Pepperl+Fuchs VisuNet GXP RM-GXP1100-22F User manual

VisuNet GXP
RM-GXP1100-22F
RM-GXP1200-22F
PC-GXP1100-22F
PC-GXP1200-22F
Manual

With regard to the supply of products, the current issue of the following document is applicable: The
General Terms of Delivery for Products and Services of the Electrical ndustry, published by the Central
Association of the Electrical ndustry (Zentralverband Elektrotechnik und Elektroindustrie (ZVE ) e.V.)
in its most recent version as well as the supplementary clause: "Expanded reservation of proprietor-
ship"
Worldwide
Pepperl+Fuchs Group
Lilienthalstr. 200
68307 Mannheim
Germany
Phone: +49 621 776 - 0
E-mail: inf[email protected]hs.com
North American eadquarters
Pepperl+Fuchs nc.
1600 Enterprise Parkway
Twinsburg, Ohio 44087
USA
Phone: +1 330 425-3555
E-mail: [email protected]
Asia eadquarters
Pepperl+Fuchs Pte. Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Phone: +65 6779-9091
E-mail: [email protected]-fuchs.com
https://www.pepperl-fuchs.com

3
VisuNet GXP
Contents
2020-09
1 Introduction................................................................................................................ 4
1.1 Content of this Document............................................................................. 4
1.2 Target Group, Personnel ............................................................................... 4
1.3 Symbols Used ................................................................................................ 5
2 Product Description .................................................................................................. 6
2.1 Overview......................................................................................................... 6
2.2 Technical Specifications ............................................................................... 9
2.3 Dimensions................................................................................................... 13
3 Mechanical Installation ........................................................................................... 16
3.1 Unpacking .................................................................................................... 16
3.2 Electrical Installation................................................................................... 18
3.3 System Installation ...................................................................................... 19
3.3.1 General nstallation nformation ....................................................... 19
3.3.2 Preparing for Pedestal nstallation.................................................... 20
3.3.3 Mounting the Housing onto the Pedestal ......................................... 23
3.3.4 nstalling Cables in the Pedestal ...................................................... 29
3.3.5 Grounding the Housing to the Pedestal ........................................... 33
3.3.6 nstallation of the Ferrite Ring .......................................................... 36
3.3.7 Wall Mount nstallation ..................................................................... 37
3.3.8 Mounting the Keyboard.................................................................... 39
3.3.9 Mounting the DM-* Barcode Reader Holder Bracket ...................... 41
3.3.10 Cable nstallation for DM-* Readers and Base Stations .................. 47
3.3.11 Cable nstallation for PSCAN-D-* Handheld Readers ...................... 50
3.3.12 Closing the Housing......................................................................... 53
3.3.13 Dismounting the Display Unit ........................................................... 57
3.3.14 Panel Mount nstallation................................................................... 62
4 Appendix .................................................................................................................. 67
4.1 Accessories.................................................................................................. 67

2020-09
4
VisuNet GXP
ntroduction
1 Introduction
1.1 Content of this Document
This document contains information that you need in order to use your product throughout the
applicable stages of the product life cycle. These can include the following:
•Product identification
•Delivery, transport, and storage
•Mounting and installation
•Commissioning and operation
•Maintenance and repair
•Troubleshooting
•Dismounting
•Disposal
The documentation consists of the following parts:
•Present document
•nstruction manual
•Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
•EU-type examination certificate
•EU declaration of conformity
•Attestation of conformity
•Certificates
•Control drawings
•Additional documents
1.2 Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismount-
ing lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, com-
missioning, operation, maintenance, and dismounting of the product. The personnel must have
read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
Note
This document does not substitute the instruction manual.
Note
For full information on the product, refer to the instruction manual and further documentation on
the nternet at www.pepperl-fuchs.com.

VisuNet GXP
ntroduction
2020-09
5
1.3 Symbols Used
This document contains symbols for the identification of warning messages and of informative
messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. t is mandatory
that you observe these warning messages for your personal safety and in order to avoid prop-
erty damage.
Depending on the risk level, the warning messages are displayed in descending order as fol-
lows:
Informative Symbols
Action
This symbol indicates a paragraph with instructions. You are prompted to perform an action or
a sequence of actions.
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in
their complete failure.
Note
This symbol brings important information to your attention.

