6
3. Scale Setup. Place the scale on a hard flat surface. Tap the front corner (right or left) of the scale with
your foot. The digit will display. Then the display will show “0.0”. This indicates that the
scale has been setup correctly.
a. Note. This “Scale Setup” procedure applies only after installing a battery. After completing
“Scale Setup”, it is need to be performed again before each weigh.
b. Note. If you step on the platform before “0.0” appears, you will not obtain a reading. If this
happens, step off the scale, then wait for display to turn off, follow above steps to setup scale.
SCALE OPERATION
To measure weight, simply stand with both feet in the center of the scale’s platform. Be sure to stand
erect and remain still. It will show your weight and then display it steady.
Note: If a weight less than 10kg is placed on the scale, the scale will not activate. To weigh
something less than 10kg, activate the scale first by tapping the front corner (right or left)
of the scale with your foot.
When no weight is on the scale for 10 seconds, the scale will turn off automatically.
GETTING ACCURATE READINGS
1. If the scale has not been used for a long time, proceed as follows
a. First, step lightly on the front corner (right or left) of the scale first to activate the scale.
b. Second, wait for the scale to turn off. Then follow above steps to setup scale.
2. If the scale is moved, proceed as follows:
a. Remove the battery from the scale for 5 seconds
b. Replace the battery
c. Follow “Scale Setup” instruction
3. Place scale on flat hard surface. Do not use scale on carpet because the reading will be inaccurate.
4. If the reading appears inaccurate, please check if the battery and the contact point are well connected.
If scale has been in use for a long time, replace the battery and try again.
USAGE NOTES
1. When the display shows “Err”, it means that the scale is overloaded.
2. When the display shows “Lo”, it means that the battery is low. Please replace the battery as soon as
possible.
3. If scale display shows random digits or scale does not automatically shut off, proceed as follows:
a. Remove the battery for 10 seconds
b. Replace battery(see “Preparations Before Use)
c. Follow “Scale Setup” instruction
Subject to change without notice
Extra information on ORION company web-site www.orion.ua