Panasonic EW6011 User manual

EU Representative/Mandataire
Panasonic Marketing Europe GmbH
Hagenauer Straße 43-D65203,Wiesbaden, Germany
Legal Manufacturer/Fabricant
Matsushita Electric Works, Ltd.
33 Okamachi, Hikone, Shiga 522-8520, Japan B No. 1
Lesen Sie diese Bedienungsanleitung vor Inbetriebnahme des Geräts vollständig durch und bewahren Sie sie sorgfältig auf.
Before operating this device, please read these instructions carefully and save this manual for future reference.
Avant díutiliser ce dispositif, veuillez lire entièrement ces instructions et rangez soigneusement ce manuel pour le consulter par la suite.
Prima di mettere in funzione questo apparecchio leggere completamente le presenti istruzioni, e conservare questo manuale per
líutilizzo futuro.
Antes de utilizar este dispositivo, lea completamente estas instrucciones y conserve este manual para futura referencia.
ѕеред использованием прибора, пожалуйста прочтите полностью эти инструкции и сохраните данное руководство для
использования на будущее.
Niederfrequenz Muskel- und Nervenstimulator
Low-Frequency Muscle and Nerve Stimulator
Bedienungsanleitung
Operating Instructions
Model No. EW6011

DE1
Mit dem Niederfrequenz Muskel- und Nervenstimulator von Panasonic, können Sie Schulter- und
Nackenschmerzen, Verspannungs-Kopfschmerzen, Zerrungen, Prellungen und Muskelkater etc. selbst
behandeln. Im Bereich der Muskulatur wird neben einer sanften Schmerzlinderung eine nachhaltige
Muskellockerung erreicht.
Der Niederfrequenz Muskel- und Nervenstimulator von Panasonic wirkt mit sanften Reizen, die „elektronisch
gesteuerte Pflaster“ auf die schmerzenden verspannten Körperpartien übertragen. Diese Therapiereize
dringen tief in das Gewebe ein und erzeugen dort eine nachhaltige Muskellockerung, verbessern die
Durchblutung und bewirken deshalb in der Regel auch eine deutliche Schmerzlin-derung.
Einfach die Panasonic Pflaster auf die Körperpartien kleben, die Sie behandeln möchten. Die Pflaster liegen
flach auf der Haut und beeinträchtigen nicht. Die Steuerung der Panasonic Therapiereize erfolgt ganz einfach
mittels Handbedienung.
Stromversorgung 2#1,5V Alkali-Batterien, Typ: LR03/AAA.
Bedienungsanleitung DE1-24
Operating Instructions GB1-24
Mode d'emploi FR1-24
Istruzioni d'uso IT1-24
Instrucciones de funcionamiento SP1-24
Инструкция по эксплуатации
RUS1-24
TR1-24
BEWAHREN SIE DIESE BEDIENUNGSANLEITUNG BITTE AUF!
SAVE THESE INSTRUCTIONS
CONSERVEZ CES INSTRUCTIONS
CONSERVARE QUESTE ISTRUZIONI
CONSERVE ESTAS INSTRUCCIONES
СОХРАНИТЕ ЭТИ ИНСТРУКЦИИ
D
GB
F
I
E
RUS
TR

