Orvaldi Vsinus 800 User manual

4 hours
CAUTION: NEVER connect a laser printer or scanner to the
UPS unit. This may cause the damage of the unit.
1. Introduction
By combining plug-and-play installation with digitalized PWM-based controller, the UPS
becomes a perfect choice for affordable, easy-to-use power protection for critical computers or
small servers in office and home. It will protect data loss from power failure and surge.
2. Product Overview
Front View:
Back View:
IEC Type I IEC Type II NEMA TYPE I NEMA Type II
Schuko Type India Type
3. Installation and Initial Startup
NOTE: Before installation, please inspect the unit. Be sure that nothing inside
the package is damaged.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow.
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT
operate the UPS where the temperature and humidity is outside the specific limits. (Please
check the specs for the limitations.)
Connect to Utility and Charging
Plug in the AC input cord to the wall outlet. For the best results,
suggest to charge the battery at least 4 hours before initial use.
The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the
power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
Connect Modem/Phone for Surge Protection (Only for the model with
RJ-11/RJ-45)
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of
the UPS unit. Connect from “OUT” outlet to the computer with phone line cable.
Connect Communication Cable (Only for the model with USB/RS-232 port)
To allow for unattended UPS shutdown/start-up and status monitoring, connect the
communication cable one end to the USB/RS-232 port and the other to the communication
port of your PC. With the monitoring software installed, you can schedule UPS
shutdown/start-up and monitor UPS status through PC.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again
the power switch.
ORVALDI Line Interactive Sinewave UPS
Quick Guide V. 1.0
LCD panel
Power switch
Output receptacles
AC input
Circuit breaker
Options --
RS-232 communication port
USB communication port
RJ-11 or RJ-45 surge protection
RJ
-
11
RJ
-
45
LCD Panel:
Input voltage Load level indicator, flashing
Output voltage indicates overload
AC mode indicator Battery capacity indicator, flashing
Battery mode indicator Indicates low battery

4. Important Safety Warning (SAVE THESE INSTRUCTIONS)
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (See the specifications for the
acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and
avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances
such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages
or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power
cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must during
UPS installation in order to reduce leakage current below 3.5mA.
Attention hazardous through electric shock. Also with disconnection of this unit from the
mains, hazardous voltage still may be accessible through supply from battery. The battery
supply should be therefore disconnected in the plus and minus pole at the quick connectors of
the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep unauthorized personnel away
from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or
mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
5. Software Download & Installation (Only for the model with
communication port)
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.power-software-download.com
2. Click ViewPower software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
6. Trouble Shooting
Use the table below to solve minor problems.
Problem Possible Cause Solutions
Low battery. Charge the UPS at least 4 hours. Nothing displays on
the front LCD panel
but the mains is
normal.
The UPS is not turned on.
Press the power switch again to turn
on the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overload. Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
The UPS is overload. Remove some critical load.
Battery voltage is too low. Charge the UPS at least 4 hours.
When power fails,
back-up time is
shorten.
Battery defect. It might be
due to high temperature
operation environment, or
improper operation to battery.
Replace the battery with the same
type of battery.
The mains is normal
but the UPS is in
battery mode.
Power cord is loose. Reconnect the power cord properly.
7 Specifications
Model 600 800
CAPACITY 600 VA / 360 W 800 VA /480 W
INPUT
Voltage 110/120 VAC or 220/230/240 VAC
Voltage Range 81-145 VAC / 162-290 VAC
OUTPUT
Voltage Regulation ±10%
Transfer Time Typical 2-6 ms, 10 ms max.
Waveform Pure Sine Wave
BATTERY
Type & Number 12 V/7 AH x 1 12 V/9 AH x 1
Charging Time 4 hours recover to 90% capacity
PHYSICAL
Dimension (DxWxH) mm 328 x 100 x 145
Net Weight (kgs) 5.2 6.0
Environment
Humidity 0-90 % RH @ 0-40° C (non-condensing)
Noise Level Less than 40 dB
MANAGEMENT
USB/RS-232 (Option) Supports Windows® 98/2000/2003/XP/Vista/2008,
Windows® 7, Linux, and MAC

Other manuals for Vsinus 800
1
This manual suits for next models
1
Other Orvaldi UPS manuals