Valve Body
Backnut
Base Seal
Shower Outlet
Nipple
Banjo
Connection
HOT IN
Cover & Handle Base Ring
Rosette
COLD IN
19/16"
MAX
13/8"
ø
Hole
13/8"
ø
Hole
13/8"
ø
Hole
3/4" NPT
Rough installation cap
provided for centerbody
An extra backnut is supplied
for rough
installations
Nut
Extension
Hose - 1m
HANDSHOWER SOCKET DETAIL
Rosette
Tapered
Bushes
Handshower
Flex - 2m
Fig 1.
Installation of Faucet
Before you proceed...
We recommend you engage the services
of a registered plumber to install this product.
Read the instructions on this leaflet carefully.
Congratulations on the purchase of your Perrin & Rowe Bathroom Faucet.
Correctly installed and with sensible care, it will give many years of trouble free service.
U.3245L U.3246X U.3248L U.3249X U.3737L U.3738X
U.3745L U.3746X
4
4
H
H
o
o
l
l
e
e
T
T
u
u
b
b
W
W
i
i
d
d
e
e
s
s
p
p
r
r
e
e
a
a
d
d
s
s
PREPARATION
Flush the plumbing system before installing the mixer faucet. This is
to avoid plumbing residues clogging the aerator, or possibly
damaging the ceramic valves. This is especially important where
extensive plumbing work has been carried out.
The Hot supply should be on the left when viewed from the front of
the fit ting.
It is essential to leave adequate access to the underside of the bath
to allow for maintenance.
CHECK LIST
! Temperature of the hot water supply does not exceed 185 F !
! Recommended minimum water supply pressure - 15 psi !
! Recommended maximum water supply pressure - 70 psi !
! Ideal water pressure is 55psi
! Ideal performance obtained with equal hot & cold pressures !
ASSEMBLY - Refer to Fig 1.

Assemble the nozzle by placing the shank through the hole in the
worksurface en sur ing that the base ring & seal are in place.
Place backnut onto shank and tighten to underside of worksurface.
Fit banjo connection onto shank using shower outlet nipple, taking
care not to overtighten.
Assemble handshower socket to worksurface ensuring base seal is in
place under body.
Place flex through the socket, nut end first, to leave tapered end
showing.
Assemble the two tapered bushes (larger internal diameter to top)
then push into handshower socket.
Place rosette over flex and assemble to socket.
Assemble handshower to tapered end of flex.

Fit nut end of hose to outlet. To allow servicing of the handshower
flex, the hose should allow the connection to be pulled up through
the handshower socket. If required extend the reach by connecting
to the banjo with a copper connection.

Fit handshower flex to hose.

To assemble side valve, ensure the brass backnut and
washer are in place on the valve body, then from the underside of
worksurface, push the valve body through the hole. Assemble
rosette as shown so that the valve body thread shows at top.

Ensure that the connection for the flexible hose is facing towards
the nozzle.

Assemble cover & handle onto the valve body ensuring that it is
aligned properly. If it is not, re move and turn a few splines until
correct align ment achieved.

Screw the rosette up to the underside of cover.

Repeat this procedure for the second side valve.

Make the connections between the side valves and the nozzle.

Tighten the brass backnut and washer to the underside of the
work surface.

Connect the side valves to the nozzle using the flexible hoses.
Assemble and connect pop-up waste.

Ensure all connections are firmly tightened.

