Model Y393B31
SEISMIC ACCELEROMETER
Installation and Operating Manual
For assistance with the operation of this product,
contact the PCB Piezotronics, Inc.
Toll-free: 716-684-0001
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: [email protected]
Web: www.pcb.com
Manual 21354 Rev E
ECN 50523
Repair and Maintenance
PCB guarantees Total Customer Satisfaction through its
“Lifetime Warranty Plus” on all Platinum Stock Products
sold by PCB and through its limited warranties on all other
PCB Stock, Standard and Special products. Due to the
sophisticated nature of our sensors and associated
instrumentation, field servicing and repair is not
recommended and, if attempted, will void the factory
warranty.
Beyond routine calibration and battery replacements
where applicable, our products require no user
maintenance. Clean electrical connectors, housings, and
mounting surfaces with solutions and techniques that will
not harm the material of construction. Observe caution
when using liquids near devices that are not hermetically
sealed. Such devices should only be wiped with a
dampened cloth—never saturated or submerged.
In the event that equipment becomes damaged or ceases
to operate, our Application Engineers are here to support
your troubleshooting efforts 24 hours a day, 7 days a
week. Call or email with model and serial number as well
as a brief description of the problem.
Calibration
Routine calibration of sensors and associated
instrumentation is necessary to maintain measurement
accuracy. We recommend calibrating on an annual basis,
after exposure to any extreme environmental influence,
or prior to any critical test.
PCB Piezotronics is an ISO-9001 certified company whose
calibration services are accredited by A2LA to ISO/IEC
17025, with full traceability to SI through N.I.S.T. In
addition to our standard calibration services, we also offer
specialized tests, including: sensitivity at elevated or
cryogenic temperatures, phase response, extended high
or low frequency response, extended range, leak testing,
hydrostatic pressure testing, and others. For more
information, contact your local PCB Piezotronics
distributor, sales representative, or factory customer
service representative.
Returning Equipment
If factory repair is required, our representatives will
provide you with a Return Material Authorization (RMA)
number, which we use to reference any information you
have already provided and expedite the repair process.
This number should be clearly marked on the outside of
all returned package(s) and on any packing list(s)
accompanying the shipment.
Contact Information
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY14043 USA
Toll-free: (800) 828-8840
24-hour SensorLine: (716) 684-0001
General inquiries: in[email protected]
Repair inquiries: rma@pcb.com
For a complete list of distributors, global offices and sales
representatives, visit our website, www.pcb.com.
Safety Considerations
