINDOWS) .................................................................................................................... 40
FIGURE 63: CLICK APPLY UPDATE ........................................................................................................................................ 41
FIGURE 64: CLICK OK ON THE CONNECTION ERROR MESSAGE .................................................................................................. 41
FIGURE 65: THE EMERGENCY AIRWAY NECK BAND ................................................................................................................. 41
FIGURE 66: OPEN THE MENU ON THE OEI SIM APP .............................................................................................................. 42
FIGURE 67: SELECT ABOUT ................................................................................................................................................. 42
FIGURE 68: VERIFY VERSIONS ON THE ABOUT PAGE ................................................................................................................ 43
FIGURE 69: PLACING THE SIMULATOR IN THE STORAGE CASE .................................................................................................... 44
FIGURE 70: SECURING THE SIMULATOR IN THE STORAGE CASE .................................................................................................. 44

RealMom
copyright © 2018 Operative E perience 10002_A
1
All rights reserved
The RealMom Simulator System
The RealMom simulator system includes a full-body birthing female manikin and a full-term baby
manikin for realistic natural deliveries. RealMom features relevant bony landmarks, accurate anatomy,
lifelike skin and naturally elastic soft tissue, an active birth canal with real-time dilation and fetal station
progression controlled by touch screen software. RealMom sets up easily and requires no complicated
programming or maintenance. Though RealMom has the durability required to perform consecutive
birthing simulations throughout the day, she should be treated as you would a human patient.
Two iPads (or, alternatively, two Android tablets) are provided for the instructor and trainee, but the
simulator may also be run on any device with a browser and wireless capabilities.
Product Components
Each wireless, full-body female simulator comes with all the components needed to perform multiple
delivery scenarios.
RealMom Simulator
1
Baby with Placenta Cord
1
Case with Casters 1
iPad (or Tablet)
2
iPad Case (Tablet Case)
2
iPad Set-Up Instructions
1
Fake Blood (Bag)
1
Fake Urine (Bag)
1
Amniotic Fluid (Bag)
1
Lubricant (Bag)
1
Glycerin (Bottle)
2
Hospital Gown
1
Pair of Socks
1
User Manual
1
External Access
RealMom is designed for realism, with only a few e ternal access points:
A skin slit with flap in the abdomen for insertion of the baby manikin
Fluid infusion ports located on the left shoulder for blood, amniotic fluid, lubricant and urine
A power receptacle located on the right shoulder

RealMom
copyright © 2018 Operative E perience 10002_A
2
All rights reserved
Caring for Your Simulator
Treat the simulators as you would human patients.
Technical Support
Simulators must be serviced by qualified OEI technicians only.
To schedule service, contact:
Operative E perience Inc.
500 Principio Parkway West
Suite 900
North East, MD 21901
Phone: 410-287-5748
Email: support@operativee perience.com
ubrication
Glycerine (or cotton seed oil) should be used liberally to lubricate both the baby and placenta and the
inside and outside the vaginal area.
Use and Treatment
The simulators are durable, but not indestructible. RealMom weighs 130 pounds, so be sure to take the
necessary safety steps to ensure she is lifted and moved properly. RealMom is water-resistant, but not
waterproof, so do not immerse the simulator in water.
Cleaning
Simulators can be wiped clean with a simple solution of mild soap and water.
Storage
Simulators should be dry, fluid free, and without clothes during long-term storage. See Storing the
Simulators below. The blood flow system does not need to be flushed for overnight storage, but must be
for long-term (one week or more) storage. See Flushing/Cleaning the Bleeding System below.
Troubleshooting
User-troubleshooting is restricted to the functions described in this manual. Simulator electronics are
inaccessible and should only be serviced by qualified OEI technicians.

RealMom
copyright © 2018 Operative E perience 10002_A
3
All rights reserved
RealMom
Every simulation with RealMom requires preparation and use of the female manikin, the baby manikin,
and the OEI Sim Application for instructor control and the patient monitor.
Figure 1: RealMom and Baby
The full-body female manikin measures 65”H 23.6”W 11”D (165cm 60cm 28cm), weighs 130
pounds (59kg), and is available in diverse skin tones. With natural feeling skin and soft tissue, the female
manikin has articulating legs, an authentic pelvic structure, a massageable fundus, and a naturally
dilating cervi for realistic deliveries.
The full-term baby manikin measures 10”H 5”W 7”D (25.4cm 12.7cm 17.78cm), weighs 6.3
pounds (2.85kg), and has a realistic placenta and umbilical cord. Once placed inside the female manikin,
the baby may be moved through the fetal stations using software commands.
Two iPads (or Android tablets) are included with the simulator with the OEI software used operate the
Instructor Control Interface (for instructors) and the Virtual Monitor (for trainees). The OEI Sim
Application can be projected onto a screen for large-scale viewing in a classroom or laboratory.
The OEI Sim application can be downloaded from Google Play™ or the App Store by searching for an App
using OEI Sim or Operative E perience as your search criteria (see Configuring the Tablets below).

