5.Connect power line into “1” and “2” in the diagram.
6.Electrify it, the power voltage must be in accord with the voltage indicated.
7.Fix the lamp in the installation location with screw.
1. After installation, before electrifying it, turn the time knob(TIME)
clockwise to the minimum and turn the photocell knob (LUX))
clockwise to the maximum(☼), turn the sensitivity knob(SENS)
clockwise to the maximum.(like right diagram)
2. Electrify it. After 5 seconds, the lamp should be on.
3. 5-10 seconds later after the lamp turn off (no sense condition),
make it sense, the lamp should be on, under no sense signal
condition, the lamp should turn off within 5sec~10sec.
4. If all are normal, turn the time setting knob to confirm the light time
you want; turn the photocell knob to change the light-control; and turn
the sensitivity knob to adjust the detection range.
-
+
SENS
-
LUX
+
TIME
1. Avoid installing the product in the locations where the sunlight irradiate or air current and
temperature change obviously;
2. Avoid touching the detection window with sharp and stiff things or coarse pollutants;
3. When the lamp is off and then again on, you should adjust the angle between the lamp head and
the sensor, and turn the sensitivity knob (SENS) properly to solve the problem.
5. Caution: the product can continuously sense as long as signal has made it work: If the product is
tested in the daytime (the light set is less than 10lux), with opaque cover the lens, after the unit works,
take off the opaque and let it receive natural light, here it can sense continually. After the load stop to
work, it can work only when the light-control is less than 10lux.
12
74mm
ATTENTION: When use this product, please adjust the sensitivity to an appropriate position you need,
please do not adjust the sensitivity to maximum, to avoid the product does not work normally caused
by wrong motion.Because the sensitivity is too high easily detect the wrong motion by wind blowing
leaves & curtains, small animals, and the wrong motion by interference of power grid & electrical
equipment. All those lead the product does not work normally !
When the product does not work normally, please try to lower the sensitivity appropriately, and then
test it.
Infrared Sensor Lamp
PD-PIR69 instruction
www.pdlux.com Tel: 86-574-83008608
TEST
CAUTIONS
Solutions of prevent the power network pulse interference the products:
Due to the difference of regional interference power network, the pulse of interference is
uncertain,so the user are not suggested to adjust the sensitive to the maxium when
using.Suggestion:Please install and adjust the sensitive in the appropriate distance
using,do not set the maxium sensitivity to prevent misoperation.