PHCC Pro S3 Series Operator's manual

S5 Series
Dewatering Sump Pumps
5 Year Warranty
PHCC Pro Series
Sump Pumps
Instruction anual
& Safety Warnings
Important Safety Instructions and Warnings
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the PHCC Pro Series pumps. You will need to refer to it
before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
•ALWAYS disconnect the pump from the power source before servicing or making
adjustments.
•NEVER handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
•AKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a
2-prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
•NEVER bypass grounding wires or remove the ground prong from the plug.
•DO NOT use an extension cord. The electrical outlet should be within the length of the
pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
•DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
•AKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power
requirements noted on the nameplate of the pump.
•DO NOT remove the power supply cord and strain relief or connect the pump directly to
the conduit.
•NEVER install the pump in locations classified as hazardous in accordance with the
National Electrical Code, ANSI/NFPA 70.
•ALWAYS install the pump in accordance with the National Electric Code and all
applicable local codes and ordinances. All wiring should be performed by a licensed
electrician.
•DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
•DO NOT expose the control unit to any type of moisture, water, rain or snow.
•DO NOT operate the pump or control unit if it has been damaged in any way.
•DO drill an air bleed hole in the discharge pipe when a check valve is used. Drill
the hole angled toward the bottom of the sump to avoid splashing water outside
the sump pit. If a hole is not drilled above the pump, an air lock may prevent the
pump from operating. The hole must be drilled above the water line but below the
check valve. The optimum size of the hole is different for different pumps. Drill a
1/8” (3.2mm) hole in the discharge pipe for the S3 Series and S5 Series pumps.
•DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
S3 & S5 Series pumps are not designed for this purpose. The S3 and S5 Series sump
pumps are designed for ground water use only.
•DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc.
645 Heathrow Drive, Lincolnshire, IL 60069
• The control unit must receive 115V AC +/- 5% and 60 Hz from the AC outlet. Lower
voltage may cause the power failure alarm to activate.
• These primary pumps will not provide protection during a power outage. With the risk of
property damage from high water levels, the addition of a PHCC Pro Series battery back-
up sump pump system is highly recommended.
• After the initial installation, be sure to check the operation by filling the sump with
water and observing the pump operation through one full cycle.
• For continuous duty operation, the pump must be submerged at least 3/4 of the depth
of the pump at all times.
• In instances where the discharge line is exposed to freezing temperatures, the pipe
must be sloped downward so any remaining water will drain out. Failure to do so will
prevent water from exiting the sump and damage the pump if the line freezes.
Installation Instructions
Prior to Installation
1. Visually inspect your pump. Products may be damaged during shipping. If the product
has been damaged, contact your place of purchase or Glentronics, Inc. before
installation.
2. Thoroughly read the instructions provided to learn specific details regarding installation
and use. This manual should be retained for future reference.
CAUTION
WARNING
NOTICES
S3 Series
Dewatering Sump Pumps
4 Year when purchased and
installed by a contractor,
otherwise 3 year
Risk of electric shock. To reduce this risk, observe the
following precautions.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
1
The
Dual Float Deluxe
Dual Float
Controller
odel Discharge Amps ax Solid ax GP / GPH
No. HP Volts Diameter @ 10’ Handling Head @ 10’
S3033 1
/
3115 11
/
2” 4.0 7
/
8” 30’ 50 3000
S3050 1
/
2115 2” 4.3 7
/
8” 33’ 65 3900
S3100 1 115 2” 11.5 13
/
4” 52’ 92 5520
S5033 1
/
3115 11
/
2” 4.0 11
/
2” 26’ 59 3540
S5050 1
/
2115 2” 6.8 13
/
4” 36’ 83 4980
Specifications

Installing the Pump
1. Use a pit that conforms to all local codes and is large enough to accommodate the pump
and float switch. The minimum requirements for pumps with the double float assembly are
10” in diameter and 14” deep. However, larger sump pits are preferred, since they will
extend the discharge cycle and reduce the number of times the pump turns on.
