PerfectSense PS-PCL24-R User manual

Infra re d R a nge
Range setting
Full CCW = min.(OFF)
Full CW = max.
Factory Default
Delayed-OFF time
30sec 5min 10min 20min 30min
Full CCW = min.(30 sec.)
Full CW = max.(30 min.)
Factory Default
Daylight Sensor
20 FC 40 FC 80 FC 160 FC 320 FC
Full CCW = Lights stay OFF
Full CW = Lights always turn ON (NO daylight override)
Factory Default
DETECTION AND ACTIVATION:
When a person enters a room, the sensor detects major body motion
and turns the light on. The light is kept on even as smaller body
movement is detected. This sensor’s detection sequence logic (DSL)
minimizes false triggering by continuously analyzes the motion
detection signal and adjusts internal operation to maximize the
and electrical noise.
OPERATION MODE ADJUSTMENT
SETTINGS:
(Fig. Operation control console)
All aspects of sensor operation can be adjusted here
1. Set the daylight sensor knob to fully counter clockwise (lowest level)
3. Turn the daylight sensor knob clockwise until the light turns on.
5. This will be the setting
AB
Switch Function
Settings
Off On
Bank A
A1
A2
A3
A4 Walk-Thru / Normal Walk-Thru Enabled Normal Occupancy
Bank B
B1 Daylight Sensor Enabled Disabled
B2 LED Indicator Enabled Disabled
B3 Test Mode Off-On-Off (Toggle Enter/Exit)
B4
Not Used
Not Used
Not Used
Not Used
DESCRIPTION:
Sensor designed to work with any power pack, to automatically control
lighting in standard and cold weather applications. This sensor utilizes
an industry leading 8-element Infrared Detector for superior minor
motion detection while combining with a lens that provides major
motion detection up to 2000 sq. ft. at a standard 9 ft. mounting height.
The sensor operates in climates down to -40° Fahrenheit or Celsius. Dual
Form C Relays are present on the sensor to allow for integration to
NexLight’s 2-wire system and HVAC/BMS Systems. The sensor turns the
lights on and keeps them on while occupancy is detected and will turn
There is a daylight sensor built into the sensor to allow for ambient light
override functionality. If the ambient light level in the room is at a
this setting is used, the controlled lighting load will only turn on if the
ambient light present is less than the desired setting.
INSTALLATION:
See the back of this installation manual for installation instructions. The
sensor is fully operational after 30 seconds of powering up the device.
OPERATION OF SENSOR
Delayed-OFF Time: The sensor is designed to turn the lights OFF if no
black twist knob designated for timer inside the control console. Depen-
dent upon environmental conditions and occupancy patterns, the
adapting patterns will modify the delayed-OFF time to match the
parameters of each installation.
Walk-Through Mode: The walk-through feature is useful when a room is
momentarily occupied, such as a storage room. When a person enters
the room, the lights will turn on and stay on for 2.5 minutes. After 2.5
Scenario A: If motion is detected within 10 seconds of the lights shutting
Scenario B: If no motion is detected within 10 seconds of the lights
it sees detection the lights will turn on for 2.5 minutes.
Daylight Sensor: To enable daylight sensor operation, set Dip Switch 1
in Bank B to OFF. This puts the sensor in a stand-by mode when the
natural light level exceeds the selected Foot Candles (FC) level inhibiting
the lights from turning ON.
LED Operation: The Sensor has two LED indicators that, when enabled,
has been detected by Infrared Technology.
Infrared Adjustment- For maximum range, set fully clockwise (CW). If
reduced range is required, then turn counterclockwise (CCW) and test
Delayed-OFF Time Adjustment: Each time motion is detected, the load
remains activated for a pre-set time, which is set by the Delayed-OFF
Time Adjustment, The fully CCW setting (30 seconds) can be used for
testing. The fully clockwise setting is 30 Minutes. If motion is detected
during the ON time, then the load remains activated until the full ON
time has passed since the latest motion detection.
Daylight Sensor Adjustment: This level needs to be set in a room where
natural light is at the desired level for the lighting load to not be turned
on. The sensor will still see motion (indicated by the red LEDS)
Test Mode: This mode is used to set the Delayed-OFF Time to 5 seconds for
while in test mode.
1. Ensure Power is On
2. Remove the cover from the Operation Control Console
defaulted to the OFF position.
4. To enter Test Mode, move the switch from OFF to ON and then back to
OFF. IF B3 is already in the ON position, test mode can be entered by just
moving it back to the OFF position.
Notes for Test Mode:
TOP VIEW
Field of view intersection with floor (Top view in feet 9 foot mounting height)
5 10 15 20 25 30
30 25 20 15 10 5 0
(ft)
5 10 15 20 3030 25 20 15 10 5 0
SIDE VIEW
9
0 14 2121 14
0
DETECTION AREA
TESTING THE SENSOR
Motion detection by the HDIR sensor will turn ON the lights as well as
keep them ON. When motion is not detected, the lights will turn OFF
after the delayed-OFF time.
1. The Delayed-OFF Time will remain in the 5 second test mode for 15
minutes. It will then automatically reset to the Delayed -OFF Time setting
test mode.
2. To manually take the sensor out of the test mode, move switch B3 from
OFF to ON and back to OFF again.
Hot (Black)
Neutral (White)
Load
Black
Blue
Blue
White
Black
White
Line
120/277/347VAC
60Hz
(typical power pack shown wire color may vary)
Red (24V+)
Blue (CTL)
Black (24V-)
Prepare and connect wires
1/2"
(1.3 cm)
Strip wire
(measure bare wire here)
Cut
(if necessary)
for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
INSTALLATION INSTRUCTIONS
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH;TURN OFF POWER
at circuit breaker or fuse and test that power is before wiring!
power at
circuit breaker
Option B. Junction box
1. Use two #8 32 screws (not supplied) to fasten the base
ring tothe ceiling.
#8-32 Screws
(not supplied)
Octagon Box
4" x 1 1/2" deep
Low-Voltage
Wires
Insert wires intocorrect terminalblocks and tighten.
Be sure to double check correct wiring connections!
Power
Pack
Wiring to power pack
By masking sections,
you can block hallway traffic
Mask
Masking is not required in a corner mounting application.
Select mounting location
Use the included PIR Mask
when sensor location may
cause false ON’s due to
(For best results mount at least 6 feet away from air vents)
1
Option C. Base ring w/ mounting anchors
Low-Voltage Wires
Wallboard
Ceiling
Sensor
Base Ring
Sensor Base
Mounting Screws
(2 places)
Sensor Front Cover
Mounting Anchors
1. cut 2” hole in ceiling
2. mount sensor
2 in
5
2 3 4
Included Parts List:
Sensor (1) Base mounting ring (1)
Wall Anchors (3) Spring mounting clip (2)
PIR detection Mask (1) 7/8” Wall anchor screw (3)
Tools required for install:
Slotted/Phillips Screwdriver Wire Stripper
Pencil Wire Cutters
Hole Saw
FCC COMPLIANCE STATEMENT:
This device complies with part 15 and part 18 of the FCC rules. Operation is subject to the following two conditions: (1) This device must not
cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
WARNINGS AND CAUTIONS:
•To be installed and/or used in accordance with appropriate
electrical codes and regulations.
• If you are unsure about any part of these instructions,
• Sensors must be mounted on a vibration free surface.
• All sensors must be mounted at least 6 feet away from air vents.
• Do not mount sensors closer than 10 feet from each other.
• Do not touch the surface of the PIR lens. Clean outer surface only.
2. Align the sensor’s two eyelets with the base ring’s two hooks.
3. Press the sensor onto the base ring.
5
Option A. Drop ceiling w/ mounting clips
A. remove mounting ring
3.375 in
Low Voltage Wires
Wallboard
Ceiling
Terminal Block
Connections
Mounting
Clips
B. install clips
C. cut 3.375” hole
in ceiling
D. mount sensor
2
11
5
NORMALLY CLOSED
NORMALLY OPEN
COMMON
NORMALLY OPEN
+
_
CONTROL
COMMON
NORMALLY CLOSED
CLOSED
NORMALLY
COMMON
NORMALLY
OPEN
NORMALLY
COMMON
NORMALLY
OPEN
CLOSED
24 Vdc

