optonica T13 User manual

● Touch panel 4 zone 1-4 color DMX512 master, can also be used as 4 zone 1-4 color RF remote.
● DMX signal output, comply to standard DMX512 protocol, compatible with DMX decoder from any supplier.
● When used as RF remote, each zone can remote control multiple Skydance’s 2.4G LED controllers.
● Ultra sensitive high strength glass touch panel with touch color wheel in the middle and backlighting.
● Smooth and accurate color adjustment by touching the color wheel.
● Touch keys with chord tones and LED indicator.
Output signal DMX512, RF 2.4GHz
Input voltage 85-265VAC
Input current Max 0.1A
User Manual Ver 1.0.6
Operation temperature
Case temperature (Max.)
Environment
IP20
IP rating
Dimming data
Dimming range
Touch key + RF 2.4GHz
30m
256 levels
0 -100%
Technical Parameters
Input and Output
Safety and EMC
EMC standard (EMC) EN301 489,EN 62479
Radio Equipment(RED) EN300 328
Certification CE,EMC,LVD,RED
EN60950
Safety standard(LVD)
Warranty
5 years
Warranty
Input signal
RF Control distance
Dimming level
Ta: -30
O
C ~ +55
O
C
T c: +85
O
C
Model No.: T11,T12,T13,T14
4 Zone/1-4 color/Glass touch panel/Color wheel/AC input/DMX 512 and RF 2.4G signal output
Features
Page 1
Mechanical Structures and Installations
Wall Mounted Touch Panel
LVD RED
LNGNDD+ D-
DMX O UTPUT
INP UT
85- 265 VAC
T11/ T12
T13/T14
DMX output +
DMX output -
DMX signal GND
AC input L
AC input N
T14T13T12
T11
11.5 mm
86m m
86m m
59m m
62m m
35m m
45. 5 mm
Light type
Output DMX channel number
Model No. T14
T13
T12
T11
Dual color RGB RGBW
4812 16
Typical base as below:
European style 86 size
Touch panel Baseplate Base
Uninstall
Installation diagram:
Single color
T13 RGB panel
Turn on/off all zone light.
MOD E
SPE ED
BRI GHT
SCE NE
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Adjust dynamic mode speed or RGB color saturation, 10 levels.
Adjust brightness, 10 levels.
Short press replay scene. Long press 2s to save the current color into the scene.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
T14 RGBW panel
Note: After touch power key to turn off light, long press power key for 5 seconds will turn on or turn off tone.
Turn on/off all zone light.
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
MOD E
BRT /SP EED Adjust dynamic mode speed or static color brightness,10 levels.
WHI TE
BLU EGRE EN
RED Short press get red,green,blue,white color,
long press adjust each color brightness.
T11,T12,T13,T14 Wall Mounted Touch Panel
T11 Single color panel
T12 Dual color panel
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
Brightness wheel.
Brightness,10 levels.
Turn on/off all zone light.
POW ER
BRI GHT
ZON E ZON E ZON E ZON E
Turn on/off all zone light.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
Key function
WHITEBLUE
GREEN
RED
MODE BRT/SPEED
ZONE ZONE ZONE ZONE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
ZONE ZONE ZONE ZONE
MODE BRIGHTSPEED
S
SCENE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
Brightness,10 levels.
Color temperature wheel.
BRIGHT

● Touch panel 4 zone 1-4 color DMX512 master, can also be used as 4 zone 1-4 color RF remote.
● DMX signal output, comply to standard DMX512 protocol, compatible with DMX decoder from any supplier.
● When used as RF remote, each zone can remote control multiple Skydance’s 2.4G LED controllers.
● Ultra sensitive high strength glass touch panel with touch color wheel in the middle and backlighting.
● Smooth and accurate color adjustment by touching the color wheel.
● Touch keys with chord tones and LED indicator.
Output signal DMX512, RF 2.4GHz
Input voltage 85-265VAC
Input current Max 0.1A
User Manual Ver 1.0.6
Operation temperature
Case temperature (Max.)
