Function
The flush-mounted -control panel enables the remote control of important functions of the following
-controls
- Filter-, backwash control EUROMATIK.net, PC-40.net, PC-45 exclusiv.
- Dosing control WATERFRIEND MRD-1, MRD-2 or MRD-3.
- RGB Lighting controller Color-Control.NET with 3 Attractions
- Attraction control for 6 attractions and «Attraktion-control.plus».
- Pool-cover controller Cover-control.plus
- Steamgenerator Silver-Steam, as of 2015
Technical data
Dimensions:
195mm x 175mm x 30mm
Operating voltage:
12V Safety extra-low voltage
max. cable length:
50m
Protection class:
IP 65

Operating manual external touch control panel (Smart) Page: 2 of 14
Table of contents
Function...............................................................................................................................................................1
Technical data.....................................................................................................................................................1
Table of contents................................................................................................................................................2
Installation site....................................................................................................................................................3
Mounting..............................................................................................................................................................3
Installation of the control panel in the tile frame ............................................................................................3
Electrical Connection.........................................................................................................................................4
Low-voltage cables........................................................................................................................................4
Wiring diagrams..................................................................................................................................................4
Connection of devices via the digital data bus „osf bus“ ..........................................................................4
Connection with EUROMATIK.net ................................................................................................................4
Connection without EUROMATIK.net ...........................................................................................................5
LAN...................................................................................................................................................................6
Connecting devices via LAN .........................................................................................................................6
Operation.............................................................................................................................................................6
Overview........................................................................................................................................................7
Device list ........................................................................................................................................................7
Display settings...............................................................................................................................................7
About touch display.......................................................................................................................................7
Time & date ...................................................................................................................................................7
Language.......................................................................................................................................................7
Screen lock settings ......................................................................................................................................7
Infoscreen settings .........................................................................................................................................8
Add OSF device (LAN connection) ...............................................................................................................8
Service functions ............................................................................................................................................9
Touch screen calibration ...............................................................................................................................9
Factory settings.............................................................................................................................................9
Network settings............................................................................................................................................9
Menus of the connected devices ......................................................................................................................9
Euromatik.net ..................................................................................................................................................9
Swimming pool cover ....................................................................................................................................9
Manual operation........................................................................................................................................ 10
Attraction controller Attraktionssteuerung.NET....................................................................................... 10
Dosing station WATERFRIEND .................................................................................................................. 11
Color light controller Color-control.NET ................................................................................................... 11
Edit color program...................................................................................................................................... 11
Configuration of attractions........................................................................................................................ 12
Configuration of the DMX output ............................................................................................................... 12
Steam generator Silver-Steam.................................................................................................................... 12
Swimming pool controller PC-45 exclusiv ................................................................................................ 12
Attraction controller Attraktion-control.plus ............................................................................................ 13
Cover-control.plus controller for the swimming pool cover................................................................... 13

Operating manual external touch control panel (Smart) Page: 3 of 14
Installation site
The external control panel includes, among other things, buttons for operating the swimming pool
cover. For this reason, the external control panel may only be installed in a location that allows an
unrestricted view of the entire swimming pool. The external control panel must not be installed in
positions from which the swimming pool cannot be fully viewed! It is not suitable for installation
outside of buildings.
Mounting
The control panel is designed for flush mounting using the tile frame supplied. Before
opening the housing, the device must be de-energized.
The tile frame is installed by the tiler while the tiles are being laid.
1.)
Prepare the tile frame:
Bend all four fastening tabs backwards and then outwards.
Tile frame
Bend the fastening
tabs backwards
Bend the fastening tabs outwards
2.)
Make a recess at the intended mounting location in the wall, which will later
accommodate the tile frame and the housing.
3.)
Align the tile frame in front of the wall recess as follows:
horizontally
perpendicular
the front edge of the tile frame must be flush with the tiles!
4.)
Fix the fastening tabs to the wall with screws or nails and fix them with mortar or tile
adhesive.
5.)
Lay tiles right up to the outer edge of the tile frame.
Installation of the control panel in the tile frame
The installation of the control panel in the tile frame is done by an electrician after the wall
has been covered with tiles and grouted.
1.)
Lead connecting cable through the cable gland, and then tighten the pressure screw
of the screw. The cable entry must be watertight.
2.)
Insert the metal housing into the tile frame and fasten it with the enclosed 4mm
stainless steel screws. A screw is screwed into each of the 4 corners.
3.)
Connect the cable to the control panel in accordance with the installation and
operating instructions. The clamps are on the back of the board.

