Perrin & Rowe Country Kitchen Alsace 4770 User manual

Alsace Aqui ta ine Pi cardie
4770 4771 4741 4746 4761 4766
4775 4776
9.20771*
9.07720
9.25384
9.17793*
9.13362
(Rinse Version Only)
9.18380*
9.13145/Hot
9.13146/Cold
9.28400
9.24194*
9.12760*
9.26760*
9.26400
9.28401
(Rinse Version Only)
9.03860 Non-Rinse
9.03865 Rinse
For maintenance and repairs, we recommend you employ a Registered Plumber.
Before ordering spare parts, determine the correct reference number from the
exploded diagram. Quote this number, and where appropriate, the colour of
your tap.
9.20771*
9.07720
9.13362
(Rinse Version Only)
9.25384
9.17793*
9.26400
9.28400
9.03860 Non-Rinse
9.03865 Rinse
9.12745*
9.26760*
9.13841
9.24745*
9.01340*
9.18380*
9.28401
(Rinse Version Only)
For written details of the product guarantee, please contact us at the address
shown below.
For spares, please contact your local distributor or Perrin & Rowe
Perrin & Rowe is a registered trademark.
Gateway XIII, Ferry Lane, Rainham, Essex, RM13 9JY, United Kingdom.
T +44(0)1708 526361 E [email protected] W www.perrinandrowe.co.uk
Guarantee
pare Parts
* p eci f y Col ou r
9004740
9.26400
9.28401
(Rinse Version Only)
9.21370*
9.12795*
9.13145/Right
9.13146/Left
9.26760*
9.24194*
9.18380*
9.18380*
9.03700
9.18770*
9.28400
9.30700
9.20771*
9.07720
9.25384
9.17793*
9.03865
(Rinse Version Only)
9.01795*/Cold
9.01795*/Hot
9.12795*
9.13146
9.13362
(Rinse Version Only)
9.19426
9.27775*
9.18380*
9.18425*
9.28426
Picardie
Rinse
Alsace Aquitaine
T he Co un tr y Ki tch en Co ll ec ti on
S p a r e P a r t s
T he Co un tr y Ki tch en Co ll ec ti on
I n s t a l l a t i o n & U s e r G u i d e
9.01775*

