
1 2
109
Bring to the doctor or use at home for
splinters, shots, stings, and more.
Buzzy®is a personal consumer use product intended to be
used by a single user. For use in home healthcare environment
by lay operator.
BuzzyHelps.com
For Buzzy®Mini Personal (Striped, Black, and LadyBuzz) and
Buzzy®XL Personal (Striped, Black, and LadyBuzz)
BKM1, BKM2, BKM3, BKT1, BKT2, BKT3
IFU-002 Rev 00 BuzzyPersonal Instructions for Use
09.17.2020
Indications For Use:
Controls pain associated with injections (venipuncture, IV
starts, cosmetic procedures) and the temporary relief of
minor injuries (muscle or tendon aches, splinters and bee
stings). Also intended to treat myofascial pain caused by
trigger points, restricted motion and muscle tension.
Warnings:
For intended use only • Direct or prolonged application of ice
could vasoconstrict or alter lab values.
Contraindications:
Do not use in the presence of unexplained calf pain. Consult
a physician. • This device should not be used over swollen or
inamed areas or skin eruptions. • Do not place directly on a
thermal burn • Do not use ice pack with underlying sensitivities
to ice or cold (e.g. Sickle Cell Disease, Reynaud’s Disease).
Cautions:
Store wings in a cool, dry place. • Wings must be frozen solid
for best eect. • Do not use dry ice to freeze wings unless
supervised by a healthcare professional • Do not puncture ice
pack chambers. • Discard if leaking. • Do not ingest gel. • Keep
out of reach of children or pets. • Do not use with neuropathy,
CRPS, or sensitivities to ice.
Model Differences:
Buzzy®Mini: Comes with Buzzy®vibration unit with button
switch and energy saving automatic 3-minute shut-o, two
reusable ice wings and instructions. Press and hold button
rmly until vibration activates.
Buzzy®XL: Comes with Buzzy®vibration unit with toggle switch,
two reusable ice wings, a hands free strap, and instructions.
Keep the tape on the switch during transport to avoid accidental
activation. Activate with the on/o toggle switch.
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
2. “Please note that changes or modications of this product is not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.”
3. NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna. • Increase the separation between the equipment
and receiver. • Connect the equipment into an outlet on a circuit dierent from that to which
the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
4. This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation. Pain Care Labs, 195 Arizona Ave • LW08 NE Atlanta GA 30307 • 877-805-2899
(Pain Care Labs Responsible Party in USA.)
Cleaning:
Buzzy®is a personal consumer product intended to be used
by a single user. Buzzy®may be cleaned with alcohol based
sanitation wipes. Do not autoclave. Do not immerse in liquid.
Soiled wings should be disposed of and replaced.
Batteries:
Unscrew the back using a Phillips-head screwdriver to remove
back panel. Buzzy®is powered by 2 alkaline AAA batteries.
Remove batteries if Buzzy® is not being used for extended
period of time.
Disposal:
Please contact your local authorities to determine the proper
method of disposal of potentially biohazardous parts and
accessories.
US Patented British Patent No. 2455695
RM-1910, 1248-064-5002-00, 1248-064-5001-00
Indications For Use .......................................... 1
Warnings, Contraindications, Cautions ......... 1
Model Dierences ............................................ 2
Directions For Use ........................................... 3
Ice Wings ................................................... 3, 4
For Injections ................................................ 5
Buzzy®Placement ............................................ 5
Finger Sticks, Splinters ................................ 7
Stomach Injections ...................................... 7
Burning, Itching ............................................ 7
IVs & Phlebotomy, For children .................. 8
Cleaning, Changing Batteries, Disposal ......... 9
Troubleshooting, Ordering, Guarantee ....... 10
M
a
d
e
f
r
o
m
a
t
l
e
a
s
t
3
0
%
p
o
s
t
c
o
n
s
u
m
e
r
w
a
s
t
e
1
0
0
%
B
i
o
d
e
g
r
a
d
a
b
l
e
P
a
c
k
a
g
i
n
g
Environmental conditions:
Transport and storage
between uses: -25 to 70 °C.
0-95% RH. 700-1060 hPa
Operating conditions:
5-40 °C. 15-95% RH
700-1060 hPa. 2000m altitude
Type BF Applied Part
DO NOT SERVICE WHILE IN USE
Troubleshooting:
With proper care, your Buzzy® should last for at least 1
year. With heavy use or extreme temperature uctuations,
batteries may need to be replaced more frequently. If device
stops working, replace batteries. Press switch rmly for 1/2
second to activate or turn o.
How To Order/Additional Information:
Please visit our website buzzyhelps.com for a complete
list of FAQ’s, other pain management tips, how-to videos,
accessories, replacement parts, and more!
Guarantee:
Previous medical history and intrinsic physiologic dierences
may make Buzzy® less eective for some people. If not
completely satised, return within 30 days to place of
purchase for a full refund, or contact us at the address below.
MMJ Labs, LLC dba Pain Care Labs
322 Sutherland Place • Atlanta, GA 30307, U.S.A.
877.805.2899
Authorized European Representative
MPC International S.A.
26, Boulevard Royal • L-2449 Luxembourg
Tel. +352 22 99 99 5546 | www.mpc.cc