Fold the metal spring of the sensor to upwards, until they are in “I” position with sensor, then
put the sensor into the hole or installation box which is in the ceiling, the size is similar with
item. Releasing the spring, the sensor will be set in this installation position.
After finishing installing, the sensor could be connected the power and is ready for test.
STEP 1
STEP 2
STEP 3
Turn the TIME knob anti-clockwise on the minimum,
turn the LUX knob clockwise on the maximum (sun).
Turn on the power, let the sensor to warm-up for 30
sec, the item will be entered into working estate.
5~10 seconds after the light goes down for the first
time and then sensor is activated, the load should
operate.
Turn LUX knob anti-clockwise on the minimum (moon). The inductor load should not work
after load stop working. If you cover the detection window with an opaque objects (towel etc),
the load work under no induction signal condition, the load should stop working within
5-15sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise
the sensor lamp could not work!
NOTE:
Should be installed by electrician or experienced man.
Avoid installing it on unstable surface.
There shouldn’t be any object to obstruct and/or moving body in front of the detection
screen effecting detection.
Avoid installing it near air temperature alteration zones such as air conditioner, central
heating, etc.
Considering your safety, please don’t open the cover after the power is on.
TROUBLESHOOTING:
The load don’t work:
a. Please check the power and load connections are correct.
b. Check if the load is functioning.
c. Check if the working light corresponds to the ambient light.
The sensitivity is poor:
a. Please check if there is an object in front of the detection window effecting
reception of the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the signals source is in the detection fields.
d. Please check if the installation height corresponds to the height showed in the
instruction.
The sensor can’t shut the load automatically:
a. Check if there are continual signals in the detection fields.
b. Check if the time delay is set to the longest.
c. Check if the power corresponds to the instruction.
d. Check if the temperature change obviously nears the sensor, such as air condition
or central heating etc.