• Make sure that no one is entering the space during treatment.
• Ensure that ozone does not leak to nearby areas where plants, animals
and humans are present while the treatment is in progress.
The time before a space can be entered after treatment is two hours.
If the space needs to be entered more quickly, ventilate properly and
make sure all ozone is gone.
• Ensure that no plants, animals or humans are present in the area
before treatment begins.
• Close and seal the space to avoid leakage of ozone to nearby areas
where plants, animals and humans are located.
• Make sure the product is set to match the size of the area being
treated. See “Auto Mode”
During use
After use
Before use
When using the product, certain safety
precautions must be followed to reduce the risk
of personal injury or property damage.
SAFETY GUIDELINES
02
WARNING! - Always pay attention to any ozone-re-
lated symptoms such as irritation of the eyes, throat
and nose. Leave the space if any symptoms appear
and let the ozone completely disappear.
WARNING! – Incorrect setting of the product may
cause permanent damage to property.
NOTE – Use the included door hanger to prevent peo-
ple from entering the area during ongoing treatment.
8
Ozoneair uses corona discharge to convert
oxygen (O2) to ozone (O3). When used correctly,
it can permanently oxidize organic compounds
(odorants, bacteria, mold, virus, etc.) at the
molecular level.
DESCRIPTION & SPECIFICATIONS
03
Operating temperature:
Relative humidity:
Operating altitude:
0 °C till 35 °C
5 % till 95 % (noncondensing)
tested up to 5 000 meters
Operating requirements
CE - Ozoneair are CE marked and comply with the RED
Directive (2014/53/ EU), the EMC Directive (2014/30/
EU), and the Low Voltage Directive (2014/35/EU) issued
by the European Commission.
RoHS – Ozoneair complies with the RoHS Directive
(2002/95 / EC) which prohibits the use of hazardous
substances in electronic equipment.
Certifications
Technical details
9
Model:
Line voltage/Frequency:
Eect:
Height:
Width:
Depth:
Weight:
GO
220-240 V/50-60 Hz
60 W
25,0 cm
15,5 cm
24,0 cm
2,9 kg