Osram 2720 User manual

2720
IP65 LED Strobe wash bar light
User manual
P
le
a
se
rea
d
t
he
ins
t
r
u
ction
s ca
refu
ll
y before use

2
TABLE OF CONTENTS
1.
S
af
ety
I
nst
r
uctions ......................................................................................1 -
3
2. Technical Specifications
...........................................................................................5
3. How To Control The Unit
..........................................................................................6
4. DMX Channel List.........................................................................................16
5. Shape.........................................................................................................................18
6
. Trouble shooting
......................................................................................................19
7
. Fixture Cleaning
.......................................................................................................20
statement
The product has well capability and intact packing when leave
factory. All of the user should comply with warning item and manual, any
misuse cause of the damages are not included in our guarantee, and
also can not be responsible for any malfunction & problem owing to
ignore the manual.

3
1.
S
af
ety
I
nst
r
uctions
Please keep this User Guide for future consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using
the unit.
Before operating, ensure that the voltage and frequency of power
supply match the power requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order
to avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at
least 50cm from adjacent surfaces. Be sure that no ventilation slots are
blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as
it is fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head
only, but always by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the
temperature is higher than this Unit surface temperature may reach up to 85℃.
DO NOT touch the housing bare-hand during its operation. Turn off the power
and allow about 15 minutes for the unit to cool down before replacing or serving.
the event of serious operating problem, stop using the unit immediately.Never
try to repair the unit by yourself. Repairs carried out by unskilled people can
lead to damage or malfunction. Please contact the nearest authorized
technical assistance center. Always use the same type spare parts.

4
DO NOT touch any wire during operation as high voltage might be causing
electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to
rain or moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced
if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing
or attempt any repairs yourself. In the unlikely event your unit may require
service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that
the unit is firmly fixed to avoid vibration and slipping while operating.
And make sure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Also always use a
safety cable that can hold 12 times of the weight of the unit when installing the
fixture.
The equipment must be fixed by professionals. And it must be fixed at a place
where is out of the touch of people.

5
2. Technical Specifications
Light Sources: 960*0.2W 4IN1 RGBW LED
Beam Angle:120°
Power Consumption: 210w
Power Voltage: AC 100-260V, 50/60Hz
Control
DMX Channel:16/44 Channels
Control Modes: DMX512/Auto Run/Music
Construction
Display:180° reversible LCD Display
Data In/Out socket: 3-pin XLR sockets
Power Socket: Waterproof Powercon in/out
Protection Rating: IP65
Net Weight:6 kgs
Features
Dimmer:0~100% smooth dimming ;two dimmer model in optional( delay or
without delay)
8-Zone controlled
Strobe effects with high brightness
Led temperature protection & Fan run speed automatic based on the head
temperature.

6
3.Lux Date
4. Display & Menu

7
Display:
MENU To select the programming functions
DOWN To go backward in the selected functions
UP To go forward in the selected functions
ENTER To confirm the selected functions
Set DMX
Address Code
1 Press "Menu" to "Set DMX Address",and press"ENTER" keys to enter
into
2 Show "Set DMX Address DMX Address:001",Press the "UP and DOWN"
keys to amended
3 Press "ENTER"keys to save and Exit,Press the"MENU"Keys does not
save and Exit
Menu
Mic Sense
001 - 100,Sound sensitivity adjustment
Language
English
Chinese
Reset
Yes
No
Default
Yes
No
Adjust
Pass Word:up+down+up+down
Red
0 - 255
Green
0 - 255
Blue
0 - 255
White
0 - 255
Address
Setting from 001 - 512

8
Reverse
Forward or reversed setting
Channel
44 channels
16 channels
Inform
1.CH Value
Each channel show CH
value
2.Temp ____℃
Show the temperature of led
board
3.Soft V1.1
Show the version number
Mode
DMX 512
AUTO
SOUND
5.DMX Channel List
Model 1 - CH44
Channel
Display
Function
Value
CH-1
Dimming
From dark to bright
0 --- 255
CH-2
Dimming Model
Model - 1
0 --- 49
Model - 2
50 --- 99
Model - 3
100--- 149

9
Model - 4
150--- 255
CH-3
Strobe
No
0 --- 15
from slow to fast
16 --- 165
flashes strobe slow to fast
166---215
Random stroboscopic
215---255
CH-4
Red - 1
From dark to bright
0 --- 255
CH-5
Green - 1
CH-6
Blue - 1
CH-7
White - 1
CH-8
Red - 2
From dark to bright
0 --- 255
CH-9
Green - 2
CH-10
Blue - 2
CH-11
White - 2
CH-12
Red - 3

10
CH-13
Green - 3
CH-14
Blue - 3
CH-15
White - 3
CH-16
Red - 4
CH-17
Green - 4
CH-18
Blue - 4
CH-19
White - 4
CH-20
Red - 5
CH-21
Green - 5
CH-22
Blue - 5
CH-23
White - 5
CH-24
Red - 6
CH-25
Green - 6
CH-26
Blue - 6

11
From dark to bright
0 --- 255
CH-27
White - 6
CH-28
Red - 7
CH-29
Green - 7
CH-30
Blue - 7
CH-31
White - 7
CH-32
Red - 8
CH-33
Green - 8
CH-34
Blue - 8
CH-35
White - 8
From dark to bright
0 --- 255
No
0----15
R 100%,G up,B0%
16----35
R down,G 100%,B0%
36----55
R 0%,G 100%,B up
56----75
R 0%,G100%,B up
76----95

