Rev. 03/02/2017
1. Create a specic project folder on PC to store the les
of the application program.
2. Run CoDeSys and open the program (preset for the
WP240) provided as an example:
File > New from template
...\IEC-line\WP240\Examples\WP240_Template.pro
3. Check in the menu
Online > Communication Parameters
that the network address matches the one assigned to
the device. To change this, edit the Value eld and press
Enter key inside the box.
4. Save the starting program in the project folder assigning
it a new name:
File > Save as
MyProgram.pro
5. Attivate the Login using the Online menu or the
appropriate button on the toolbar. The program is rst
compiled and then downloaded to the PLC.
6. Activate the Run of program with the Online menu or
with the toolbar button.
Ref. Getting-Started-CoDeSys-Program_EN.pdf
3 - EXAMPLE PROGRAM
1. Download the Java software from the following Web
page and install it on the PC used for the visualization:
www.java.com/en/download/index.jsp
2. Enter the following address in the Web browser:
192.168.1.101
Username: web_user0
Password: web_password0
3. The initial page, created into application program with
CoDeSys tool, appears in the browser.
NOTE: the administration pages of the PLC are always
reachable in the ADMIN subfolder of Web server by
adding /admin/admin.html to the IP address. To
differentiate the access username/password refer to the
WEB page.
4 - WEB VISUALIZATION
1. If the software includes a new version of CoDeSys
tool, repeat the complete installing procedure, else
update only the IEC-line package. Is not necessary the
uninstalling of previous version.
2. Establish an FTP connection to the PLC (server) device
with the Client available inside CHIPTOOL utility:
Host address: 192.168.1.101
Username: ftp_user0
Password: ftp_password0
NOTE: use the currently set parameters. After update,
the default ones mentioned above will be valid again.
3. Overwrite the A: disk of PLC with the entire content of
folder:
...\IEC-line\WP240\Disk_A_recovery\Disk_A_Image
It’s allowable also the deleting of the disk before this
transfer. However the PLC_PRG folder can not be
removed as it blocked by the Run Time System until the
next reboot.
4. Reboot PLC via the power supply or the RESET button.
To update the software on PLC side it is possible the
using, as alternative to the FTP connection, of a SD
card or USB key memory. For this procedure refer to
the informations inside folder:
...\IEC-line\WP240\Disk_A_recovery
NOTE: after updating the TSP, opening an existing
project, a warning can be displayed in the case that any
used library has been updated. In that case, recompile
the project.
5 - SOFTWARE UPDATE
For more details see the specic manuals in the “Documentation” folder.
WP240
OVERDIGIT
Quick Start Guide