lexible high pressure tubing compatible with the fluid
should be used to connect the inlet/outlet ports. Tubing
should be 1/2" [13 mm] I.D. and at least an 18 in. [46 cm]
length is suggested to minimize stress on the fitting/ports
and reduce noise. Allow for the shortest possible tubing
route and avoid sharp bends that may kink over time.
Restrictions on the inlet may cause vacuum levels to
reach the fluid vapor pressure, causing cavitation,
degassing, vapor lock, noise, and a loss in performance.
Inlet pressure must not exceed 30 psi [2.1 bar] maximum.
SHURflo does not recommend the use of metal fittings or
rigid pipe to plumb the inlet/outlet ports. Standard plastic
male and female-threaded fittings can be acquired at
commercial plumbing supply stores. SHURflo also distrib-
utes swivel barb fittings and special fittings through its
dealers.
1/2" Female NPT models: In some cases, the ports may require
a suitable thread sealer applied sparingly. DO NOT over-tighten,
max. torque 3.7 ft. lbs. [45 in. lbs. (5 Nm)].
1/2" Male-threaded models are intended to be used with SHURflo
swivel barb fittings which seal with an internal taper when hand-
tightened. Standard 1/2" NPT fittings may be used when tightened
to a maximum torque of 3.7 ft.lbs [45 in.lbs (5 Nm)].
Sealers and Teflon tape may act as a lubricant, causing cracked
housings or stripped threads due to over-tightening. Care should
be used when applying sealers. Sealers may enter the pump,
inhibiting valve action, causing no prime or no shut-off. ailures
due to foreign debris are not covered under warranty.
Installation of a 50-mesh strainer is recommended to prevent for-
eign debris from entering the pump.
If a check valve is installed in the plumbing, it must have a crack-
ing pressure of no more than 2 psi (.14 bar).
The pressure switch reacts to outlet pressure and inter-
rupts power at the preset shut-off pressure indicated on
the pump label. When outlet pressure drops below a pre-
determined limit (typically 15-20 psi [1-1.4 bar] less than
the shut-off pressure), the switch will close and the pump
will operate until the shut-off (high) pressure is achieved.
The shut-off pressure is set to factory calibrated stan-
dards. See the motor label for specific pump specifica-
tions.
Improper adjustment of the pressure switch may cause
severe overload or premature failure. ailures due to
improper adjustment of the pressure switch will not be
covered under the limited warranty.
If the plumbing is restrictive or the flow rate is very low, the
pump may re-pressurize the outlet faster than the fluid is
being released, causing rapid cycling (ON/O within 2
seconds). If the pump is subjected to rapid cycling during
normal operation, damage may occur. Applications which
exhibit rapid cycling should have restrictions in the outlet
minimized.
The 5059 series pumps are self priming. Horizontal and
vertical prime vary depending on the fluid viscosity and
pump configuration.
The pump should be located in an area that is dry and pro-
vides adequate ventilation. If mounted within an enclo-
sure, provisions to cool the motor may be necessary.
Heat sinks, which attach to the motor, are available from
SHURflo if increased heat dissipation is necessary.
DO NOT locate the motor near low temperature plastics or
combustible materials. The surface temperature of the
motor may exceed 250° [120°C].
The pump may be mounted in any position. However, if
mounting the pump vertically, the pump head should be in
the down position so that in the event of a leak, fluid will
not enter the motor.
Secure the rubber feet with #8 hardware. DO NOT com-
press the feet: doing so will reduce their ability to isolate
vibration/noise.
2
Pressure Switch Operation
Mounting
Plumbing
Bypass Operation
A bypass pump may be used for applications that normal-
ly induce frequent start/stop of the motor, and thereby cre-
ate a potential for overheating. Models equipped with an
internal bypass are designed to pump at high pressure
while at low flow rates.
Bypass models equipped with a switch may operate for
several seconds even though the outlet side has been
closed off. Contact SHURflo for information regarding
bypass pumps.