DESCRIPTION
The E507S-LS thermostat is designed for controlling heat-tracing
systems in hazardous locations. The E507S-LS can be used to
control heat-tracing circuits in a pipe-sensing mode (see Figure 1
on back page), to indicate low-temperature (see Figure 2) or high-
temperature (see Figure 3) alarm conditions, or to control the coil
on a contactor (see Figure 4).
APPROVALS
SPECIFICATIONS
Enclosure NEMA 4, 7, 9, lacquer-coated cast-aluminum
housing, stainless-steel hardware
Entries One 3/4 in. NPT conduit hub
Set point range 25°F to 325°F (–4°C to 163°C)
Sensor exposure
limits
–40°F to 420°F (–40°C to 215°C)
Housing exposure
limits
–40°F to 140°F (–40°C to 60°C)
Switch SPDT
Electrical rating 22 A at 125/250/480 Vac
Accuracy ±6°F (±3.3°C)
Deadband 2°F to 12°F (1.1°C to 6.7°C) above actuation
temperature
Set point
repeatability
±3°F (±1.7°C)
Sensor type Fluid-filled (silicone) bulb and 9 ft (2.7 m)
capillary
Sensor material 300 series stainless steel
Connection
terminals
Screw terminals, 10–14 AWG (2–5 mm2)
Class I, Div. 1 and 2, Groups B, C, D
Class II, Div. 1 and 2, Groups E, F, G
Class III
Hazardous locations
This component is an electrical device. It must be installed
correctly to ensure proper operation and to prevent shock or
fire. Read these important warnings and carefully follow all the
installation instructions.
Component approvals and performance are based on the use of
specified parts only. Do not use substitute parts or vinyl electrical
tape to make connections.
WARNING:
4.0 in. (102 mm)
4.5 in. (114 mm) Ø.28 in. (7 mm)
mounting hole
(4X)
4.5 in.
(114 mm)
6.6 in.
(168 mm)
4.0 in.
(102 mm)
8.0 in.
(202 mm)
Adjusting knob
Removable knob cover
4.0 in. (102 mm)
1.2 in. (30 mm)
2.0 in.
(50 mm)
3⁄4 in. NPT conduit entry
0.3 in. (9 mm)
Terminal
block
2 / 2THERMAL MANAGEMENT SOLUTIONS EN-DigiTraceE507SLS-IM-H5691301/13
WWW.THERMAL.PENTAIR.COM
© 2001-2013 Pentair. PN 137863
NORTH AMERICA
Tel: +1.800.545.6258
Fax: +1.800.527.5703
Tel: +1.650.216.1526
Fax: +1.650.474.7711
thermal.info@pentair.com
EUROPE, MIDDLE EAST, AFRICA
Tel: +32.16.213.511
Fax: +32.16.213.603
thermal.info@pentair.com
ASIA PACIFIC
Tel: +86.21.2412.1688
Fax: +86.21.5426.2917
cn.thermal.info@pentair.com
LATIN AMERICA
Tel: +55.11.2588.1400
Fax: +55.11.2588.1410
thermal.info@pentair.com
Pentair and DigiTrace are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the
right to change specifications without prior notice.
Figure 4. Contactor control
Figure 1. Pipe-sensing
CNO NC
For switching heat-tracing loads greater than 22 A
or switching multiple heat-tracing circuits.
Ø
G
G
N
ØØ
Heating
Cable
Power
connection
Thermostat bulb
(see "Positioning"
instructions above
for mounting details)
Braid
Control
thermostat
Control
thermostat
GFEPD
C
C
NONC
NONC
Thermostat bulb
(see "Positioning"
instructions above
for mounting details)
or 208-V or 240-V supply – 240-V heater
120-V supply – 120-V heater
277-V supply – 240-V heater
ØC
G
C
NANBNCØB
ØA
120-V or
277-V
coil
Braid
120- V supply – 120-V heater or
277-V supply – 240-V heater
GFEPD
Figure 2. Low-temperature alarm
CNO NC
Ø
GN
ØØ
Alarm
Thermostat bulb
(see "Positioning"
instructions above
for mounting details)
Control
thermostat
GFEPD
or 208-V or 240-V supply
120-V supply – 120-V heater
277-V supply – 240-V heater
Figure 3. High-temperature alarm
CNO NC
Ø
GN
ØØ
Alarm
Thermostat bulb
(see "Positioning"
instructions above
for mounting details)
Control
thermostat
GFEPD
or 208-V or 240-V supply
120-V supply – 120-V heater
277-V supply – 240-V heater
Heating
cable C
Heating
cable B
Heating
cable A
WIRING
INSTALLING THE THERMOSTAT
1. Verify that the thermostat is
suitable for the area where it is to
be installed.
2. Check the line voltage and the
heat-tracing load to ensure that
the thermostat ratings are not
exceeded.
3. Mount the unit using unistrut or the Raychem universal
mounting bracket (UMB-263757) in a position that prevents
condensation from draining into the enclosure from the
connecting conduit (see diagram above).
POSITIONING THE SENSOR BULB
4. Position the bulb in the
lower quadrant of the pipe
as shown in the diagrams
to the left. Place the bulb
at least three feet from
pipe supports, valves, or
other heat sinks; protect
the capillary from kinks or
bends less than 1⁄2 inch in
radius.
5. Tape the bulb firmly to the pipe with AT-180 aluminum tape,
making sure there is no air space between the bulb and pipe.
Do not overlap the bulb and heating cable with the same piece
of AT-180 tape.
6. For metal-tank-wall sensing, use the BCK-35 bulb clamp
(purchased separately) and install the clamp per the
instructions provided. Make sure there is no air space between
the tank wall and the bulb.
For installation on plastic tanks, contact Pentair Thermal
Management at (800) 545-6258.
SETTING THE THERMOSTAT
7. Set the thermostat dial to the desired temperature, then finish
wiring.
8. Complete insulating. Do not turn the system on until the bulb is
covered with thermal insulation.
9. Fill the piping or tank. Once the thermostat has begun to cycle,
check the fluid temperature with an immersed thermostat
(best for plastic systems) or an accurate temperature indicator.
Adjust the dial setting if necessary.
Conduit
drain
90 Heating cable
Control thermostat bulb
AT-180 tape
AT-180 tape
Heating cable
Control thermostat bulb
Double traced
Single traced