Environment
IP20
IP rating
Dimming data
Dimming range
Touch key + RF 2.4GHz
30m
256 levels
0 -100%
Technical Parameters
Input and Output
Safety and EMC
EMC standard (EMC) EN301 489,EN 62479
Radio Equipment(RED) EN300 328
Certification CE,EMC,LVD,RED
EN60950
Safety standard(LVD)
Warranty
5 years
Warranty
Input signal
RF Control distance
Dimming level
Ta: -30
O
C ~ +55
O
C
T c: +85
O
C
Model No.: T11,T12,T13,T14
4 Zone/1-4 color/Glass touch panel/Color wheel/AC input/DMX 512 and RF 2.4G signal output
Features
Page 1
Mechanical Structures and Installations
Wall Mounted Touch Panel
LVD RED
LNG NDD+ D-
DMX O UTPUT
INP UT
85- 265 VAC
T11/ T12
T13/T14
DMX output +
DMX output -
DMX signal GND
AC input L
AC input N
T14T13T12
T11
11.5 mm
86m m
86m m
59m m
62m m
35m m
45. 5 mm
Light type
Output DMX channel number
Model No. T14
T13
T12
T11
Dual color RGB RGBW
4812 16
Typical base as below:
European style 86 size
Touch panel Baseplate Base
Uninstall
Installation diagram:
Single color
T13 RGB panel
Turn on/off all zone light.
MOD E
SPE ED
BRI GHT
SCE NE
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Adjust dynamic mode speed or RGB color saturation, 10 levels.
Adjust brightness, 10 levels.
Short press replay scene. Long press 2s to save the current color into the scene.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
T14 RGBW panel
Note: After touch power key to turn off light, long press power key for 5 seconds will turn on or turn off tone.
Turn on/off all zone light.
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
MOD E
BRT /SP EED Adjust dynamic mode speed or static color brightness,10 levels.
WHI TE
BLU EGR EEN
RED Short press get red,green,blue,white color,
long press adjust each color brightness.
T11,T12,T13,T14 Wall Mounted Touch Panel
T11 Single color panel
T12 Dual color panel
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
Brightness wheel.
Brightness,10 levels.
Turn on/off all zone light.
POW ER
BRI GHT
ZON E ZON E ZON E ZON E
Turn on/off all zone light.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
Key function
WHITEBLUE
GREEN
RED
MODE BRT/SPEED
ZONE ZONE ZONE ZONE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
ZONE ZONE ZONE ZONE
MODE BRIGHTSPEED
S
SCENE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
Brightness,10 levels.
Color temperature wheel.
BRIGHT

● Touch panel 4 zone 1-4 color DMX512 master, can also be used as 4 zone 1-4 color RF remote.
● DMX signal output, comply to standard DMX512 protocol, compatible with DMX decoder from any supplier.
● When used as RF remote, each zone can remote control multiple Skydance’s 2.4G LED controllers.
● Ultra sensitive high strength glass touch panel with touch color wheel in the middle and backlighting.
● Smooth and accurate color adjustment by touching the color wheel.
● Touch keys with chord tones and LED indicator.
Output signal DMX512, RF 2.4GHz
Input voltage 85-265VAC
Input current Max 0.1A
User Manual Ver 1.0.6
Operation temperature
Case temperature (Max.)
