SETUP AND PROGRAMMING
Buttons
Button Symbol
Description
MENU
Press and hold the MENU button for 3 seconds to enter or exit the
Programming Mode at any time. SD-Card can be inserted into the unit when
the backlight is on in order to download the internally logged data.
Up arrow/MAX
Press the Up arrow/MAX button to scroll through the menus or to increment
the value of a digit.
Right arrow/RESET
Press the Right arrow/RESET button to access a submenu, move to the next
digit when entering a value, or adjust decimal position during programming.
Return/ACK
Press the Return/Ack to return to the parent menu of a submenu.

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 2 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Main Menu Display Functions & Messages
The meter displays various functions and messages during setup, programming, and operation. The
following table shows the main menu functions and messages in the order they appear in the menu.
Each of the menu items shown below has a corresponding submenu that is used to adjust the associated
setting. Settings adjusted in each submenu are saved immediately after a change is made and there is
no need to hit any other keys to ‘lock in’ the change. If a submenu has multiple items to choose from,
each item can be browsed one at a time using the Up arrow button. Hitting the Up arrow button when
at the last item will restart the item display at the first item.
Display
Action/Setting
Volume Units
Enter the Volume Units menu where selection from Gallons, Liters, ft3 (cubic feet),
m3 (cubic meters) can be made
K Factor
Enter the K Factor Value menu where the K-Factor value (in terms of the selected
Volume Units) can be programmed
Rate Meter
Scaling
Enter the Rate Meter Scaling menu where selection from /sec (seconds), /min
(minutes), /hour (hours) can be made.
Flow Rate Units
Enter the Volume Units menu where selection from Gallons, Liters, ft3 (cubic feet),
m3 (cubic meters) can be made
MODBUS
Enter the MODBUS address where selection from 1-99 can be made

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 3 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Main Menu
The Main Menu displays 8 fields providing information regarding the meter operation.
Field
Description
Volume
Displays the meters totalized volume
Volume Units
Displays the units of the totalized volume (as set in the Volume Units menu)
Flow Rate
Displays the flow rate (metered volume divided by the Rate Meter Scaling)
Rate Meter
Scaling
Displays the rate units the flow is measured over (as set in the Rate Meter Scaling
menu)

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 4 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Setting Numeric Values
The numeric values are set using the Right and Up arrow buttons. Press Right arrow to select next digit
and Up arrow to increment the digit.
An arrow will appear on the LCD below the digit currently being changed.
The Up arrow will cycle between digits ‘0’ through ‘9’ and a decimal point ‘.’ if a decimal point has not
yet been placed. The decimal point is optional but if selected can only be chosen once. If the decimal
point is to be repositioned, then the current position of the decimal point must be replaced with a digit
and the new position of the decimal point can then be selected.
Menu Parameters
K Factor Value
1.34567890
^
Menu Parameters
K Factor Value
1.34567890
^
Select Next Digit Increment Digit
Menu Parameters
K Factor Value
1.35567890
^
Accessing the Menu
To access the menu, hold down the MENU button for 3 seconds.

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 5 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Setting the Volume Units
The Volume Units menu is used to select the volume units to be totalled. The Up arrow button will cycle
through the volume units available.
Press and hold for 3
seconds Menu Parameters
Volume Units
Select Submenu
Menu Parameters
Volume Units
Gallons
Menu Parameters
Volume Units
Liters
Select Next Value Select Next Value
...
Setting the K Factor
The K Factor menu is used to program the flow coefficient (expressed in pulses per unit volume) that is
used to convert input pulses to the Volume on the display. It is important to note that the K Factor
programmed must have the same unit volume as specified in the Volume Units menu or the incorrect
totalized volume may be displayed. Setting of the K Factor is done as described in the Setting Numeric
Values section above.
Menu Parameters
K Factor Value
1.34567890
^
Menu Parameters
K Factor Value
1.34567890
^
Select Next Digit Increment Digit
Menu Parameters
K Factor Value
1.35567890
^
Press and hold for 3
seconds Menu Parameters
Volume Units
Select Submenu
Select Next Menu
Menu Parameters
K Factor

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 6 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Setting the Rate Meter Scaling
The Rate Meter Scaling menu is used to select the time over which the volume should be measured
(resulting in the Flow Rate). The Up arrow button will cycle through the volume units available.
Press and hold for 3
seconds Menu Parameters
Volume Units
Select Next Menu
Menu Parameters
K Factor
Menu Parameters
Rate Meter Scaling
/sec
Select Submenu
Select Next Menu
Menu Parameters
Rate Meter Scaling
Select Next Value
...

