oserio LCT 300 User manual

EInfrared Thermometer Instrucon Manual – LCT 300
Infrared Thermometer
Thank you for selecng oserio series of Health Management Products.
This Instrucon Manual will guide you through the setup procedures and outline the key features.
www.oserio.com
130-BFP219-101
Company: Charder Electronic Co., Ltd.
Address: 103 Guozhong Rd. Dayuan Vil. Dali District. Taichung City. Taiwan
Service Line: +886 4 24079943 Made in China

Health conscious‧Professional‧Innovave

LCT-300
Content
3.1 Funcons
3.2 Storage Method
3.3 Display symbol instrucon
3.4 Specificaons
Before You Use
The Infrared thermometer
Operaon Instrucons
1.1 Know Your Unit
1.2 Knowing Body Temperature
1.4 Important Safety Notes
More Informaon
2.1 Usage Method
1
2
4
6
10
11
12
14
Funcon buon
On / Off memory
Display
Measurement buon
Baery
Probe
Before You Use The Scale
1.1 Know Your Unit
Front Back
5
5
6
6
1

1.2 Knowing Body Temperature
Normal human body temperature is a rang, not a fixed value. It fluctuates throughout the day; generally,
lowest in the morning and highest at sunset. It also tends to decrease with the age -infant has higher
temperature than adult .
As well , different sites (oral , axilla , rectum and ear) have different temperature -generally speaking, ear
temperature is close to oral but higher about 0.5 °C than axillary temperature.
Human body temperature is controlled and adjusted by the hypothalamus in the brain and the blood
flowing through hypothalamus also flows through ear drum. Then measuring ear temperature can best
reflect the body temperature than other sites. Our Infrared Thermometer uses infrared technology to
measure infrared energy emied from the ear drum and surrounding ssue ; then coverts into the
temperature value-safely, conveniently and precisely measure the ear temperature for you.
23
Before You Use The Infrared thermometer
Using our Infrared thermometer to take ear temperature, the normalhuman body temperature range is
35.5~38.0 °C (96.4~100.4°F )
Table of normal human body temperature range by age:
Age
0-2 years
3-10 years
11-65 years
>65 years
Range( °C )
36.4-38.0°C
36.1-37.8°C
35.9-37.6°C
35.8-37.5°C
Range( °F )
97.5-100.4°F
97.0-100.4°F
96.6-99.7°F
96.4-99.5°F
However, the normal range is also different from person to person. To determine your and your family
members’ normal temperature range is very important. It can be done easily by using our Infrared Ear
Thermometer. Please pracce to take temperatures on yourself and your healthy family members to
determine their normal temperature ranges.

Before You Use The Infrared thermometer
Cauon:
1.3 Important Safety Notes
Please read through the instrucon manual before using the thermometer; as
proper technique is crical for taking accurate temperatures. The performance of
the thermometer may be adversely affected withimproper usage.
Do not use the thermometer outside the operang ambient temperature
of 10 ° C (50 ° F)~40 ° C(104 ° F).
Do not use the thermometer outside the operang ambient humidity up to 95%RH.
Do not use the thermometer when the ear canal is wet, or when the person
is suffering from ear diseases.
Earwax and obstrucons will affect the accuracy of the thermometer.
Sideway sleeping gesture will cause the ear temperature to rise, please avoid it.
The thermometer is calibrated and does not require re-calibraon if used
according to the instrucons.
1.
2.
3.
4.
5.
6.
7.
The measured temperatures may be different in the different ear side. Please
measure the same ear to help ensure the accurate measurement.
Aer shower or exercise, the body temperature will rise.
Do not insert the probe into the ear canal with excessive force.
When the baery symbol" "appears, it means low baery, please replace the
new baery.
This thermometer is intended for household use only. The use of this thermometer
is not intended as a substute for physician' s consultaon.
8.
9.
10.
12.
45

6
1.2 Usage Method
Please make sure the cleanness of the opcal glass inside the probe. You can use a coon swap to clean
the opcal glass; if moistened with alcohol, waing and restarng aer 5 minutes, otherwise the result of
measurement will be too low.
Measuring method (ear):
Perform an ear tug to straighten the ear canal. This gives the thermometer a clear view of the eardrum.
AB
If the ear temperature is over 38.0 °C ,it is fever.
FEVER: over 38.0°C
1.
2.
34.6°C 36.8°C
Operaon Instrucons
While tugging the ear, fit the probe snugly into the ear canal as far as possible and press the measurement
buon. Release it, when you hear the Beep.
Children under 1 year:
Pull the ear straight back.
Children aged 1 year to adult
Pull the ear up and back.
7
C D

