Optical Systems Design OSD8327 Series User manual

OPERATOR MANUAL
OSD8327 SERIES
HD/SDI AND DATA TX/RX
FIBER OPTIC TRANSMISSION SYSTEM


OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 3
INDEX 1
1
TECHNICAL SUMMARY........................................................................................................4
1.1
BRIEF
DESCRIPTION ............................................................................................................ 4
1.1.1
OVERVIEW............................................................................................................................................. 4
1.1.2
APPLICATIONS...................................................................................................................................... 4
1.1.3
FEATURES AND BENEFITS................................................................................................................. 4
1.2
TYPICAL
CONFIGURATION................................................................................................ 5
1.3
TECHNICAL
SPECIFICATIONS ........................................................................................... 6
2
INSTALLATION AND OPERATION..................................................................................... 7
2.1
INTRODUCTION .................................................................................................................... 7
2.2
INSTALLATION ..................................................................................................................... 7
2.2.1
CABLING ................................................................................................................................................ 7
2.2.2
WARNING AND PRECAUTIONS......................................................................................................... 7
2.2.3
OSD8327 DRAWINGS AND DIMENSIONS......................................................................................... 8
2.2.4
POWER SUPPLY CONNECTIONS ....................................................................................................... 9
2.2.5
HD/SDI CONNECTIONS........................................................................................................................ 9
2.2.6
OPTICAL CONNECTIONS .................................................................................................................. 10
2.2.7
DATA CONNECTIONS........................................................................................................................ 11
2.3
OSD8327
SWITCH
OPERATION......................................................................................... 12
2.3.1
HD/SDI VIDEO SWITCH SETTINGS ................................................................................................. 12
2.3.2
DATA SWITCH SETTINGS................................................................................................................. 13
2.4
LED
INDICATOR
OPERATION .......................................................................................... 14
2.4.1
OSD8327T INDICATORS .................................................................................................................... 14
2.4.2
OSD8327R INDICATORS .................................................................................................................... 15
3
MAINTENANCE...................................................................................................................... 16
3.1
INTRODUCTION .................................................................................................................. 16
3.2
EXTERNAL
INSPECTION ................................................................................................... 16
3.3
ROUTINE
MAINTENANCE................................................................................................. 16
4
WARRANTY ............................................................................................................................ 17
4.1
WARRANTY
PERIOD.......................................................................................................... 17
4.2
REPAIRS................................................................................................................................ 17
4.2.1
WARRANTY REPAIRS........................................................................................................................ 17
4.2.2
OUT-OF-WARRANTY REPAIRS........................................................................................................ 17
4.2.3
SITE REPAIRS ...................................................................................................................................... 17
4.2.4
EXCLUSIONS ....................................................................................................................................... 17
FIGURE 1: OSD8327 TYPICAL CONFIGURATION............................................................................................. 5
FIGURE 2: OSD8327 MOUNTING DIMENSIONS ................................................................................................ 8
FIGURE 3: OSD8327 POWER SUPPLY CONNECTIONS..................................................................................... 9
FIGURE 4: OSD8327T VIDEO CONNECTIONS.................................................................................................... 9
FIGURE 5: OSD8327R VIDEO CONNECTIONS ................................................................................................. 10
FIGURE 6: DATA CONNECTOR PIN ASSIGNMENTS...................................................................................... 11
FIGURE 7: OSD8327T SWITCH SETTINGS........................................................................................................ 12
FIGURE 8: OSD8327R SWITCH SETTINGS........................................................................................................ 12
FIGURE 9: DATA MODE SWITCH SETTINGS .................................................................................................. 13
FIGURE 10: OSD8327T LED INDICATORS ........................................................................................................ 14
FIGURE 11: OSD8327R LED INDICATORS........................................................................................................ 15
TABLE 1: TECHNICAL SPECIFICATIONS........................................................................................................... 6
TABLE 2: OSD8327 DC POWER CONNECTION.................................................................................................. 9
TABLE 3: DATA CONNECTOR PIN ASSIGNMENTS ....................................................................................... 11
TABLE 4: OSD8327T SWITCH SETTINGS ......................................................................................................... 12
TABLE 5: OSD8327R SWITCH SETTINGS ......................................................................................................... 12
TABLE 6: DATA MODE SWITCH SETTINGS .................................................................................................... 13
TABLE 7: RS485 TURNAROUND TIME SWITCH SETTINGS.......................................................................... 13
TABLE 8: OSD8327T LED INDICATORS............................................................................................................ 14
TABLE 9: OSD8327R FRONT PANEL INDICATOR FUNCTIONS ................................................................... 15

