Phason NVC-2-12 User manual

This manual suits for next models

1

Other Phason Controllers manuals

Phason SEC-HD User manual

Phason

Phason SEC-HD User manual

Phason Natural Ventilation Control User manual

Phason

Phason Natural Ventilation Control User manual

Phason MSC-4 User manual

Phason

Phason MSC-4 User manual

Phason TVS User manual

Phason

Phason TVS User manual

Phason FC Series User manual

Phason

Phason FC Series User manual

Phason PLUS Series User manual

Phason

Phason PLUS Series User manual

Phason FHC-1D User manual

Phason

Phason FHC-1D User manual

Phason PEC User manual

Phason

Phason PEC User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Phason
3344000
0
Natu
r
T
he Nat
u
provides
automati
c
and heat
e
Model
N
V
Controlli
n

Whe
n
the
N

Whe
n
the c
u
durat

A
fte
r
then
e
depe
n
Controlli
n

Whe
n
switc
h

Whe
n
switc
h
Quic
k
A
ccess
o
A
larm
c
A
larm
s
Close
d
Close
o
Control
Control
Curtain
Curtain
Curtain
Factor
y
0
r
al Ven
t
u
ral Ventilati
o
extensive fl
e
c
ally control
s
e
r according
V
C-2-12
is 1
2
n
g a curtain
n
the temper
N
VC maintai
n
n
the temper
u
rtain for th
e
ion
.
r
each
Off du
r
e
ither opens
n
ding on the
n
g a heater
n
the temper
h
es the heat
e
n
the temper
h
es the heat
e
k
referenc
e
o
ries and kit
s
c
onnection....
ettings overv
d
uration.........
o
ff (idle) dura
t
layout .........
overview .....
machine co
n
set point......
settings ove
r
y
defaults ......
t
ilation
o
n Control (
N
e
xibility for y
o
s
the temper
a
to your pro
g
2
VDC-pow
e
machine
ature is
w
ith
i
n
s the curtai
n
ature rises a
b
e
On duratio
n
r
ation
, the N
V
or closes th
e
temperatur
e
ature is belo
w
e
r on.
ature is abo
v
e
r off.
e
s
...........21
..............7
iew ......13
............11
ion ......11
..............5
..............3
n
nection.6
............10
r
view......9
............18
Contro
N
VC) is a f
u
o
ur curtain
o
a
ture in a ro
o
g
rammed set
t
e
red; model
N
i
n the
Idle b
a
n
position.
b
ove the
Idle
n
, and then
p
V
C checks t
h
e
curtain (fo
r
e
.
w
the
Heat s
e
v
e the
Heat s
e
Features....
.
Firmware v
e
Heater con
n
Heater set
p
High alarm
.
Hysteresis.
.
Idle band...
.
Low alarm .
.
Manual ove
Menu.........
.
Mounting ..
.
l, 12/2
4
u
lly program
m
o
r awning co
n
o
m by opera
t
t
ings.
N
VC-2-24
i
s
2
a
nd
of the
S
e
band
, the
N
p
auses for th
e
h
e temperat
u
r
the preset
d
e
t point
, the
e
t point
, the
N
.
....................
.
e
rsion ...........
.
n
ection.........
.
p
oint .............
.
.
....................
.
.
....................
.
.
....................
.
.
....................
.
rride mode ..
.
.
....................
.
.
....................
.
4
V
m
able contr
o
ntrol needs.
T
t
ing a curtai
n
2
4 VDC-po
w
e
t point
,
N
VC opens
e
Off
u
re and
d
uration),
NVC
NVC
.......... 2
........ 19
.......... 6
........ 12
........ 14
........ 12
........ 11
........ 14
........ 16
.......... 4
.......... 6
O
O
P
R
R
T
T
T
T
o
ller that
The NVC
n
machine
w
ered.
O
pen duratio
n
O
pen off (idle
)
P
ower conne
c
R
ain sensor..
.
R
atings.........
.
T
emperature
p
T
emperature
t
T
emperature
u
T
roubleshooti
n
...................
)
duration ....
c
tion.............
.
....................
.
....................
p
robe...........
t
est mode ....
u
nits.............
ng................
1
..10
..11
....8
..14
....2
....7
..15
..14
..21
Natural
V
2
Featu
r

