PERCo ST-01 Installation and operating instructions

ASSEMBLY AND OPERATION MANUAL
STD-01
DoubleSided Section
ST-01
Speed Gate

ST-01
Speed gate
STD-01
Double-sided section
Assembly and Operation Manual

CONTENTS
1APPLICATION ......................................................................................................................... 3
2OPERATING CONDITIONS .................................................................................................... 3
3TECHNICAL SPECIFICATIONS ............................................................................................. 4
4DELIVERY SET ....................................................................................................................... 4
4.1Standard delivery set......................................................................................................... 4
4.1.1ST-01 Speed gate...................................................................................................................... 4
4.1.2STD-01 double-sided section .................................................................................................... 5
4.2Optional equipment ........................................................................................................... 6
5DESIGN AND OPERATION .................................................................................................... 9
5.1Main features..................................................................................................................... 9
5.2Design ............................................................................................................................. 12
5.2.1Section ..................................................................................................................................... 12
5.2.2Indication blocks ...................................................................................................................... 13
5.2.3RC-panel.................................................................................................................................. 13
5.2.4Control board ........................................................................................................................... 14
5.2.5Control signals ......................................................................................................................... 16
5.2.6Control modes.......................................................................................................................... 17
5.2.7Speed gate operation algorithm .............................................................................................. 18
5.3Operating devices ........................................................................................................... 19
5.3.1RC-panel connection ............................................................................................................... 19
5.3.2Fire Alarm device..................................................................................................................... 20
5.3.3Operation from the ACS .......................................................................................................... 20
5.4Optional devices connected to the speed gate ............................................................... 20
5.4.1PASS outputs........................................................................................................................... 20
5.4.2Siren......................................................................................................................................... 21
5.4.3External indication ................................................................................................................... 21
6MARKING AND PACKAGING ............................................................................................... 22
7SAFETY REQUIREMENTS................................................................................................... 22
7.1Installation safety requirements....................................................................................... 22
7.2Operation safety requirements ........................................................................................ 23
8INSTALLATION ..................................................................................................................... 23
8.1Installation details............................................................................................................ 23
8.2Installation tools............................................................................................................... 23
8.3Cable length .................................................................................................................... 24
8.4Installation order.............................................................................................................. 24
8.5Mounting surface marking layouts................................................................................... 27
8.6Speed gate wiring diagram.............................................................................................. 29
8.7Training mode ................................................................................................................. 30
8.8“Auto-opening in the selected direction” mode................................................................ 31
8.9Assembly and disassembly of the speed gate components............................................ 32
8.9.1Central post cover plate........................................................................................................... 32
8.9.2Front panel of the side post ..................................................................................................... 33
8.9.3Swing panel ............................................................................................................................. 33
8.9.4Swing panel cover plate........................................................................................................... 34
8.9.5Central post indication block.................................................................................................... 35
8.9.6Section top cover ..................................................................................................................... 36
8.9.7Bottom duct cover.................................................................................................................... 38
8.9.8Filling glass .............................................................................................................................. 38
9OPERATION.......................................................................................................................... 40
9.1Power-up......................................................................................................................... 40
9.2Pulse control mode.......................................................................................................... 40
9.3Potential control mode..................................................................................................... 41
9.4In case of an emergency................................................................................................. 41
9.4.1“Emergency” mode .................................................................................................................. 41
9.4.2“Fire Alarm” mode.................................................................................................................... 42
9.4.3Troubleshooting ....................................................................................................................... 42
10MAINTENANCE..................................................................................................................... 42
11TRANSPORTATION AND STORAGE .................................................................................. 42
Appendix 1. Operation algorithm at pulse control mode ............................................................ 43
Appendix 2. Operation algorithm at potential control mode ....................................................... 43

