HD7833/50 /51
3-8
Note:
Please note after replacing the boiler the appliance has to
be restored to factory default. The lling procedure (cold
ush), known from the predecessor Senseo’s is no longer
available after the ush before rst use has been executed.
When the “restore to factory default” procedure is not
carried out, a new and empty boiler can be switched on,
without having the protection of the initial ush procedure,
causing the thermal fuses in the heating element to fail.
After a boiler replacement or drained system, carry
out the “Restore boiler_empty_ag to factory
default” procedure! Then the initial ush procedure
can be carried out.
Descaling
Descaling is an important element in Senseo maintenance.
It should be done at least once every months, up to
times a Year! This will prolong the life of your appliance
and will guarantee optimal brewing results for a long time.
Use the correct descaling agent. Only citric acidbased
descalers are suitable for descaling the SENSEO® machine.
This type of descaler descales the appliance without
damaging it. For the correct amount, see under ‘Descaling
procedure’ below.
Each descaling mixture can be used only once. After use,
the descaling mixture is no longer active. We advise you to
use the special SENSEO® Descaler (HD).
Read the instructions on the package of the descaling
agent. Never use a descaling agent based on mineral acids
such as sulphuric acid, hydrochloric acid, sulphamic acid
and acetic acid (e.g. vinegar). These descaling agents may
damage your SENSEO® coee machine.
Follow the steps in the section headed “Descale the
appliance” see DFU (Direction for Use manual).
!
Volume adjustment
The PCB circuit board makes it possible to adjust the
volume output by means of pushing the onecup and
twocup user controls.
How to adjust the volume output:
. Make sure the boiler is lled properly, otherwise
perform ll procedure see DFU for instructions.
. Switch appliance on and wait until the unit is ready to
brew.
. Make sure a pod holder is placed, but without a
Coee POD. (Only adjusting with plain water)
. Place a cup on the drip tray cover and push the one
cup button.
. When the appliance has nished it is stabilized to
perform the volume adjustment.
. Empty the cup, podholder and push again for one cup
setting, measure the volume output with a graduated
beaker. In the table you can nd the requirements for
the minimum / maximum volume output cc/mL values
depending from the country version:
Onecup setting, Including Pod holder, water spec.
(Without Coee pod)
Min. water cc/mL Max. water cc/mL
Small cup ( ml)
Normal cup ( ml)
. Unplug the appliance from the mains.
. Press the and cup button simultaneously and
plug the mains on.
. When above step succeeded the LED will turn on
continuously.
. Depending if the volume has to de or increase you
have to push the one or two cup button.
Every time you push the or cup button the LED
will turn o for . second (feedback to user) and the
pump time will be shortened or lengthened for .
seconds depending which button was pushed.
Pushing 1 cup button pump, time will be shorten with
. sec is approximately - 3.5 cc/mL (less coee)
Pushing 2 cup button pump, time will be lengthen
with . sec is approximately . cc/mL more
coee)
When the volume has to increase with cc for
example, push the 2 cup button times. The new
value will be stored when you switch the appliance o
by pushing the main switch. (LED will turn o).
. Turn appliance on again and brew one cup, measure
the volume. In case the volume is not within
specication repeat steps .
. End.
Repair instruction