Environment
IP20
IP rating
Dimming data
Dimming range
Touch key + RF 2.4GHz
30m
256 levels
0 -100%
Technical Parameters
Input and Output
Safety and EMC
EMC standard (EMC) EN301 489,EN 62479
Radio Equipment(RED) EN300 328
Certification CE,EMC,LVD,RED
EN60950
Safety standard(LVD)
Warranty
5 years
Warranty
Input signal
RF Control distance
Dimming level
Ta: -30
O
C ~ +55
O
C
T c: +85
O
C
Model No.: T11,T12,T13,T14
4 Zone/1-4 color/Glass touch panel/Color wheel/AC input/DMX 512 and RF 2.4G signal output
Features
Page 1
Mechanical Structures and Installations
Wall Mounted Touch Panel
LVD RED
LNGNDD+ D-
DMX O UTPUT
INP UT
85- 265 VAC
T11/ T12
T13/T14
DMX output +
DMX output -
DMX signal GND
AC input L
AC input N
T14T13T12
T11
11.5 mm
86m m
86m m
59m m
62m m
35m m
45. 5mm
Light type
Output DMX channel number
Model No. T14
T13
T12
T11
Dual color RGB RGBW
4812 16
Typical base as below:
European style 86 size
Touch panel Baseplate Base
Uninstall
Installation diagram:
Single color
T13 RGB panel
Turn on/off all zone light.
MOD E
SPE ED
BRI GHT
SCE NE
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Adjust dynamic mode speed or RGB color saturation, 10 levels.
Adjust brightness, 10 levels.
Short press replay scene. Long press 2s to save the current color into the scene.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
T14 RGBW panel
Note: After touch power key to turn off light, long press power key for 5 seconds will turn on or turn off tone.
Turn on/off all zone light.
Color wheel.
Short press play 10 built-in mode, long press 2s run mode-cycle.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
MOD E
BRT /SP EED Adjust dynamic mode speed or static color brightness,10 levels.
WHI TE
BLU EGRE EN
RED Short press get red,green,blue,white color,
long press adjust each color brightness.
T11,T12,T13,T14 Wall Mounted Touch Panel
T11 Single color panel
T12 Dual color panel
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
Brightness wheel.
Brightness,10 levels.
Turn on/off all zone light.
POW ER
BRI GHT
ZON E ZON E ZON E ZON E
Turn on/off all zone light.
Short press turn on zone light and select zone simultaneously, long press 2s turn off zone light.
4 zone control seperately or synchronously, each zone could control multiple receivers.
ZON E ZON E ZON E ZON E
Key function
WHITEBLUE
GREEN
RED
MODE BRT/SPEED
ZONE ZONE ZONE ZONE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
ZONE ZONE ZONE ZONE
MODE BRIGHTSPEED
S
SCENE
POWER
BRIGHT
ZONE ZONE ZONE ZONE
Brightness,10 levels.
Color temperature wheel.
BRIGHT

D4-L
DMX512 & RDM Decoder
D+D- D-D+
AC100-240V
Power Supply
12-24VDC
Constant Voltage
LN
INPU T
85-2 65VAC
AC85-265V
GNDD+ D-
DMX OU TPUT
DMX signal
T14
Wiring Diagram for touch panel work as DMX512 master
Touch Panel work as DMX512 Master
After connect with DMX decoders, please set the DMX decoders address as below:
+
For T14 RGBW panel
Each zone 4 channel:
zone 1 is channel 1 ~ 4,
zone 2 is channel 5 ~ 8,
zone 3 is channel 9 ~ 12,
zone 4 is channel 13 ~ 16,
channel 1,5,9,13 is R,
channel 2,6,10,14 is G,
channel 3,7,11,15 is B,
channel 4,8,12,16 is W.
RGBW LED strip
R
G
B
W
Touch Panel work as RF remote (two match ways)
Use the controller’s Match key
Match:
Short press match key, immediately press Zone
key of the touch panel.
Use Power Restart
Match:
Switch off the power of the receiver, then switch on power again,
immediately short press Zone key 3 times on the touch panel.
The light blinks 3 times means match is successful.
.
Delete:
Switch off the power of the receiver, then switch on power again,
immediately short press Zone key 5 times on the touch panel.
The light blinks 5 times means all matched remotes were deleted.
Delete:
Press and hold match key for 5s to delete all match,
The light blinks 5 times means all matched remotes
were deleted.