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 4
1TECHNICAL SUMMARY
1.1 BRIEF DESCRIPTION
1.1.1 OVERVIEW
The OSD8327 series is a high-quality fiber optic serial digital video (SDI) and data transmission
system. The system consists of the OSD8327T transmitter and the OSD8327R receiver, which are
designed to be used as a pair to reliably transport SDI and duplex serial data over fiber for long
distances using 1310nm, 1510nm and CWDM wavelengths. The OSD8327 pair is suitable for point to
point applications.
The OSD8327T accepts one HD/SDI video input signal. It has a SDI equalizer to effectively
compensate for coaxial cable losses such as the Belden 1694A cable. This allows flexibility for
permanent and temporary installations when SDI source is some distance away from the unit. The user
can disable the equaliser with a toggle switch mounted on the front panel.
Both the OSD8327T and OSD8327R have built-in user bypassable automatic reclocking. The units will
lock at 270Mbps, 1.485Gbps and 2.97Gbps. The user can disable the reclocker with a toggle switch
mounted on the front panel. The OSD8327R has HD/SDI received optical power LED indicators on the
front panel displaying <0dBm, <-6dBm, <-12dBm, <-18dBm and <-24dBm. The OSD8327T and
OSD8327R transmit and receive duplex serial data. Supported data are 2 and 4-wire RS485, TTL,
RS422, Manchester, Biphase and RS232 operation from DC to 1Mbps.
1.1.2 APPLICATIONS
▲
Any digital broadcast application
such as studio signal routing and
temporary OB or studio links
requiring HD/SDI transmission plus
duplex serial data
▲
Very high performance surveillance
networks
1.1.3 FEATURES AND BENEFITS
▲
Basic functionality is that of OSD’s
well established OSD8327T/
OSD8327R HD/SDI link plus the
OSD138 multi-protocol serial data
link
▲
2 and 4-wire RS485, TTL, RS422,
Manchester, Biphase and RS232
operation from DC to 1Mbps
▲
Available with built in user
bypassable automatic reclocking at
270Mbps, 1.485Gbps and 2.97Gbps
▲
Operates from 19.4Mbps to 2.97Gbps
in non-reclocked mode
▲
Compatible with SMPTE 310M,
292M, 259M, 297M, 372M and 424M
▲
Automatic equalisation of up to 350m
@ 270Mbps and 140m @ 1.485Gbps
and 70m @ 2.97Gbps of Belden
1694A cable
▲
Immune to pathological signals
▲
Capable of operation over more than
30km
▲
Capable of running off any
unregulated supply from 10 to 28V
DC
▲
Indication of HD/SDI operating rate

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 5
1.2 TYPICAL CONFIGURATION
Figure 1 below indicates the typical set-up for an OSD8327 system.
FIGURE 1: OSD8327 TYPICAL CONFIGURATION
OSD8327T OSD8327R
1 Fiber
HD/SDI Signal
Source
Monitor with
HD/SDI Interface
λ
λ
Data
Data
OSD8327T OSD8327R
2 Fiber
HD/SDI Signal
Source
Monitor with
HD/SDI Interface
Data
Data
λ
λ
OSD8327T OSD8327R
3 Fiber
HD/SDI Signal
Source
Monitor with
HD/SDI Interface
Data
Data

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 6
1.3 TECHNICAL SPECIFICATIONS
TABLE 1: TECHNICAL SPECIFICATIONS
SPECIFICATION PERFORMANCE
Input/Output Impedance 75Ω
Input/Output Levels 800mVpp nominal
Coax Equalization
350m @ 270Mbps
140m @ 1.485Gbps
70m @ 2.97Gbps
SDI Connectors BNC Female Sockets
Data Rate DC to 1Mbps NRZ
Pulse Distortion and Jitter <±0.3µsec over full dynamic range
Input User selectable between RS422/RS485 levels, TTL on the + input
with – input floating or RS232 levels
User Controls 8-way user adjustable lever switches
HD/SDI Transmitter Wavelength 1310nm ±30nm (1550nm optionally available)
HD/SDI Transmitter Coupled Power -5 to -0dBm (0dBm and +2dBm are optional)
HD/SDI Receiver Sensitivity <-20dBm for 1x10
-9
Bit Error Rate
Data Link Transmitter Wavelength 1310nm ± 30nm or 1510 to 1590nm
Data Link Transmitter Coupled
Power -15 to –12dBm
Data Link Receiver Sensitivity <-37dBm for 1 x 10
-
9
Bit Error Rate
Standard Optical Link Budget >15dB at 1310nm (>30km of singlemode fiber)
Optical Connector ST standard, FC and SC optional
Power Requirements +10 to 28V
DC
Electrical Connectors
9 pin male subminiture D connector for power on card
2 way terminal block with screw clamps for power on module
8 way terminal block with screw clamps or data
Dimensions (mm) 100W x 208D x 25H card
105 x 114 x 32 modem case
Weight 0.3kg (card), 0.8kg (modem case)
Operating Temperature -20°C to +75°C
Relative Humidity 0 to 95% non-condensing
102832702
NOTES:
*Other combinations of laser types and optical levels, receiver types and sensitivity levels are
possible. Contact OSD for details.