A
uto
m
w
ith
e
-13 t
o

Prog
r
the o
p
1 to
9

Prog
r
1.0 t
o

Prog
r
0.3 t
o

Prog
r
alar
m

Two
c

Heat
e
Electr
i

Input

Ope
n

Alar
m
V
entilation
r
es
m
atic tempe
r
e
xtended te
m
o
125°F
(
-25
r
ammable O
n
p
en and clo
s
9
00 seconds
r
ammable I
d
o
10.0°F (0.6
r
ammable h
e
o
5.0°F (0.2
t
r
ammable H
i
m
s
c
urtain relay
s
e
r control re
l
i
cal rati
n
power
n
/close/heat
m
relay
If you are
c
install pow
e
Control
r
ature-based
m
perature ra
n
to 51.7°C)
n
and Off d
u
s
e relays
(up to 15 mi
n
d
le band
to 5.5°C)
e
ater Hystere
t
o 2.8°C)
i
gh and Lo
w
s
(
one open,
l
a
y
n
gs
M
o
M
o
r
elays
12
15
1/
2
0.
4
0.
2
c
onnecting
a
e
r contactor
control,
n
ge
u
rations for
n
utes)
sis
w
temperatur
e
one close)
o
del NVC-2-1
o
del NVC-2-2
4
A at 30 VD
C
A at 120/2
3
2
HP at 120
4
A at 125 V
A
2
A at 125 V
A
a
ny equipm
e
s. For more
e

A

F

F

P

M

P

T
5

R

R
w

L
2
12 VD
C
4
24 VD
C
C
3
0 VAC, resis
VAC, 1 HP
a
A
C; 2 A at 3
0
A
C; 1 A at 3
0
e
nt that exc
e
information
A
larm relay
(
F
our-button
F
our-charac
t
P
rogrammi
n
M
anual over
P
ower-failur
e
T
emperatur
e
5
00 feet
R
ain Sensor
R
ugged encl
o
w
ater resista
n
L
imited war
r
C
, 250 mA
C
, 125 mA
s
tive load
a
t 230 VAC
0
VDC, resis
t
0
VDC, indu
c
e
eds the rati
, read
Pow
e
(
for external
keypad
t
er LED dis
p
n
g and status
ride/test m
o
e
settings pr
o
e
probe, 6 fe
e
(optional)
o
sure (corro
n
t, and fire r
r
anty (two y
e
t
ive load
ctive load
ngs of the r
e
e
r contactor
s
Ph
a
2014
-
alarm syste
m
p
la
y
LEDs
o
de
o
tection
e
t extendabl
e
sion resistan
etardant)
e
ars)
e
lays, you
m
s
on page 2
2
ason
-
04-10
m
)
e
to
t,
m
ust
2
.
Phason Natural Ventilation Control
33440000 3
Becoming familiar with the NVC
Main display
The main display shows the temperature and any alarm messages. The main display is what you see
when you are not in a menu or settings display.
Here are some things to know about the main display.
When a relay is on, the status LED for that relay is lit.
When there is an alarm condition, the display flashes between the alarm message and the current
temperature. For more information about alarms, read Alarm settings and conditions on page
13.
When the control is in manual override mode:
For the curtain, the Open and Close LEDs will blink three times and then stay off for one
second.
For the heater, if the heater is ON, the Heat LED will blink three times and then stay ON
for one second; if the heater is OFF, the LED will blink three times and then stay OFF for
one second.
For more information, read Using manual override mode on page 16
Down
▪Scroll down
▪Decrease a value
Up
▪Scroll up
▪Increase a value
Select
▪Select an option
▪Accept a value
Back
▪Go back
▪Cancel changes
Alarm LED
▪Shows when there is an alarm condition
Test LED
▪Shows when test mode is active
Version LED
▪Shows the firmware version
Programming LEDs
▪Show which setting is being
displayed or programmed
Status LEDs
▪Show the status of the relays
▪Show which relay is being
controlled
Programming LEDs
▪Show which setting is being
displayed or programmed
Natural
V
4
Main
m
When yo
u
w
hich m
e
Menu ite
m
Open
Close
Heat
Alarm
Test
Version
Set point
Open on d
Open off
d
Close on
d
Close off
d
Idle band
Heat set p
High alar
m
Low alar
m
Hysteresi
s
Units
Sensor
Instal
l
V
entilation
m
enu
u
are in the
m
e
nu item is s
e
m
uration
d
uration
d
uration
d
uration
o
in
t
m
m
s
ing the
N
Read a
n
equipm
e
Read
El
e
control.
Control
m
ain menu,
t
e
lected. Pres
s
Displ
a
Cur
t
hea
t
aLa
r
tes
t
Ver
stp
t
Oo
n
Oo
f
Co
n
Co
f
ban
d
Hea
t
Hia
L
Loa
L
Hys
t
Uni
t
sen
s
N
VC
n
d follow all
e
nt to it.
e
ctrical ratin
t
he display s
h
s
Up
or
Dow
a
y
t