12
CH-36
CH-36
Static color
Static color
R up,G0%,B100%
96----115
R 100%,G0%,B down
116----135
R 100%,G up,B up
136----155
R100%,G down,B100%
156----175
R100%,G
100%,B100%,W100%
176----195
2800K
196----200
3200K
201----205
3500K
206----210
4000K
211----215
4500K
216----220
5000K
221----225
5500K
226----230
6000K
231----235
6500K
236----240

13
7000K
241----245
7500K
246----250
8000K
251----255
CH-37
CH-37
Effects
Effects
No
0 ---- 9
5 numbers 1 effect
10 --- 49
Dynamic effect 1 fast to
slow
59 --- 89
Dynamic effect 2 fast to
slow
90 --- 129
Dynamic effect 3 fast to
slow
130--- 169
Dynamic effect 4 fast to
slow
170 --- 209
Dynamic effect 5 fast to
slow
210 --- 255
No

14
CH-38
Zone
Static Zone -1
0 --- 4
Static Zone -2
5 --- 9
Static Zone -3
10 --- 14
Static Zone -4
15 --- 19
Static Zone -5
20 --- 24
Static Zone -6
25 --- 29
Static Zone -7
30 --- 34
Static Zone -8
35 --- 39
Static Zone -9
40 --- 44
Static Zone -10
45 --- 49
Static Zone -11
50 --- 54
Static Zone -12
55 --- 59
Static Zone -13
60 --- 64
Static Zone -14
65 --- 69

15
CH-38
Zone
Static Zone -15
70 --- 74
Static Zone -16
75 --- 79
Static Zone -17
80--- 84
Static Zone -18
85 --- 89
Static Zone -19
90 --- 94
Static Zone -20
95 --- 99
Static Zone -21
100 --- 104
Static Zone -22
105--- 109
Static Zone -23
110 --- 114
Static Zone -24
115 --- 119
Static Zone -25
120 --- 124
Static Zone -26
125 --- 129
Static Zone -27
130 --- 134
Static Zone -28
135 --- 139

16
CH-38
Zone
Dynamic Zone -1
140 --- 149
Dynamic Zone -2
150 --- 159
Dynamic Zone -3
160 --- 169
Dynamic Zone -4
170 --- 179
Dynamic Zone -5
180 --- 189
Dynamic Zone -6
190 --- 199
Dynamic Zone -7
200 --- 209
Dynamic Zone -8
210 --- 219
CH-38
Zone
Dynamic Zone -9
220 --- 255
CH-39
Zone change
From dark to bright
0 --- 255
CH-40
Zone change fade
CH-41
Color of Zone Red
CH-42
Color of Zone
Green
CH-43
Color of Zone

17
Blue
CH-44
Color of Zone
White
Model 2 - CH16
Channel
Display
Function
Value
CH-1
Dimming
From dark to bright
0 --- 255
CH-2
Dimming Model
Model - 1
0 --- 49
Model - 2
50 --- 99
Model - 3
100--- 149

18
Model - 4
150--- 255
CH-3
Strobe
No
0 --- 15
from slow to fast
16 --- 165
flashes strobe slow to fast
166---215
Random stroboscopic
215---255
CH-4
Red
From dark to bright
0 --- 255
CH-5
Green
CH-6
Blue
CH-7
White
No
0----15
R 100%,G up,B0%
16----35
R down,G 100%,B0%
36----55
R 0%,G 100%,B up
56----75
R 0%,G100%,B up
76----95

19
CH-8
CH-8
Static color
Static color
R up,G0%,B100%
96----115
R 100%,G0%,B down
116----135
R 100%,G up,B up
136----155
R100%,G down,B100%
156----175
R100%,G
100%,B100%,W100%
176----195
2800K
196----200
3200K
201----205
3500K
206----210
4000K
211----215
4500K
216----220
5000K
221----225
5500K
226----230
6000K
231----235
6500K
236----240

20
7000K
241----245
7500K
246----250
8000K
251----255
CH-9
CH-9
Effects
Effects
No
0 ---- 9
5 numbers 1 effect
10 --- 49
Dynamic effect 1 fast to
slow
59 --- 89
Dynamic effect 2 fast to
slow
90 --- 129
Dynamic effect 3 fast to
slow
130--- 169
Dynamic effect 4 fast to
slow
170 --- 209
Dynamic effect 5 fast to
slow
210 --- 255
No
Table of contents
Other Osram Floodlight manuals

Osram
Osram NOXLITE LED HP FLOODLIGHT II User manual

Osram
Osram Ledvance FLOODLIGHT LED 10W/6500K 10X1 LEDV User manual

Osram
Osram kreios fresnel User manual

Osram
Osram Pursos User manual

Osram
Osram NOXLITE LED HP FLOODLIGHT II 23 W User manual

Osram
Osram Traxon e:cue Allegro Washer AC Static White Installation instructions manual

Osram
Osram Clay Paky Alpha Spot HPE 1500 User manual

Osram
Osram traxon Allegro Washer AC Installation instructions manual

Osram
Osram M28 A User manual

Osram
Osram KREIOS FL User manual