DE24
Empfohlener Abstand zwischen tragbaren und mobilen HF-Kommunikationsgeräten und dem EW6011
Das Modell EW6011 ist für die Verwendung unter den elektromagnetischen Bedingungen, mit Abschirmung gegen HF-Störu-
ngen vorgesehen. Der Kunde oder der Benutzer des EW6011 kann elektromagnetische Störungen verhindern, wenn zwischen
tragbaren und mobilen HF-Kommunikationsgeräten (Sender) und dem EW6011 der empfohlene Minimalabstand eingehalten
wird, der von der maximalen Ausgangsleistung des Kommunikationsgeräts abhängig ist, wie nachstehend aufgeführt.
Für Sender, dessen maximale Leistung in der vorstehenden Tabelle nicht aufgeführt ist, kann der empfohlene Abstand
d
in
Metern (m) mit der Gleichung für die Senderfrequenz berechnet werden, dabei ist
P
die maximale Ausgangsleistung des
Senders in Watt (W), die vom Hersteller angegeben wird.
HINWEIS 1: Bei 80 MHz und 800 MHz gilt der Abstand für den höheren Frequenzbereich.
HINWEIS 2: Diese Richtlinien sind nicht in allen Situationen anwendbar. Die elektromagnetische Ausbreitung wird durch
die Reflexion an Gebäuden, Gegenständen und Personen beeinflusst.
Nennleistung des Senders
W
0,01
0,1
1
10
100
Abstand entsprechend der Senderfrequenz
m
150 kHz bis 80 MHz
d = 1,2
√
—
P
0,12
0,38
1,2
3,8
12
80 MHz bis 800 MHz
d = 1,2
√
—
P
0,12
0,38
1,2
3,8
12
800 MHz bis 2,5 GHz
d = 2,3
√
—
P
0,23
0,73
2,3
7,3
23
Benutzerinformationen zur Entsorgung von elektrischen und elektronischen Geräten
(private Haushalte)
Entsprechend der grundlegenden Firmengrundsätzen der Panasonic-Gruppe wurde ihr Produkt aus
hochwertigen Materialien und Komponenten entwickelt und hergestellt, die recycelbar und wieder
verwendbar sind.
Dieses Symbol auf Produkten und/oder begleitenden Dokumenten bedeutet, dass elektrische und
elektronische Produkte am Ende ihrer Lebensdauer vom Hausmüll getrennt entsorgt werden müssen.
Bringen Sie bitte diese Produkte für die Behandlung, Rohstoffrückgewinnung und Recycling zu den eingerich-
teten kommunalen Sammelstellen bzw. Wertstoffsammelhöfen, die diese Geräte kostenlos entgegennehmen.
Die ordnungsgemäße Entsorgung dieses Produkts dient dem Umweltschutz und verhindert mögliche schädliche
Auswirkungen auf Mensch und Umwelt, die sich aus einer unsachgemäßen Handhabung der Geräte am Ende
Ihrer Lebensdauer ergeben könnten.
Genauere Informationen zur nächstgelegenen Sammelstelle bzw. Recyclinghof erhalten Sie bei Ihrer
Gemeindeverwaltung.
Für Geschäftskunden in der Europäischen Union
Bitte treten Sie mit Ihrem Händler oder Lieferanten in Kontakt, wenn Sie elektrische und elektronische Geräte
entsorgen möchten. Er hält weitere Informationen für sie bereit.
Informationen zur Entsorgung in Ländern außerhalb der Europäischen Union
Dieses Symbol ist nur in der Europäischen Union gültig.
GB1
Panasonic low-frequency muscle and nerve stimulator is a muscle and nerve stimulator which
allows you to treat shoulder and neck pain, strains, bruises, sore muscles, etc. yourself. The effects
on the muscles include thorough relaxation and gentle pain relief.
Panasonic low-frequency muscle and nerve stimulator is based on gentle stimulation transferred to
the hurting and tense body parts by way of “electronically controlled pads”. This therapeutic
stimulation penetrates deep into the tissue where it relaxes the muscles thoroughly and improves
blood circulation, thereby usually also providing noticeable pain relief.
Simply place the Panasonic pads on the parts of your body that you wish to treat.The pads are flat
and convenient. A hand-held unit facilitates convenient control of the therapeutic stimulation.
Power supply: 2#1.5 V alkaline batteries, type: LR03/AAA.

GB3
Storage case
(See page GB14 for the storage method.)
Pad storage plate
Conductive pad plugs
Pad grip
Pad
Cord take-up
stopper
Terminal
Adhesive surface
(rear)
Film
Check the contents of the package.
Main unit Replacement
pads#2Storage case LR03/AAA
batteries#2
Pad storage
plate#1
GB2
PARTS IDENTIFICATION
Main unit
Cord take-up switch
(side)
Slide switch used when
storing the cord.
Battery cover
(rear)
Power/strength dial
Program location selection button
Manual operation selection button
Stimulation mode switching button
Cord opening
Cord end line (red)
Cord

GB5
[a]
[b]
• Do not excessively bend or pull the cord.
• Do not hold the main unit by the cord or twirl the main unit.
• Do not pull the cord from the cord opening at an angle, sideways, or from behind.
- Doing so may result in cord damage or malfunction.
• Do not hold only one pad attached with a cord or conductive pad plug and pull on the cord.
- Doing so may result in entangling the cord and prevent it from being pulled out.
Note: Extend the cord by pulling on both pads.
Handling the cord
PREPARING THE CORD AND PADS
1Check that the power/strength dial is set to “O”.
2Check that the cord and pads are connected and
attached to the pad storage plate.
When used for the first time
• Take out the pads from the clear bag.
• Peel off the clear film from the pads.
(The peeled off film is made of PET plastic and can be
discarded.)
• Attach the pads to the pad storage plate. (Fig. a)
• Firmly connect the conductive pad plugs to the pads. (Fig. b)
• Although the conductive pad plugs are color coded with red
and white, either plug may be connected to either pad.
3Extend the cord.
• Hold the main unit and the pad storage plate that has been
attached with the pad and extend the cord straight down.
• Do not extend the cord beyond the red line of the cord end line.
• The length of the cord can be adjusted as desired.
GB4
3
2
4
• When non-alkaline batteries are used, the battery life may shorten noticeably.
• When replacing the batteries, be sure to replace both batteries with two fresh batteries of the
same type.
• Battery life may shorten if the room temperature is low.
• Discard used batteries properly.
Handling the batteries
When the treatment stimulus feels weak or when the output stops before 15 minutes of use, the
batteries may have become exhausted. Replace them with fresh batteries.
When to replace the batteries
CAUTION!
• Be sure to observe the precautions shown on the batteries.
• Check for correct polarity of the batteries before loading.
• Promptly remove exhausted batteries.
• Remove the batteries if the device is not to be used for a prolonged period of time.
• Use the batteries before their recommended expiration date.
- Failure to do so may cause injury due to battery heat generation, bursting, or leakage, or
cause staining of the surroundings.
LOADING THE BATTERIES
We recommend the use of Panasonic alkaline batteries. (2 LR03/AAA batteries)
Manganese batteries or nickel hydroxide batteries can be used.
1Check that the power/strength dial is set to “O”.
• Lamp turns off.
2Detach the battery cover on the rear of the
main unit.
• Detach the battery cover in the direction of the arrow
while gently pressing the mark.
3Load the batteries while checking their
polarities.
• Do not let dust or other foreign matter get inside the
battery compartment, otherwise it may cause a
malfunction.
4Attach the battery cover on the rear of the
main unit.
Battery life
Approximately 90 operations are possible when using Panasonic alkaline batteries (2 LR03/AAA
batteries). (Approximately 3 months when used for 15 minutes once a day at a strength setting of
10 and a room temperature of 23°C.)