t

r

t

t

n

f
f
n

f
f
d

t

L

L

t
t

s

instructions
gs
on page
h
ows the me
n
n
to move t
h
Function
Select autom
a
Select autom
a
Switch the al
a
Adjust the tes
Restore the f
a
Display the fi
r
Update the fir
m
Adjust the cu
r
Adjust the cu
r
Adjust the op
e
Adjust the clo
Adjust the clo
Adjust the Idl
e
Adjust the he
a
Adjust the hig
Adjust the lo
w
Adjust the hy
s
Change betw
e
Enable the op
t
when instal
2. Do not e
x
nu items; th
e
h
rough the
m
a
tic or manual
o
a
tic or manual
o
a
rm relay on or
s
t temperature
a
ctory defaults
r
mware version
m
ware version
r
tain set poin
t
r
tain open dura
t
e
n idle duration
o
se duration
o
se idle duratio
n
e
band
a
ter set poin
t
g
h alarm tempe
r
w
alarm temper
a
s
teresis for the
e
en Fahrenheit
a
tional rain sens
ling the NV
C
x
ceed the el
e
LEDs ligh
t
m
enu items.
o
verride (open,
o
verride (on or
o
off
t
ion
n
r
ature
a
ture
heate
r
a
nd Celsius
s
o
r
C
and conn
e
l
ectrical rati
n
Ph
a
2014
-
t
up to show
close, or idle)
o
ff)
e
cting
n
gs of the
ason
-
04-10
you
Phason
3344000
0
NVC la
y
Op
e
Co
n
He
a
ga
s
DC
on
t
Te
m
Co
n
Dis
Ala
Co
n
Inp
on
US
B
rea
d
2
1
3
4
5
6
7
8
9
0
y
out
e
n and close r
e
n
necting a curt
a
ter relay term
s
-fired furnace
power termin
a
t
he model. For
m
m
perature pro
b
n
necting on p
a
play connecto
r
rm relay termi
n
n
necting an al
a
ut terminal: co
page 21.
B
connection:
c
d
Updating the
1
2
e
lay terminals:
a
in machine o
n
inal: connect a
or electric he
a
a
l: connect the
b
m
ore informati
o
b
e terminal: co
n
a
ge 7.
r
:make sure th
e
n
al: connect a
n
a
rm system on
nnect an optio
n
c
onnect a USB
m
firmware on p
a
2
3
5
connect a curt
a
n
page 6.
heate
r
or furn
a
a
ter on page 6.
b
attery cable to
o
n, read Conne
c
n
nect the temp
e
e
ribbon cable f
n
external alarm
page 7.
n
al Rain Sensor
m
emory stick t
o
a
ge 19.
5
6
4
a
in machine to
t
ce to this termi
this terminal.
T
c
ting the powe
r
e
rature probe t
o
rom the displa
y
system or sire
n
to this termina
l
o
this connecto
t
hese terminals
nal. For more i
n
T
he terminal lab
r
source on pa
g
o
this terminal.
F
y
is properly co
n
n to this termin
a
l
. For more info
r to update the
9
Natural Ve
n
. For more info
r
n
formation, rea
d
el will be 12 or
g
e 8.
F
or more infor
m
n
nected.
a
l. For more inf
rmation, read
P
firmware. For
m
7
n
tilation C
o
r
mation, read
d
Connecting a
24 VDC, depe
n
m
ation, read
ormation, read
P
hason Rain S
e
m
ore informatio
8
o
ntrol
5
n
ding
e
nsor
n,
Natural
V
6
Mounti
n