Other PerfectSense Accessories manuals

PerfectSense PS-HC24-R User manual

PerfectSense

PerfectSense PS-HC24-R User manual

PerfectSense PS-P24-CM User manual

PerfectSense

PerfectSense PS-P24-CM User manual

PerfectSense PS-PCL24-R User manual

PerfectSense

PerfectSense PS-PCL24-R User manual

Popular Accessories manuals by other brands

iMuto Taurus X6S user manual

iMuto

iMuto Taurus X6S user manual

Sparehand Systems Glacik G-505 quick guide

Sparehand Systems

Sparehand Systems Glacik G-505 quick guide

Huawei DTSU666-HW quick guide

Huawei

Huawei DTSU666-HW quick guide

ABB 5526A-A02359 manual

ABB

ABB 5526A-A02359 manual

Waterpik Express user manual

Waterpik

Waterpik Express user manual

PCB Piezotronics IMISensors Echo 670A01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMISensors Echo 670A01 Installation and operating manual

Eaton CWPD Series Wiring and installation manual

Eaton

Eaton CWPD Series Wiring and installation manual

Hive Window or Door Sensor user guide

Hive

Hive Window or Door Sensor user guide

Sunjoy A601002201 Assembly instruction

Sunjoy

Sunjoy A601002201 Assembly instruction

FrSky FSH-01 instruction manual

FrSky

FrSky FSH-01 instruction manual

Peg-Perego Navetta Elite Instructions for use

Peg-Perego

Peg-Perego Navetta Elite Instructions for use

QOLSYS IQ MINI DW S Series Quick install guide

QOLSYS

QOLSYS IQ MINI DW S Series Quick install guide

Panlux H-108/M instructions

Panlux

Panlux H-108/M instructions

VPI VOPEX-SV-2-LC installation guide

VPI

VPI VOPEX-SV-2-LC installation guide

Electro-Voice MI-1 Architects and engineers specifications

Electro-Voice

Electro-Voice MI-1 Architects and engineers specifications

SOMFY Oximo WireFree Battery Stick instructions

SOMFY

SOMFY Oximo WireFree Battery Stick instructions

Rohde & Schwarz R&S NRQ6 user manual

Rohde & Schwarz

Rohde & Schwarz R&S NRQ6 user manual

Siemens SIMATIC RF300 System manual

Siemens

Siemens SIMATIC RF300 System manual