2
TABLE OF CONTENTS PAGE PAGE
1 Safety Precautions -----------------------------------------------3
2 Specifications------------------------------------------------------5
2.1. WH-SDC07C3E5 WH-UD07CE5-A ------------------5
2.2. WH-SDC09C3E5 WH-UD09CE5-A ------------------8
2.3. WH-SDC12C6E5 WH-UD12CE5-A ----------------10
2.4. WH-SDC14C6E5 WH-UD14CE5-A ----------------12
2.5. WH-SDC16C6E5 WH-UD16CE5-A ----------------14
3Features------------------------------------------------------------16
4 Location of Controls and Components------------------17
4.1. Indoor Unit -------------------------------------------------17
4.2. Outdoor Unit-----------------------------------------------22
5 Dimensions -------------------------------------------------------23
5.1. Indoor Unit -------------------------------------------------23
5.2. Outdoor Unit-----------------------------------------------24
6 Refrigeration And Water Cycle Diagram ----------------26
7 Block Diagram ---------------------------------------------------28
7.1. WH-UD07CE5-A WH-UD09CE5-A -----------------28
7.2. WH-UD12CE5-A WH-UD14CE5-A
WH-UD16CE5-A -----------------------------------------29
8 Wiring Connection Diagram---------------------------------30
8.1. Indoor Unit -------------------------------------------------30
8.2. Outdoor Unit-----------------------------------------------32
9 Electronic Circuit Diagram-----------------------------------34
9.1. Indoor Unit -------------------------------------------------34
9.2. Outdoor Unit-----------------------------------------------36
10 Printed Circuit Board ------------------------------------------38
10.1. Indoor Unit -------------------------------------------------38
10.2. Outdoor Unit-----------------------------------------------40
11 Installation Instruction WH-UD07CE5-A WH-
UD09CE5-A--------------------------------------------------------44
11.1. Select The Best Location ------------------------------44
11.2. Indoor/Outdoor Unit Installation Diagram ----------44
11.3. Indoor Unit -------------------------------------------------45
11.4. Outdoor Unit-----------------------------------------------50
12 Installation Instruction WH-UD12CE5-A
WH-UD14CE5-A WH-UD16CE5-A -------------------------53
12.1. Select The Best Location ------------------------------53
12.2. Indoor/Outdoor Unit Installation Diagram ----------53
12.3. Indoor Unit -------------------------------------------------54
12.4. Outdoor Unit-----------------------------------------------59
13 Operation and Control-----------------------------------------62
13.1. Basic Function --------------------------------------------62
13.2. Water Pump -----------------------------------------------74
13.3. Pump Down Operation ---------------------------------74
13.4. Flow Switch------------------------------------------------74
13.5. Force Heater Mode Operation------------------------75
13.6. Indoor Unit Safety----------------------------------------75
13.7. Auto Restart Control-------------------------------------75
13.8. Indication Panel-------------------------------------------76
13.9. Indoor Back-Up Heater Control-----------------------76
13.10. Tank Booster Heater Control--------------------------77
13.11. Three Way Valve Control-------------------------------77
13.12. Sterillization Mode ---------------------------------------77
13.13. Quiet Operation-------------------------------------------78
13.14. Solar operation (Optional) -----------------------------78
13.15. External Room Thermostat Control (Optional)----82
13.16. Two ways valve control --------------------------------83
14 Protection Control----------------------------------------------84
14.1. Protection Control For All Operations -------------- 84
14.2. Protection Control For Heating Operation--------- 86
14.3. Protection Control For Cooling Operation--------- 86
15 Servicing Mode-------------------------------------------------- 87
15.1. Test Run---------------------------------------------------- 87
15.2. Proper Pump Down Procedure ---------------------- 87
15.3. How To Adjust Water Flow Rate--------------------- 87
15.4. Expansion Vessel Pre Pressure Checking-------- 87
16 Maintenance Guide -------------------------------------------- 88
17 Troubleshooting Guide--------------------------------------- 90
17.1. Refrigeration Cycle System--------------------------- 90
17.2. Relationship Between The Condition Of The
Air-to-Water Heatpump Indoor And Outdoor
Units And Pressure And Electric Current---------- 91
17.3. Breakdown Self Diagnosis Function---------------- 92
17.4. Error Codes Table --------------------------------------- 93
17.5. Self-diagnosis Method---------------------------------- 95
18 Disassembly and Assembly Instructions -------------128
18.1. To Remove Front Plate--------------------------------128
18.2. To Remove Cabinet------------------------------------128
18.3. To Remove Pressure Gauge ------------------------129
18.4. To Remove Control Panel ----------------------------129
18.5. To Remove RCCB--------------------------------------130
18.6. To Remove Transformer and Electronic
Controller Board-----------------------------------------130
18.7. To Remove Pressure Relief Valve, Flow
Switch, Water Pump and Bottle Complete -------131
19 Technical Data--------------------------------------------------133
19.1. Operation Characteristics ----------------------------133
19.2. Heating Capacity Table--------------------------------153
19.3. Cooling Capacity Table--------------------------------154
19.4. Hydraulic Pump Performance -----------------------155
20 Exploded View and Replacement Parts List----------156
20.1. WH-SDC07C3E5 WH-SDC09C3E5
WH-SDC12C6E5 WH-SDC14C6E5
WH-SDC16C6E5 ---------------------------------------156
20.2. WH-UD07CE5-A WH-UD09CE5-A----------------158
20.3. WH-UD12CE5-A WH-UD14CE5-A
WH-UD16CE5-A----------------------------------------162