GB7
ATTACHING THE PADS TO THE AREA TO BE TREATED
Wipe the skin to clean off perspiration, moisture and dirt.
Hold the pad grip and peel off the pad from the pad storage plate
and attach the pads, one at a time, to the area to be treated.
Attach the pads securely to the skin.
(If a pad falls off the skin for approximately 30 seconds during operation,
the power automatically turns off.)
• The intensity of the stimulus between the pads may differ depending on
location.
If the stimulus is weak, move the position of the pads.
Examples of attaching the pads
Neck
Attach the pads to the base of
the neck.
* If the pads are attached to the
head or nape of the neck, hair
may stick to the pads or
stimulus to the back of the
head may increase.
Joints
• Emphasis on one side
Attach the pads on both sides of the joint
to be treated.
Shoulders
Attach the pads symmetrically to
the left and right shoulders with
your backbone in the middle.
Arms and legs
• Arm
Attach the pads
one above the
other on the
arm.
Waist
Attach the pads symmetrically to
the left and right waist with your
backbone in the middle.
• Leg
Attach the
pads one
above the
other on
the calf.
• Both knees at
the same time
Attach the pads
below the knees.
Soles of the feet
• Emphasis on one side
Attach the pads
to the arch and
the calf.
Attach the pads
to the ball of the
foot and the heel.
• Both feet at the
same time
Attach the pads
to the arches.
GB6
1Without pulling on the cord, attach both pads to the pad storage plate.
2With the cord take-up switch slid in the direction of
the arrow, hold the pad storage plate that has been
attached with both pads and pull gently.
Note: If the cord takes on a bend or is twisted, the cord may become difficult to take up. In this case,
gently sandwich the cord in a cloth and pull the cord to straighten as if cleaning it.
If a cord gets tangled and does not come out
Preparing the Cord and Pads (cont.)

GB9
WARNING!
• Do not use this device for any purpose other than therapy.
- Doing so may result in an accident or injury.
• Do not use this device simultaneously with other medical devices or in combination with
medicinal ointments (or sprays).
- Doing so may cause an accident or health problems.
• Do not immerse the pads into water, splash water on the pads, or take a bath with the product
in operation.
• Do not use the product where there is high humidity, such as in a bathroom.
- Doing so will result in a strong electric shock.
• During operation, keep the pads away from metallic objects, such as belt buckles or
necklaces.
- Doing so may result in a strong electric shock or burns.
• Do not allow children or persons who are unable to express themselves to use the device.
• Also do not allow persons who are unable to operate the device by themselves to use the
device.
- Doing so may result in an accident or injury.
GB8
• Attach the pads to the skin so they do not overlap.
• Do not bend the pads.
• Try to avoid touching the adhesive surface with your fingers.
• If the pads lose their adhesive strength, clean them. (See page GB15.)
• Do not use the pads when they are wet.
Shake off any water and air-dry the adhesive surfaces before using the pads.
Handling the pads
DANGER!
• Never use the product in combination with the following medical devices:
(1) Implanted electronic medical device, such as a pacemaker
(2) Life support medical device, such as a heart-lung machine
(3) Attached medical device, such as an electrocardiograph
- Doing so may cause an accident or noticeable bodily impairment.
WARNING!
• The following persons should consult with a physician before using this product and when
undergoing treatment:
(1) Those with an acute illness
(2) Those with malignant tumors
(3) Those with an infectious disease
(4) Those who are pregnant, menstruating, or who have recently given birth
(5) Those with heart problems
(6) Those having a body temperature (fever) of 38°C or higher
(Example: when feeling weak or having severe symptoms of acute inflammation, such as
malaise, chills, or fluctuating blood pressure)
(7) Those who are anemic
(8) Those with an abnormal skin condition (infectious disease or injury)
(9) Those suffering from abnormally high blood pressure (180 mmHgor higher)
(10) Those requiring rest or in physically poor shape
(11) Those with acute pain, such as backbone fracture, sprain, torn muscle, etc.
(12) Those with sensory loss caused by advanced peripheral circulatory disorders, such as
due to diabetes
(13) Besides the above, those feeling physical discomfort
- Failure to do so may result in an accident or health problems.
• Be sure to turn off the power before attaching, reattaching or detaching the pads.
- Failure to do so may result in a strong electric shock or burn.
• Do not wrap the cord while the pads are attached to your skin.
• Wrap the cord after attaching the pads to the pad storage plate.
- Failure to do so may result in injury.
• Do not use the device on areas close to the heart, on the face or head, in the mouth, genitals,
or where there is a skin disease.
- Doing so may cause an accident or health problems.
• Do not use the device while you are asleep.
- Doing so may cause an accident or injury, such as with the cord becoming entangled around
your neck. Furthermore, the pads may attach to another part of the body (near the heart, on
the face or head, in the mouth, genitals, or where there is a skin condition) and cause an
accident or health problems.