2. Clean the pit of all debris. The pump’s intake screen must be kept clear.
3. The pump should not be set directly
onto a clay, earthen, or sand base. You
may install bricks or blocks under the
pump to provide a solid base.
4. The pump should be level.
5. Install discharge plumbing according to
local, regional and state codes. Rigid
PVC pipe is recommended.
6. The sizes of the discharge outlets on the
pumps vary from 11⁄2“ to 2“. Try to
match the size of the discharge pipe to
the size of the outlet on the pump to
maintain the optimum pumping
capacity. If you are using a PHCC Pro
Series pump with a 2“ discharge outlet
to replace a pump in a system that has
been plumbed with 11⁄2“ pipe, you may
use the adapter included with the
system to reduce the size of the
discharge outlet to 11⁄2“. However, this
will reduce the capacity of the pump.
7. An in-line check valve is recommended
to prevent back-flow. This check valve
is mandatory when sharing a discharge
line with another pump (i.e. a back-up
pump or a second primary pump). Note:
When using a check valve, an air blee
hole of 1⁄8“(3.2mm) nee s to be rille
in the ischarge pipe. The hole must be rille above the water line but below the check
valve. A small stream of water will escape through this air blee hole when the pump is
running, so the hole shoul be rille on an angle towar the bottom of the sump pit.
8. Install a gate valve or ball valve as required by any codes.
9. Secure the power cord to the discharge pipe with wire ties or clamps to prevent
interference with the float assembly.
10. A pit cover is recommended for all installations as a safety measure, and to prevent
debris from falling into the pit.
11. A cover is required in all sewage pump installations with gas-tight seals to contain gases
and odors. A vent pipe should be added in any sewage installation.
12. In instances where the discharge line is exposed to freezing temperatures, the pipe must
be positioned in a downward slope so any remaining water will drain away. Failure to do
this will prevent water from exiting the pit and damage the pump if the line freezes.
Installing the Double Float
The PHCC Pro Series double float switch is easy to
install by using the enclosed metal hose clamp.
1. Hold the float switch to the discharge pipe so the
cage is below the bracket.
2. Secure the float to the pipe with the enclosed
hose clamp, but do not completely tighten the
clamp at this time.
3. Position the float switch to a level where the
bottom of the float cage is no lower than 3“
above the bottom of the pump and no higher
than 1“ below the top of the pit. To avoid debris
pouring into the float, it should be positioned on
the side of the discharge pipe opposite the drain tile. Note: It is important to mount the
float below the rain tile that empties into the pit. Mounting it above the rain tile woul
allow water to fill the rain tile before the pump is activate to pump out the water.
4. Once the float switch is in the desired position, tighten the clamp.
Installing the Vertical Float
The vertical float switch contains a single large float.
Water will lift the float to the top of the lift rod
which will raise the lift rod and activate the pump.
As the pump evacuates the water from the pit the
float will drop, lowering the lift rod and turning off
the pump.
1. Fully open the metal hose clamp and insert it
through the slots in the mounting bracket of the
float switch.
2. Place the hose clamp over the discharge pipe so
that the gripping tabs are against the pipe and
select the desired activation level of the pump.
3. The pumping range can be adjusted by moving the float stop up or down the lift rod.
4. To avoid debris from pouring onto the float, it should be positioned on the side of the
discharge pipe opposite the drain tile.
5. Once the float switch is in the desired position, securely tighten the hose clamp. Note:
The cable from the switch must remain outside the hose clamp.
Connecting the Pump and Controller
Deluxe Dual Float Controller odel # DFC2
1. Mount the controller to the foundation, drywall
or a stud through the 2 holes on the cabinet
using the proper mounting hardware for the
application. The controller should be mounted
at least 4’ from the floor and within 4’ of the
outlet.
2. Open the plastic door on the top of the unit and
using a small flat head screwdriver adjust the
dial to select the number of seconds that the
pump will run after the bottom float drops. The
timer can be adjusted from 5-45 seconds. The
manufacturer default is about 10 seconds.
