※Addin a node ID allocated by Z-Wave Controller means inclusion. Removin a node
ID allocated by Z-Wave Controller means exclusion.
※Failed or success in includin /excludin the node ID can be viewed from the Z-Wave
Controller.
LE Indication
To distin uish what mode the switch is in, view from the LED for identification.
State Type LE Indication
Normal Whenever we press button to PAC01, the LED will on; Otherwise the
LED is off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals.
Learnin When PAC01 is in learnin mode, LED flashes on and off alternately
and repeatedly at 2 second intervals.
Programming
1. Basic Command Class / Thermostat Setbac Command Class
PAC01 will respond to BASIC and THERMOSTAT_SETBACK commands that are
part of the Z-Wave system. If PAC01 is included as a secured node, it will only re-
sponse to the security encapsulation command of BASIC and THERMOSTAT_SET-
BACK.
1-1 BASIC_GET / THERMOSTAT_SETBACK_GET
Upon receipt of the followin commands from a Z-Wave Controller, the Adapter will
report its state to the node inquired.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report Ener y Savin Mode: [Command Class Basic, Basic Report, Value = 0]
Report Comfort Mode:[Command Class Basic, Basic Report, Value = 0xFF]
Thermostat Setback Get Command:[Command Class Thermostat Setback, Ther-
mostat Setback Get]
Thermostat Setback Report Command:
Report Ener y Savin Mode:[Command Class Thermostat Setback, Thermostat
Setback Report, Setback Type=0,2, Value=0x7A]
Report Comfort Mode:[Command Class Thermostat Setback, Thermostat Set-
back Report, Setback Type= 0,2,Value =0x00~0xFF]
1-2 BASIC_SET / THERMOSTAT_SETBACK_SET
Upon receipt of the followin commands from a Z-Wave Controller
[Command Class Basic, Basic Set, Value = 0] : Set Ener y Savin Mode
[Command Class Basic, Basic Set, Value = 0xFF] : Set Comfort Mode.
[Command Class Thermostat Setback, Thermostat Setback Set, Setback
Type=0,2 setbackState = 0x7A] : Ener y Savin Mode
[Command Class Thermostat Setback, Thermostat Setback Set, Setback Type
=0,2, setbackState = 0x00~0xFF] : Comfort Mode.
1. Z-Wave’s Groups
The Adapter can be set to send reports to associated Z-Wave devices. It supports
one association roup with one nodes support for roupin 1. For roup 1, the
Adapter will report THERMOSTAT_SETBACK_REPORT and DEVICE_RESET_LO-
CALLY_NOTIFICATION.
2-1 Groupin 1 Lifeline(Maximum 1 nodes)