Selec
t
equi
p

Rem
o

Mou
n
into
t
Conne
c
Curtains
curtain
m
winches
.
The NV
C
air or les
s
building.
Conne
c
Connect
V
entilation
n
g the NV
C
t
a location
f
p
ment you w
a
o
ve the scre
w
n
t the enclos
t
he large hol
e
c
ting a cu
r
are usually c
o
m
achines, wh
i
C
opens and
s
air, the ide
a
c
ting a ga
s
the heater a
s
Gas furnac
indicated
o
read your f
u
Control
C
f
or the NVC
.
a
nt to contr
o
w
s from the
f
ure to a wall
e
s in each co
r
r
tain mac
h
o
ntrolled by
i
ch are some
t
closes the c
u
a
being more
s
-fired fur
s
shown in t
h
es using ho
t
o
n their nam
e
u
rnace man
Gas-fired f
u
.
Make sure
y
o
l.
f
ront cover a
using the fo
r
ner of the
b
h
ine
equipment
c
t
imes referr
e
u
rtain to let i
n
air cools th
e
nace or e
l
h
e following
d
t
-surface ig
n
e
plate, and
ual.
u
rnace
y
ou have en
o
n
d then gen
t
ur screws pr
b
ox and the
n
c
alled
e
d to as
n
more
e
l
ectric he
a
d
iagram tha
t
n
ition or a gl
require po
w
o
ugh cable a
n
t
ly lift it off.
r
ovided with
n
tighten.
a
te
r
t
matches yo
u
l
ow plug ca
n
w
er contacto
r
Electric heat
e
n
d wire to re
a
the control.
u
r applicatio
n
n
draw mor
e
rs. For mor
e
e
r
Ph
a
2014
-
a
ch the
Insert the s
c
n
.
e
current th
a
e
informatio
n
ason
-
04-10
c
rews
a
n
n
,
Phason Natural Ventilation Control
33440000 7
Connecting the temperature probe
Follow the guidelines below when installing and connecting the temperature probe.
Do not run the probe cable in the same conduit as
AC power cables
Do not run the sensor cable beside AC power
cables or near electrical equipment.
When crossing other cables or power lines, cross
them at a 90-degree angle.
Replace damaged probes as soon as possible. If there is no probe present or
working properly, the NVC displays either pd (probe damage) or ps (probe short)
and switches off the relays.
Connecting an alarm system
An alarm system can be a siren, an alarm panel, or an auto-dialer. See your alarm siren’s installation
guide for installation instructions and information about the type of system:
The descriptions for the alarm terminal are as follows: CC–common connection, CA–closed on
alarm, OA–open on alarm.
To connect an alarm system
If you are connecting the alarm system to a
network of controls and your system uses a
normally open connection (closes on alarm),
connect the system as shown in the normally open
diagram.
Join all the common (CC) connections together
and all the closed-on-alarm (CA) connections
together. The NVC alarm relays must be in parallel
with each other so any control can trigger the
alarm system when an alarm condition occurs.
Normally open system (closed on alarm)
Natural Ventilation Control Phason
8 2014-04-10
If you are connecting the alarm system to a
network of controls and your system uses a
normally closed connection (opens on alarm),
connect the system as shown in the normally
closed diagram.
Join the alarm relays in a continuous loop. The
NVC alarm relays must be in series with each other
so any control can trigger the alarm system when
an alarm condition occurs.
Connecting the power source
DC model NVC-2-12 (12 VDC, 250 mA)
DC model NVC-2-24 (24 VDC, 125 mA)
Before connecting the incoming
power, switch OFF the power at the
source.
Do not switch ON the power until
you have finished all wiring and
verified all equipment is properly
connected and free of obstructions.
Finishing the installation
1. Make sure all wires are properly connected to the correct terminals.
2. Place the cover on the control.
3. Switch on the power to the NVC; it should display ŠŠŠŠ for three seconds, the version (for
