List Item Page
1 Program Block Diagram 3
2PC Recommended Configurations 4
3 Install 5
4 Program icons and Execution 8
5 Program Layout 9
6 Register License Key 10
7 Program Check List 12
8
Program Functions
- Real-Time Monitoring 15
- Detect Settings 19
- System Settings 21
- Log Data Verification 24
- E-Mail alert 25
-SMS alert 27
- Register Member 28
- Register Multi Member 30
[ USER MANUAL ]
2

R01
1. Program Block Diagram
3
8FIDKR (Max 6ea) Remote Access
EVENT
* Temperature
* Mask
E-Mail
* Real-Time Alert
[ USER MANUAL ]
SMS

R01
2. PC –Recommended Configurations
4
•Processor (CPU)
•Operating System
•Memory
•Storage
•Monitor/Display
•Other
Intel Core i5
Microsoft Windows 7, 10
8GB
2GB storage area
Full-HD, 1920 x 1080 or better
Webcam (option)
[ USER MANUAL ]

R01
3. Install
5
•Double click Setup.exe file
•Click Next button
[ USER MANUAL ]

R01
3. Install
6
•Click Install button
•Click Next button
[ USER MANUAL ]

R01
3. Install
7
•Click Finish button
•Created ORION_8FIDKR_Control Icon
[ USER MANUAL ]

R01
4. Program icons and Execution
8
•Double Click ORION_8FIDKR_Control Icon
•Initial layout screen after program execution
- When running the program, it runs in administrator mode
Click the accept button when displaying the content accept button at new screen
[ USER MANUAL ]

R01
5. Program Layout
9
①
③
②
④
⑤
①ORION Logo
②Menu
③controller
④Setting part
⑤Information display
Click the mouse to connect to the orionimages.com homepage
Go to the settings tab for that feature
Enter the currently IP and password controlled 8FIDKR
The actual value of the setting of each function
Recorded information output window
[ USER MANUAL ]

R01
6. License Key Registration
10
To use this program, you need to register a license key.
①Go to the License tab
②Click the Retrieve Mac Address button
③Copy the MAC address and send the MAC address to the charged person at www.orionimages.com
④ORION will send the license key to the requested customer
-Customers requested here are limited to customers who have purchased our products
[ USER MANUAL ]

R01
6. License Key Registration
11
⑤Enter the received license key as shown in the picture above and click the Register button
⑥If the license key matches after clicking the button,
As shown in the picture above, it is activated in green and the functions of other buttons are activated.
-If you do not register a license key, other buttons remain inactive.
•Precautions
1) When installing on a computer other than the one where the license key is registered, you must
perform ①~ ⑥again.
2) Computers that have entered the license key can be erased and reinstalled
However, the MAC address must not be changed. (When switching between Wi-Fi or RJ45)
[ USER MANUAL ]

R01
7. Program Check List
12
①Program execution
②Check the IP address of the control unit (Final version of OPASS app is 2.5.0.11.54.5)
In the photo above, the device's IP address is 192.168.1.5.
[ USER MANUAL ]

R01
7. Program Check List
13
③Enter the IP address and password of the device you want to control and click the Save button.
If the program is closed and restarted without saving, it needs to be set again.
④Save as *.ini file in the desired folder
[ USER MANUAL ]

R01
7. Program Check List
14
•The green and red colors in the picture above are for checking whether the setting values are reflected
in the device. (Feedback)
- Green: :
- Red :
•Environment displayed in red
1) If the device IP address is incorrect
2) If the setting value is not correct
3) When the device is powered off
Indicates that the device responded correctly
Displayed when the device does not reflect the set value
[ USER MANUAL ]

R01
8. Program function - Real-Time Monitoring
15
- Computer IP:
- Device IP:
- Device name:
- ADD:
- DELETE:
- PING:
- SAVE
Get the IP address of the computer where the program is installed.
Set the IP address of the 8FIDKR device.
It refers to the alias of the device and is used to identify the device when an event
occurs in the future.
Add monitoring device (MAX 6 devices)
Delete monitoring device
Network status check between host and device
Save people counting value (It loads automatically after restart the program)
[ USER MANUAL ]
※ This program can monitor max 6 device and computer spec needs to be better than normal spec.