RealMom
copyright © 2018 Operative E perience 10002_A
4
All rights reserved
Understanding the Tablets
The Instructor Interface tablet is used to start and stop the simulation, control the features and provide
you with a log with a record of the simulation. In Trainee mode, the software on the tablet provides
learners the ability to view information on RealMom’s vital signs along with an ECG and the fetal heart
beat. Alternative devices can be used when the Operative E perience software has been installed.
Configuring the Tablets
Prior to their first use, the tablet should be configured with the OEI Application, which can be
downloaded from the App Store (for iOS devices such as the iPad) or the Google Play Store (for Android
devices). For additional information on how to install the software, visit the Operative E perience
Support page (https://operativee perience.com/support/), which has links to pages with detailed
information about downloading and installing applications.
Downloading from the Apple App Store
For all iOS devices, the App Store is a default application on your screen. You’ll need an Apple ID to
download and install the OEI application using either the App Store (or iTunes®).
1. Click the App Store icon to go to the store’s page.
2. Use the Search field (i.e., the field with the magnifying glass) and enter OEI Sim or Operative
E perience as your search criteria.
3. Select the OEI APP and click Get.
4. Click Install.
You can also access the application by going directly to http://appstore.com/oeisim.
Downloading from the Google Play Store
For most Android devices, the Play Store is a default application on your screen. To download
1. Click the Play Store icon (or go to https://play.google.com/store) to go to the store’s page and
select Apps.
2. Use the Search field (i.e., the field with the magnifying glass) and enter OEI Sim or Operative
E perience as your search criteria.
3. Click the OEI APP icon.
4. Click Install.
You can also access the application by going directly to
https://play.google.com/store/apps/details?id=com.operativee perience.oeiapp.

copyright © 2018 Operative E perience
All rights reserved
Configuring the Wireless Connection
When you first configure the wireless connection (or, if the tablet’s Wi
simulator network) a page appears with a field for the
Figure
1. Enter the IP address of
10.42.0.1
2. Click Go (or press nter).
The OEI Sim application appears.
Establishing the Wireless Connection
Power on the tablet.
Make sure RealMom has been prepared for the simulation, having been turned on and the baby
positioned.
1. On the Instructor tablet’s Wi
-
network, indicated by OVD and the simulator’s serial number (OVD
XXX). For e ample, a simulator with the serial number of 002 has a
wireless network of OVD-
002.
2. Enter the password of
oeiadmin
3.
Once the wireless connection has been established, click the
shortcut icon for the simulator.
The OEI Sim application loads.
Figure
The OEI Sim application appears.
10002_A
Configuring the Wireless Connection
When you first configure the wireless connection (or, if the tablet’s Wi
-
Fi doesn’t recognize the
simulator network) a page appears with a field for the
Simulator IP.
Figure
2: Configuring the Wi-Fi Connection
10.42.0.1
for the simulator. The IP address is always
10.42.0.1.
Establishing the Wireless Connection
Make sure RealMom has been prepared for the simulation, having been turned on and the baby
-
Fi settings, select the simulator’s
network, indicated by OVD and the simulator’s serial number (OVD
-
XXX). For e ample, a simulator with the serial number of 002 has a
002.
oeiadmin
.
Once the wireless connection has been established, click the
shortcut icon for the simulator.
Figure
4: oading the Simulation Application
The OEI Sim application appears.
Figure 3
: The Shortcut Icon
RealMom
5
Fi doesn’t recognize the
10.42.0.1.
Make sure RealMom has been prepared for the simulation, having been turned on and the baby
: The Shortcut Icon