GB11
Click
4Turn off the power after the treatment.
Turn the power/strength dial to “O”.
• A click is heard and the power turns off.
• The power will automatically turn off approximately 15
minutes after the start of the treatment.
Even if the power automatically turns off, turn the
power/strength dial to “O”.
5Remove the pads from the skin.
Hold the pads by the grip and remove.
• Remove the pads slowly from the skin.
Removing the pads quickly may cause a skin inflammation
or body hair to be pulled out.
6Store the pads. (See page GB14.)
• Attach the pads to the pad storage plate.
If the pads become dirty, they may fall off easily during
treatment.
Click
1
2
GB10
1Turn on the power.
Turn the power/strength dial.
• A click is heard, the power turns on, and the neck program
“ ” begins.
Soft start function
• This function gently starts with a weak stimulus to
prevent the sudden application of strong stimulus.
• When the power is turned on, the lamp for the neck program
flashes and the lamp for the “Local” stimulus mode turns on.
• Start at a low setting between “O” and “2” for around 3
minutes to allow your body to adjust to the sensation, then
increase the strength to the desired level.
(Persons who have sensitive skin should shorten the time
and start from a low setting.)
• The power will automatically turn off approximately 15
minutes after it is turned on.
(The power will automatically turn off approximately 15
minutes after it is turned on even if the position or
operation is changed.)
• If the power is turned on without attaching the pads, the
power will automatically turn off after approximately 30
seconds.
Treatment Guide
Time: Up to 15 minutes per position
Frequency: Once a day per position
Strength: Any level that feels comfortable
USING THE LOW-FREQUENCY MUSCLE AND NERVE STIMULATOR
2Select the treatment method.
Program Go to page GB12.
Manual Go to page GB13.
Stimulus mode Go to page GB13.
Note: The stimulus mode can be switched in either the program or manual treatment.
3Adjust the strength of the stimulus.
(1) Turn the power/strength dial.
(2) Select a desired strength between “I” and “10”.
• Indiscriminately setting the strength to high may not necessarily
increase the beneficial effect of stimulation. Doing so may
excessively stimulate the skin and cause tingling and redness.

GB13
Press .
• The tapping “ ” lamp flashes and the treatment begins.
• The program lamp turns off.
• Select the desired treatment type from tapping “ ”, kneading “ ”, pressing “ ”, and
rubbing “ ”.
• The stimulus mode does not change for the tapping treatment.
• When the stimulus mode is changed, the strength of the stimulus may feel different. In this case,
adjust the strength as desired.
Repeatedly pressing the button changes the treatment type and the selected treatment lamp
flashes.
The treatment type changes in this order:
Changing the manual treatment Press .
Repeatedly pressing the button changes the stimulus mode and the selected mode lamp lights.
The stimulus mode changes in this order:
Switching the stimulus mode Press .
Local Wide
• Switching the stimulus pattern for the treatment.
• Local: Treatment is performed alternately at the pad positions.
• Wide: Treatment is performed simultaneously at the pad positions.
Switching the stimulus mode
Manual treatment
GB12
Using the Low-Frequency Muscle and Nerve Stimulator (cont.)
(Neck): Mainly rubs to gently loosen the neck.
(Shoulder): Firmly taps to loosen the shoulders.
(Joint): Relieves joint pain with fine vibrations.
(Waist): Loosens the large waist muscles with a grasping massage.
(Arm/Leg): Taps and grasps to loosen muscles.
(Sole): Mainly taps to massage away sole fatigue.
• If the attached position of the pads and the selected program are different, the program
may not be suitable for the position and the beneficial effect may not be obtained.
Be sure to select the program to match the position of the attached pads.
Program type
• Be sure to turn off the power then change the positions of the pads.
• Again turn on the power then select the desired program.
When changing the treatment position
• Select where to attach the pads.
Program treatment
Repeatedly pressing the button changes the program and the selected program lamp flashes.
The program changes in this order:
Changing the program Press .