ST-01 Speed gate, STD-01 Double-sided section
Dear Customer!
Thank you for purchasing PERCo product. Please follow instructions given in this Manual
carefully and this high-quality product will provide many years of trouble-free use.
Assembly and Operation Manual for the ST-01 Speed gate and STD-01 Double-sided section
(hereinafter – the Manual) contains the instructions on safe transportation, storage, installation,
operation and maintenance of the above-mentioned products. The installation must be carried out
by qualified installers in strict accordance with the Manual.
Abbreviations adopted in the Manual:
ACS – access control system;
CLB – control logic board;
PS – power supply;
RC-panel – remote control panel;
WRC – wireless remote control;
Due to continuous improvement of products, the Manufacturer reserves the right to modify, without
previous notice, the product design not aggravating its technical specifications.
1 APPLICATION
ST-01 Speed gate (hereinafter – the speed gate) is designed for pedestrian passage control at
entrance points of administrative buildings, banks, shops, railway terminals, airports, etc.
Attention!
ST-01 speed gate is designed for the passage of pedestrians taller than 1 m,
otherwise correct operation of the speed gate is not guaranteed. Pass through the
speed gate of children less than 1 m height tall can only be carried by the arm
accompanied by adults1.
The speed gate features two sections: ST-01/M (hereinafter – Master section) and ST-01/S section
(hereinafter – Slave section). In a standard delivery set the speed gate allows to arrange one
passage lane. The width of the passage lane depends on the chosen swing panel width.
Use STD-01 double-sided section (hereinafter – double-sided section) to arrange more passage
lanes. Each double-sided section provides one extra passage lane.
Note:
Inside the turnstile sections, it is possible to install access card readers as manufactured by
PERCo (IR03.1,MR07 OEM, RP-15.2), and by third-party manufacturers. The selection of
the reader, its purchase and installation into the product are carried out by the customer
(installer) in accordance with the checkpoint design and the ACS and controller
characteristics. Card readers are not included in the standard delivery set of the turnstile!
Readers must meet the following requirements:
Overall dimension (length × width × height) .................................... max. 155×68×28 mm
Read range ..................................................................................................... min. 40 mm
2 OPERATING CONDITIONS
The product with regard to resistance to environmental exposure complies with GOST15150-69
category NF4 (operation in premises with climate control).
Operation of the speed gate is allowed at an ambient air temperature from +1°C to +50°C and
relative air humidity 80% at +25°C.
1If the turnstile is installed in children's institutions or in organizations working with children, where more
secure passage mode is required, it is recommended to reflash turnstile controller with a special firmware
(ST01_Children). Its main feature is the safety zone increased to the whole passage zone of the turnstile
and particular operation algorithm when swing panels do not close if at least one sensor of the turnstile is
active.
In order to get necessary recommendations regarding the firmware installation, please contact PERCo
technical support team.
3

Assembly and Operation Manual
3 TECHNICAL SPECIFICATIONS
Operating voltage......................................................................................................... 24±2.4 VDC
Current consumption.......................................................................................................... max. 6.5 A
Power consumption...................................................................................................... max. 160 W
Throughput rate in a single passage mode ............................................................. 60 persons / min
Passageway width:
with ATG-300, ATG-300H swing panel ............................................................................ 650 mm
with ATG-425 swing panel ............................................................................................... 900 mm
with ATG-475 swing panel ............................................................................................. 1000 mm
Number of intrusion detectors:
upper level ................................................................................................................................. 14
lower level ................................................................................................................................. 28
RC-panel cable length ..................................................................................................... min. 6.6 m
IP rating ................................................................................................................... IP41 (EN 60529)
Electric shock protection class.................................................................................... III (IEC 61140)
Mean time to failure ................................................................................... min. 5,000,000 passages
Mean lifetime .......................................................................................................................... 8 years
Overall dimensions(L × W × H):
with ATG-300 swing panel ........................................................................ 1820×1050×1010 mm
with ATG-300H swing panel ...................................................................... 1820×1050×1300 mm
with ATG-425 swing panel ........................................................................ 1820×1300×1010 mm
with ATG-475 swing panel ........................................................................ 1820×1400×1010 mm
Note:
Use the following formula to calculate the overall speed gate width in case several passage
lanes are arranged (Fig. 5): Loverall= 920 n + 1170 m +1270 k +130 (mm), where:
n– number of ATG-300 and ATG-300H swing panel sets installed;
m– number of ATG-425 swing panel sets installed;
k– number of ATG-475 swing panel sets installed.
Weight (net):
ST-01/M section ............................................................................................................ max 85 kg
ST-01/S section ............................................................................................................ max 85 kg
STD-01 double-sided section ..................................................................................... max 100 kg
ATG-300 swing panel ..................................................................................................... max 6 kg
ATG-300H swing panel .................................................................................................. max 9 kg
ATG-425 swing panel ..................................................................................................... max 8 kg
ATG-475 swing panel ..................................................................................................... max 9 kg
4 DELIVERY SET
4.1 Standard delivery set
4.1.1 ST-01 Speed gate
Main equipment:
ST-01/M (Master)section ........................................................................................ 1 (in box #1)
ST-01/S (Slave)1 section ........................................................................................... 1 (in box #2)
Section top cover .......................................................................................... 2 (in a separate box)
The power supply is connected to the control board located in the Master section (on the Master side of
the double-sided section) and has the “ST-01.771” marking.
Current consumption and power consumption are given for each product ST-01 and STD-01 individually.
Maximum allowable cable length of the RC panel is 40 m (supplied upon request).
Overall dimensions of the speed gate with different types of panels are shown in Fig. 1, 2, 3, 4, 5.
Both sections are delivered with disassembled top covers, panels, panel cover plates and central
indication blocks.
4