Install a 9V battery and replace the door.
3. Plug the control box into a properly grounded,
3-prong receptacle. Then, plug the pump into
the receptacle on the control box. Do not use an extension cord.
4. Make sure the Power Failure Alarm slide switch is in the ON position.
Vertical Float Switch odel # 1020012
1. Plug the vertical float switch cord into a properly grounded 3-prong receptacle. Then, plug
the pump into the receptacle on the float switch cord. Do not use an extension cord.
Connecting to a Security System
The Deluxe Controller (Model DFC2) includes a terminal on the
right side of the control box to connect to a security system
or other alarm devices. There are (3) three positions for wire
connections on this terminal: N.O. – normally open, N.C. –
normally closed, and Common.
1. Check your security system to determine whether an open
(no contact) or closed (making contact) connection is
needed to activate the alarm.
2. The security system will provide (2) two connection terminals to extend wires to the
control terminal. Strip two wires 1/4“ each. Connect either wire to the common
terminal. To secure the wire into the terminal, insert the exposed wire into the hole on
the side of the terminal next to the screw marked common. Turn the screw a few turns to
lock-in the wire.
3. If the security system requires a closing of a contact to activate the alarm, secure the
other wire into the terminal hole labeled N.O. (normally open). If the security system
requires an opening of a contact, secure the wire into the terminal hole labeled N.C.
(normally closed). Note: Only the “AC power out” an ‘Float raise for 10 minutes” alarms
will activate the remote
terminal signal.
Completing the Installation (all models)
1. After the initial installation, be sure to check the pump operation by filling the sump with
water and observing the pump through one full cycle. When using the dual float the pump
should run for 10 seconds after the lower float drops. When using the tethered float the
pump should shut off when the float is tilted down. Note: When the pump activates, it
shoul have a “normal pumping” soun . Any abnormal soun , vibration, or lack of output is
the signal of a problem. Stop the pump an refer to the troubleshooting gui e.
2. Replace the pit cover making sure not to pinch or crimp the pump wire with the cover.
The pit cover either has a ‘hole punch’ that will allow the cord to be passed through or
one can be drilled.
Product Operation
Dual Float Switch
(included with controller models DFC1, DFC1.5 and DFC2)
The dual float switch contains two large floating rings enclosed
within a protective cage. Water will lift the bottom float by a 1⁄4“,
which will activate the pump. If for any reason the lower float does
not activate the pump, the water will rise and activate the second
switch. As the pump evacuates the water from the pit the floats
will drop. The pump will run for an additional 10 seconds to extend
the cycle after the lower float drops. Note: When mounting the
float switch, position the bottom of the cage at the height you want
the pump to activate.
WARNING
WARNING
This installation must be in accordance with the National
Electric Code and all applicable local codes and ordinances.
ake sure the outlet is single phase, 115V and 60HZ for all
the pump installations.
PUMP
WIRE
2

Deluxe Dual Float Controller odel # DFC2
The benefit of this controller is that it will sound an alarm
when problems exist regarding the ability of the sump
pump to keep the basement dry.
The PHCC Pro Series Deluxe Dual Float Controller features a
series of warnings (audible and visual) that pinpoint
potential problems with the pump, switch and power
conditions. The controller will sound an alarm when
power has been interrupted, when the pump has run for
more than 10 minutes continuously, or when the 9V
battery is low. The 9V battery (sold separately) runs the
controller during a power outage, allowing it to sound an
alarm if the circuit breaker trips, the controller is not
plugged in securely, or the homes power is interrupted.
Note: The 9V battery will only power the switch, not the
pump. The Deluxe Controller has a dial (located in the
battery compartment) to adjust the number of seconds
that the pump will run after the float drops. The Deluxe
Controller will also run the pump once a week for approximately four (4) seconds. This test
will exercise the pump and help ensure the pump is working properly.