R01
8. Program function - Real-Time Monitoring
16
[ USER MANUAL ]
* Computer IP is loaded after the program run.
If the computer has some network adaptor card, You must select correct ip address.
•Write device ip address in the DEVICE IP textbox
•Write DEVICE NAME Such as Front door
•Click ADD button
•You can see PING value and registered Front door device in the program

R01
8. Program function - Real-Time Monitoring
17
[ USER MANUAL ]
•If you want to use real time monitoring function, Please follow the step below.
1) Register the device in program
2) Stranger Record : ON
3) Click START MONITORING button

R01
8. Program function - Real-Time Monitoring
18
[ USER MANUAL ]
* Click the “START MONITORING” button The text changes to “STOP MONITORING”
* When testing with the device, information is displayed in real time and data is recorded at log data
※ Records are displayed in the log data in real time, but when you click the “START MONITORING” button on
the Log Data tab after monitoring is finished, It is not loaded from two devices, but only from the device of
the current control device IP as left image of actual device

R01
8. Program function - Detect Settings
19
-Temperature
measurement mode:
-Temperature
measurement alarm:
-Temperature
display mode:
-Alarm temperature
value:
-Unregistered mode:
-Records of
non-registrants:
-Mask inspection:
- Load :
- update :
Default setting is On, and when changed to Off, the device does not measure Temp.
(only the facial recognition function operates). Device reboots when setting is changed.
Default setting is On. When changed to Off, the alarm does not sound even if the
measured temperature is high.
Temperature displayed on the screen can be changed to Celsius or Fahrenheit
If visitor has more value of setting Temperature, it mean high temperature
Mode for allowing general visitors not registered at the device
Decide whether to store visitor information on the device
Set the inspection of whether or not to wear a mask.
When the log data is loaded after setting it to Off, it is marked as “-”
Function to load the value set in the device
(recalls the set information and reflects it in the information)
Function to apply the value set in S/W to the device
[ USER MANUAL ]

R01
8. Program function - Detect Settings
20
-Company's name :
-Live recognition:
-Wiegand Mode:
-Relay output:
-Relay mode: :
Company name is a function to change the company name displayed on the device
This is a function to set biometric recognition on/off, and photos are also recognized
when off.
It is linked to the RFID function and requires inquiries for detailed explanations.
Generally, the relay operates when it is set to the entry mode, and the output mode is
abnormal.
If the mask is not worn while the temperature or the presence of the mask is on, the
relay operates.
Mode1 operate N.O (Normally Open) Working as Close
Mode2 operate N.C (Normally Close) Working as Open
[ USER MANUAL ]
Other manuals for 8FIDKR
1
Table of contents
Popular Wireless Access Point manuals by other brands

ANTAIRA
ANTAIRA APX-110N5 user manual

Fortinet
Fortinet AP400 Series installation guide

ADTRAN
ADTRAN BLUESOCKET 1940 quick start guide

D-Link
D-Link AirPlus Xtreme G DWL-2000AP instruction manual

Moxa Technologies
Moxa Technologies TAP-213 Quick installation guide

Ruijie
Ruijie RG-AP850-I-V2 Series Hardware installation and reference guide

3Com
3Com OfficeConnect 3CRWE454G75 Quick start guides

Moxa Technologies
Moxa Technologies AWK-4121 Quick installation guide

Ubiquiti
Ubiquiti BulletM2-HP quick start guide

Moxa Technologies
Moxa Technologies AirWorks AWK-1100 user manual

Siemens
Siemens SIMATIC NET SCALANCE W720 operating instructions

Edimax
Edimax EW-7203APg Specifications