This product is intended for use by qualified personnel
who recognize shock hazards and are familiar with the
precautions required to avoid injury. While our equipment
is designed with user safety in mind, the protection
provided by the equipment may be impaired if equipment
is used in a manner not specified by this manual.
Discontinue use and contact our 24-Hour Sensorline if:
Assistance is needed to safely operate equipment
Damage is visible or suspected
Equipment fails or malfunctions
For complete equipment ratings, refer to the enclosed
specification sheet for your product.
Definition of Terms and Symbols
The following symbols may be used in this manual:
DANGER
Indicates an immediate hazardous
situation, which, if not avoided, may
result in death or serious injury.
Manual 21354 Rev E
ECN 50523
CAUTION
Refers to hazards that could damage
the instrument.
NOTE
Indicates tips, recommendations and
important information. The notes
simplify processes and contain
additional information on particular
operating steps.
The following symbols may be found on the equipment
described in this manual:
This symbol on the unit indicates that
high voltage may be present. Use
standard safety precautions to avoid
personal contact with this voltage.
This symbol on the unit indicates that
the user should refer to the operating
instructions located in the manual.
This symbol indicates safety, earth
ground.
Manual 21354 Rev E
ECN 50523
PCB工业监视和测量设备 - 中国RoHS2公布表
PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table
部件名称
有害物质
铅(Pb)
汞
(Hg)
镉
(Cd)
六价铬(Cr(VI))
多溴联苯 (PBB)
多溴二苯醚(PBDE)
住房
O
O
O
O
O
O
PCB板
X
O
O
O
O
O
电气连接器
O
O
O
O
O
O
压电晶体
X
O
O
O
O
O
环氧
O
O
O
O
O
O
铁氟龙
O
O
O
O
O
O
电子
O
O
O
O
O
O
厚膜基板
O
O
X
O
O
O
电线
O
O
O
O
O
O
电缆
X
O
O
O
O
O
塑料
O
O
O
O
O
O
焊接
X
O
O
O
O
O
铜合金/黄铜
X
O
O
O
O
O
本表格依据 SJ/T 11364 的规定编制。
O:表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量要求以下。
X:表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T 26572 规定的限量要求。
铅是欧洲RoHS指令2011/65/ EU附件三和附件四目前由于允许的豁免。
CHINA RoHS COMPLIANCE
Manual 21354 Rev E
ECN 50523
Component Name
Hazardous Substances
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Chromium VI
Compounds
(Cr(VI))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
Housing
O
O
O
O
O
O
PCB Board
X
O
O
O
O
O
Electrical Connectors
O
O
O
O
O
O
Piezoelectric Crystals
X
O
O
O
O
O
Epoxy
O
O
O
O
O
O
Teflon
O
O
O
O
O
O
Electronics
O
O
O
O
O
O
Thick Film Substrate
O
O
X
O
O
O
Wires
O
O
O
O
O
O
Cables
X
O
O
O
O
O
Plastic
O
O
O
O
O
O
Solder
X
O
O
O
O
O
Copper Alloy/Brass
X
O
O
O
O
O
This table is prepared in accordance with the provisions of SJ/T 11364.
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit
requirement of GB/T 26572.
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit
requirement of GB/T 26572.
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU.
Model Number
393B31 SEISMIC ICP® ACCELEROMETER Revision: G
ECN #: 47358
Performance ENGLISH SI
Sensitivity(± 5 %) 10.0 V/g 1.02 V/(m/s²) [2]