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 7
2INSTALLATION AND OPERATION
2.1 INTRODUCTION
This section outlines the methods required to install and operate the OSD8327T and OSD8327R
successfully. It should be studied carefully if damage to the equipment or poor results are to be avoided.
This equipment has been fully tested prior to dispatch and is ready for immediate operation. However it
is advisable to check for external transportation damage before operation. If damage is evident, return
the unit with the packaging to your supplier immediately.
2.2 INSTALLATION
2.2.1 CABLING
Shielded cables should be used on all cabling to provide protection from external electrical events such
as lighting, and switching transients etc. which may cause damage to the unit. All cable shielding must
be grounded at a convenient ground point.
2.2.2 WARNING AND PRECAUTIONS
▲
ELECTROMAGNETIC COMPATIBILITY
WARNING: This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
▲
OPTICAL OUTPUT OPERATION
WARNING: Laser Safety: Class 1 Laser Product per IEC/EN 60825-1:20011 standard.
Class 1
The OSD8327 is a Class 1 laser product.
PRECAUTIONS
▲
All service personnel should be provided training as to the hazards of direct viewing of laser
radiation and of the precautionary measures during servicing of equipment
▲
Areas where laser products are installed should be restricted in access to trained service
personnel only and appropriate warning signs posted in the work area.
▲
All laser apertures should be covered by protective covers when not connected to optical
fibers. Never leave outputs uncovered.
▲
Laser equipment should be positioned above or below eye level where possible. Apertures
should be positioned away from personnel.
▲
Protective eyewear should be worn in the vicinity of laser equipment.

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 8
2.2.3 OSD8327 DRAWINGS AND DIMENSIONS
The OSD8327T and OSD8327R are designed to be mounted on an even surface and to be secured by
means of M4 or smaller screws. The OSD8327T and OSD8327R card versions are designed to be
inserted into a chassis and secured by means of captivated screws.
(a) Module Version
(b) Card Version
FIGURE 2: OSD8327 MOUNTING DIMENSIONS
R2.1
R2.1
Ø8.5
8.0
8.0
DETAIL A
6.0
25.6
104.7
6.0
25.6
DETAIL A
49.5
113.4
31.3
138.4
100.7
25
100
210

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 9
2.2.4 POWER SUPPLY CONNECTIONS
The OSD8327T and OSD8327R require external DC power. The voltage range is +10 to 28V
DC.
Power
should be connected to the power socket located on the front panel of the units and applied as indicated
below;
TABLE 2: OSD8327 DC POWER CONNECTION
External Power Pin Specification
Pin 1 Ground or 0V
Pin 2 +10 to 28V
DC
FIGURE 3: OSD8327 POWER SUPPLY CONNECTIONS
2.2.5 HD/SDI CONNECTIONS
The HD/SDI video-input signal (eg. from camera) is connected to the HD/SDI input BNC connector on
the OSD8327T. The OSD8327T also has two HD/SDI input monitor outputs. Note: The OSD8327T
card version has only one monitor output.
FIGURE 4: OSD8327T VIDEO CONNECTIONS
Power Connector
12
HD/SDI Monitor
HD/SDI Input
HD/SDI Monitor

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 10
The OSD8327R has two HD/SDI BNC output connectors. Note: Figure 5 drawing shows the module
version. The card version is identical except the power connector being a DB9.
FIGURE 5: OSD8327R VIDEO CONNECTIONS
2.2.6 OPTICAL CONNECTIONS
The optical fiber cable must be terminated with the appropriate optical connector. Before connection,
inspect the ends of the connectors to ensure that no dust or dirt is present as it could contaminate the
modem connector and result in poor performance. If it is necessary to clean the cable connectors, use
isopropyl alcohol and lint free tissue to remove contamination.
HD/SDI Monitor
HD/SDI Monitor