Connect Hot & Cold water supplies to side valve inlets.
BEFORE SE
Carefully check the installation for leaks.
If further building work is to be carried out in the vicinity, cover the
faucet with a plastic bag to avoid damaging the finish.
Please ensure that the installation complies with the local plumbing
codes.
Perrin & Rowe is a trademark of Avilion Ltd. 903245U/2 02/08
NOTE:
To utilize the rough installation cap it is necessary to remove the top
seating cage, please follow the first 5 points of the Diverter
Replacement section.
SPARE PARTS AND SERVICE
3 Parker
Irvine
CA 92618
(714) 557-1933
OPERATION
Ceramic disc valves are fitted as standard to this mixer faucet. Flow from
FULLY OFF to FULLY O is achieved by rotating the handles a quarter turn.
Diverting action is achieved by pulling up on the diverter knob. Higher water
pressures may make the diverting action difficult.
CARE & MAINTENANCE
Occasional cleaning with warm soapy water, followed by a polish with a soft
cloth is all that is required to keep the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the
faucet. You will damage the plated finish and void your warranty.
The aerator at the outlet of the spout may need occasional cleaning. This is
accomplished by unscrewing the outlet in an counter-clockwise
direction, dismantling and leaving the inner screen mesh immersed
overnight in vinegar or lemon juice. DO NOT use chemical descaling
liquids for this purpose. Rinse thoroughly in clean water and re install.
DIVERTOR REPLACEMENT
Unscrew the divertor knob from the spindle by lifting the knob and
gripping the flats on the spindle with a 5mm spanner, then unscrew.
Undo the screw in the back of the nozzle using the hexagon key
provided.
Lift the nozzle off base ring and shank.
Unscrew top seating cage and remove.
Replace diverter plate sub-assembly’.
Reassemble the nozzle, check fitting carefully for leaks.
Reassemble the divertor knob.
HANDLE VARIANTS
Both porcelain and solid levers are included with
U.3248L U. 3737L and U.3745L
models.
HOW TO CHANGE
DE
F
A
C
B
A
BE
11))Unscrew lever bolt AAfrom lever ball BBby
hand.
22))Remove metal lever insert CCand seal DD.
33))Place one of the replacement seals EEonto
lever bolt AAand slide to the end. Place
porcelain lever insert FFonto lever bolt AA
and slide to the end of the bolt.
44))place the other replacement seal EEonto
lever bolt AAand slide to the end of the
porcelain lever insert.
55))Screw lever bolt and porcelain lever insert
assembly back into lever ball BBand screw
down tightly by hand

This manual suits for next models

13

Other Perrin & Rowe Bathroom Fixture manuals

Perrin & Rowe Country Kitchen Alsace 4770 User manual

Perrin & Rowe

Perrin & Rowe Country Kitchen Alsace 4770 User manual

Perrin & Rowe Georgian U.3783L Operation manual

Perrin & Rowe

Perrin & Rowe Georgian U.3783L Operation manual

Perrin & Rowe Parabola PB5PN User manual

Perrin & Rowe

Perrin & Rowe Parabola PB5PN User manual

Popular Bathroom Fixture manuals by other brands

Sanela SLU 08N Instructions for use

Sanela

Sanela SLU 08N Instructions for use

Triton OMNICARE GEOSRP81 manual

Triton

Triton OMNICARE GEOSRP81 manual

Panasonic DH-4US1 Operating and installation instructions

Panasonic

Panasonic DH-4US1 Operating and installation instructions

Hans Grohe Metropol E 14470000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Metropol E 14470000 Instructions for use/assembly instructions

OVE NOAH installation manual

OVE

OVE NOAH installation manual

Victorian Plumbing Arezzo Fitting instructions

Victorian Plumbing

Victorian Plumbing Arezzo Fitting instructions

Excellent KROTOS AREX.8025CR installation manual

Excellent

Excellent KROTOS AREX.8025CR installation manual

Rubi KASKAD RKA11B Installation

Rubi

Rubi KASKAD RKA11B Installation

OVE LELIO I 60 installation manual

OVE

OVE LELIO I 60 installation manual

LF ORIGIN 21 FW0AC015CP installation instructions

LF

LF ORIGIN 21 FW0AC015CP installation instructions

Taiji HOTCABI HC-38 instruction manual

Taiji

Taiji HOTCABI HC-38 instruction manual

MAAX 137420 installation instructions

MAAX

MAAX 137420 installation instructions

Hans Grohe Ecostat Comfort 13114 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Ecostat Comfort 13114 Series Instructions for use/assembly instructions

Lefroy Brooks C1-1020 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks C1-1020 Installation, operating, & maintenance instructions

CRM Solar Shower user manual

CRM

CRM Solar Shower user manual

Grohe TECTRON 37 421 Assembly instruction

Grohe

Grohe TECTRON 37 421 Assembly instruction

Kohler K-8034 installation guide

Kohler

Kohler K-8034 installation guide

Ribimex Ribiland PR/UB.1405 User and maintenance manual

Ribimex

Ribimex Ribiland PR/UB.1405 User and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.