SE7301, SE7302
Thank you for purchasing SE7302 Infrared motion sensor!
This product is a new type of energy-saving lighting switch, it
combines high sensitivity detector, integrated circuit and SMT; This product is convenient, safe,
energy-saving and practical; It has wide detection range; It is based on motion detecting infrared
rays, control signal sources, so that if a movement is detected within the operations field, it will
start providing power at once; It can identify day and night automatically; It is easy to install with
wide field of application; It has the function of power indication and detection indication.
TECHNICAL SPECIFICATIONS:
Power Source: 220V/AC-240V/AC Detection Range: 180º
Power Frequency: 50Hz Working Temperature: -20~ +40℃
Ambient Light:10-2000LUX (adjustable) Working Humidity: <93%RH
Time-Delay: min:10 sec±3sec Installation Height: 1.8m~2.5m
max:7min±3min Power Consumption: <0.9W (work)
Rated Load: 1200W (incandescent lamp) <0.9W(static)
300W (energy-saving lamp) Detection Moving Speed: 0.6~1.5m/s
Detection Distance: 12m max (<24℃)
FUNCTIONALITY:
➢Detection field: The wide detection range is made up of up and down, left and right
operational fields (see the diagram below), the detection range could be adjusted according
to the particular requirements, but the moving orientation in detection field is co-related to the
sensitivity.
➢Identifying day and night automatically: The ambient light of SE7301, SE7302 could be
adjusted according to the particular requirements: when turn to SUN (max), it will work day
and night, when turn it to MOON (min), it will only work in the ambient light less than 10LUX.
➢Time-delay is added continually: When it receives the second induction signals after the first
induction, it will compute time once more on the rest of the first time-delay basis (set time).
➢Time-delay is adjustable: It can be set according to your needs, the minimum is 10
sec±3sec,the maximum is 7min±3min.
Good sensitivity Poor sensitivity
INSTALLATION: (see the diagram)
➢Disconnect electrical power supply.
➢Loosen the screw on the bottom lid, open
the wiring hole, pass the power wire and
connect through the bottom lid.
➢Fix the bottom lid with inflated screw on the
selected position.
➢Connect the power cable to the terminal
block as shown on the figure below.
➢Put the sensor on the bottom lid, close the screw tightly then electrify it and test it.
CONNECT-WIRE DIAGRAM
(See the figure on the right side)
TEST:
➢Turn time knob anti-clockwise to the minimum setting
position; turn the LUX knob clockwise to the maximum
(SUN), Turn on electricity power, the controlled load will
not initially work, needing to preheat within 5-30 sec.
➢The sensor will commence operating in 5-10 sec; then
sensor is activated when receive moving signal and stop
working within 7-13sec without any other sensor signal.
➢Turn LUX knob to minimum anti-clockwise setting, if you test it when the ambient light is
more than 3LUX, the induction load would not work after the load stops working; the load
should work if you cover the detection screen, it should stop working within 7-13sec under
no induction signal condition.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor will not work!
NOTE:
➢This product should be installed by qualified electrician only.
➢Do not install this product on unsafe or unstable surface.
➢There should be no hindrance and/or moving objects in front of the detection screen to
disturb the detection.
➢Avoid installing this product near air temperature alteration zones such as air conditioning,
central heating, etc.
➢For your safety, do not disassemble.
➢Always read the safety icons on the product.
TROUBLESHOOTING:
➢In case of malfunction:
a. please check if the connection-wiring is correct.
b. please check if the power load is adequate .
c. please check if the working light set corresponds to ambient light.
➢The sensitivity is poor:
a. Please check if there is an obstacle in front of the detection screen which obstructs
the signal.
b. Please check if the ambient temperature is within optimum working parameters.
c. Please check if the induction signal source is in the detection fields.
d. Please check if the installation height corresponds to the height prescribed in the
instruction.
e. Please check if the moving orientation is correct.
➢The sensor cannot shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check the time delay settings.
c. Please check if the power supply corresponds to the instruction.
d. Please check if the temperature near the sensor tends to change abruptly, such as
in cases of proximity to air conditioner or central heating sources etc.

This manual suits for next models

1

Other optonica Accessories manuals

optonica 7312 User manual

optonica

optonica 7312 User manual

optonica 7318 User manual

optonica

optonica 7318 User manual

optonica 7317 User manual

optonica

optonica 7317 User manual

optonica 7322 User manual

optonica

optonica 7322 User manual

optonica 7306 MINI User manual

optonica

optonica 7306 MINI User manual

Popular Accessories manuals by other brands

ELICA Marie Operation manual

ELICA

ELICA Marie Operation manual

Siemens SIMATIC VS130-2vcr installation instructions

Siemens

Siemens SIMATIC VS130-2vcr installation instructions

Peavey Mentor manual

Peavey

Peavey Mentor manual

Bona VIKING GO20 user manual

Bona

Bona VIKING GO20 user manual

BOMANN KSG 7283.1 instruction manual

BOMANN

BOMANN KSG 7283.1 instruction manual

DELTA DORE Tywatt 5450 user manual

DELTA DORE

DELTA DORE Tywatt 5450 user manual

GUDIMALIGHT SANI UV-C user manual

GUDIMALIGHT

GUDIMALIGHT SANI UV-C user manual

Orno OR-GM-9027 quick start guide

Orno

Orno OR-GM-9027 quick start guide

Craftsman 486.24275 owner's manual

Craftsman

Craftsman 486.24275 owner's manual

Vishay TSSP96038TR manual

Vishay

Vishay TSSP96038TR manual

Edimax AI-1001W V2 Quick installation guide

Edimax

Edimax AI-1001W V2 Quick installation guide

Hoftronic 4401306 user manual

Hoftronic

Hoftronic 4401306 user manual

Unex 50 Series Mounting instruction

Unex

Unex 50 Series Mounting instruction

Swing Caddie SC100 user manual

Swing Caddie

Swing Caddie SC100 user manual

Honeywell 4AV15F installation instructions

Honeywell

Honeywell 4AV15F installation instructions

Fastus Z3 Series instruction manual

Fastus

Fastus Z3 Series instruction manual

Baumer UNDK 20N6914/S35A manual

Baumer

Baumer UNDK 20N6914/S35A manual

Yamaha SP02R96 owner's manual

Yamaha

Yamaha SP02R96 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.