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 7 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Setting the Flow Rate Units
The Flow Rate Units menu is used to select the volume units to be totalled. The Up arrow button will
cycle through the volume units available.
Press and hold for 3
seconds Menu Parameters
Volume Units
Select Submenu
Menu Parameters
Volume Units
Gallons
Menu Parameters
Volume Units
Liters
Select Next Value Select Next Value
...
Pulse Output
The pulse output will be pulsed with each complete volume unit received. If the Volume Units chosen
are Gallons, then the output pulse will pulse once for every gallon received. The maximum pulse output
frequency is 18 Hz. If the pulse output exceeds 18 Hz, pulses are accumulated and the pulse output will
continue until all accumulated pulses have been output

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 8 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
MODBUS Communication
+
+12V Power Input
E
RS-485 Enable
B
RS-485 B
A
RS-485 A
G
Ground
Setting the MODBUS Address
The MODBUS Address menu is used to select the starting address of the 6 registers supported. The Up
arrow button will cycle through addresses from 1-99. RTU protocol is used.
Press and hold for 3
seconds Menu Parameters
MODBUS Address
1
Select Submenu
Menu Parameters
MODBUS Address
2
Menu Parameters
MODBUS Address
3
Select Next Value Select Next Value
...
The 6 MODBUS registers are organized as:
•0 and 1 are a long value of seconds.
•2 and 3 are a float value of total volume.
•4 and 5 are a float value of flow rate.

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 9 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Jumper Settings
To externally enable RS-485 set jumper to the Enable ON Position.
To have RS-485 always on set this jumper to Always ON Position
Notes:
Both jumpers to the left for mag flow type meters.
Both jumpers to the right for turbine type flow meters
Change 100k pull-up to 2.2k pull up for mag flow type meters

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 10 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Setting the Unit Number
A Unit Number/Serial Number can be set for the unit to aid with organizing log files. To change a unit
number for a meter head you have to make a CONFIG.TXT file on an SD-card. Ensure Windows is
showing file extensions as by default they are turned off and you will end up with a CONFIG.TXT.txt file
name. All upper case is important.
Next open up the file with Notepad or similar and put in a 6 digit unit number all by itself in the file such
as: “929123” or “000004”
Save the file and then remove your SD-card from your computer. Insert the SD-card into the meter head
after pressing MENU to wake the unit and let it go through a download process. It should then create a
new log file with the correct number for you to verify.

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 11 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Formatting Internal Memory for Use
Formatting the internal memory must be done once for the logging to function properly. In order to
clear all internal logged data and format the memory hold down RETURN while applying power and
keep RETURN held down until you see “Clearing Logged Data” after which you can then let go of the
button.
This process will take a few minutes and once it has completed, the unit will be in a test ready mode.
Cycle the power until the Sample number shows greater than 40 to begin use!
A Sample number greater than 40 indicates that the meter is ready to use. Sample numbers below 40
will loop through internal memory as it is in a test ready mode.

optinst.com viewdatanow.com datadolphin.com emailalarm.com
Optimum
Instruments Inc.
Innovations in Data Collection
- 12 -
Tel: (1) 780-450-0591•Fax: (1) 780-440-2515
www.datadolphin.com
E-mail: optimum@datadolphin.com
Data Dolphin Installation Manual
DD-METER
Downloading Internal Memory
Formatting the internal memory must be done once for the logging to work correctly. The unit must also
be in run mode.
Insert the SD-card into the meter head after pressing MENU to wake the unit and it will go through the
download process. Once it has finished, eject the SD card and insert it into your computer. On the SD
card there will be a log file with the unit number that can be copied and opened into Excel. You may
need to sort the date/time column for the data to line up for use.
Table of contents
Other Optimum Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Techmed
Techmed TM-H user manual

Blackmagicdesign
Blackmagicdesign HyperDeck Shuttle HD Installation and operation manual

Accu-Flo Meter Service Ltd.
Accu-Flo Meter Service Ltd. RED SEAL MEASUREMENT neptune Operating and maintenance

AlertLabs
AlertLabs SENTREE Safety and installation

Hi-Tec
Hi-Tec LiPo Checker quick start guide

Smart Witness
Smart Witness CP4 Configuration guide