2020-09
6
VisuNet GXP
Product Description
2 Product Description
2.1 Overview
Pepperl+Fuchs VisuNet GXP workstations are ATEX/ ECEx certified, UL Listed PCs or thin-cli-
ent based remote monitors intended for use in potentially explosive atmospheres such as
Zones 1/21 and 2/22, Class / , Division 2, and Class . Two display sizes are available—19
inch and 21.5 inch. This manual covers the 21.5 inch models. For information on the 19 inch
models, see the product pages at www.pepperl-fuchs.com.
The modular VisuNet GXP consists of three core field-replaceable devices:
•DPU1100-* and DPU1200-* display units with optional 10-finger multi-touch sensors. The
displays and touch tensors are optically bonded with the hardened front glass.
•Computing units:
•TCU1100-* and TCU1200-* thin client units that run the latest Pepperl+Fuchs RM
Shell firmware. Using standard Ethernet technology, they allow connection to host
systems in the non-Ex area.
•PCU1100-* and PCU1200-* PC units run an open Microsoft® Windows® operating
system that allows installation of any software, including SCADA packages.
•PSU1100-* and PSU1200-* power supply units provide the above devices with 24 V DC
power. They are available as DC or wide-range AC versions.
VisuNet GXP components come preassembled in a panel. As a standard mounting option, a
bezel is available that allows the panel to be mounted into a system housing or cabinet (mount-
ing kit required). The panel can also be flush mounted into a cabinet from behind with addi-
tional mounting brackets.

VisuNet GXP
Product Description
2020-09
7
Figure 2.1 VisuNet GXP panel components
The VisuNet GXP system can also be ordered pre-mounted in an AG-XX00 housing, ready for
pedestal or wall mounting.
VisuNet GXP Panel Components
1Bezel for housing and panel mounting
2Computing unit (TCU or PCU): processor, SSD and memory, Ex circuits,
interface modules
3Power supply unit: DC or AC option, backpacked (panel-mount) or stand-
alone (in system enclosure)
4Display unit: display, touch screen, hardened front glass
12
3
4

2020-09
8
VisuNet GXP
Product Description
Figure 2.2 VisuNet GXP workstation mounted in an AG-XX00 housing on a PEDESTAL-XX00-*
pedestal with optional EXTA2-* keyboard/mouse (ordered separately)
VisuNet GXP Pedestal Mounted with Keyboard/Mouse
Note
For a description of the product model nomenclature, see the VisuNet GXP PC or VisuNet GXP
RM product datasheets at www.pepperl-fuchs.com.
For more mounting options and information, see the VisuNet Mounting Options datasheet.

VisuNet GXP
Product Description
2020-09
9
2.2 Technical Specifications
Technical Data RM-GXP*
Technical Data PC-GXP*
Technical Data RM-GXP* and PC-GXP*
ardware
Processor ntel® Atom™ Apollo Lake E3930
RAM 4 GB
Mass storage 32 GByte industrial grade MLC SSD
Software
Operating system VisuNet RM Shell 5.x (based on Microsoft®
Windows 10 oT Enterprise 2019 LTSC (x64))
ardware
Processor ntel® Atom™ Atom Apollo Lake E3940
RAM 8 GB
Mass storage 240 GByte industrial grade SSD
Optional: 480 GByte SSD
Software
Operating system Microsoft® Windows 10 oT Enterprise 2019
LTSC (x64)
Supply
Power consumption
AC 115/230 V AC, 0.4 ... 0.7 A, 50/60 Hz
DC 18 ... 36 V DC , 1.5 ... 3 A
Indicators/operating means
Display
Type Liquid Crystal Display (LCD) with LED back-
light
Screen diagonal 54.61 cm (21.5 inch)
Resolution 1920 x 1080 pixels (Full HD)
Aspect ratio 16:9
Color depth 24 bit (16.7 M) color
Contrast 5000:1 (typically)
Brightness 300 cd/m
2
Reading angle 175° in all directions
Life span back lamp life: 50.000 hrs typical half life , at
25 °C (77 °F)
nput devices
Touchscreen optional: projective capacitive; 10 finger multi-
touch, glove friendly
Keyboard Foil keyboard with different pointing device
options available (see EXTA2 datasheet)