ST-01 Speed gate, STD-01 Double-sided section
Note:
The type of top cover is to be chosen by the Customer. The following top cover models for
the ST-01 speed gate are available:
STC-01G – is made of tempered glass and features built-in indication block;
STC-01S – is made of stainless steel, features a plastic plate, indication block is not
provided;
STC-01GS – is made of tempered glass, features built-in indication block and a central
metal plate for installing additional equipment.
Central post indication block ............................................................. 2 (1 in each box #1 and #2)
Swing panel cover plate .................................................................... 4 (2 in each box #1 and #2)
Glass swing panel ........................................................................................ 2 (in a separate box)
Note:
Swing panels are purchased separately. The type of the swing panel is chosen by the
customer. The following swing panel models are available (see Fig. 1, 2, 3, 4):
ATG-300 – for 650 mm passageway arrangement;
ATG-300H – increased height swing panel for 650 mm passageway arrangement;
ATG-425 – for 900 mm passageway arrangement;
ATG-475 – for 1000 mm passageway arrangement.
RC-panel with cable .................................................................................................. 1 (in box #1)
Jumper ...................................................................................................................... 3 (in box #1)
Self-adhesive rubber pad with mnemonic image ...................................................... 2 (in box #1)
Installation tools:
Section top cover mounting kit:
M5×16 bolt .................................................................................. 16 (8 in each box #1 and #2)
washer (5) ................................................................................... 16 (8 in each box #1 and #2)
Central post indication block mounting kit:
M5×16 bolt .................................................................................... 4 (2 in each box #1 and #2)
washer (5) ..................................................................................... 4 (2 in each box #1 and #2)
Swing panel cover plate mounting kit:
M4×10 screw ................................................................................ 8 (4 in each box #1 and #2)
washer (4) ..................................................................................... 8 (4 in each box #1 and #2)
Swing panel mounting kit:
M10×30 bolt .................................................................................. 6 (3 in each box #1 and #2)
M10 nut ......................................................................................... 6 (3 in each box #1 and #2)
washer (10) ................................................................................. 12 (6 in each box #1 and #2)
plastic bushing .............................................................................. 6 (3 in each box #1 and #2)
Template for marking on the mounting surface (HDF) .............................................. 1 (in box #1)
Technical documentation:
Certificate .................................................................................................................. 1 (in box #1)
Assembly and operation manual ............................................................................... 1 (in box #1)
Packaging:
Box #1 for ST-01/M section ......................................................................................................... 1
Box #2 for ST-01/S section ......................................................................................................... 1
Box for section top covers ........................................................................................................... 1
Box for swing panels ................................................................................................................... 1
4.1.2 STD-01 double-sided section
Main equipment:
Double-sided section................................................................................................................. 1
Section top cover .......................................................................................... 1 (in a separate box)
The section is delivered with disassembled top cover, swing panels, panel cover plates and central
indication blocks.
5

