Ozeri Brezza OZF2 Guide

Brezza
Tabletop Air Circulator
with Adjustable Oscillation
Model No: OZF2
INSTRUCTION MANUAL
AND WARRANTY
Copyright 2011, Ozeri

Important Safety Instructions
Thank you for purchasing the Ozeri Tabletop Air Circulator. This product
has passed extensive quality assurance tests for residential use. Every
care has been taken to ensure that it reaches you in perfect condition.
Warning: When using electric appliances, basic safety precautions
should be followed to reduce the risk of re, electric shock and
personal injury, including (but not limited to) the following:
Read all these instructions before attempting to operate this product
and save these instructions for future reference:
lTHIS FAN HAS A POLARIZED PLUG (ONE BLADE IS WIDER THAN THE
OTHER). TO REDUCE THE RISK OF ELECTRICAL SHOCK, THIS PLUG IS
INTENED TO FIT IN A POLARIZED UTLET ONLY ONE WAY. MATCH THE
WIDE BLADE OF PLUG TO THE WIDE SLOT OF THE OUTLET. FULLY
INSERT. IF THE PLUG DOES NOT FIT FULLY IN THE OUTLET, REVERSE THE
PLUG. IF IT STILL DOES NOT FIT, CONTACT A QUALIFIED ELECTRICIAN.
DO NOT ATTEMPT TO BYPASS THIS SAFETY FEATURE.
lNOTE: THIS FAN IS EQUIPPED WITH A FUSE. ALWAYS UNPLUG
THE FAN BEFORE REPLACING FUSES. IF THIS FAN LOSES POWER
AND YOU SUSPECT THE FUSE IN THE PLUG HAS BLOWN, UNPLUG
THE FAN, THEN SLIDE THE FUSE DOOR FOUND ON THE SIDE
OF THE PLUG TO THE OPEN POSITION. SLIDE THE FUSE DOOR
OUTWARD UNTIL THE BLOWN FUSE IS FULLY VISIBLE. REMOVE
THE BLOWN FUSE AND SNAP THE REPLACEMENT FUSE INTO
PLACE. FULLY CLOSE THE FUSE DOOR. ONLY REPLACE WITH A
FUSE RATED AT 2.5 – 5 AMPS, 125 VOLTS.
lUse this fan only as described in this manual.
l Check the voltage indicated on the rating plate. This fan is designed
for a 120V-60Hz electric supply. Make certain the power source
conforms to these electric requirements. Make sure the room where
this fan will be used has a working smoke detector.
2

l Do not use an electrical extension cord with this fan. Do not plug the
fan into a power strip. The use of such devices may create electric and/
or re hazards.
lDo not force your ngers through the front case. Do not allow any
foreign objects through the front case.
lThis product is not a toy. Do not allow children to tamper with the fan.
lBe careful not to allow hair, curtains, tablecloth, clothes or other
nearby objects block the airways of the fan or to enter the openings of
the fan. This can cause damage and/or injuries.
lDo not use this or any fan if the cord is found to be or becomes
damaged. Periodically check the electric cable of this fan. If the electric
cable is damaged, it must be replaced by the manufacturer, its after-
sales service or by a similar qualied person in order to avoid danger.
lDo not use this fan if it falls and/or becomes damaged in any way. If
the fan becomes damaged, it must be replaced by the manufacturer,
its after-sales service or by a similar qualied person in order to avoid
danger.
lDo not use this fan outside, or in any commercial, industrial or
agricultural setting. This fan is only for residential use. Do not use this
fan with any solid state speed control devices.
lDo not use this fan in a damp area such as bathroom.
lDo not use this fan on a window, ledge, or on any unstable platform.
The fan should only be used standing on its base. Never lay the fan on
its side.
lDo not use this fan next to a window or anywhere where exposure to
rain or moisture is possible. This may create an electrical hazard.
lDo not place the electrical cord under any objects, such as carpets,
throw rugs or runners. Do not place electrical cord in areas of foot
trac where there is a risk of stumbling or tripping over it.
lThe fan must always be unplugged when not in use. Before
unplugging the fan, rst ensure it has been turned o.
lDo not operate the fan in an area where gasoline, paint supplies or any
ammable liquids or explosive chemicals are used or stored.
lDo not try to repair or disassemble this fan. Doing so will void the
warranty and may result in damage and/or personal injury. There are
no end-user serviceable parts.
lRemote control devices for other appliances may interfere with this
fan and vice-versa. If this occurs, move the fan to another location.
lThis fan is not suitable for use in agricultural facilities and hazardous
locations. This fan does not meet the requirements of NEC Article 547-
7 and 500 (2002).
lKeep this fan and all electrical appliances out of reach from children at
all times.
3