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 11
2.2.7 DATA CONNECTIONS
Data signals are connected to the 8-way terminal block connector as set out in Table 3
TABLE 3: DATA CONNECTOR PIN ASSIGNMENTS
8 WAY DATA
TERMINAL BLOCK FUNCTION
1 GROUND
2 RS232 OUTPUT
3 RS232 INPUT
4 RS422 OUTPUT - / RS485 (4W OUTPUT -)
5 RS422 OUTPUT + / RS485 (4W OUTPUT +)
6 GROUND
7 RS422 INPUT - / RS485 (2W I/O, 4W INPUT -)
8 RS422 INPUT + / RS485 (2W I/O, 4W INPUT +)
FIGURE 6: DATA CONNECTOR PIN ASSIGNMENTS
RS485 2-Wire half duplex is used to connect several devices to the same bus when only one unit
transmits data at a time. All units are normally in high impedance receive mode waiting for data. When
transmission of data is requested, the device waits for a protocol specific turn-around time delay before
transmitting after which it returns to receive mode.
RS485 4-Wire full duplex is used for master/slave arrangement. Devices are polled and respond faster
with no turn-around time delay required between request/response. The receiver is always enabled
allowing the devices to receive data even while responding to a request.
Note: If a link doesn't seem to be working correctly (no communication or just one way
communication), try swapping the polarity of the data lines on both ends. Some devices are marked
opposite the RS485 standard.
1 2 3 4 5 6 7 8

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 12
2.3 OSD8327 SWITCH OPERATION
The OSD8327 has an 8-way switch for control of data functions and video functions. These will be
described in two sections, namely HD/SDI video control and data control.
2.3.1 HD/SDI VIDEO SWITCH SETTINGS
The OSD8327T has an Automatic Equalizer (SW8) and Reclocker (SW7) switch located on the front
panel. The OSD8327R has only the Reclocker switch (SW8). The default setting is “on” position.
TABLE 4: OSD8327T SWITCH SETTINGS
OSD8327T
SWITCH STATE POSITION FUNCTION DEFAULT
EQ OFF DOWN Automatic Equalizer Off
ON UP Automatic Equalizer On default*
RCLK OFF DOWN Reclocker Bypassed
ON UP Reclocker Enabled default*
FIGURE 7: OSD8327T SWITCH SETTINGS
TABLE 5: OSD8327R SWITCH SETTINGS
OSD8327R
SWITCH STATE POSITION FUNCTION DEFAULT
RCLK OFF DOWN Reclocker Bypassed
ON UP Reclocker Enabled default*
FIGURE 8: OSD8327R SWITCH SETTINGS
EQ – Automatic Equalizer
RCLK – Reclocker
OFF
ON
1 2 3 4 5 6 7 8
Not Used
RCLK – Reclocker
OFF
ON
1 2 3 4 5 6 7 8

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 13
2.3.2 DATA SWITCH SETTINGS
Six (SW1 to SW6) of the 8-way control switches are used for data control. The 8-way switch is located
at the front of OSD8327 modem.
FIGURE 9: DATA MODE SWITCH SETTINGS
TABLE 6: DATA MODE SWITCH SETTINGS
SWITCH STATE FUNCTION
SW1 OFF RS232/RS422
ON 2 WIRE AND 4 WIRE RS485
SW5 OFF NO BIAS RS485
ON BIAS RS485
SW6 OFF RS232/RS422 OR 4 WIRE RS485
ON INVERSE RS232 OR 2WIRE RS485
Switches SW2, SW3 and SW4 are used for setting RS485 turnaround time.
TABLE 7: RS485 TURNAROUND TIME SWITCH SETTINGS
SW2 SW3 SW4 RS485 TURNAROUND TIME
ON ON ON 10us
ON ON OFF 30us
ON OFF ON 100us
ON OFF OFF 300us
OFF ON ON 1ms
OFF ON OFF 3ms
OFF OFF ON 10ms
OFF OFF OFF 30ms
STD 232/485
Bias
Delay
Delay
Delay
RS232/422/485
OFF
ON
1 2 3 4 5 6 7 8

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 14
2.4 LED INDICATOR OPERATION
2.4.1 OSD8327T INDICATORS
FIGURE 10: OSD8327T LED INDICATORS
TABLE 8: OSD8327T LED INDICATORS
INDICATOR COLOUR FUNCTION
Laser
Red Faulty Laser
Green Laser OK
Carrier
Present
Off SDI source is off or unplugged
Green Carrier Detected
Locked
Off Reclocker not locked or reclocker in bypass mode.
Green Reclocker is locked
Transmit
Data
Off No data transmission
Amber Data transmission
Receive Data
Off No data received
Amber Data received
SDI DATA LOCKED
RATE (Mbps)
2970 1485 - - 270 -
GREEN On On - - On -
BLINKING Optical Transceiver Error
Transmit Data
Not Used
270Mbps
Not Used
Not Used
1485Mbps
2970Mbps
Receive Data
SDI Data Rate
Laser OK
Carrier Present
Locked