Assembly and Operation Manual
Note:
The type of top cover is to be chosen by the Customer. The following top cover models for
the ST-01 speed gate are available:
STC-01G – is made of tempered glass and features built-in indication block;
STC-01S – is made of stainless steel, features a plastic plate, indication block is not
provided;
STC-01GS – is made of tempered glass, features built-in indication block and a central
metal plate for installing additional equipment.
Central post indication block ....................................................................................................... 2
Swing panel cover plate .............................................................................................................. 4
Glass swing panel ........................................................................................ 2 (in a separate box)
Note:
Swing panels are purchased separately. The type of the swing panel is chosen by the
customer. The following swing panel models are available (see Fig. 5):
ATG-300 – for 650 mm passageway arrangement;
ATG-300H – increased height swing panel for 650 mm passageway arrangement;
ATG-425 – for 900 mm passageway arrangement;
ATG-475 – for 1000 mm passageway arrangement.
RC-panel with cable .....................................................................................................................1
Jumper ........................................................................................................................................ 3
Self-adhesive rubber pad with mnemonic image ........................................................................ 2
Installation tools:
Section top cover mounting kit:
M5×16 bolt .............................................................................................................................. 8
washer (5) ............................................................................................................................... 8
Central post indication block mounting kit:
M5×16 bolt ...............................................................................................................................4
washer (5) ................................................................................................................................4
Swing panel cover plate mounting kit:
M4×10 screw .......................................................................................................................... 8
washer (4) ............................................................................................................................... 8
Swing panel mounting kit:
M10×30 bolt ............................................................................................................................ 6
M10 nut ................................................................................................................................... 6
washer (10) ........................................................................................................................... 12
plastic bushing ........................................................................................................................ 6
Technical documentation:
Certificate .................................................................................................................................... 1
Packaging:
Box #1 (for double-sided section) ................................................................................................ 1
Box for section top cover ............................................................................................................. 1
Box for swing panels ................................................................................................................... 1
4.2 Optional equipment
The following equipment can be ordered in addition to the standard delivery set:
IR03.1 (HID / EMM), or MR07 OEM (Mifare), or RP-15.2 (HID / EMM, Wiegand) type
card readers............................................................................................. 2 per a passage lane
FP-01Q Front panel for installing a barcode scanner ............................... in the required quantity
FP-01C Front panel with integrated card reader capture .......................... in the required quantity
FP-01A Front panel with a bracket for additional equipment .................... in the required quantity
Power supply unit ..................................................................................... in the required quantity
Wireless remote control.......................................................................... in the required quantity
PFG IH10 (“SORMAT”, Finland) anchor bolts with washers ..................... in the required quantity
The WRC kit consists of a receiver, connected to the control board and a transmitter in the form of a fob.
6

ST-01 Speed gate, STD-01 Double-sided section
Figure 1. Speed gate overall dimensions with ATG-300 swing panels
Figure 2. Speed gate overall dimensions with ATG-300H swing panels
7

Assembly and Operation Manual
Figure 3. Speed gate overall dimensions with ATG-425 swing panels
Figure 4. Speed gate overall dimensions with ATG-475 swing panels
8

ST-01 Speed gate, STD-01 Double-sided section
Figure 5. Speed gate overall dimensions with several passage lanes
5 DESIGN AND OPERATION
5.1 Main features
The speed gate allows to perform several authorized single passages in a row in one direction
without the swing panels being closed.
The speed gate is a normally-open device, which means that when the equipment is de-
energized the swing panels move freely at ±90º angle.
The intrusion detectors are installed on two levels throughout the speed gate passage lane.
This allows monitoring user’s location inside the passage lane. The speed gate also makes it
possible for several users to be in the same passage lane at the same time.
There are several swing panel models, that can be chosen according to the passage lane
width and to the operation peculiarities upon making an order.
Section top covers may be chosen when ordering; they can be made of tempered glass or
stainless steel.
A wide range of optional equipment can be installed: card capture reader, barcode reader,
face recognition terminal etc.
The number of the passage lanes can be increased with STD-01 double-sided section
installation.
In case several passage lanes are arranged, the front-end indication blocks display the
passage direction.
The speed gate can operate in pulse and potential modes.
It is possible to switch the speed gate to “Auto-opening in the selected direction” mode –
entering the speed gate will force the swing panels to automatically open in the preset
direction and to close after the passage is finished.
The speed gate will generate an alarm signal in all operating modes if the passage lane is
occupied for more than 30 seconds.
9

Assembly and Operation Manual
Figure 6. ST-01 overall view:
1 – swing panel; 2 – central post; 3 – central post indication block;
4 – swing panel cover plate; 5 – central post cover plate; 6 – central post rear panel;
7 – side post; 8 – front panel; 9 – front end indication block;
10 – section top cover; 11 – top cover indication block; 12 – top duct;
13 – filling glass; 14 – bottom duct cover; 15 – bottom duct;
16 – power supply cable; 17 – RC-panel with the cable;
18 – Fire Alarm cable1; 19 – DC connection cable;
20 – CAN connection cable.
Not included in the standard delivery set.
10

ST-01 Speed gate, STD-01 Double-sided section
Figure 7. STD-01 overall view:
1 – swing panel; 2 – central post; 3 – central post indication block;
4 – swing panel cover plate; 5 – central post cover plate; 6 – central post rear panel;
7 – side post; 8 – front panel; 9 – front end indication block; 10 – section top cover;
11 – top cover indication block; 12 – top duct; 13 – filling glass;
14 – bottom duct cover; 15 – bottom duct; 16 – power supply cable1;
17 – RC-panel with cable; 18 – Fire Alarm cable1;
19 – to the Master section (side) DC cable;
20 – to the Master section (side) CAN cable;
21 – from the Slave section (side) DC cable;
22 – from the Slave section (side) CAN cable2.
1Not included in the standard delivery set.
From ST-01 or other STD-01 delivery set.
11

