Specification
Supply Pressure
Maximum 18.0 bar (260 psi / 1800 kpa)
Recommended clean filter air or Nitrogen
Supply Connection
Rp ¼ (Optional NPT ¼ Female)
Body Construction
Die cast aluminium with steel operating lever and impact absorbing bumper
Tyre Pressure Range
0,3 – 17,2 bar / 4 – 250 psi / 30 – 1720 kPa
Resolution 0,01 bar / 0,1 psi / 1 kPa
Other calibration options possible
Gauge
LCD with continuous backlight
Powered by replaceable 2 x AAA batteries
Accuracy to EN12645:2014
Temperature range: -15 C to +55 C
CE approved, tested to relevant EMC standards
Complete with certificate of Calibration
Operation
Switch on/off – automatic with tyre pressure > minimum range or press calibration
button. Automatically turned off after 25 seconds from last use.
To Inflate
After placing connector square onto the valve, fully depress lever for an appropriate
period and release lever. Observe the tyre pressure.
To Deflate
Depress lever halfway (until air can be heard escaping) for an appropriate period.
Then release lever to display new pressure.
Unit of Calibration change
Press and hold Pu button for 2 seconds, to increment to next pressure unit.
The selected unit is remembered at next power up.
Replace 2 x AAA batteries when battery indication symbol shows Empty.
Unscrew end cover, remove old batteries and replace with new batteries, screw in end
plug until display illuminates & then tighten ¼ turn only.
Safety precautions
Never exceed Maximum Pressure of the tyre
Observe all the necessary safety regulation in place at point of use.
•Ensuring safe working with compressed air.
•Tyre fitment and inflation of Commercial Tyres or split rim wheels- the tyre
inflator should have a minimum hose length of 1.8m (6’) and a clip on
connector.
Important
No responsibility is accepted for incorrect use of this product.