GB15
Thinner
Benzine
Alcohol
MAINTENANCE AND STORAGE
* First check that the power is off.
Wipe the main unit with a cloth lightly dampened with
lukewarm water.
• Never use thinner, benzine or alcohol.
Doing so may result in malfunction or cracking or
discoloration of parts.
• Do not disassemble the main unit, drop it from a high
position, or apply an unreasonable force on the main unit.
• Do not place the device in locations having a high temperature or humidity or in direct sunlight.
• Remove the batteries if the device is not to be used for a prolonged period of time.
CAUTION!
• Store the device in a place that is out of reach of children.
- Failure to do so may result in an accident or trouble.
Back side
(adhesive
surface)
IF THE PADS LOSE THEIR ADHESIVENESS
The pads can be used approximately 400 times (with washing in cold water).
If the pads become dirty and lose their adhesiveness (usually after 15-20 times), they can be
washed in water to restore their adhesiveness.The pads can be washed in this way about 20
times. (The useful life of the pads may be shortened by factors such as how often they are washed,
how they are stored, and skin condition.)
1Remove the conductive pad plugs from the pads.
• The conductive pad plug connectors may rust if they become wet.
2
Use your fingertips to gently wash the adhesive surface of the pad
with a small amount of running water for about 10 seconds or less.
• Do not rub the adhesive surface with your fingernails or a brush.
• Do not use detergents.
• Do not knead or soak the pads.
3Shake off any water, place the pads with their adhesive
surfaces facing up, let the surfaces air-dry, and then attach
the pads to the pad storage plate.
• After washing the pads, do not wipe the adhesive surfaces with a tissue
paper or cloth. Doing so may result in the tissue paper or cloth sticking to the
adhesive surfaces. If they become stuck to the adhesive surfaces by accident, do not forcibly
peel them off but wet the surfaces and they will easily come off.
• The pads are consumable items. If the adhesive surfaces become worn or damaged,
purchase new pads.
OPTIONAL ITEMS
Replacement pads (two)
EW0603
GB14
STORAGE
1Check that the power/strength dial is at the “O”
position.
2Attach the pads to the pad storage plate.
• Untwist the cords before attaching the pads.
Failure to do so may prevent the cord from being taken up all the
way.
3Take up the cord.
• Slide the cord take-up switch on the side of the main unit in the
direction of the arrow.
• Take up the cord while making sure the cord is not twisted.
If the cord is taken up while twisted, this may prevent the cord
from being taken up all the way.
• If the cord take-up stops midway, pull out the cord a little and
again take up the cord.
The cord take-up has been designed to operate at a safe speed to
prevent injury.
4Store the pad storage plate into the storage case.
• Place the pad storage plate (attached with pads) into the storage
case.
5Place the main unit on top of the storage case.
• Be sure the cord is not sandwiched between the main unit and the
case.
- Doing so may damage the cord.
WARNING!
• Do not wrap the cord while the pads are attached to your skin.
• Wrap the cord after attaching the pads to the pad storage plate.
- Failure to do so may result in injury.

GB17
TROUBLESHOOTING
If the device does not appear to be working properly, refer to the following to determine the possible
cause of the problem:
SPECIFICATIONS
Power supply: Two 1.5-V (LR03/AAA) batteries
Dimensions (W#H#D): 59#205#22 mm
Weight: Approx. 146 g(not including batteries)
If the device still does not function properly, discontinue use and contact an authorized service
center or the store from which the device was purchased.
Problem
Operation lamp does not light up.
No stimulation is felt.
No stimulation is felt.
Stimulation is weak or it tingles.
The device stops functioning even if it
has not been used for 15 minutes.
Even when set to a stronger power level,
stimulation is weak or cannot be felt.
Cord does not come out.
Cord does not retract.
Possible cause and solution
Are the batteries worn out and need replacing?
Are the batteries inserted correctly according to the (+)
and (–) polarity markings and are the contacts clean?
(See page GB4.)
Are the pads clean? (See page GB15.)
The batteries are exhausted. Replace the batteries.
(See page GB4.)
Reposition the pads. (See page GB7.)
Moisten and warm the treatment area with a steamed
towel before use.
Is the cord tangled? (See page GB6.)
If you can see the cord end line (red line), do not extend
the cord any further.
WARNING!
• Never attempt to modify, disassemble, or repair the unit.
- Doing so may result in an accident, trouble or malfunction.
• If no improvement is seen after a period of use, consult a physician or medical specialist.
GB16
Q&A
We answer frequently asked questions about low-frequency muscle and nerve stimulation.
What is low-frequency muscle and nerve stimulation?
It is a type of physical therapy to help the body recover naturally from pain due to stiff muscles.
A weak electrical current (at low frequency) is passed through the body. The resultant stimulation
directly massages the muscles, calms excited nerves, and improves blood circulation.
Q1 How long should the massage be?
A1 The basic treatment time for one position is approximately 15 minutes. If this time is
exceeded, the result may be detrimental.
Q2 How many places can be treated?
A2 As many places as you desire can be treated in one day. However, please observe the limit
of 15 minutes for one position.
Q3 When should the treatment be done?
A3 The treatment is ideally done after a bath. The body is warm and blood circulation
improves. Be sure to wipe off all perspiration and water from the skin before use.
Q4 Why are there instances when the device should not be used?
A4 • During a fever: The illness may worsen.
• While menstruating: The treatment may interfere with the menstrual cycle and impair
health.
• During pregnancy or after giving birth: Hormones are not balanced.
• High blood pressure: The treatment would place an unreasonable load on the blood
vessels. In particular, the device must never be used on the head.
Please consult a physician in the above cases.
Q5 How do the benefits differ among the various types of stimulation such as tapping,
kneading, pressing, and rubbing?
A5 Depending on the purpose, a frequency up to 1200 Hz can be used for the low-frequency
muscle and nerve stimulation. The characteristics are said to differ according to the
frequency as follows.
Low frequency characteristics:
Ideal for the relief of muscle aches and persistence of pain relief. The pumping action due
to muscular contraction improves blood circulation and the secretion of pain suppressing
substances increases. This product uses four low frequencies: 3-5 Hz (tapping), 40 Hz
(pressing), 50 Hz (kneading), and 83.3 Hz.
High frequency characteristics:
Muscular contraction is harder to attain and the stimulation feels weaker compared to the
low frequencies.The benefits include instant pain relief and the blocking of pain
transmission.
This product uses three frequencies: 100 Hz (rubbing), 120 Hz, and 1200 Hz.

