Developed by a physician, Buzzy® is a
reusable device for minor aches and pains.
Buzzy®Healthcare is for use in a professional healthcare facility
by trained operator. Reusable pain relief product intended for
multiple users. Thoroughly clean and disinfect Buzzy®and its
accessories between patients following your facility’s infection
control protocol for reprocessing non-critical equipment.
BuzzyHelps.com
For Buzzy®Mini Healthcare (Striped, Black, and LadyBuzz)
and Buzzy®XL Healthcare (Striped, Black, and LadyBuzz)
BKHM1, BKHM2, BKHM3, BTH1, BTH2, BTH3
IFU-001 Rev 00 Buzzy Healthcare Instructions for Use
09.17.2020
Indications For Use:
Controls pain associated with injections (venipuncture, IV
starts, cosmetic procedures) and the temporary relief of
minor injuries (muscle or tendon aches, splinters and bee
stings). Also intended to treat myofascial pain caused by
trigger points, restricted motion and muscle tension.
Warnings:
For intended use only • Direct or prolonged application of ice
could vasoconstrict or alter lab values.
Contraindications:
Do not use in the presence of unexplained calf pain. Consult
a physician. • This device should not be used over swollen or
inamed areas or skin eruptions. • Do not place directly on a
thermal burn • Do not use ice pack with underlying sensitivities
to ice or cold (e.g. Sickle Cell Disease, Reynaud’s Disease).
Cautions:
Store wings in a cool, dry place. • Wings must be frozen solid
for best eect. • Do not use dry ice to freeze wings unless
supervised by a healthcare professional • Do not puncture ice
pack chambers. • Discard if leaking. • Do not ingest gel. • Keep
out of reach of children or pets. • Do not use with neuropathy,
CRPS, or sensitivities to ice.
Model Differences:
Buzzy®Mini: Comes with Buzzy®vibration unit with button
switch and energy saving automatic 3-minute shut-o, four
reusable ice wings and 1 Comfort Strap, and instructions. Press
and hold button rmly until vibration activates.
Buzzy®XL: Comes with Buzzy®vibration unit with toggle switch,
four reusable ice wings and 2 Comfort Straps, and instructions.
Keep the tape on the switch during transport to avoid accidental
activation. Activate with the on/o toggle switch.
Cleaning:
Buzzy®is a reusable medical device that should be thoroughly
cleaned and reprocessed following your facility’s infection
control protocol for non-critical equipment. All accessories
must be cleaned and disinfected with your facility’s disinfecting
wipes or method used to reprocess non-critical equipment
such as stethoscopes or patient monitors. Do not autoclave.
Do not immerse in liquid.
Batteries:
Unscrew the back using a Phillips-head screwdriver to remove
back panel. Buzzy®is powered by 2 alkaline AAA batteries. Remove
batteries if Buzzy®is not being used for extended period of time.
Disposal:
Please contact your local authorities to determine the proper
method of disposal of potentially biohazardous parts and
accessories.
DO NOT SERVICE WHILE IN USE
US Patented British Patent No. 2455695
RM-1910, 1248-064-5002-00, 1248-064-5001-00
Troubleshooting:
With proper care, your Buzzy should last for at least 1
year. With heavy use or extreme temperature uctuations,
batteries may need to be replaced more frequently. If device
stops working, replace batteries. Press switch rmly for 1/2
second to activate or turn o.
How To Order/Additional Information:
Please visit our website buzzyhelps.com for a complete
list of FAQ’s, other pain management tips, how-to videos,
accessories, replacement parts, and more!
Guarantee:
Previous medical history and intrinsic physiologic dierences
may make Buzzy® less eective for some people. If not
completely satised, return within 30 days to place of
purchase for a full refund, or contact us at the address below.
MMJ Labs, LLC dba Pain Care Labs
322 Sutherland Place • Atlanta, GA 30307, U.S.A.
877.805.2899
Authorized European Representative
MPC International S.A.