Operating manual external touch control panel (Smart) Page: 4 of 14
4.)
Insert the control panel into the housing and screw it to the metal frame with the
enclosed screws. All screws must be screwed in to prevent water from entering.
The seal must not be damaged.
5.)
Carefully place the cover frame with the magnetic holder. The magnets must
engage in the recesses of the board.
Electrical Connection
The electrical connection as well as the work of adjustment and servicing should be carried
out only by an approved electrician! The connection diagrams enclosed and the relevant
safety provisions applicable must be observed and followed.
Low-voltage cables
Low-voltage cables should not be laid along with three-phase or AC cables in the same cable duct.
In general, laying low-voltage cables near three-phase or AC cables must be avoided.
Wiring diagrams
The power supply for the touch control panel can either be via EUROMATIK.net or via an external
power supply unit. Data communication is carried out via osf bus. Several devices can be connected
to the osf bus. Note the polarity of the bus line!
Connection of devices via the digital data bus „osf bus“
Devices connected via the osf bus communicate automatically with the control panel. Below is a list of the
devices that are connected via the osf bus data bus: Euromatik.net, PC-40.net, Attraction-Control.net, Color-
Control.net, all Waterfriend MRD dosing stations and the Silver- Steam.net steam generator.
Connection with EUROMATIK.net
A 4-core cable 4x0.5mm² (e.g. J-Y (St) Y 2x2x0.8, Art. No. 102.000.1012) with a maximum length of 50m is
used to connect to Euromatik.net.

Operating manual external touch control panel (Smart) Page: 5 of 14
Connection without EUROMATIK.net
If no EUROMATIK.net is available, the power supply for the touch control panel can be provided via an
additional external power supply unit (Art. No. 330.001.2000).
external touch
control panel
12V GND D+ D-
2
3
4
1
Color-
control.net
D-
D+
D-
D+
twisted wire
osf-Bus
12V. supply
Euromatik.net
12VGND D+ D-
58
61
62
57
Waterfriend
MRD-3/2/1
Data+ Data-
D+
D-
Note the polarity of the bus line!
more
external touch
operating panel
12V GND D+ D-
2
3
4
1
twisted pair osf-Bus
12V. supply
external power supply
GND
D+
D-
12V
L
N
D+
D-
mains
230V 50Hz
Waterfriend MRD
Color-Control.net
Attraction-Control.net
Silver-Steam.net
Data+ Data-
D+
D-
twisted wire
osf-Bus
Silver-Steam
steam generator
Data+ Data-
44
45
Attraction-
Control.net
D-
D+
D-
D+

Operating manual external touch control panel (Smart) Page: 6 of 14
LAN
The external smart touch control panel has a LAN connection (Ethernet, RJ45). Communication with OSF
devices such as PC-45 exclusive, Cover-Control-Plus and Attraction-Control-Plus takes place exclusively via
the LAN network. To communicate with these devices, all controllers must be connected to the same local
network. The easiest way is to connect all network devices to a network switch. The -range includes the
suitable -cluster switch plus. A standard network cable (patch cable, CAT5) must be used for connections.
Connecting devices via LAN
Devices connected via a local network must first be added to the list of available devices. To establish a
connection, select the "Add device" submenu in the main menu and select the desired block from the list.
Then follow the instructions to connect.
Operation
Overview Device list
Overview Device- Screen- Settings
list lock
Patchkabel
12V

Operating manual external touch control panel (Smart) Page: 7 of 14
Overview
The overview display depends on the devices connected to the touch control panel.
Attraction-Control Color-Control.net
Euromatik.net Waterfriend MRD-3 Silver Steam
In the event of faults or alarms in devices, an alarm symbol in the form of a semicircle is displayed
on the main page to the left of the device measured values.
Red light indicates an alarm, yellow a warning (e.g. an empty canister at a dosing station).
Alarm Warning
Device list
All connected devices are displayed on this screen. (See the picture on the previous page).
The button on this page searches for and queries all connected devices via the osf bus. The survey is
carried out automatically every few minutes.
Each available (linked) device has its own menu structure.
The button leads to the main menu of the display settings.
Display settings
In this menu, settings are made that relate to the external control panel itself and
not to the devices connected to it.
About touch display
This menu item leads to a screen showing the version and date of the external
smart touch control panel program.
Time & date
In this menu you can set and synchronize the clocks of all connected devices. To
synchronize all clocks, you have to press the corresponding button.
Note: If automatic time setting via the Internet is selected, all connected
devices must be connected to the Internet.
Language
In the Language menu you can change the language for the external touch control panel.
Screen lock settings
This submenu contains two settings:
1. Screen lock (on or off). When the lock is activated, a key icon is displayed on the bottom line of the
main screen. Pressing this button will lock all buttons on the screen. To unlock, press the key icon
again and hold it down for 5 seconds.

Operating manual external touch control panel (Smart) Page: 8 of 14
2. Screen lock timer. This parameter determines after how many minutes of inactivity the control panel
screen will automatically lock. To unlock, press and hold the key icon for 5 seconds.
Infoscreen settings
In this submenu you can adjust the appearance of the info screen. The info screen shows the various pool
parameters measured by the connected devices. If two pool controllers are connected, the info screen shows
the water temperature of the device, which is higher in the list of connected devices.
1. The Info Screen Settings screen displays the appearance of all Info screens. There are 3 different
screens possible, which alternate at individually defined intervals. Each screen can display up to 3
pool parameters.
2. Timer for the start of the information screen. This parameter defines after how many minutes of
inactivity the control panel screen automatically switches to the display mode of the info screen. If the
time has not been set, the info screen can be switched on with the button on the main screen.
Add OSF device (LAN connection)
In this menu, the selected device can be connected to the control panel via LAN. To connect two devices,
make sure that both devices are online. After selecting the desired device from the menu, the communication
instructions will appear on the screen. Connection takes place in three steps:
1. Press the Start button on the control panel. At the same time, commands are sent to the network to search
for the desired device.
2. Press the answer button on the second device to confirm the connection. Note: For different devices, the
answer button may be on the device screen or it may be a physical LAN button.
3. When the connection is successful, the control panel will display the type and serial number of the
connected device. To save the connection, press the OK button.