GB19
SAFETY PRECAUTIONS
To ensure proper operation of this appliance, please carefully read all the safety precautions before
use.
These safety precautions are provided to instruct you with the correct and safe operation of this
appliance so that you can avoid injuries to yourself and others as well as damage to property.
The safety precautions are defined as follows.
ALWAYS FOLLOW THESE IMPORTANT SAFETY PRECAUTIONS!
DANGER:
This message indicates potentially and imminently hazardous actions and situations, which, if not
avoided, could result in death or serious injury.
WARNING:
This message indicates potentially hazardous actions and situations, which, if not avoided, could
result in death or serious injury.
CAUTION:
This message indicates potentially hazardous actions and situations, which, if not avoided, could
result in personal injury or damage to property.
Safety Precaution Symbols
A circle and slash symbolizes prohibited actions and behaviors.
A solid circle denotes mandatory actions and instructions to be followed for safe operation.
After reading these safety precautions, store the manual where it is accessible to the user(s).
GB18
TECHNICAL DATA
Infinitely adjustable:
Output voltage Tapping impulse: 61 ±13 VMax, 3.0 ±0.7 mAMax
Pressing impulse: 62 ±12 VMax, 6.5 ±1.3 mAMax
Kneading impulse: 55 ±11 VMax, 5.5 ±1.2 mAMax
Rubbing impulse: 40 ±7 VMax, 8.0 ±1.5 mAMax
Neck program: 62 ±12 VMax, 8.0 ±1.5 mAMax
Shoulder program: 61 ±13 VMax, 8.0 ±1.5 mAMax
Joint program: 55 ±11 VMax, 8.0 ±1.5 mAMax
Waist program: 62 ±12 VMax, 8.0 ±1.5 mAMax
Calve program: 61 ±13 VMax, 8.0 ±1.5 mAMax
Arches program: 61 ±13 VMax, 8.0 ±1.5 mAMax
Length of impulse: 300 µs
Impulse polarity: automatic alternation
Infinitely adjustable stimulation frequency:
Tapping impulse: 3-5Hz
Pressing impulse: 40Hz
Kneading impulse: 50Hz
Rubbing impulse: 100Hz
The technical data refer to a 500 Ohm load resistor.
Programs: 15 minutes of alternating activity patterns (therapy stimuli) for each program
Tu r ns itself off automatically after 15 minutes.
Batteries: 2#1.5 alkaline (LR03/AAA)
Life of batteries: approx. 200 treatments @ 15 minutes
Battery check: If the batteries are weak, the machine turns itself off,
and they need to be replaced.
Classification: BF
Transport and storage conditions: Ambient temperature –10°C to +60°C
Relative humidity 10% to 95%
Operating conditions: Ambient temperature +10°C to +40°C
Relative humidity 20% to 85%
The device complies with the European regulations underlying the German law
governing medical products (MPG) and bears the CE mark “CE 0197”.
The device has been subject to quality control and meets the requirements of the
EC Directive 93/42/EEC on medical products.
This device is subject to technical inspection by TÜV Rheinland Product Safety
GmbH and bears the TÜV/GM mark.
Technical safety check
A technical safety check should be conducted after a period of two years. The Panasonic customer
service will do this at cost price.
Neck program: 3-100Hz Calve program: 3-120Hz
Shoulder program: 3-100Hz Arches program: 3-100Hz
Joint program: 50-1200Hz
Waist program: 40-1200Hz