example, vƒ00) for three seconds, and then the temperature.
If the display does not light up, go back to step 1.
If the display shows an alarm message, or the LED for Alarm is flashing, press Select to
acknowledge the alarm. For a list of alarm messages and error codes, read Alarm messages
on page 13.
4. Test the equipment. For more information, read Testing and maintaining the NVC on page 15
5. Fasten the cover to the base.
Normally closed system (open on alarm)
Phason Natural Ventilation Control
33440000 9
Programming the NVC
Before you begin programming the NVC, make sure the control has power and you have
properly
connected
all equipment to the
correct terminals
.
How the curtain settings work
There are six curtain settings.
Set point – the temperature at which the curtain holds its position.
Idle band – the buffer around the set point within which the curtain holds its position.
Open on duration – the duration the curtain opens during the open cycle
Close on duration – the duration the curtain closes during the close cycle
Open off duration – the duration the curtain holds its position during the open cycle
Close off duration – the duration the curtain holds its position during the close cycle
Curtains hold their position while the temperature is within the Idle band of the Set point. For
example, if the Set point is 80°F and the Idle band is 4°F (+/- 2°), the curtain holds its position
when the temperature is between 78°F and 82°F.
If the temperature rises above the Idle band (above 82°F in our example), the curtain opens for the
Open on duration. After opening, the curtain holds its position for the Open off duration. If the
temperature is still above the Idle band, the curtain again opens for the Open on duration, and the
process repeats.
If the temperature drops below the Idle band (below 78°F in our example), the curtain closes for the
Close on duration. After closing, the curtain holds its position for the Close off duration. If the
temperature is still below the Idle band, the curtain again closes for the Close on duration, and the
process repeats.
Natural Ventilation Control Phason
10 2014-04-10
To program the Set point
Default: 70.0°F, range: –13 to 125 (-25 to 51.7°C)
1. Press Down until the display shows StPt.
2. Press Select.
The current setting (in degrees) displays and the Set point LED flashes.
3. Press Up or Down to adjust the setting and then press Select.
The change is saved and the display shows StPt.
4. Press Down to move to the Open on duration, or Back to cancel and return to the main display.
To program the Open on duration
Default: 20 seconds, range: 1 to 900 (up to 15 minutes)
1. Press Up or Down until the display shows 0on.
2. Press Select.
The current setting (in seconds) displays and the On duration LED flashes.
3. Press Up or Down to adjust the setting and then press Select.
The change is saved and the display shows 0on.
4. Press Down to move to the Open off duration, or Back to cancel and return to the main display.
Open off duration: 120 seconds
After the curtain opens for the ,
it holds its position for the .
Time (seconds)
Temperature
Set point (80°F)
Open on duration: 30 seconds
If the temperature rises above the ,
t
he curtain opens for the .
Close off duration: 150 seconds
After the curtain closes for the , it
holds its position for the .
Close on duration: 60 seconds
If the temperature falls below the ,
t
he curtain closes for the .
Idle band: 4° (+/
–
2°F)
When the temperature is within the ,
t
he curtain remains in its current position.
Time (seconds)