Assembly and Operation Manual
The equipment can operate as an operating device as a part of ACS or as a standalone unit
operated from the RC-panel.
The speed gate provides the possibility of proximity card readers installation inside the posts
under the glass section top cover.
The glass section top cover (STC-01G, SDC-01G,STC-01GS,SDC-01GS) is equipped with
indication block (blocks), which features passage granting indicator and proximity card
presentation zone indicator.
The speed gate features the swing panel position adjustment in the initial (locked) position
(training mode).
Indication blocks of the passage grant / denial are located in the user line-of-sight range on the
speed gate central section allowing complete the passage as fast as users can walk through
the turnstile.
The equipment provides the possibility of external indication block connection to duplicate
passage grant / denial indication.
Acoustic alarm (siren) connection is provided to warn the operator about unauthorized access
attempt.
Automatic emergency opening of the passage is provided upon receipt of an “Alarm” signal.
The “Alarm” signal can be sent by the emergency system device or by the operator using the
emergency button (hereinafter – emergency passage opening device).
The components are made of polished stainless steel. The swing panels and the filling glass
are made of tempered glass of 8 -10 mm thick.
5.2 Design
The speed gate design is shown in Fig. 6; the double-sided section design is shown in Fig. 7. The
numbers of the equipment parts are stated in the Manual in accordance with Fig. 5 and 6.
The speed gate consists of two sections, Master and Slave, and an RC-panel. Each section is
equipped with a motorized swing panel (1). Slave section is connected to Master section with two
connection cables (19, 20).
Use double-sided sections to arrange more passage lane. The double-sided section is completed
with an RC-panel and equipped with two swing panels (1): on the Master side and on the Slave
side. Each swing panel has its motor drive. Slave side is connected to the speed gate Master
section or to the Master side of another double-sided section with two connection cables (19, 20).
The speed gate Slave section (Slave side of the next double-sided section) is connected to Master
side with two connection cables (21, 22) from the standard delivery set.
5.2.1 Section
Each section consists of three posts: one central (2) and two side (7) posts. The posts are
interconnected by a top duct (12) and two bottom ducts (15). Each section features a section top
cover (10), which covers a top duct. The bottom ducts are covered with bottom duct top covers
(14).
The spacing between posts is completed with filling glass (13), which prevents unauthorized entry
into the passageway. Bolts, which fasten the filling glasses to the central post, are covered with
central post rear panel (6). Bolts, which fasten the filling glasses to the side posts, are covered with
the front panels (8).
The section top cover is equipped with an indication block (blocks) (11), which features a passage
granting indicator (green arrow) and a card presentation zone indicator (“a hand with a card”
pictogram).
The side posts are equipped with the front-end indication blocks (9) indicating the passage
direction or passage denial (white arrow or red cross).
The central post (2) features an indication block (3) with square color indicators of passage grant /
denial.
The swing panel (1) is fixed to the central post rotating support. The rotating support is covered
with the central post cover plate (5). The rotating support is driven by motor, located under the
swing panel cover plate (4).
12

ST-01 Speed gate, STD-01 Double-sided section
The glass section top cover (STC-01G,SDC-01G,STC-01GS,SDC-01GS) features an indication
block (blocks) (11), that consists of passage granting indicator (green arrow) and access card
presentation zone indicator (“hand with a card” pictogram).
The bottom part of the Master section central post features ST-01.771 speed gate control board
(hereinafter – control board). The PS, the RC-panel (WRC receiver), Fire Alarm device and Slave
section connection cables are connected to the control board.
5.2.2 Indication blocks
Each section features the following indication blocks:
Top cover (STC-01G,SDC-01G,STC-01GS,SDC-01GS) indication block (11) includes a
white indicator (a hand with a card), indicating the card presentation zone and a green
indicator (an arrow), which lights up in case the passage in this direction is granted:
– green indicator of passage granting
– white indicator of card presentation zone
Central post indication block (3) is designed for passage grant (green light) / denial (red
light) indication for each direction.
Front end indication block (9) is designed for indicating passage direction through the speed
gate. It displays the constant indication (white arrow or red cross):
– red indicator of passage denial
– white indicator of the passage direction
The type of indication of the front-end block can be chosen during the installation of the
speed gate by connecting the front-end cable to the corresponding indication control
module connector (located under the speed gate cover on the protection plate, Fig. 20). By
default, the cable is connected to the ARROW connector, the area where white arrow
points at. To access the speed gate indication control module, the section top cover is to be
removed (10) (see Sect. 8.9.6).
5.2.3 RC-panel
RC-panel (17) is a small table device made of shockproof ABS plastic. RC-panel is designed for
speed gate operation in the manual mode, in which the operator sends commands to the
equipment. The overall view of the RC-panel is shown in Fig. 8.
RC-panel housing features three control buttons for sending commands. The middle STOP button
serves for setting the “Always locked” mode. The LEFT and RIGHT buttons serve to open the
passage in the chosen direction. Up above the buttons there are LED lights, indicating passage
direction status. The red “Stop” indicator shows the “Always locked” operating mode. The possible
operation commands and RC-panel indication for pulse and potential operating modes are stated
in Tables 7and 8.
13

