Quick Start Guide
Z-Series Quick Start Manual
Command Key1 Key2 Keys 3 and 4 Key5
Exit Programming
Mode
* #
1.5.1 Relay Funcons
The table below is for use for the relay programming opons menoned in the table on the previous page.
Keys 3
and 4
Funcon Descripon
00 Fence Triggers when Zone 1 is Armed and Return Voltage is below the Threshold Voltage
In Bipolar - Triggers when the posive output is below the Threshold Voltage
01 Fence or O Triggers when Zone 1 is Disarmed or Return Voltage is below the Threshold Voltage
02 Armed Zone 1 is Armed
03 Fence 2 Bipolar only - Triggers when the negave output is below the Threshold Voltage
06 Fence Bi-Polar Triggers when energizer is Armed and the fence Return Voltage on either Bi-Polar re-
turn line has fallen below the Threshold Voltage
07 General Triggers on AC Fail, Tamper, Low Baery/Bad Baery, Gate Alarm or Internal error.
Latched (internal errors only)
08 Siren Triggers on Fence Alarm, Gate or Tamper. Will me out aer the Siren Time Out me.
Latched
09 Strobe Triggers on Fence alarm, Gate or Tamper. Only turns o on Energizer Disarm. Latched
10 AC Fail Triggers on AC Fail