26, Boulevard Royal • L-2449 Luxembourg
Tel. +352 22 99 99 5546 | www.mpc.cc
M
a
d
e
f
r
o
m
a
t
l
e
a
s
t
3
0
%
p
o
s
t
c
o
n
s
u
m
e
r
w
a
s
t
e
1
0
0
%
B
i
o
d
e
g
r
a
d
a
b
l
e
P
a
c
k
a
g
i
n
g
Indications For Use .......................................... 1
Warnings, Contraindications, Cautions ......... 1
Model Dierences ............................................ 2
Directions For Use ........................................... 3
Ice Wings ................................................... 3, 4
For Injections ................................................ 5
Buzzy®Placement ............................................ 5
Finger Sticks, Splinters ................................ 7
Stomach Injections ...................................... 7
Burning, Itching ............................................ 7
IVs & Phlebotomy, For children .................. 8
Cleaning, Changing Batteries, Disposal ......... 9
Troubleshooting, Ordering, Guarantee ....... 10
Environmental conditions:
Transport and storage
between uses: -25 to 70 °C.
0-95% RH. 700-1060 hPa
Operating conditions:
5-40 °C. 15-95% RH
700-1060 hPa. 2000m altitude
ON
OFF
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
2. “Please note that changes or modications of this product is not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.”
3. NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna. • Increase the separation between the equipment and
receiver. • Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected. • Consult the dealer or an experienced radio/TV technician for help.
4. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation. Pain Care Labs, 195 Arizona Ave • LW08 NE Atlanta GA 30307 • 877-805-2899
(Pain Care Labs Responsible Party in USA.)
Type BF Applied Part
DRAFT

345
678
Place wings in freezer.
(Do not freeze vibration unit). Leave in until frozen solid
(~30-60 minutes). Remove wings from freezer just prior to
use. Wings stay frozen for ~10 minutes at room temp.
Note: To transport, place between 2 commercial cold packs
(sold separately) in an insulated environment to maintain
frozen temperature.
Why Frozen?
Our unique formula freezes solid to transmit vibration;
commercial gels absorb the specic vibration frequency
needed for pain. Ice provides up to 60% of the numbing,
because intense cold causes the brain to inhibit pain
everywhere.
Attach wings to back of
Buzzy®.
Flip switch or press
button firmly to
activate. Buzzy® controls pain on contact.
Place directly on injury or “between the brain and the pain”
for procedures.
For Injections:
Place Buzzy®directly on the injection site for 30-120 seconds.
Leave on longer for larger volumes or more painful injections.
Move 2-3 cm proximal during injection and press in place.
Closer to the injection is better.
TIP: Place Buzzy®’s bigger rounded end as close as possible to
the site of the procedure, with Buzzy®’s switch end furthest
away. During the injection, move Buzzy®2-3 cm toward the
spine along nerve paths (dermatomes) as shown.
Why Does Placement Matter?
Vibration and cold are transmitted together to the same
place in the spine as pain. To block pain, Buzzy®needs
to be on the same nerve paths as the source of the pain.
For finger sticks or
splinter removal:
Press Buzzy®onto the palm
with the bottom end toward
the nger. Leave in place
throughout cleaning and
during the procedure.
For burning or itching:
For insect bites or medications
that cause burning or itching,
put Buzzy®directly on the site.
Rub or press in place until the
area feels better.
For injections in the
stomach:
Place the injection on a
horizontal line between the
belly button and Buzzy®.
For IVs or phlebotomy:
Do not put directly on the site
of access.
Activate, then hold or tuck
Buzzy®under the tourniquet
3-5 cm above (proximal to)
the access site. Clean site and
access without delay. Optional:
Pass tourniquet through the
slot of Buzzy®XL to secure
Buzzy®to arm.
For children:
Let children hold Buzzy®in advance for familiarity, and
let them choose whether or not to use the ice pack. For
vaccinating children sitting up, a parent can put an arm
around the child’s shoulders and hold Buzzy®for them.
Directions For Use: Buzzy®Placement:
T8
T9
T10
T11
T12
L1 L4
L3
L2
L1
T12 T11
C5-6
T1
For additional placement information,
please visit: bzy.fyi
1 2
3
4
DRAFT
This manual suits for next models
1
Other Pain Care Labs Personal Care Product manuals