Assembly and Operation Manual
Figure 8. Overall view and dimensions of the RC-panel
1, 2, 3 – LEFT, STOP, RIGHT buttons for mode setting;
4, 6 – green “Left”, “Right” indicators; 5 – red “Stop” indicator
5.2.4 Control board
Speed gate control board (Fig. 9) is installed in the central post of Master section. Remove the
central post cover plate in order to access the board (see Sect. 8.9.1).
The control board features a microcontroller, which processes the incoming control commands,
transferred to Unlock A, Stop, Unlock B and Fire Alarm control inputs, monitors the status of swing
panels turn optical sensors and creates commands for the motor drive of the speed gate swing
panels on the basis of the data received.
The microcontroller also creates signals on the control board outputs: for indication on the RC-
panel (Led A, Led Stop and Led B outputs), for the external indication (Light A, Light B outputs),
about the passage registration in the corresponding direction (PASS A and PASS B), about the
alarm (Alarm). The control board features:
Figure 9. Control board overall view
14

ST-01 Speed gate, STD-01 Double-sided section
Connector blocks to connect:
X1 (Power)– speed gate power supply.
X2 (RC) – operating devices: RC-panel, wireless remote control, control outputs of the
ACS-controller, Fire Alarm device.
X3 (ACS) – sirens and ACS-controller inputs to the control board outputs.
X4 – remote indication blocks to the controller board relay outputs.
X5 – DC and CAN connection cables of swing panel motor drives.
X9 – mini-USB connector for speed gate built-in software update.
Connectors for jumper installation:
XP1 (Program) – secondary connector.
XP2 (Mode 1) – connector not used (jumper installed upon delivery).
XP3 (+12V) – connector for turning on LED indication on the control board.
XP4 (Update) – connector for switching the control board to a Software update mode
through USB interface. The jumper is removed by default.
XP6 (BUZZ) – connector for turning on the buzzer on the control board. Buzzer operation
duplicates operation unit sound indication and siren activation. The jumper is installed by
default, which corresponds to the activated buzzer.
XP7 (Mode2) – not used. During the operation the jumper should be removed.
Switchers:
Pulse – to turn the speed gate to a pulse control mode. By default, the switch is in ON
position, which corresponds to a pulse speed gate operating mode.
FA_Dir – to choose swing panel direction of rotation in case an emergency passage
opening (Fire Alarm) signal is sent. By default, the switch is in OFF position, which
corresponds to the swing gate being opened in B direction.
Size1, Size2 – to set the speed gate swing panels size. By default, both switches are in
OFF position.
Table 1. Positioning of Size1, Size2 switches according to the swing panel type
Switcher positioning
Swing panel model Size1 Size2
ATG-300 ON OFF
ATG-300H ON ON
ATG-425, ATG-475 OFF OFF
Test1 – not used. When operating, the switch must be in OFF position.
Test2 – for turning on LED indication on intrusion detectors boards. By default, both switches
are in OFF position, which corresponds to the indication being switched off.
R1 – turns on the “Auto-opening in the selected direction” mode (Sect. 8.8). By default, the
switch is turned OFF (see Table 2).
R2
– switches the speed gate to the training mode (Sect. 8.7), if the R1 switch is in OFF
position, or is used for selecting the direction of “Auto-opening” mode if the R1 switch is in
ON position. By default, the switch is set in OFF position (see Table 2).
Table 2. Speed gate operating modes in different positions of R1 and R2 switches
Switch position
R1 R2 Mode
OFF OFF Training and “Auto-opening” modes are turned on
OFF ON Training mode is switched on (Sect. 8.7)
ON OFF "Auto-opening”mode is switched on in A direction (Sect. 8.8)
ON ON “Auto-opening”mode is switched on in B direction (Sect. 8.8)
15