GB21
• Do not use this device for any purpose other than therapy.
- Doing so may result in an accident or injury.
• Do not use this device simultaneously with other medical devices or in combination with medicinal
ointments (or sprays).
- Doing so may cause an accident or health problems.
• Do not immerse the pads into water, splash water on the pads, or take a bath with the product in
operation.
• Do not use the product where there is high humidity, such as in a bathroom.
- Doing so will result in a strong electric shock.
• During operation, keep the pads away from metallic objects, such as belt buckles or necklaces.
- Doing so may result in a strong electric shock or burns.
• Do not allow children or persons who are unable to express themselves to use the device.
• Also do not allow persons who are unable to operate the device by themselves to use the device.
- Doing so may result in an accident or injury.
Do not dismantle!
• Never modify the unit. Also do not attempt to dismantle or repair the unit.
- Doing so may result in an accident, trouble, or malfunction.
CAUTION!
Mandatory!
• Immediately discontinue use and consult a physician if you experience bodily discomfort.
• Discontinue use and consult a physician if you experience symptoms such as rash, redness, or
itching.
- Failure to do so may result in an accident or health problems.
• Do not reattach the pads to another person during operation.
- Doing so may result in a strong electric shock.
• Be careful not to let the cord wrap around your neck.
- Failure to exercise caution may result in an accident or injury.
Prohibited!
• Do not use the device immediately before or while driving an automobile.
- Doing so may result in an accident or trouble.
• Do not leave the pads attached to the skin.
- Doing so may cause a skin inflammation.
• Do not use the device on one location for longer than 15 minutes.
- Doing so may result in health problems due to muscle fatigue.
GB20
DANGER!
Prohibited!
• Never use the product in combination with the following medical devices:
(1) Implanted electronic medical device, such as a pacemaker
(2) Life support medical device, such as a heart-lung machine
(3) Attached medical device, such as an electrocardiograph
- Doing so may cause an accident or noticeable bodily impairment.
• Never use the product while connected to a high-frequency surgical appliance, as this might lead
to burns under the pads.
• Never use a short-wave or micro-wave therapy appliance in the immediate vicinity as this might
lead to the output fluctuation.
WARNING!
Mandatory!
• The following persons should consult with a physician before using this product and when
undergoing treatment:
(1) Those with an acute illness
(2) Those with malignant tumors
(3) Those with an infectious disease
(4) Those who are pregnant, menstruating, or who have recently given birth
(5) Those with heart problems
(6) Those having a body temperature (fever) of 38°C or higher
(Example: when feeling weak or having severe symptoms of acute inflammation, such as
malaise, chills, or fluctuating blood pressure)
(7) Those who are anemic
(8) Those with an abnormal skin condition (infectious disease or injury)
(9) Those suffering from abnormally high blood pressure (180 mmHgor higher)
(10) Those requiring rest or in physically poor shape
(11) Those with acute pain, such as backbone fracture, sprain, torn muscle, etc.
(12) Those with sensory loss caused by advanced peripheral circulatory disorders, such as due to
diabetes
(13) Besides the above, those feeling physical discomfort
- Failure to do so may result in an accident or health problems.
• Be sure to turn off the power before attaching, reattaching or detaching the pads.
- Failure to do so may result in a strong electric shock or burn.
• Do not wrap the cord while the pads are attached to your skin.
• Wrap the cord after attaching the pads to the pad storage plate.
- Failure to do so may result in injury.
Prohibited!
• Do not use the device on areas close to the heart, on the face or head, in the mouth, genitals, or
where there is a skin disease.
- Doing so may cause an accident or health problems.
• Do not use the device while you are asleep.
- Doing so may cause an accident or injury, such as with the cord becoming entangled around
your neck. Furthermore, the pads may attach to another part of the body (near the heart, on the
face or head, in the mouth, genitals, or where there is a skin condition) and cause an accident or
health problems.