Measurement Range 0.5 g pk 4.9 m/s² pk
Frequency Range(± 5 %) 0.1 to 200 Hz 0.1 to 200 Hz
Frequency Range(± 10 %) 0.07 to 300 Hz 0.07 to 300 Hz
Resonant Frequency ≥700 Hz ≥700 Hz
Broadband Resolution(1 to 10,000 Hz) 0.000001 g rms 0.000009 m/s² rms [1]
Non-Linearity ≤1 % ≤1 % [3]
Transverse Sensitivity ≤5 % ≤5 %
Environmental
Overload Limit(Shock) ± 40 g pk ± 392 m/s² pk
Temperature Range -15 to +150 °F -26 to +65 °C
Temperature Response See Graph See Graph
Base Strain Sensitivity ≤0.0005 g/µε≤0.005 (m/s²)/µε[1]
Electrical
Excitation Voltage 24 to 28 VDC 24 to 28 VDC
Constant Current Excitation 2 to 10 mA 2 to 10 mA
Output Impedance ≤500 Ohm ≤500 Ohm
Output Bias Voltage 8 to 14 VDC 8 to 14 VDC
Discharge Time Constant ≥5 sec ≥5 sec
Settling Time(within 10% of bias) 60 sec 60 sec
Spectral Noise(1 Hz) 0.06 µg/√Hz 0.6 (µm/sec2)/√Hz [1]
Spectral Noise(10 Hz) 0.01 µg/√Hz 0.1 (µm/sec2)/√Hz [1]
Spectral Noise(100 Hz) 0.004 µg/√Hz 0.04 (µm/sec2)/√Hz [1]
Electrical Isolation(Case) ≥108Ohm ≥108Ohm
Physical
Sensing Element Ceramic Ceramic
Sensing Geometry Flexural Flexural
Housing Material Stainless Steel Stainless Steel
Sealing Hermetic Hermetic
Size (Diameter x Height) 2.25 in x 2.8 in 57.2 mm x 71.1 mm
Weight 22.4 oz 635 gm [1]
Electrical Connector 2-Pin MIL-C-5015 2-Pin MIL-C-5015
Electrical Connection Position Top Top
Mounting Thread 1/4-28 Female 1/4-28 Female
Mounting Torque 2 to 5 ft-lb 2.7 to 6.8 Nm
[4]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP®is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
NOTES:
[1] Typical
.
[2] Measured at 10 Hz, 0.1 grms
[3] Zer
o
-based, leas
t
-squares, straight line method
.
[4] See PCB Declaration of Conformance PS023 for details
.
SUPPLIED ACCESSORIES:
Model 081B20 Mounting Stud, with shoulder (1/4-28 to 1/4-28) (1)
Model ACS-11 NIST traceable amplitude and phase response from 0.5 Hz to upper 5%
frequency (1)
Model M081B20 Mounting Stud 1/4-28 to M6 X 0.75
Entered: LK Engineer: BAM Sales: KWW
A
pproved: BAM Spec Number:
Date: 10/19/2017 Date: 10/19/2017 Date: 10/19/201
7
Date: 10/19/201
7
2005
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]
MOUNTNG THRE AD SEE DR AWI NG
5-40 A
M3 X 0.50
B
10-32 C
M5 X 0.80 D
1/4-28
E
M6 X 1.00
F
BOLT THREAD SEE DRAWING
10-32 C
M5 X 0.80 D
1/4-28
E
M6 X 1.00
F
M8 X 1.25
F
1
1
2
2
3
3
4
4
A A
B B
CODE
IDENT. NO.
52681
DWG. NO.
SCALE: SHEET
DRAWN CHECKED ENGINEER
TITLE
UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
DIMENSIONS IN MILLIMETERS
[ IN BRACKETS ]
XX ±0.13
ANGLES 2 DEGREES
DIMENSIONS IN INCHES
DECIMALS XX ±.01
ANGLES 2 DEGREES
FILLETS AND RADII
.003 - .005
DECIMALS X ± 0.3
FILLETS AND RADII
0.07 - 0.13
INSTALLATION DRAWING
081-XXXX-90
1 OF 1NONE
FOR STANDARD
081 SERIES MOUNTING
XXX ±.005
NJF 05/03/23 JDM 05/03/23 MJN 05/03/23
3425 WALDEN AVE. DEPEW, NY 14043
(716) 684-0001 E-MAIL: sales@pcb.com
1"≤LENGTH < 1' = +1"/ - 0
1'≤LENGTH < 5' = +2"/ - 0
5'≤LENGTH < 100' = +6"/ - 0
100'≤LENGTH = +1'/ - 0