Assembly and Operation Manual
Table 3. Function of the control board terminal block contacts
Connector block №Contact Function
1 +24V
X1 (Power) 2 GND External power supply connection
1 GND General
2 Unlock A A direction control input
3 Stop Passage denial control Input
4 Unlock B B direction control input
5 Led A A direction control input on the RC-panel
6 Led Stop Passage denial control input on the RC-panel
7 Led B B direction control input on the RC-panel
8 Sound RC-panel sound signal output
9 Fire Alarm
X2 (RC)
10 GND Emergency passage unlocking control input
1 +12V +12V output for additional equipment powering
2 GND General
3 Alarm1
4 Alarm2 Siren connection output
5 Common Common for PASS A, PASS B outputs
6 PASS A PASS A relay contact (passage in A direction)
X3 (ACS)
7 PASS B PASS B relay contact (passage in B direction)
1 NO1 Normally open contact of the Light A output
2 C1 Common contact of the Light A output
3 NC Normally closed contact of the Light A output
4 NO2 Normally open contact of the Light B output
X4
5 C2 Common contact of the Light B output
5.2.5 Control signals
Speed gate operation is performed by sending control signals to Unlock A, Stop and Unlock B
outputs. The control signal is sending a low-level signal to Unlock A, Stop and Unlock B contacts
regarding GND contacts. Normally open relay contact or layout with an open collector output can
serve as a control element (Fig. 10 and 11).
Speed gate emergency unlocking is performed by sending a control signal to Fire Alarm input. The
control signal is a low-level signal release from Fire Alarm contact regarding GND contact. A
normally closed relay contact or an open collector output layout can serve as a control element. In
this case all other incoming control commands are ignored. Sending a low-level signal to
Fire Alarm input, “Always locked” mode is activated, in which the swing panels get closed
(Sect. 5.3.2).
Note:
Use 1 kOhm resistors connected to + 3,3 V voltage plane to generate a high-level signal on
all input contacts (Unlock A, Stop, Unlock B, Fire Alarm).
Control element is to provide the following characteristics of the signals:
control element – relay contact:
minimum commutated current ............................................................................. max 4 mA
closed contact resistance
(regarding connection cable resistance) ....................................................... max 200 Ohm
control element – open collector output layout:
closed contact voltage (low level signal, on the control board input) .................. max 0.8 V
16

ST-01 Speed gate, STD-01 Double-sided section
Figure 10. Control elements of the external device – normally open relay contact
Figure 11. Control elements of the external device – open collector output layout
5.2.6 Control modes
There are two speed gate control modes – pulse and potential. In both modes the speed gate is
controlled by sending commands (i.e. control signals combinations) to Unlock A, Stop and
Unlock B control inputs and to a special Fire Alarm control input. Control command sending
algorithm changes depending on the chosen mode.
Attention!
Change the switch positioning, remove and install jumpers on speed gate boards with de-
energized equipment.
The control mode is chosen by Pulse switch on the speed gate control board (Fig. 9). Upon
delivery the switch is in ON position, which corresponds to pulse speed gate mode.
Shift the switch into OFF position to place the speed gate into potential control mode. Control
mode will be changed after speed gate being powered.
Pulse control mode
The mode is used for speed gate operation from RC-panel, wireless remote control and ACS-
controller with the outputs supporting pulse control mode. Speed gate operation at pulse control
mode is described in Table 7.
Control signal duration at sending control command to control inputs is to be not less than 100 ms.
The initial passage waiting time is 8 seconds and it is independent of control signal (pulse)
duration.
Control command sending algorithm, which is a combination of control signals, is given in
Appendix 1. A control command is an active front of the control signal (signal shifting from high
level to a low level) at any of the control inputs (Unlock A, Unlock B and Stop), in case there are
corresponding signal levels at other inputs.
Note:
Push the corresponding button on RC-panel to send control signals from the RC-
panel / WRC to the signal active front. Pressing the button corresponds to the low level of
the signal; non-pressing the button corresponds to the high level of the signal.
17