GB23
Guidance and manufacturer’s declaration – electromagnetic immunity
The model EW6011 is intended for use in the electromagnetic environment specified below. The customer or the user
of the model EW6011 should assure that it is used in such an environment
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, object and people.
Note:
UT
is the a.c. mains voltage prior to application of the test level
Immunity test
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
IEC 60601
test level
3 Vrms
150 kHz to 80 MHz
3 V/m
80 MHz to 2.5 GHz
Compliance
level
3 Vrms
3 V/m
Electromagnetic environment – guidance
Portable and mobile RF communications equipment should be
used no closer to any part of the model EW6011, including
cables, than the recommended separation distance calculated
from the equation applicable to the frequency of the transmitter.
Recommended separation distance
d = 1.2
√
—
P
d = 1.2
√
—
P
80 MHz to 800 MHz
d = 2.3
√
—
P
800 MHz to 2.5 GHz
where
P
is the maximum output power rating of the transmitter
in watts (W) according to the transmitter manufacturer and
d
is
the recommended separation distance in meters (m).
Field strength from fixed RF transmitters, as determined by an
electromagnetic site survey,ashould be less than the
compliance level in each frequency range.b
Interference may occur in the vicinity of equipment
marked with the followingsymbol:
Immunity test
Voltage dips, short
interruptions and
voltage variations on
power supply input lines
IEC 61000-4-11
Power frequency
(50/60Hz) magnetic field
IEC61000-4-8
IEC 60601
test level
<5%
UT
(>95% dip in
UT
)
for 0.5 cycle
40%
UT
(60% dip in
UT
)
for 5 cycles
70%
UT
(30% dip in
UT
)
for 25 cycles
<5%
UT
(>95% dip in
UT
)
for 5 cycle
3 A/m
Compliance
level
Not applicable
3 A/m
Electromagnetic environment -
guidance
Not applicable because the model
EW6011 is powered by built-in batteries.
Power frequency magnetic fields should
be at levels characteristics of a typical
location in a typical commercial or
hospital environment.
aField strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the model EW6011 is used exceeds the applicable RF
compliance level above, the model EW6011 should be observed to verify normal operation. If abnormal operation is
observed, additional measures may be necessary, such as reorienting or relocating the model EW6011.
bOver the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
GB22
The model EW6011 needs special precautions regarding EMC and needs to be used according to the following EMC
information.
Portable and mobile RF communications equipment can affect the model EW6011.
Accessories:
WARNING: The use of accessories other than those specified may results in increased emissions or decreased
immunity of the model EW6011.
WARNING: The model EW6011 should not be used adjacent to or stacked with other equipment. If adjacent or stacked
use is necessary, the model EW6011 should be observed to verify normal operation in the configuration in
which it will be used.
Note
The pads are packaged with the model EW6011 you purchased. Spare pads can be
obtained from specialist retailers, e.g. dispensing chemists and sanitary appliance
shops. Make sure you only buy original Panasonic accessories.
Guidance and manufacturer’s declaration – electromagnetic emissions
The model EW6011 is intended for use in the electromagnetic environment specified below. The customer or the
user of the model EW6011 should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC61000-3-2
Voltage fluctuations/flicker
emissions
IEC 61000-3-3
Compliance
Group 1
Class B
Not
applicable
Not
applicable
Electromagnetic environment - guidance
The model EW6011 uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are not likely to cause any
interference in nearby electronic equipment.
The model EW6011 is suitable use in all establishments, including
domestic establishments and those directly connected to the public low-
voltage power supply network that supplies building used for domestic
purposes.
The Harmonic emissions and the voltage fluctuations/flicker emissions
are not applicable because the model EW6011 is powered by built-in
batteries.
Guidance and manufacturer’s declaration – electromagnetic immunity
The model EW6011 is intended for use in the electromagnetic environment specified below. The customer or the
user of the model EW6011 should assure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD)
IEC 61000-4-2
Electrical fast transient/
burst
IEC 61000-4-4
Surge
IEC 61000-4-5
IEC 60601
test level
±6 kV contact
±8 kV air
±2 kV for power supply
lines
±1 kV for input/output
lines
±1 kV for differential
mode
±2 kV common mode
Compliance
level
±6 kV contact
±8 kV air
Not applicable
Not applicable
Electromagnetic environment -
guidance
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Not applicable because the model
EW6011 is powered by built-in
batteries and pad-cord is less than 3m.
Not applicable because the model
EW6011 is powered by built-in
batteries.
Accessories
Pads
Catalog No.
EW0603
EMC Information of the model EW6011

GB24
Recommended separation distance between portable and mobile RF communications equipment and the model EW6011
The model EW6011 is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the model EW6011 can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
model EW6011 as recommended below, according to the maximum output power of the communications equipment.
For transmitters rated at a maximum output power not listed above, the recommended separation distance
d
in
meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where
P
is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
Rated maximum output
power of transmitter
W
0.01
0.1
1
10
100
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d = 1.2
√
—
P
0.12
0.38
1.2
3.8
12
80 MHz to 800 MHz
d = 1.2
√
—
P
0.12
0.38
1.2
3.8
12
800 MHz to 2.5 GHz
d = 2.3
√
—
P
0.23
0.73
2.3
7.3
23
Information on Disposal for Users of Waste Electrical & Electronic Equipment
(private households)
This symbol on the products and/or accompanying documents means that used electrical
and electronic products should not be mixed with general household waste.
For proper treatment, recovery and recycling, please take these products to designated
collection points, where they will be accepted on a free of charge basis. Alternatively, in
some countries you may be able to return your products to your local retailer upon the
purchase of an equivalent new product.
Disposing of this product correctly will help to save valuable resources and prevent any potential
negative effects on human health and the environment which could otherwise arise from
inappropriate waste handling. Please contact your local authority for further details of your nearest
designated collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national
legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for
further information.
Information on Disposal in other Countries outside the European Union
This symbol is only valid in the European Union.
If you wish to discard this product, please contact your local authorities or dealer and ask for the
correct method of disposal.
Table of contents
Other Panasonic Fitness Equipment manuals
Popular Fitness Equipment manuals by other brands

SPORTSTECH
SPORTSTECH AH250 user manual

Hoist Fitness
Hoist Fitness ROC-IT RPL-5301-A owner's manual

York Fitness
York Fitness 56011 owner's manual

ICON Health & Fitness
ICON Health & Fitness WESLO Mini Stepper user manual

Railyard Fitness
Railyard Fitness Serius Strong Handles manual

KingsBox
KingsBox Mighty Yoke MX-40 II quick start guide

Keys Fitness
Keys Fitness StrenghtTrainer ST-ARM owner's manual

Inspire
Inspire ACB Assembly & operation manual

Northern Lights
Northern Lights NL 99WAYS Assembly instructions

CIRCLE FITNESS
CIRCLE FITNESS E7 owner's manual

Nexersys
Nexersys Fast Fists owner's manual

Octane Fitness
Octane Fitness Q47x Assembly instructions