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 15
2.4.2 OSD8327R INDICATORS
FIGURE 11: OSD8327R LED INDICATORS
TABLE 9: OSD8327R FRONT PANEL INDICATOR FUNCTIONS
INDICATOR COLOUR FUNCTION
Carrier Present
Off SDI source is unplugged
Green Carrier Detected
Locked
Off Reclocker not locked or reclocker in bypass mode.
Green Reclocker is locked
Optical Signal
Loss
Red No optical signal
Off Optical Power above –27dBm
0dBm Green Optical Power above 0dBm
-6dBm Green Optical Power above –6dBm
-12dBm Green Optical Power above –12dBm
-18dBm Green Optical Power above –18dBm
-24dBm Green Optical Power above –24dBm
Transmit Data
Off No data transmission
Amber Data transmission
Receive Data
Off No data received
Amber Data received
SDI DATA LOCKED
RATE (Mbps)
2970 1485 - - 270 -
GREEN On On - - On -
BLINKING Transmit Error
Transmit Data
Not Used
270Mbps
Not Used
Not used
1485Mbps
2970Mbps
Receive Data
>-24dBm
>-18dBm
>-12dBm
>-6dBm
>-0dBm
Carrier Present
Locked
Optical Signal Loss

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 16
3MAINTENANCE
3.1 INTRODUCTION
The following section outlines the fault-finding procedure for the OSD8327T and OSD8327R modems.
Please take note of the following:
▲
Personnel without appropriate training should not attempt any maintenance except that outlined
below.
▲
If further maintenance is attempted you are warned that every care should be taken to ensure that
internal measurements made while the equipment is operational are taken carefully as some
components within the unit are expensive and may be damaged by failure of any portion of their
support circuitry.
▲
Some components within the unit are Electrostatic (ES) sensitive and Electrostatic Discharge
(ESD) precautions should be taken when performing maintenance upon the unit.
3.2 EXTERNAL INSPECTION
Visually check for the following:
▲
Check that the correct power source is connected to the power socket.
▲
Check that the HD/SDI and data signals are connected to the modem correctly and that the distant
OSD8327T or OSD8327R modem has been terminated correctly to any external equipment.
▲
Inspect the optical connectors for any contamination and clean using isopropyl alcohol and a lint
free tissue if any contamination is detected.
▲
Check that any external termination resistors are connected if the system configuration requires
them.
3.3 ROUTINE MAINTENANCE
▲
There is no routine maintenance required with the OSD8327T and OSD8327R.

OPTICAL SYSTEMS DESIGN
DOC ID: 10116601
OSD8327 OPERATOR MANUAL
PAGE 17
4WARRANTY
Thank you for purchasing equipment designed, manufactured and serviced by Optical Systems Design
(OSD). OSD warrants that at the time of shipment, its products are free from defects in material and
workmanship and conforms to specifications. Our Warranty conditions are outlined below:
4.1 WARRANTY PERIOD
For warranty period, please call your local OSD distributor.
4.2 REPAIRS
Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a
“Return Material Authorisation” (RMA) form and number before returning goods.
Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its
nominated authorised representative, for all repairs.
4.2.1 WARRANTY REPAIRS
Return shipments to OSD shall be at customer's expense and freight back to the customer will be at
OSD expense.
4.2.2 OUT-OF-WARRANTY REPAIRS
OSD reserves the right to repair or replace any faulty goods. Freight costs and insurance for both
journeys are met by the user. All equipment repaired by OSD will have a 3-Month Warranty from the
date of dispatch.
4.2.3 SITE REPAIRS
By agreement site repairs may be undertaken for which out of pocket, hotel and travel expenses will be
charged.
4.2.4 EXCLUSIONS
This warranty does not apply to defects caused by unauthorized modifications, misuse, abuse or
transport damage to the equipment. All modifications to OSD’s standard product will need written
authorization and will be charged at normal repair rates. All modifications are to be carried out by OSD
Technicians. Warranty is void if unauthorized removal and/or tampering with serial number and/or
labels is evident.



Optical Systems Design Pty. Ltd.
7/1 Vuko Pl. Warriewood 2102
P.O. Box 891 Mona Vale
N.S.W. Australia 2103
Telephone: +61 2 9913 8540
Facsimile: +61 2 9913 8735
Email: sales@osd.com.au
Web Site: www.osd.com.au
OPTIC L
SYSTEMS
DESIGN
PTY LTD A.B.N. 83 003 020 504
Printed in Australia
This manual suits for next models
2
Table of contents