Assembly and Operation Manual
Potential control mode
The mode is used for speed gate operation with ACS-controller. The outputs of the ACS-controller
are to support potential control mode. Speed gate operation in potential control mode is described
in Table 8.
Control signal duration at sending control command to control inputs is to be not less than 100 ms.
The passage waiting time is equal to control signal duration, i.e. that if by the moment of passage
completion in the permitted direction, there is a low-level signal at the input of this direction, the
speed gate remains open in this direction.
Control command sending algorithm is given in Appendix 2. Sending a low-level signal to Stop
input, both directions are locked for signal duration time independently of signal levels at Unlock A
and Unlock B inputs. Removing low-level signal from Stop input, the directions shift into the modes,
according to signal levels at Unlock A and Unlock B inputs.
Note:
When the speed gate is operated from the ACS, high level of the control signal corresponds
to the open contacts of the controller output relay or to the closed output transistor. Low
level of the control signal corresponds to the closed contact of the controller output relay or
to the open output transistor.
5.2.7 Speed gate operation algorithm
Speed gate operation algorithm in pulse control mode in case of single passage in one of the
directions:
1. A command (control signals combination) for single passage performance in one of the
directions is sent from the control device (RC-panel, WRC, ACS-controller) to the control board
inputs.
2. The microcontroller on the control board processes the received combination of signals and
creates a command for the swing panels motor drive to open the passage. The Time of
holding in unlocked state (8 seconds by default) countdown begins.
3. The speed gate swing panels open in the chosen direction. The user can pass through the
speed gate in the chosen direction.
4. Any movement detected in the passageway is registered as a completed passage. PASS A or
PASS B relay output, corresponding to the passage direction, is activated for 80 ms. User’s
location in the passageway is monitored by the intrusion detectors.
Note:
In order to prevent contact with the swing panels, the speed gate is equipped with the
danger zone detection. When user enters the danger zone, the swing panels moving
(opening or closing) is blocked. Danger zone range varies depending on the swing panels
dimensions.
5. After the user passes through the open swing panels he gets into a safe zone (zone, in which it
is impossible to get in contact with the swing panels) and the control board microcontroller
sends a command for the motor drive to close the swing panels. The swing panels get closed.
6. If at the moment of passage performance by the first user, another user’s passage has been
authorized in the same passage direction, the swing panels will not get closed and the new
user will be able to follow the first one.
7. If at the moment of passage performance, another user’s passage has been authorized in the
opposite passage direction, then after the first user’s passage completion the swing panels
will be closed and open in the opposite direction for the second user to pass.
Note:
In order to increase throughput rate, arrangement of separate passage lanes for each
direction is recommended. Passage directions for each passage lane can be displayed on
the front-end indication blocks.
8. If the user does not enter the passageway during the Time of holding in unlocked state, the
swing panels will close the passage lane.
18

ST-01 Speed gate, STD-01 Double-sided section
9. After the passage is completed and the swing panels are closed, the speed gate is ready for
another passage.
In potential speed gate control mode, the control signal can be released after receiving a signal
from PASS output for the same direction.
5.3 Operating devices
Speed gate operation can be performed through the following devices: RC-panel / WRC; ACS-
controller, Fire Alarm device. These devices can be connected to the speed gate separately,
simultaneously or in any combination with each other.
In case several operating devices are connected simultaneously there can be a control signal
overlap. In this case speed gate will operate according to the command, generated by the signal
combination (Appendixes 1 and 2).
5.3.1 RC-panel connection
RC-panel is connected with a flexible multicore cable to Unlock A, Stop, Unlock B, Led A,
Led Stop, Led B, Sound and GND contacts of the X2 terminal block according to the speed gate
connection layout (Fig. 18).
Figure 12. Standard RC-panel orientation regarding speed gate sections
Note:
WRC is connected to Unlock A, Stop, Unlock B and GND contacts of the X2 terminal block.
Power supply of the WRC is connected to +12V contact of the X3 terminal block.
Standard RC-panel orientation regarding sections is stated in Fig. 12. If the operator’s workspace
is located on the opposite side regarding Master section, it will be more convenient to change the
RC-panel wires, which are connected to Unlock A and Unlock B contacts, as well as Led A and
Led B respectively (Table 4).
Table 4. Connection of RC-panel cable wires to the X2 connector block
RC-panel orientation
№Contact Standard Reverse
1 GND black black
2 Unlock A white green
3 Stop blue blue
4 Unlock B green white
5 Led A yellow red
6 Led Stop orange orange
7 Led B red yellow
8 Sound brown brown
19
Other manuals for ST-01
1
This manual suits for next models
1
Table of contents
Other PERCo Other manuals
Popular Other manuals by other brands

Rand McNally
Rand McNally HD 100 user manual

GRASS VALLEY
GRASS VALLEY AURORA 7 - ARCHIVE AND RESTORE WORKFLOW Application note

Elaflex
Elaflex EK 043 Assembly manual

Novatek
Novatek REV-201? operating manual

Blue Ox
Blue Ox BX1508 installation instructions

Downee
Downee Sprint Gate Solar Series Install manual