Operating manual external touch control panel (Smart) Page: 9 of 14
Service functions
The second display settings screen contains utility functions. The menu is initially
locked to prevent accidental changes. Press the key symbol for 3 seconds to
unlock.
Touch screen calibration
In this menu you can calibrate the touchscreen. Calibration of the display is
required if the device does not correctly recognize finger touches.
To perform the calibration, follow the on-screen instructions, three times touch the
squares in different places on the screen, and save the calibration results by
pressing the "OK" button.
Factory settings
By pressing the "YES" key, all user parameters are reset to the factory settings. All
operational logs remain unchanged.
Network settings
The factory LAN settings of the smart touch device enable plug-and-play remote
control. If necessary, you can set the IP address manually and prevent the device
from communicating with the OSF communication server. (For details, see
"Internet Connection" section.) Access to change settings via LAN is restricted by a
PIN code, which can be viewed and changed here.
Menus of the connected devices
Euromatik.net
The menu structure of the Euromatik.net control unit on the external smart touch panel largely repeats the
structure of the display menu on Euromatik.net's own display and shows the most important and required
parameters and settings.
Swimming pool cover
Before operating these switches, the swimming pool must be subjected to a
visual inspection. The swimming pool cover may only be moved if it is certain that

Operating manual external touch control panel (Smart) Page: 10 of 14
there is no person in the swimming pool and that moving the swimming pool cover does not result in a
dangerous situation.
Manual operation
In this menu it is possible to switch on the filter pump manually outside of the
filter cycles and to start the backwashing manually.
Pool settings Info display Utility functions
Attraction controller Attraktionssteuerung.NET
The menu of the Attraktionssteuerung.NET menu on the external smart touch panel shows the most important
parameters and settings.

Operating manual external touch control panel (Smart) Page: 11 of 14
Dosing station WATERFRIEND
As an example, the screen of the MRD-3 dosing system is shown below. The screens for the dosing systems
MRD-1 and MRD-2 look similar with the display of the corresponding parameters.
The control parameters of the dosing station are protected against inadvertent adjustment. To remove the
protection you need to click and hold the key icon in the top left corner for 5 seconds.
Color light controller Color-control.NET
The Color-Control.NET is used to set and control colored pool lighting and to control three attractions.
Edit color program
The color programs can be edited in this menu after you have previously selected the program for editing.
Scenes of the program. The current scene for
editing is highlighted with a white square.
Adding / deleting scenes. Max 6.
Scene color picker
Fields for entering RGB (W) color values.
Breaks and transitions between the scenes
Number of repetitions of the program (0 - no limit)
The next program number after the end of the
repetitions.
3 buttons to control the
attractions
Button for switching on
the colored light
Stop / start color program
Current color selection
field
Scene change speed
General brightness
control
Edit the selected
program
Choice of color
program.

Operating manual external touch control panel (Smart) Page: 12 of 14
Configuration of attractions
Here you can determine the presence of the attraction. Attractions that are de-
selected here will not be displayed on the control and settings screens.
Assign a name to the attraction by selecting an image
for it.
Also enter the number of the color program that
should run parallel to the operation of this attraction.
Configuration of the DMX output
Here you can define the number of DMX channels per
zone. This way you can control both RGB and RGBW
with additional white color. The Color-Control.net can
control 10 zones independently of each other. In order
to implement a complex color composition consisting of several DMX projectors
that light up in different colors, different projectors have to be set up for different
zones and accordingly different color schemes for scenes have to be defined for
each zone.
Steam generator Silver-Steam
The menu of the Silver Steam steam generator on the external smart touch panel shows the most important
parameters and settings. For more details on the settings, see the instructions for the steam generator.
Swimming pool controller PC-45 exclusiv
The version number and the IP address of the connected device are displayed in the top line of the screen.
The minus button removes a device from the list of available devices.

Operating manual external touch control panel (Smart) Page: 13 of 14
Via the display size menu, you can select the appearance of the PC-45 exclusively on the main screen of the
control panel.
x1 x2
Attraction controller Attraktion-control.plus
The version number and the IP address of the connected device are displayed in the top line of the screen.
The minus button removes a device from the list of available devices.
Here you can set time limits and timers for the 3 attractions. It is possible to program 15 independent
switching cycles per attraction.
Cover-control.plus controller for the swimming pool cover
The version number and the IP address of the connected device are displayed in the top line of the screen.
The minus button removes a device from the list of available devices.
Please also observe the installation and operating instructions for the connected -devices.