Alsace idevalve Assembly
- Refer to Figure 2.
8) The side valve assemblies require a 30mm diameter
hole through the counter-top surface.
9) Undo and remove cover, handle, rosette, base ring and
base seal. Screw backnut and washer fully onto side
valve shank.
10) From underside pass shank through the hole in the
counter-top then place base ring and seal over shank,
screw rosette with base seal onto shank until the
thread can be seen above the rosette.
11) Ensure the connection for flexible hose is facing the
nozzle and tighten backnut and fibre washer up to the
underside of the counter top by hand to stop sidevalve
from rotating.
12) Connect flexible hose from nozzle to sidevalve outlet.
Screw the cover and handle onto the sidevalve
ensuring that the handle is correctly aligned. If not,
remove and turn the plastic vernier insert a few splines
until the correct alignment has been achieved.
13) Unscrew the rosette until it meets the cover and fully
tighten backnut and fibre washer up to underside of
counter-top.
14) Connect the Hot & Cold water supplies to the side
valve inlets.
15) Important -Check that flexible hoses are not twisted or
kinked as this will restrict the flow.
Rinse Assembly - Refer to Figure 2, 3, 4.
16) The rinse units require a 30mm diameter hole through
the surface they are to be installed on.
17) Assemble rinse unit socket to the counter-top ensuring
the base ring and seal are in place under body and the
fibre seal is above the backnut.
18) Thread the tapered end of the rinse flex to the Rinse
unit ensuring the rubber seal is in place between them.
19) Pass the other end of the flex down through the
socket, and screw the externally threaded end to the
remaining hose at the base of the tap. ee Figure 2, 3,
4.
Before Use
20) Turn on the Hot and Cold supplies to the tap.
21) Carefully check the installation for leaks.
22) If further building work is to be carried out in the
vicinity, cover the tap with a cloth or towel to avoid
damaging the finish.
23) Please ensure that the installation complies with the
local water supply bye-laws.
Congratulations on the purchase of your Perrin & Rowe
Kitchen Tap.
Correctly installed and with sensible care, it will give many
years of trouble free service.
Before you proceed... We recommend you engage the
services of a registered plumber to install this product.
Read the instructions and diagrams in this leaflet
carefully.
Preparation
This range of Perrin & Rowe kitchen taps features a spout
that allows hot and cold water to mix before discharge.
Check valves are supplied in the inlets of all UK Country
taps. Rinse products are supplied with WRAS listed double
check valves.
1) Flush the plumbing system before installing the tap.
This is to avoid plumbing residues clogging the NRV’s,
aerator, or possibly damaging the ceramic valves. This
is especially important where extensive plumbing work
has been carried out.
Check List
l
Temperature of the hot water supply does not exceed
85 C.
l
Recommended minimum water supply pressure - 1 bar.
l
Recommended maximum water supply pressure - 5 bar.
l
Ideal performance obtained with equal hot & cold
pressures.
Aquitaine, Picardie & Alsace Centrebody Assembly
- Refer to Figure 1.
2) Hot supply should be on the left when viewed from the
front of the fitting.
3) Aquitaine - ever should be on the right when viewed
from the front of the fitting. Hole centre a minimum
distance of 65mm from wall. The Hot supply should be
at rear of the mixer.
4) Monobloc mixers and Alsace centrebody require a
35mm diameter hole through the surface they are to
be installed on.
5) Insert the flexible connections through the hole
ensuring that the base ring and seal are in place
between the mixer and
mounting surface.
6) For sheet metal sinks,
use sink support where
provided
7) From the underside of the
counter-top, place the
clamp plate on securing
stud and using the box
spanner supplied, put
fixing nut in spanner and
tighten until mixer is held
firmly in position.
ee Figure 1.
35mm
Hole
Diameter
Base Seal
Nut
Box Spanner
Clamp Plate
Securing Stud
230
60ø 60 ø
143
127
200
270
76
30ø Hole 35ø Hole
Check Valve
Housing
G
1/2"
15mm
45 Max
HOT IN COLD IN
G
1/2"
150-400 Centres
230
270
35ø Hole
30ø Hole 30ø Hole
9540 Max
60
200
143
60ø60ø60ø
15mm
Rinse Version
Only
60ø
143
230
60ø
170
210
280
88
35ø Hole30ø Hole
G
1/2"
15mm
Check Valve
Housing
45 Max
Figure 2. Installation of Alsace Mixer Figure 4. Installation of Picardie Mixer
Figure 3. Installation of Aquitaine Mixer
Figure 1. Installation of Tap
The Coun tr y Ki tch en Collection
Introduction & Installation
Operation
Ceramic disc valves are fitted as standard. Flow from FU Y
OFF to FU Y ON is achieved by rotating the handles a
quarter turn.
The Aquataine mixer temperature is controlled by rotating
the lever forwards or backwards, in line with the body of
the tap, to adjust Hot and Cold. The flow of water is
increased by pushing the lever towards the body of the
tap.
Care & Maintenance
Occasional cleaning with warm soapy water, followed by a
polish with a soft cloth is all that is required to keep the
plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads
to clean the tap. You will damage the plated finish and
void your guarantee.
The aeration device fitted to the hot/cold water outlet may
need occasional cleaning, especially in hard water areas.
This is accomplished by unscrewing the outlet in an anti-
clockwise direction, dismantling and leaving the inner
screen mesh immersed overnight in vinegar or lemon juice.
DO NOT use chemical descaling liquids for this purpose.
The Coun tr y Ki tch en Collection
I n s t a l l a t i o n / C a r e & M a i n t e n a n c e
This manual suits for next models
8
Other Perrin & Rowe Bathroom Fixture manuals
Popular Bathroom Fixture manuals by other brands

for Living
for Living 063-6094-0 Assembly instructions

Helvex
Helvex 158 installation guide

Fontana Showers
Fontana Showers FS1320D installation instructions

agape
agape ACER1082F BJHON2 Series Assembly instructions

Brizo
Brizo Sotria 65351LF Series quick start guide

FrontLine
FrontLine AQUAGLASS Plus installation instructions