CABLE TOLERANCES IN ENGLISH CABLE TOLERANCES IN METRIC
2.54cm ≤LENGTH < 30.5cm = +2.54cm/ - 0
30.5cm ≤LENGTH < 1.5m = +5.1cm/ - 0
1.5m ≤LENGTH < 30.5m = +15.2cm/ - 0
30.5m ≤LENGTH = +30.5cm/ - 0
"A"
5-40
MOUNTING INSTRUCTIONS
(METRIC DIMENSIONS IN BRACKETS)
MOUNTING HOLE PREPARATION:
.101[2.57]
X .20[5.1]MIN.
5-40 UNC-2B
X .15[3.8]MIN.
4.) RECOMMENDED MOUNTING TORQUE,
4-5 INCH POUNDS
[45-55 NEWTON CENTIMETERS].
"B"
M3 X 0.50
MOUNTING INSTRUCTIONS
(ENGLISH DIMENSIONS IN BRACKETS)
MOUNTING HOLE PREPARATION:
2.5[.099]
X 4.6 [.18]MIN.
M3 X 0.50-6H
X 3.3[.13]MIN.
4.) RECOMMENDED MOUNTING TORQUE,
45-55 NEWTON CENTIMETERS
[4-5 INCH POUNDS].
"C"
10-32
MOUNTING INSTRUCTIONS
(METRIC DIMENSIONS IN BRACKETS)
4.) RECOMMENDED MOUNTING TORQUE,
10-20 INCH POUNDS
[113-225 NEWTON CENTIMETERS].
MOUNTING HOLE PREPARATION:
.159[4.04]
X .23[5.8]MIN.
10-32 UNF-2B
X .15[3.8]MIN.
"D"
M5 X 0.80
MOUNTING INSTRUCTIONS
(ENGLISH DIMENSIONS IN BRACKETS)
4.) RECOMMENDED MOUNTING TORQUE,
113-225 NEWTON CENTIMETERS
[10-20 INCH POUNDS].
MOUNTING HOLE PREPARATION:
4.22[.166]
X 7.62 [.300]MIN.
M5 X 0.8-6H
X 5.08[.200]MIN.
"E"
1/4-28
MOUNTING INSTRUCTIONS
(METRIC DIMENSIONS IN BRACKETS)
4.) RECOMMENDED MOUNTING TORQUE,
2-5 FOOT POUNDS
[3-7 NEWTON METERS].
MOUNTING HOLE PREPARATION:
.218[5.54]
X .300[7.62]MIN.
1/4-28 UNF-2B
X .200[5.08]MIN.
"F"
M6 X 0.75, M6 X 1.00, M8 X 1.25
MOUNTING INSTRUCTIONS
(ENGLISH DIMENSIONS IN BRACKETS)
4.) RECOMMENDED MOUNTING TORQUE,
3-7 NEWTON METERS [2-5 FT POUNDS].
M8 X 1.25
MOUNTING HOLE PREPARATION:
6.75[.266]
X 8.64 [.340]MIN.
M8 X 1.25-6H
X 5.00[.197]MIN.
M6 X 0.75
MOUNTING HOLE PREPARATION:
5.31[.209]
X 7.62 [.300]MIN.
M6 X 0.75-6H
X 5.08[.200]MIN.
M6 X 1.0
MOUNTING HOLE PREPARATION:
5.05[.199]
X 8.10 [.320]MIN.
M6X 1.0-6H
X 6.35[.250]MIN.
"B"
"C"
"G"
MOUNTING INSTRUCTIONS
FOR SPECIAL THREAD LENGTHS
(METRIC DIMENSIONS IN BRACKETS)
THREAD DEPTH : B= X + 1 THREAD PITCH
DRILL DEPTH : C= B + 3 THREAD PITCH
SEE A-F FOR APPROPRIATE DRILL AND TAP
THREAD PITCH= 1/TPI [P]
3.) FOR BEST RESULTS, PLACE A THIN LAYER OF SILICONE GREASE (OR EQUIVALENT) ON INTERFACE PRIOR
TO MOUNTING.
MOUNTING SURFACE SHOULD BE FLAT TO WITHIN .001(0.03) TIR OVER DIM 'A' WITH A OR BETTER FINISH FOR BEST RESULTS.
DRILL PERPENDICULAR TO MOUNTING SURFACE TO WITHIN 1.
SENSOR
SENSOR
"THRU-BOLT"
"THRU-BOLT" STUD MOUNT
INTEGRAL STUD MOUNT
SENSOR
THREAD
MOUNTING
THREAD
SENSOR
THREAD
MOUNTING
THREAD
STANDARD STUD MOUNT
"X"
"X"
SENSOR THREAD
"X"
1111
1
1
1
1
2222
2
2
2
MOUNTING HOLE PREPARATION:
DRILL DIA.
X "C"MIN.
TAP
X "B"MIN.
1
"A"
"A"
"A"
"P"
1 THREAD PITCH
SHOWN
"X"
SENSOR
INTEGRAL
MOUNTING
STUD
63[1.61]
REVISIONS
REV DESCRIPTION DIN
R CHANGED "B" HOLE TOLERANCE 53828
2
1
MOUNTING THREAD SEE DRAWING
5-40 A
M3 X 0.50 B
10-32 C
M5 X 0.80 D
1/4-28 E
M6 X 1.00 F
081-XXXX-90
PCB Piezotronics Inc. claims proprietary rights in
the information disclosed hereon. Neither it nor any
reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.