Operaon Instrucons
9
When the LCD displays " " symbol, you can measure again. If you don’t press any buon within one
minute, the thermometer will shut down automacally.
Note: It is recommended that you take three temperatures measurements in the sameear
under the following circumstances. If they are different, use the highest reading.
Infants in the first 3 months of life.
Children under three years old who have a condion such as a compromised immune system and for
whom the presence or absence of fever is crical.
When you are first learning to use the ear thermometer unl you are comfortable with the technique and
are gaining consistent reading.
Replacing The Baery:
When the display appears" "symbol, meaning low baery, please replacethe baery with a new one.
1. Prepare a lithium cell, type CR2032.
2. Remove the baery cover (B-6).
3. Be sure the <+> up and replace the new baery.
4. Put back the baery cover.
4.
●
●
●
5.
Important: As with any type of thermometer, slight temperature
variaons (±0.2-0.3°C/±0.3-0.5°F) can happen, if consecuve
measurements are taken.
8
1.2 Usage Method
Measuring method (forehead):
LCT-300 can measure forehead temperature (aiming at forehead at a distance about 1 cm) without
touching the skin. It is suitable to checking many person quickly and safely. We suggest that using
forehead measurement to check temperature at first. If the person’s forehead temperature is higher
than 37℃, switch to ear measurement to double check his temperature.
Press (A-4) to turn on and the thermometer is default as ear funcon.
To measure forehead temperature, please press (A-3) and " " will appear on the top le corner of LCD
display. Aiming the probe at forehead or temporal about 1cm distance from skin, press (B-5) to get the
forehead temperature. You can switch to measure ear temperature by pressing (A-3) again and " "
disappears; then it return to ear funcon.
Since forehead (temporal) temperature is easily affected by the ambient, if you take forehead
temperature and get a reading higher than 37.0°C (98.6°F) , it is beer to double check if the client has a
fever by switching to ear funcon and measuring ear temperature.
Our forehead measurement is really no touching the skin and only 1 secondmeasuring me.
3.
●
●
●

11
More Informaon
3.2 Storage Method
Do not expose to temperature extremes below(-20°C (-4°F ) or over (50°C(122°F), or excessive humidity(
over95%RH).
Do not expose to direct sunlight or near any fire.
Do not shock, vibrate, drop or step on the thermometer.
Do not allow any liquid into the thermometer.
Do not disassemble, repair or remodel the thermometer.
Keep out of reach of children.
Please take out the baery, if you do not use for a long me.
Clean the main body of the thermometer with a so and dry cloth, no containing abrasive agents.
Please only use lithium baery type CR2032.
Please do not discard the baery into fire.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
10
Silent Fever Alarm:
When the measured temperature is higher than 38°C(100.4 °F) , the LCD backlight will change color.
Auto Memory:
1. Turn the thermometer on.
2. Press the memory buon.
3. Read the temperature in last me from the display.
4. According to the same method as above, press the memory buon twice, the display will show the
temperature of last two mes, and so on.
Changing Temperature Scale:
1. Turn the thermometer on.
2. Press the memory buon( A-3) and keep it, then press measurement buon ( B-5); the temperature
scale between Celsius (°C) or Fahrenheit (°F) is switched.
4. According to the same method as above, press the memory buon twice, the display will show the
temperature of last two mes, and so on.
●
●
●
More Informaon
3.1 Funcons

13
More Informaon
LCD display Display meaning
Error funcon display
Measuring when it is not ready; please
wait for ready status.
This thermometer is ready to measure Ear
temperature.
This thermometer is ready to measure
Forehead temperature.
The thermometer is working.
Measurement complete, the unit is ready
again for next measurement.
The baery should be replaced.
Ready to measure (Ear)
Ready to measure
(Forehead)
Work
Measurement
complete
Low baery
indicaon
Descripon
12
3.3 Display symbol instrucon
LCD display Display meaning
Turn on the unit All segments displayed.
Please check if the baery has been loaded
correctly.
Display ”HI” when measured target’s
temperature higher than 50°C.
Display ”LO“ when measured target’s
temperature lower than 0°C.
When the ambient temperature higher
than 40°C, please return to normal area.
When the ambient temperature lower than
10°C, please return to normal area.
Blank display
Measured
temperature too high
Measured
temperature too low
Ambient
temperature too high
Ambient
temperature too low
Descripon

14
More Informaon
3.4 Specificaons
LCT-300
Model
Memory Auto-memorized the last ten measured temperature.
Measuring Time one second
Baery Type CR2032 lithium cell (x1)
Baery Life At least 2 years or 3000 measurements
Automac Switch-Off 1 minute aer last measurement has been taken.
Weight 32 / 55g (with baery)
Standard Complies with CE EN12470-5 and ASTM E1965-98 requirements.
CE Medical Device Class II a
Displayed Temperature Range 0℃~50℃ (32℉~122℉)
Operang Ambient Temperature / Humidity Range 10℃ ~40℃ (50℉ ~104℉ ) / 0~95%RH
Accuracy ±0.2℃
-20℃~50℃ (-4℉~122℉) / 0~95%RH
o
Storage Temperature / Humidity Range
0.1℃or ℉
Resoluon
Sensor Type Thermopile
Table of contents