Overview of your Fan:
1. Carrying Handle
2. Frontal Chrome Cover
3. Blades
4. Side Bracket
5. Control Knob
6. Fan Base
7. Power cord
Fan Specication:
Model #:…………………………………………….………….OZF2
Rated Voltage:………………………………………….. .120V/60Hz
Wattage:………………………………………………………...30W
Net Weight………………………………………………….. 5.1 lbs
Airow at Low Setting (1):…………………………………....10 fps
Airow at Medium Setting (2):……………………………...... 12 fps
Airow at High Setting (3):…………………………………... 15 fps
Operating Instructions:
1. Please ensure the fan if OFF (in the 0 position) and placed on a dry
level surface.
2. Plug the power cord into a polarized
120 volt AC wall outlet.
3. Turn the knob on the front of the
fan upwards for Oscillation Mode, or
downwards for Non-Oscillation Mode.
4. The following are the air speeds for
both Oscillation and Non-Oscillation
Modes:
a. 0 = O
b. 1 = Low
5. To turn the fan O, move the knob back to the 0 position.
Warning: DO NOT ATTEMPT TO FORCE OR IMPEDE THE FAN’S
OSCILLATION. DOING SO WILL DAMAGE THE FAN AND VOID THE
WARRANTY. IF WHEN TURNED OFF, THE FAN IS NOT IN ITS FLUSH
POSITION, SIMPLY TURN THE FAN ON AND WAIT FOR IT TO RETURN
TO ITS FLUSH POSITION, THEN TURN OFF.
1
2
3
4
5
6
7
4
c. 2 = Medium
d. 3 = High

Moderating Temperatures:
The Ozeri Air Circulator can help distribute cooler air from or near your
air conditioner, and warmer air from or near your heater, by creating a
vortex of air ow. Over time this can help moderate temperatures and
increase your cooling or warming eciency, thereby lowering your
energy usage.
IN THE SUMMER:
To circulate cool air, position the fan near an open window exposed to
cooler outside temperatures, or to an air conditioning unit. Since hot air
rises, direct the cool air from the fan upstairs to force the cooler air into
circulations.
IN THE WINTER:
To circulate warm air, place the fan near a heat source and angle the
fan upwards so that the air output from the fan is away from the heat
source. If no heat source is available, simply angle the fan to the ceiling
to force the warmer air into circulation.
5

Adjusting the Vertical Angle:
1. In addition to the Oscillating feature, the Ozeri Air Circulator can also be
adjusted from 0 to 90 degrees vertically.
2. To adjust the vertical angle of airow, rst ensure that the fan is O
(knob should be pointed to the 0 position).
3. Gently hold the base down with one hand, and with the hand tilt the
fan upwards to your desired position.
4. Do avoid injury, do not attempt to adjust the vertical angle while the
fan is On.
Wall Mounting:
1. Find and mark two circles on the wall where the fan will be
mounted. The circles need to be 4 ¾”apart from center to
center. The circle size should be 3/8”in diameter.
2. Drill #8 screws into the wall (screws are not included). Use
drywall anchors if a stud is not available.
3. Leave about 3/8”of each screw exposed.
4. Line up the opening at the base of the fan with the screws
and hang the fan on the wall.
WARNING: DO NOT HANG OR MOUNT THIS FAN ON CEILING. DO
NOT OPERATING THIS FAN IN OSCILLATOIN MODE WHEN IT IS WALL-
MOUNTED.
6