Other PCB Piezotronics Measuring Instrument manuals

PCB Piezotronics 353B51 User manual

PCB Piezotronics

PCB Piezotronics 353B51 User manual

PCB Piezotronics IMI SENSORS 627A61 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 627A61 User manual

PCB Piezotronics IMI SENSORS 627A01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 627A01 User manual

PCB Piezotronics 357B83 User manual

PCB Piezotronics

PCB Piezotronics 357B83 User manual

PCB Piezotronics 357B14 User manual

PCB Piezotronics

PCB Piezotronics 357B14 User manual

PCB Piezotronics HT352A25/NC User manual

PCB Piezotronics

PCB Piezotronics HT352A25/NC User manual

PCB Piezotronics TLD339A36 User manual

PCB Piezotronics

PCB Piezotronics TLD339A36 User manual

PCB Piezotronics A320C15 User manual

PCB Piezotronics

PCB Piezotronics A320C15 User manual

PCB Piezotronics 356A14 User manual

PCB Piezotronics

PCB Piezotronics 356A14 User manual

PCB Piezotronics ICP 625B12 User manual

PCB Piezotronics

PCB Piezotronics ICP 625B12 User manual

PCB Piezotronics IMI SENSORS 601A01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 601A01 User manual

PCB Piezotronics 352C41 User manual

PCB Piezotronics

PCB Piezotronics 352C41 User manual

PCB Piezotronics 3501B122KG User manual

PCB Piezotronics

PCB Piezotronics 3501B122KG User manual

PCB Piezotronics 357B40 User manual

PCB Piezotronics

PCB Piezotronics 357B40 User manual

PCB Piezotronics 356A22/NC User manual

PCB Piezotronics

PCB Piezotronics 356A22/NC User manual

PCB Piezotronics 052M94A User manual

PCB Piezotronics

PCB Piezotronics 052M94A User manual

PCB Piezotronics 3503A112KG User manual

PCB Piezotronics

PCB Piezotronics 3503A112KG User manual

PCB Piezotronics IMI SENSORS 601A11 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 601A11 User manual

PCB Piezotronics IMI SENSORS ICP 66212APZ1 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP 66212APZ1 User manual

PCB Piezotronics IMI SENSORS ICP M603C91 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP M603C91 User manual

PCB Piezotronics 356B41/NC User manual

PCB Piezotronics

PCB Piezotronics 356B41/NC User manual

PCB Piezotronics SM101A06 User manual

PCB Piezotronics

PCB Piezotronics SM101A06 User manual

PCB Piezotronics IMI SENSORS TOM607A01 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS TOM607A01 User manual

PCB Piezotronics IMI SENSORS 66332APZ1 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 66332APZ1 User manual

Popular Measuring Instrument manuals by other brands

Dinel ULM-55N instructions

Dinel

Dinel ULM-55N instructions

NLS XL-1 instructions

NLS

NLS XL-1 instructions

HBK PAD4001A operating manual

HBK

HBK PAD4001A operating manual

Neopost ij25 user guide

Neopost

Neopost ij25 user guide

UNAOHM EP2500 manual

UNAOHM

UNAOHM EP2500 manual

ABB RELION 650 SERIES Operation manual

ABB

ABB RELION 650 SERIES Operation manual

LI-COR LI-840/A instruction manual

LI-COR

LI-COR LI-840/A instruction manual

FISCHER DA01 VUW ATEX operating manual

FISCHER

FISCHER DA01 VUW ATEX operating manual

Teledyne T360 Operation manual

Teledyne

Teledyne T360 Operation manual

TRIMALCO APOLLO 210 instructions

TRIMALCO

TRIMALCO APOLLO 210 instructions

HP 3458A Technical manual

HP

HP 3458A Technical manual

Leica GS50 user manual

Leica

Leica GS50 user manual

GREISINGER GMH 3156 user manual

GREISINGER

GREISINGER GMH 3156 user manual

XFtp TR-3 Operation manual

XFtp

XFtp TR-3 Operation manual

BEKA BA554E manual

BEKA

BEKA BA554E manual

General TOOLSMART TS02 user manual

General

General TOOLSMART TS02 user manual

Honeywell SmartLine SLG 700 user manual

Honeywell

Honeywell SmartLine SLG 700 user manual

Seitron CHEMIST 600 Operation and maintenance manual

Seitron

Seitron CHEMIST 600 Operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.