Operating the Pump in a Continuous Duty Application
The PHCC Pro Series pumps are rated for continuous duty and may be used in applications
requiring continuous pumping including fountains, ponds, etc. For use in any continuous
duty application the pump should be plugged directly into the wall outlet without the use of
a controller. The outlet must be a single phase properly grounded 3-prong receptacle, 115V,
60HZ. For continuous uty operation, the pump must be submerge at least 3/4 of the epth
of the pump at all times.
Understanding the Warnings and Alarms ( odel # DFC2)
AC power is out
There are several causes for power failure.
The most common are a power outage by
the electric company or a tripped circuit
breaker. Although the deluxe controller
can not run the pump, it will sound an
alarm indicating the loss of power. This
will allow the homeowner to address the
problem. If this warning light and alarm
are on, the control box is not receiving
AC power for one of several reasons:
1. The control box is not plugged in.
2. The power to the house is out.
3. The circuit breaker to that outlet has been tripped.
4. The ground fault interrupter has been tripped for that outlet.
5. A power brownout is taking place.
Note: A PHCC Pro Series battery backup sump pump system can protect the basement uring a
power outage. It will automatically activate a separate 12-volt battery powere pump, which
will keep the basement ry until power is restore .
Power Failure Alarm slide switch
When the controller is not receiving AC power, the monitoring features and the audible
alarms are powered by the 9-volt battery. This type of battery will power the controller for
many hours, but not indefinitely. Once the source of the AC power alarm is determined, it is
suggested that the Power Failure Alarm slide switch be turned to the OFF position until the
power is restored. This will preserve the battery and silence the alarm. When AC power is
restored, slide this switch back to the ON position. Note: If the AC power is restore an the
sli e switch is in the OFF position, the alarm an light for the 9-volt battery warning will
activate, even if the battery is goo . This is a remin er to reset the alarm. Sli e the switch
to the ON position. If the battery is goo , the light will go out. If the alarm continues to
soun , replace the battery.
The system is operating
This light should be ON and flashing at all times. It is included to indicate that the system
is monitoring the sump conditions. This light will not illuminate when:
1. The power is out and the Power Failure Alarm slide switch is in the OFF position.
2. The power is out and the 9V battery is discharged.
3. The controller is not functioning. Contact Glentronics service department.
The 9-volt battery is low
1. The 9-volt battery located in the top of the control box is coming to the end of its useful
life. Replace it with a new 9-volt alkaline battery.
2. The Power Failure Alarm switch is in the OFF position. It must be in the ON position at
all times, except when silencing an actual power failure condition.
Pump or float problem
This key feature monitors the time that the float switch is continuously up or in the
activated position. It is unusual for a pump run for 10 or more minutes continuously. This
can occur for many different reasons. Either the float is stuck in the up position, there is a
mechanical problem with the pump, or there is a problem with the plumbing connections.
Please refer to this manual’s Troubleshooting Guide on the following page.
See page 4 for aintenance Check List and Backup Installation
3
DFC2
Limited Warranty
By opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your
product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the
retail store or authorized distributor where you purchased it for a refund.
To the extent permitted by law, this warranty and the remedies set forth are exclusive and in lieu of all other warranties, remedies and conditions, whether oral, written, statutory, express or implied.
GLENTRONICS, INC. disclaims all statutory and implied warranties, including without limitation, warranties of merchantability and fitness for a particular purpose and warranties against hidden or latent defects,
to the extent permitted by law. GLENTRONICS, INC. will not be liable for any incidental, special or consequential damages for breach of any express or implied warranties on this product. In so far as such
warranties cannot be disclaimed, GLENTRONICS, INC. limits the duration and remedies of such warranties to the duration of this express warranty and, AT GLENTRONICS, INC.'s option, the repair or replacement
services described below. Some states (countries and provinces) do not allow limitations on how long an implied warranty (or condition) may last, so the limitation described above may not apply to you.
Any and all causes of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be governed by and construed under the laws of the State of
Illinois. Any cause of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be filed only in the Circuit Court of the 18th udicial District,
Lake County, Waukegan, Illinois, or in the Northern District of Illinois if filed in Federal Court. The maximum liability for any product described in this warranty shall be the cost of product replacement only.