Cleaning:
1. Always disconnect the cord from the electrical outlet before cleaning
your fan.
2. Dust may be removed by using a vacuum cleaner along the back of
the fan where the plastic grille covers the air intake, and along the
front grille cover. A pipe cleaner or exible duster may also be used.
3. Wipe the exterior surfaces of the fan occasionally with a damp cloth
(not dripping wet) and dry thoroughly with a soft dry cloth before
operating the fan.
4. Do not use harsh cleaners or materials to clean this unit, doing so will
cause damage.
WARNING: DO NOT ALLOW WATER TO RUN INTO THE INTERIOR
OF THE FAN AS THIS COULD CREATE A FIRE OR ELECTRIC SHOCK
HAZARD.
Removal of Front Grille for Cleaning:
lEnsure the fan is unplugged, then carefully lay the fan face down on a
at surface.
lTake o the front grille by removing the screws located on the rear of
the fan.
lLift the rear housing (please use handle) to separate from the grille.
lWipe the fan blades and the grille with a damp rag. DO NOT IMMERSE
IN WATER AND NEVER ALLOW WATER TO DRIP INTO THE MOTOR
HOUSING. DO NOT USE CHEMICALS LIKE PAINT THINNER OR GASOLINE
TO CLEAN THE FAN OR BLADES.
lReassemble by realigning the screw holes between the front grille and
the rear housing. Carefully insert and tighten the screws.
lTo store the fan, clean it carefully as instructed. Place the fan in the
original packaging for storage or cover it to protect it from dust. Store
in a cool dry place.
7

WARRANTY INFORMATION
Your Ozeri Air CirculatorTM is warranted to the original owner for 1 year
from the date of purchase against defects in material and workmanship
under normal use and service. Should your Ozeri Air Circulator prove
defective within 1 year from the date of purchase, return the defective
product, freight prepaid along with an explanation of the claim to“Ozeri.”
Please pack your Ozeri Air Circulator carefully to avoid damages in transit.
Under this warranty, Ozeri will repair or replace any parts found to be
defective due to a manufacturer’s defect. This warranty extends only to
personal use and does not extend to any product that has been used
for commercial use, rental use, or use which is not intended. There are
no warranties other than that expressly set forth herein. This warranty is
not transferable. Ozeri is not responsible in any way for damages, losses
or inconveniences caused by equipment failure or by user negligence,
abuse, or use not in accordance with the “User Guide” or any additional
safety, use, or warnings included in the product materials. Further, Ozeri
is not liable for incidental or consequential damages of any nature
resulting from the use of this product and any liability shall not exceed
the purchase price of the product.
This Warranty gives you specic legal rights. You may also have other
rights which vary from state to state.
THIS WARRANTY DOES NOT APPLY TO THE FOLLOWING
- Damage due to accident, misuse, abuse, alterations or vandalism.
- Improper or inadequate maintenance.
- Unauthorized modication or commercial use.
- Damage in return transit
- Unsupervised use by children
Ozeri Customer Service:
Phone: 1-877-299-1296
Email: [email protected]
(OzeriTM and its subsidiaries assume no liability for damage caused by the use of the Ozeri
Ultra Fan other than for its intended use or as instructed above and in the User Manual.)
Table of contents
Other Ozeri Fan manuals
Popular Fan manuals by other brands

Home Decorators Collection
Home Decorators Collection ALTURA 60-ATO Use and care guide

Ebmpapst
Ebmpapst A6E630-AN01-02 operating instructions

Rubine
Rubine RCF-PA200-5BL user manual

Hunter
Hunter Kaplan 59322 installation manual

IRIT
IRIT IRV-002 Manual instruction

Commercial Electric
Commercial Electric HVFF10CE Use and care guide

Ruck Ventilatoren
Ruck Ventilatoren EL 125 E2M 01 manual

MALTEC
MALTEC WK120Wt Operation and maintenance manual

Delta Electronics
Delta Electronics GFB0912HHG Dimensions and installation information

KAZE APPLIANCES
KAZE APPLIANCES SEP120 manual

Dyson
Dyson AM 08 operating manual

SagiCofim
SagiCofim DIF.P Assembly, installation and maintenance manual