2020-09
10
VisuNet GXP
Product Description
Interface
nterface type Standard:
1 x Ethernet 100/1000BASE-TX (Ex e) or
1 x fiber optic 1000BASE-SX (Multimode) or
1 x fiber optic 1000BASE-LX (Singlemode),
1 x USB 2.0 (Ex e),
2 x USB 1.1 (Ex i; intended for Pepperl+Fuchs
keyboard and mouse),
1 x DC or AC power in (via power supply unit)
Optional:
1 x barcode reader interface Pepperl+Fuchs
Pscan-D/B (Ex i)
"interface 3": 1 x barcode reader interface for
wired 1-D scanners DM-160-D*, DM-Z1-
160-D-* and base station DMx61-B-* and
DM-Z1-x61-B-* (Ex i)
"interface 4": 1 x barcode reader interface for
wired 2-D Scanner DM-Z1-260-D-* (Ex i)
"interface 5": 1 x RS-232 interface with Power
Supply for miscellaneous devices and periph-
erals (Ex i)
1 x RS-485 (Ex e)
1 x Ethernet 100/1000Base-TX (Ex e) Blue-
tooth v4.0, communication distance up to 30
m in open terrain, transmission power +8
dBm, transmission frequency 2.402 ... 2.48
GHz
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
non-Bluetooth products only
Radio and telecommunication terminal equipment
Directive 2014/53/EU EN 301 328 V2.1.1
EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
Bluetooth products only
RoHS
Directive 2011/65/EU (RoHS) EN 50581:2012-09
Ambient conditions
Operating temperature -20 ... 50 °C (-4 ... 122 °F)
Display might react sluggishly below 0 °C
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
Relative humidity 93% at 40°C, non-condensating, according to
EN60068-2-78
Altitude Operating altitude max. 2000 m

VisuNet GXP
Product Description
2020-09
11
Shock resistance 18 shocks 15 g , 11 ms all axis, EC 60068-2-
27
Vibration resistance 10 ... 150 Hz, +/- 0.075 mm , 1g, 10 cycles per
axis according to EN60068-2-6
Mechanical specifications
Degree of protection P66 (individual components and entire sys-
tem with housing)
Material Internal:
Panel: anodized aluminum (TCU, PCU, PSU),
powder coated aluminum (DPU)
External:
Bezel: stainless steel A S 304 (1.4301)
System housing-H4: stainless steel A S 304
(1.4301), bead blasted, typical surface rough-
ness Ra = 1.6 µm
nstallation Flush-mount installation (requires customized
mounting kit)
Panel-mount installation into system housing
with bezel
Panel-mount installation into cabinet with
Bezel and standard mounting kit
Mass Panel (DPU with bezel, TCU, PSU DC):
approx. 23 kg\r Panel (DPU with bezel, TCU,
PSU AC): approx. 24 kg\r System housing
(AG-XX00): approx. 11 kg
Dimensions Panel (DPU with bezel, TCU, PSU DC): 625
mm x 459 mm x 120 mm
Panel (DPU with bezel, TCU, PSU AC): 625
mm x 459 mm x 137 mm
Panel with system housing: 625 mm x 459 mm
x 173 mm
Panel cut-out dimensions: 583 mm x 417 mm
(installation surface)
Data for application in connection with hazardous areas
EU-type examination certificate Zone 1/21: BVS 17 ATEX E 036 X
Zone 2/22: BVS 17 ATEX E 037 X
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013, EN 60079-
5:2015, EN 60079-7:2015, EN 60079-
11:2012, EN 60079-31:2014
International approvals
UL approval E492874
ECEx approval ECEx BVS 17.0029X
Standards EC 60079-0:2011, EC 60079-5:2015, EC
60079-7:2015, EC 60079-11:2011, EC
60079-31:2013
Ambient conditions