copyright © 2018 Operative E perience
All rights reserved
Running the
Simulation
Begin the simulation by powering up the simulator and opening the software on the tablet(s).
DO NOT INSERT THE BABY UNTIL THE SIMULATOR HAS BEEN TURNED ON
CALIBRATION.
Connecting the Power
Attach the power cord to
the connection on the
Figure 5
: The Power Cord Connected to the Simulator
Plug the power cord into the
AC receptacle.
Powering On
Be sure the baby has NOT been loaded into the simulator.
1. Power on the simulator by
holding down the button on the
seconds o
r until the blue light comes on
Figure
The simulator powers up.
2. Turn on the
tablets and connect to the WiFi
10002_A
Simulation
Begin the simulation by powering up the simulator and opening the software on the tablet(s).
DO NOT INSERT THE BABY UNTIL THE SIMULATOR HAS BEEN TURNED ON
and HAS
COMPLETED
Connecting the Power
the connection on the
right shoulder.
: The Power Cord Connected to the Simulator
AC receptacle.
Be sure the baby has NOT been loaded into the simulator.
holding down the button on the
right shoulder
for appro imately two
r until the blue light comes on
.
Figure
6: The Power Button in the On Mode
tablets and connect to the WiFi
.
RealMom
6
Begin the simulation by powering up the simulator and opening the software on the tablet(s).
COMPLETED
for appro imately two

RealMom
copyright © 2018 Operative E perience 10002_A
7
All rights reserved
Preparing the Simulators
The baby should be inserted into RealMom only AFTER the SIMULATOR is TURNED ON and the boot
sequence, which moves and calibrates the actuator, has completed.
1. Once the simulator has been turned on, generously lubricate the baby and placenta with
Glycerine.
Figure 7: ubricating the Baby
2. Generously lubricate the abdominal cavity.
3. Lift the abdominal and uterine opening and insert the baby into the cavity.
Figure 8: Inserting the Baby
4. Position the baby and placenta according to the procedure being practiced.

copyright © 2018 Operative E perience
All rights reserved
5. Ensure the baby is
positioned a
positioning with
the pusher inserted into
Figure 9: Baby's Anterior (Head)
Opening
6.
Insert the placenta on top of the baby to lower left of the pelvis. Ens
the baby’s head.
7. Generously
lubricate the vaginal area inside and out with Glycerine (or cotton seed oil).
8.
Pull the abdominal skin flap back into place
Figure
The simulation can now be initiated by pressing the Play button on the Instructor Interface tablet.
10002_A
positioned a
gainst the “pusher” cover. The baby
has an opening that enables
the pusher inserted into
either the head or the posterior.
Figure 10: Baby's Posterior
Opening
Figure 11
: Pusher Inserted
Insert the placenta on top of the baby to lower left of the pelvis. Ens
ure the cord is not blocking
Figure 12: Positioning the Placenta
lubricate the vaginal area inside and out with Glycerine (or cotton seed oil).
Pull the abdominal skin flap back into place
and close the abdomen using the zipper
Figure
13: The Abdominal Skin in Position
The simulation can now be initiated by pressing the Play button on the Instructor Interface tablet.
RealMom
8
has an opening that enables
: Pusher Inserted
ure the cord is not blocking
lubricate the vaginal area inside and out with Glycerine (or cotton seed oil).
and close the abdomen using the zipper
.
The simulation can now be initiated by pressing the Play button on the Instructor Interface tablet.

RealMom
copyright © 2018 Operative E perience 10002_A
9
All rights reserved
Using the Tablet
As the instructor, you use the tablet to control the simulation, and as the trainee, you’re able to use the
second tablet (or the projected image) to view RealMom’s physiological condition (as well as the fetal
heart rate).
To learn more about the possible physiological settings, see Understanding the OEI Sim Appli ation
below.
Controlling the Simulation with the Instructor Interface
To control the simulator with the Instructor Interface tablet:
1. Power on the simulator by holding down the button on the right shoulder for appro imately two
seconds or until the blue light comes on.
2. Power on the tablet.
3. Connect the tablet to the simulator’s Wi-Fi (see Configuring the Wireless Conne tion above).
4. Start the OEI Sim application.
5. Using the OEI SIM APP set those Physiological Controls appropriate to begin the simulation
(remembering that not all controls are needed for every simulation).
6. Press Play to begin the simulation.
7. During the simulation adjust those Physiological Controls appropriate to the scenario.
8. Press Stop to end the simulation.
9. Click Yes on the dialog bo that appears requesting verification that you wish to end the simulation.
10. Power down the simulator by holding down the button on the right shoulder for appro imately four
seconds. The blue light flashes on and off momentarily before turning off.
All the settings and adjustments you make during the simulation are displayed in the Simulation Log and
remain in the history stored on the Simulation Logs page.
Viewing RealMom’s Condition Using the Trainee Interface Tablet
1. Power on the tablet.
2. Connect the tablet to the simulator’s Wi-Fi (see Configuring the Wireless Conne tion above).
3. Start the OEI Sim application.
4. From the Menu, select Settings.
5. On the Settings page, under Control Interface Type, select the Trainee option from the drop-down
menu for the Interface Type.