If any term is held to be illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or impaired.
What is Covered by this Warranty?
GLENTRONICS, INC. warrants to the end purchaser that its pumps, switch and control unit products are free from defective materials and workmanship for the periods indicated below:
All parts and labor (excluding installation) for a period of:
• 4 years from the date of installation, when purchased and installed by a contractor and used intermittently as a sump pump (S3 Series), otherwise 3 years
• 5 years form the date of installation when intermittently as a sump pump (S5 Series)
• 1 year from the date of installation when used in continuous duty operations such as fountains or ponds
The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace
the product and return it postage prepaid.
What is NOT Covered by this Warranty?
This warranty does not cover the cost or value of damaged property, including expressly any property that has been affected by water overflow, seepage or flooding. If GLENTRONICS, INC. determines that a
product is deemed defective under this warranty agreement, it will repair or replace the PRODUCT ONLY. GLENTRONICS, INC. will not cover the cost to reinstall the product, nor will GLENTRONICS, INC. pay the
cost of having a plumber or contractor repair or replace the product.
GLENTRONICS, INC. will not repair or replace a product that was installed incorrectly. A product shall be considered “installed incorrectly” when it deviates in any way from the instructions described in this manual.
This warranty does not cover product problems resulting from handling liquids hotter than 104 degrees Fahrenheit, handling inflammable liquids, solvents, strong chemicals or severe abrasive solutions; user
abuse; misuse, neglect, improper maintenance, commercial or industrial use; improper connection or installation, damages caused by lightning strikes; excessive surges in AC line voltage; water damage to the
controller; other acts of nature, or failure to operate in accordance with the enclosed written instructions.
How to Obtain Warranty Service
Within thirty (30) days of the product’s defective performance, the unit must be shipped, freight prepaid, or delivered to GLENTRONICS, INC. to provide the services described hereunder in either its original
carton and inserts, or a similar package affording an equal degree of protection. Products not received by GLENTRONICS, INC. at the address indicated below within thirty (30) days of the product’s defective
performance will not be considered for warranty service. Products received after eighteen the above timeframe, fall outside of the timeframe for warranty service and will not be eligible for warranty service. The
product must be returned to GLENTRONICS, INC. for inspection in order to be considered for warranty service. If the product is not returned to GLENTRONICS, INC. or the product is inspected by any person,
plumber, contractor or business other than GLENTRONICS, INC., this warranty shall no longer be valid. Prior to defective operation, the unit must not have been previously altered, repaired or serviced by anyone
other than GLENTRONICS, INC., or its agent; the serial number on the unit must not have been altered or removed; the unit must not have been subject to accident, misuse, abuse or operated contrary to the
instructions contained in the accompanying manual. The dealer's dated bill of sale, or installer’s invoice must be retained as evidence of the date of purchase and to establish warranty eligibility.
Where are Products Sent for Warranty Service? Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
How Can I Obtain ore Information? By calling 800-991-0466

© Glentronics, Inc. 06/15
1806066 4
Visit our website www.stopflooding.com for more information about the PHCC
Pro Series AC pumps and battery backup sump pump products.
aintenance Check List
Maintenance should be performed 1-2 times per year.
1. Remove all debris from the the pump strainer and bottom of
the pit.
2. Remove all debris floating in the water.
3. Remove all debris from the float switch cage.
4. Fill the pit with water. Make sure pump turns on at the
intended level.
5. While the pump is running, make sure pump is evacuating water
at a good pace.
6. While the pump is running, make sure a stream of water is
escaping from the air bleed hole. If not, clear the hole of any
deposits or debris.
7. Unplug the control box from the wall. Make sure the “AC power
is out” light and alarm sound (DFC2).
Backup Installation
When the power goes out, the PHCC Pro
Series AC sump pumps will not operate.
For protection during a power outage, a
PHCC Pro Series battery backup system
can be installed. There are three systems
with matching batteries that will provide
protection. The illustration at right is an
example of a typical battery backup
installation.