2020-09
12
VisuNet GXP
Product Description
Marking
Note
For more technical information, refer to the documentation for the individual components:
•Display Units DPU1100-J1* and DPU1200-J2*
•AC Power Supply Units PSU1100-J1-AC-N0 and PSU1200-J2-AC-N0
•DC Power Supply Units PSU1100-J1-DC-N0 and PSU1200-J2-DC-N0
•Thin Client Units TCU1100-J1-* and TCU1200-J2-*
•Personal Computer Units PCU1100-* and PCU1200-*
•Peripherals such as keyboards or barcode readers
ATEX
RM-GXP1100-J1-*
PC-GXP1100-J1-* 2G Ex eb q ib [ib] C T4 P66 Gb
2D Ex tb [ib] C T85°C P66 Db
RM-GXP1200-J2-*
PC-GXP1200-J2-* 3G Ex ec [ib] q C T4 P66 Gc
3D Ex tc [ib] C T85 °C P66 Dc
IECEx
RM-GXP1100-J1-*
PC-GXP1100-J1-*
Ex eb q ib [ib] C T4 P66 Gb
Ex tb [ib] C T85°C P66 Db
RM-GXP1200-J2-*
PC-GXP1200-J2-*
Ex ec [ib] q C T4 P66 Gc
Ex tc [ib] C T85 °C P66 Dc
UL

VisuNet GXP
Product Description
2020-09
13
2.3 Dimensions
Pedestal Mount
VisuNet GXP system H1 housing installed into AG-XX00 housing with additional PEDESATAL-
XX00-* pedestals and EXTA2-* keyboard inside an -F housing with -G mounting version (1-Arm
for mounting to AG-XX00 housing)
Note
For more options and information, refer to the VisuNet GXP Mounting Options datasheet.
1 Shown with PEDESTAL-XX00-124-3-304-TRN-N0
2 Shown with PEDESTAL-XX00-124-4-304-TRN-N0
625
451
(1687)
~ 400
173
1236
ø 165
104
154
214
45°
~ 400
104
154
204
45°
1 2
263
459
173
459
Note
EXTA2-* keyboard and PEDESTAL-XX00-* pedestals must be ordered separately.

2020-09
14
VisuNet GXP
Product Description
Wall Mount
Figure 2.3 VisuNet GXP system H1 housing installed into AG-XX00 housing with additional WALL-
BRACKET-XX00-3-304-N0 and EXTA2 keyboard inside an -F housing with -G mounting
version (1-Arm for mounting to AG-XX00 housing)
Wall Mount ole Pattern
Figure 2.4
256
450
635
582
8
625
451

VisuNet GXP
Product Description
2020-09
15
Panel Mount
Figure 2.5 VisuNet GXP system S1 housing including bezel, prepared for panel mounting, with K T-
PM-XX00-22F-304-N0 kit for panel mounting
23.5
633
584
418
467
17.3 114

2020-09
16
VisuNet GXP
Mechanical nstallation
3 Mechanical Installation
3.1 Unpacking
The VisuNet GXP comes with its core components preassembled. These components consist
of a display unit (DPU), power supply unit (PSU), and thin client unit (TCU) or PC unit (PCU). f
the housing option is chosen, the components come pre-mounted into the housing.
Figure 3.1 VisuNet GXP in the box
Warning!
Risk of injury
Handling the VisuNet GXP components without gloves may cut fingers, hands, or wrists.
Wear gloves at all times during installation.
Caution!
Scratches and damage
GXP components may become scratched or damaged if they are placed onto or slid across
hard surfaces.
Warning!
Danger resulting from scratched DPU screen
Scratches in the DPU screen weaken the glass structure. This may result in glass breakage in
the event of an explosion. Explosion protection is no longer ensured if a DPU with a scratched
screen is used.
NEVER use a DPU with a scratched screen in a hazardous area. f the surface is damaged in
any way, return the DPU to Pepperl+Fuchs at once and replace it with a new one. See chapter
3.3.13 for information about removing the DPU.

VisuNet GXP
Mechanical nstallation
2020-09
17
Figure 3.2 To help protect the VisuNet GXP components once they have been removed from the box,
use the enclosed foam brackets.
Figure 3.3 To protect the DPU front screen, place the VisuNet GXP face down onto the foam brackets.
Using Foam Brackets During Installation