End user can choose the suitable match/delete ways. Two options are offered for selection:
Wiring Diagram for touch panel work as RF remote
LN
INPU T
85-2 65VAC
AC85-265V
GNDD+ D-
DMX OU TPUT
T11/ T12
T13/T14
Malfunctions analysis & troubleshooting
User Manual Ver 1.0.6 Page 2
Causes Troubleshooting
1. No power.
2. Wrong connection or insecure.
1. Check the power.
2. Check the connection.
1. DMX decoder first address error.
2. Wrong connection of output wires.
1. Check the DMX first address.
2. Reconnect output wires.
Wrong color
Malfunctions
No light
CW CW
Zone 1 DMX decoder’s address
Model No. T14
T13T12T11
1 2 1 2 3 1 2 3 4
23 4 4 5 6 5 6 7 8
Zone 2 DMX decoder’s address
Zone 3 DMX decoder’s address
Zone 4 DMX decoder’s address
1
5 6 7 8 9 9 10 11 12
47 8 10 11 12 13 14 15 16
3
WW CW R G B R G B W
T11,T12,T13,T14 Wall Mounted Touch Panel
IMPORTER: Prima Group 2004 LTD, Bulgaria, 1784 Sofia, Mladost 1, bl. 144, Ground Floor; Phone: +359 2 988 45 72;

D4-L
DMX512 & RDM Decoder
D+D- D -D+
AC100-240V
Power Supply
12-24VDC
Constant Voltage
LN
INPU T
85- 265VA C
AC85-265V
GNDD+ D-
DMX O UTPUT
DMX signal
T14
Wiring Diagram for touch panel work as DMX512 master
Touch Panel work as DMX512 Master
After connect with DMX decoders, please set the DMX decoders address as below:
+
For T14 RGBW panel
Each zone 4 channel:
zone 1 is channel 1 ~ 4,
zone 2 is channel 5 ~ 8,
zone 3 is channel 9 ~ 12,
zone 4 is channel 13 ~ 16,
channel 1,5,9,13 is R,
channel 2,6,10,14 is G,
channel 3,7,11,15 is B,
channel 4,8,12,16 is W.
RGBW LED strip
R
G
B
W
Touch Panel work as RF remote (two match ways)
Use the controller’s Match key
Match:
Short press match key, immediately press Zone
key of the touch panel.
Use Power Restart
Match:
Switch off the power of the receiver, then switch on power again,
immediately short press Zone key 3 times on the touch panel.
The light blinks 3 times means match is successful.
.
Delete:
Switch off the power of the receiver, then switch on power again,
immediately short press Zone key 5 times on the touch panel.
The light blinks 5 times means all matched remotes were deleted.
Delete:
Press and hold match key for 5s to delete all match,
The light blinks 5 times means all matched remotes
were deleted.
End user can choose the suitable match/delete ways. Two options are offered for selection:
Wiring Diagram for touch panel work as RF remote
LN
INPU T
85- 265VA C
AC85-265V
GNDD+ D-
DMX O UTPUT
T11/ T12
T13/T14
Malfunctions analysis & troubleshooting
User Manual Ver 1.0.6 Page 2
Causes Troubleshooting
1. No power.
2. Wrong connection or insecure.
1. Check the power.
2. Check the connection.
1. DMX decoder first address error.
2. Wrong connection of output wires.
1. Check the DMX first address.
2. Reconnect output wires.
Wrong color
Malfunctions
No light
CW CW
Zone 1 DMX decoder’s address
Model No. T14
T13T12T11
1 2 1 2 3 1 2 3 4
23 4 4 5 6 5 6 7 8
Zone 2 DMX decoder’s address
Zone 3 DMX decoder’s address
Zone 4 DMX decoder’s address
1
5 6 7 8 9 9 10 11 12
47 8 10 11 12 13 14 15 16
3
WW CW R G B R G B W
T11,T12,T13,T14 Wall Mounted Touch Panel
IMPORTER: Prima Group 2004 LTD, Bulgaria, 1784 Sofia, Mladost 1, bl. 144, Ground Floor; Phone: +359 2 988 45 72;
Table of contents