RealMom
copyright © 2018 Operative E perience 10002_A
10
All rights reserved
Understanding the OEI Sim Application
When you activate the Instructor tablet, the main screen appears, displaying the fourteen panels of the
OEI Sim application.
Figure 14: The Instructor Tablet’s Main Screen
The panel at the top contains the primary operating controls, the panels below allow you to set the
various physiological features and view an active log of the simulation.

RealMom
copyright © 2018 Operative E perience 10002_A
11
All rights reserved
Using the Operational Panel
At the top of the main screen the uppermost panel displays the Menu button, the Play/Stop button, and
a clock recording the time of the simulation.
Selecting the Menu button opens a menu with five
options related to system operation.
The Instructor option is activated by default, giving
the tablet operator control of the simulator and
displaying the Main Screen.
Selecting the Sim Logs option opens a page with a
history of the simulation logs and the messages
logged for each of these simulations.
Choosing the Settings option displays a page with
controls to set the App Color and the Language
(nglish is selected by default). System Update files
are also uploaded and installed using this option.
Clicking the Diagnostics option opens a page with the
basic Product Information as well as all System
Diagnostics. If necessary, the Shutdown Simulator or
Reboot Simulator functions can be initiated from this
page.
The About option opens a page with the basic details of the system.
Navigation between these pages is available from the menu. For e ample, you can return to the Main
Screen from the Settings page by selecting the Instructor option.
To the right of the menu is the Play/Stop button. When you first activate the Tablet, the Play button is
visible. Once you click Play, the Stop button appears during the simulation.
Figure 16: The Play and Stop Buttons
Clicking the Stop button stops the simulation. A warning bo appears to verify that you wish the
simulation to end.
The clock in the center of the uppermost panel displays the runtime for the simulation. The clock begins
when play is clicked and is stopped when the simulation ends by clicking the Stop button.
Figure 15: The Menu

RealMom
copyright © 2018 Operative E perience 10002_A
12
All rights reserved
Setting the Physiological Controls
Beneath the Operational Panel are twelve panels used to set the vital signs for RealMom and the baby
and to control the baby’s position prior to birth.
Figure 17: Physiological Controls
Once the simulation begins, these controls can be used on the fly to regulate the vital signs apparent to
the trainee. Each of these can be set independently; however, the default settings that automatically
occur when you change the Heart Rate Condition (HR Condition) simultaneously affect multiple
parameters. The Simulation Logs panel records the list of the setting changes along with a timestamp for
each change.
Heart Rate
RealMom’s Heart Rate can be set from 0 to 220 bpm (beats per minute) using the slider bar or by using
the minus the plus (+) controls on either side of the reading.
Figure 18: Setting the Heart Rate
This parameter can be viewed on the Trainee Interface. The heart rate can be changed during the
simulation “on the fly.”

RealMom
copyright © 2018 Operative E perience 10002_A
13
All rights reserved
HR Condition
RealMom’s Heart Rate Condition has four settings, Normal, Tachycardia, Bradycardia, and Palpable.
Click on the panel to activate the menu.
Figure 19: Selecting a Heart Rate Condition
Each setting makes corresponding changes to the Blood Pressure, Heart Rate, Respiratory Rate and
SpO2. Should you choose, these parameters can subsequently be modified using the individual panel
controls.
Heart Rate Condition Blood Pressure Heart Rate Respiratory Rate SpO2
Normal 120 / 60 72 98.5°F 17
Tachycardia 120 / 65 126 102°F 21
Bradycardia 100 / 60 50 98.5°F 13
Palpable 180/130 150 101°F 20

RealMom
copyright © 2018 Operative E perience 10002_A
14
All rights reserved
Bleeding (PPH)
The rate of bleeding for post-partum hemorrhage is controlled using the four settings available when
you click on the Bleeding (PPH) panel: None, Normal, Impressive, and Maximum.
Figure 19: Setting Bleeding
Each setting from None through Maximum increases the amount of blood flowing from the simulator.
Click on the panel to activate the menu.
Other Operative Experience Science Education Product manuals
Popular Science Education Product manuals by other brands

GRAUPNER
GRAUPNER SRVS G490T operating instructions

Assan
Assan GA-250 quick start guide

Alga Science
Alga Science BUBBLEMAKERLAB quick start guide

KOKEN
KOKEN LM-060 instruction manual

Thames & Kosmos
Thames & Kosmos Magnetic Science Experiment manual

Pitsco Education
Pitsco Education Wind Turbine Blade Kit user guide