2020-09
18
VisuNet GXP
Mechanical nstallation
3.2 Electrical Installation
When installing the VisuNet GXP system, always ensure a proper grounding of all components,
including housing and mounting parts (e.g., pedestal and wall bracket) with a cable diameter of
at least 4 mm
2
in accordance with EC 60079-14.
The VisuNet GXP is shipped with the following protective earth (PE) wiring connections, if the
AG-XX00 housing option is selected:
•PE wire from the DPU PE stud to the AG-XX00 housing PE stud.
•PE wire from the PSU PE stud to the AG-XX00 housing PE stud.
Warning!
Danger of Explosion
Cable insulation may become damaged if cables and connection lines are not used in ade-
quate temperature ranges. Thus, short circuits within the cable may occur which in turn may
give rise to sparks and/or surface temperatures capable of triggering an ignition.
Only use cables and connection lines which are suitable to be used within a temperature rating
of 80 °C if the system components are used within an ambient operating temperature of T
a
> 40
°C.
Note
Refer to the manuals of the individual VisuNet GXP components for more information on
electrical installation and wiring.
Danger!
Explosion hazard from wrong or missing grounding
Wrong or missing grounding can cause sparks. This can ignite the surrounding potentially
explosive atmosphere.
•Ground the device. Observe the grounding requirements.
•Ensure that external ground connections exist, are in good condition, and are not dam-
aged or corroded.
Warning!
Risk of electric shock or property damage from inadequate grounding
f you do not ground the device correctly, this could result in potential equalization currents.
These currents could hurt operating personnel or cause property damage.
Ground the device via the grounding bolt. Ensure that a correct potential equalization is guar-
anteed at all times.

VisuNet GXP
Mechanical nstallation
2020-09
19
3.3 System Installation
3.3.1 General Installation Information
Observe the following requirements when installing the system components.
•The equipment must be installed by competent personnel in accordance with the instruc-
tions. National laws and regulations must be observed.
•The building installation must provide a 20 A overcurrent protection.
•The installer must make a readily accessible disconnect device available.
•The safety of any system incorporating the PSU is the responsibility of the assembler of
the system.
Included with Delivery
•Pre-assembled VisuNet PC- or RM-GXP panel (pre-mounted into AG-XX00 housing
when "H1" option is selected)
•2 x protective tubes
•1 x Ferrite ring with 1 x Ferrite key
•Screws for housing
Items Ordered Separately
•Pedestal that is compatible with AG-XX00 housing (StandardLine or BasicLine pedestal)
•Optional EXTA2-* keyboard
Warning!
Risk of injury
Lifting the device on your own may lead to injury.
Do not attempt to lift the device on your own. Use a crane or have another person help you.
Warning!
Proper installation on the floor
t is the installer's responsibility to select a suitable location with sufficient strength to hold the
equipment. t is the installer's responsibility to select the proper screws based on the installa-
tion conditions.

2020-09
20
VisuNet GXP
Mechanical nstallation
3.3.2 Preparing for Pedestal Installation
For floor mounting, the preferred installation option uses PEDESTAL-XX00-* with either 3 or 4
cable glands. The pedestal is shipped with a pre-installed rotating coupling with four bolts and
a PE wire, which is attached to the pedestal tube.
Figure 3.4 Pedestal with optional 3 or 4 cable glands
1 PEDESTAL-XX00-124-3-304-TRN-N0 with 3 cable glands
2 PEDESTAL-XX00-124-4-304-TRN-N0 with 4 cable glands
104
154
214
45°
104
154
204
45°
1 2
263
Other manuals for VisuNet GXP RM-GXP1100-22F
1
This manual suits for next models
3
Table of contents
Other Pepperl+Fuchs Monitor manuals

Pepperl+Fuchs
Pepperl+Fuchs DPU1100-J1 Series User manual

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GXP Series User guide

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GXP Series User manual

Pepperl+Fuchs
Pepperl+Fuchs KFD2-SR2-Ex2.W.SM User manual

Pepperl+Fuchs
Pepperl+Fuchs VisuNet GMP DM200 Series User manual

Pepperl+Fuchs
Pepperl+Fuchs DA6-SSI/A-U User manual

Pepperl+Fuchs
Pepperl+Fuchs VISUNET GMP DM User manual

Pepperl+Fuchs
Pepperl+Fuchs VisuNet IND DM5 Series User manual

Pepperl+Fuchs
Pepperl+Fuchs VisuNet DPU2100 Series User manual

Pepperl+Fuchs
Pepperl+Fuchs VBA-2E2A-KE4-ENC/SSI-S User manual