This manual suits for next models

1

Other Pentair Thermostat manuals

Pentair Raychem SENZ User manual

Pentair

Pentair Raychem SENZ User manual

Pentair Raychem QuickStat-TC User manual

Pentair

Pentair Raychem QuickStat-TC User manual

Pentair Raychem Green Leaf User manual

Pentair

Pentair Raychem Green Leaf User manual

Pentair RAYCHEM RAYSTAT-CONTROL-10 User manual

Pentair

Pentair RAYCHEM RAYSTAT-CONTROL-10 User manual

Pentair NRG-DM User manual

Pentair

Pentair NRG-DM User manual

Pentair Raychem Green Leaf User manual

Pentair

Pentair Raychem Green Leaf User manual

Pentair NRG-Temp User manual

Pentair

Pentair NRG-Temp User manual

Pentair QuickStat-TC User manual

Pentair

Pentair QuickStat-TC User manual

Pentair Raychem User manual

Pentair

Pentair Raychem User manual

Pentair Nuheat Signature User manual

Pentair

Pentair Nuheat Signature User manual

Pentair NRG-Temp User manual

Pentair

Pentair NRG-Temp User manual

Pentair NRG-Temp User manual

Pentair

Pentair NRG-Temp User manual

Pentair HLTSTAT10C User manual

Pentair

Pentair HLTSTAT10C User manual

Pentair DigiTrace AMC-1H User manual

Pentair

Pentair DigiTrace AMC-1H User manual

Pentair Nuheat element User manual

Pentair

Pentair Nuheat element User manual

Pentair Digitrace E507S-2LS-2 User manual

Pentair

Pentair Digitrace E507S-2LS-2 User manual

Pentair DigiTrace AMC-2B-2 User manual

Pentair

Pentair DigiTrace AMC-2B-2 User manual

Pentair NRG-DM User manual

Pentair

Pentair NRG-DM User manual

Pentair RAYCHEM AMC-1A User manual

Pentair

Pentair RAYCHEM AMC-1A User manual

Pentair Raychem QuickStat-TC User manual

Pentair

Pentair Raychem QuickStat-TC User manual

Pentair RAYSTAT-EX-03 User manual

Pentair

Pentair RAYSTAT-EX-03 User manual

Popular Thermostat manuals by other brands

Honeywell 69-1490 owner's guide

Honeywell

Honeywell 69-1490 owner's guide

American Standard Link UX360 user guide

American Standard

American Standard Link UX360 user guide

iSNATCH HeyThermo 49.6830.33 manual

iSNATCH

iSNATCH HeyThermo 49.6830.33 manual

Frico TAP16R quick guide

Frico

Frico TAP16R quick guide

Regin REGIO RU-DFO manual

Regin

Regin REGIO RU-DFO manual

Xiamen HY609WIFI-WE user manual

Xiamen

Xiamen HY609WIFI-WE user manual

Gingerway GW-4361 instruction manual

Gingerway

Gingerway GW-4361 instruction manual

AMATI HY08 Series user manual

AMATI

AMATI HY08 Series user manual

Carrier Edge TP-PRH owner's manual

Carrier

Carrier Edge TP-PRH owner's manual

Perry Electric MODULE Series quick start guide

Perry Electric

Perry Electric MODULE Series quick start guide

Salus ERT30RT instruction manual

Salus

Salus ERT30RT instruction manual

Honeywell Home The Digital Round T8775A installation instructions

Honeywell Home

Honeywell Home The Digital Round T8775A installation instructions

Vive TP-N-631W Operation manual

Vive

Vive TP-N-631W Operation manual

ritetemp 6005 install guide

ritetemp

ritetemp 6005 install guide

Honeywell Aube Technologies TH113-A installation instructions

Honeywell

Honeywell Aube Technologies TH113-A installation instructions

AirPatrol Lite Nordic quick start guide

AirPatrol Lite

AirPatrol Lite Nordic quick start guide

Siemens RDG100T operating instructions

Siemens

Siemens RDG100T operating instructions

Regin DTTH Instruction

Regin

Regin DTTH Instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.