manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Philips
  6. •
  7. Light Fixture
  8. •
  9. Philips Lightolier E3 Series User manual

Philips Lightolier E3 Series User manual

This manual suits for next models

2

Other Philips Light Fixture manuals

Philips Arcitone 336053196 User manual

Philips

Philips Arcitone 336053196 User manual

Philips CTS3-13 User manual

Philips

Philips CTS3-13 User manual

Philips CoralCare User manual

Philips

Philips CoralCare User manual

Philips Brisa FP21U User manual

Philips

Philips Brisa FP21U User manual

Philips Specplus SPS2GFSVA332 User manual

Philips

Philips Specplus SPS2GFSVA332 User manual

Philips 33218-31-16 User manual

Philips

Philips 33218-31-16 User manual

Philips Alter Concept SR T5 User manual

Philips

Philips Alter Concept SR T5 User manual

Philips Selecon PLPROFILE1 MKI Instruction Manual

Philips

Philips Selecon PLPROFILE1 MKI Instruction Manual

Philips 6912528PH Manual

Philips

Philips 6912528PH Manual

Philips ProSpec 37106 User manual

Philips

Philips ProSpec 37106 User manual

Philips Lytespan 22MW4 User manual

Philips

Philips Lytespan 22MW4 User manual

Philips Lytespan 83B70E User manual

Philips

Philips Lytespan 83B70E User manual

Philips 6910153PH Manual

Philips

Philips 6910153PH Manual

Philips Lightoiler Alter Concept SR T5 User manual

Philips

Philips Lightoiler Alter Concept SR T5 User manual

Philips C4T4W User manual

Philips

Philips C4T4W User manual

Philips Lytecaster 1004ICV User manual

Philips

Philips Lytecaster 1004ICV User manual

Philips FS01 User manual

Philips

Philips FS01 User manual

Philips Lirio 57981/**/16 User manual

Philips

Philips Lirio 57981/**/16 User manual

Philips 69112-31-PH User manual

Philips

Philips 69112-31-PH User manual

Philips Paraplus II PPH2G8FW217 User manual

Philips

Philips Paraplus II PPH2G8FW217 User manual

Philips Lytespan 8112 User manual

Philips

Philips Lytespan 8112 User manual

Philips 40747-48-16 User manual

Philips

Philips 40747-48-16 User manual

Philips 1001HCB User manual

Philips

Philips 1001HCB User manual

Philips Calculite IS-PA User manual

Philips

Philips Calculite IS-PA User manual

Popular Light Fixture manuals by other brands

Veko Magnus manual

Veko

Veko Magnus manual

Cooper Lighting Halo L10538 specification

Cooper Lighting

Cooper Lighting Halo L10538 specification

Emos CLASSIC ZY1431T manual

Emos

Emos CLASSIC ZY1431T manual

Westinghouse Outdoor Lighting Fixture owner's manual

Westinghouse

Westinghouse Outdoor Lighting Fixture owner's manual

Hedler C 12 silent Operation manual

Hedler

Hedler C 12 silent Operation manual

Blizzard Lighting Puck: CSI manual 

Blizzard Lighting

Blizzard Lighting Puck: CSI manual 

Energetic Lighting ELYSL-5004 Series installation instructions

Energetic Lighting

Energetic Lighting ELYSL-5004 Series installation instructions

Lightmaxx Shaft 5R user manual

Lightmaxx

Lightmaxx Shaft 5R user manual

Triarch 31083 Assembly instructions

Triarch

Triarch 31083 Assembly instructions

IKEA TIVED Assembly instructions

IKEA

IKEA TIVED Assembly instructions

Lightolier LP200 specification

Lightolier

Lightolier LP200 specification

Chauvet Professional ROGUE R1 BEAM WASH user manual

Chauvet Professional

Chauvet Professional ROGUE R1 BEAM WASH user manual

Martin MAC 250 Krypton user manual

Martin

Martin MAC 250 Krypton user manual

Cooper Lighting Halo L3232E Specification sheet

Cooper Lighting

Cooper Lighting Halo L3232E Specification sheet

Stageline ODW-2410RGBW instruction manual

Stageline

Stageline ODW-2410RGBW instruction manual

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier

Lightolier Paralyte 2424 PLA2G9LS26U specification

Lightolier Lytespan 83ED17S specification

Lightolier

Lightolier Lytespan 83ED17S specification

ArtFox Beam 15R extreme manual

ArtFox

ArtFox Beam 15R extreme manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

E3 Series
GENERAL DUTY THERMOPLASTIC EMERGENCY LIGHTING
Page 1 of 2
Job Information Type:
Job Name:
Cat. No.:
Notes:
Features
Illumination: Illumination
is accomplished with up to
three lamp heads mounted
on the top of the unit. Most
often specified is Lightolier’s
“S” series rectangular lamp
heads. The “S” series lamp
heads incorporate a high
performance parabolic
reflector with a wedge base
tungsten lamp allowing
maximum spacing between
units along a path of egress.
A complete offering of Par 36
sealed beam tungsten, halogen
or MR16 LED lamp heads are
also available.
Housing: Constructed of
impact-resistant, UL 94 V-0,
5 VA thermoplastic. Mounting
is accomplished by means of
the universal j-box mounting
pattern or the keyhole
knockouts provided on the
rear of the housing. The cover
assembly closes and remains
secure via a snap-fit design
and offers tool-free access to
the housing interior. White or
black housing and lamp head
colors are available.
Operating Temperature
Range: Standard Location:
65°F (19°C) to 85°F (30°C)
Damp Location: 32°F (0°C) to
104°F (40°C)
Non-Diagnostic
Electronics: Standard
electronics systems include
a 120/277 VAC dual tap
input transformer. Standard
electronic performance
features include AC line latch,
brownout detection, and
low-voltage battery disconnect
circuitry to maximize battery
service life.
Self-Diagnostics
Electronics: Charging system
is microprocessor driven with
software embedded diagnostic
routine and temperature
compensation. 120/277 VAC
input, surge protection,
brownout, AC lockout, and
low voltage disconnect features
are standard.
Self-Testing Diagnostics
(optional): The diagnostic/
charging platform with self-
testing mode automatically
runs a one-minute self-test
every 30 days and a 30-minute
test on the sixth and twelfth
month. A one-minute or
90-minute test may be initiated
via the push to test switch on
the unit or by activating the
appropriate test command on
the optional IR test device.
Code Compliance
UL 924 listed. NFPA 101,
NEC, BOCA, OSHA and
IBC illumination standards.
Optional UL damp location
listing available (SD2 models
only) 0°C to 40°C.
Warranty
Three year full electronics
warranty. One year full plus
four year prorated lead calcium
battery warranty. Five year full
plus five year prorated nickel
cadmium battery warranty.
E3112WS92SD2
6.84"
(17.37 cm)
13.01"
(33.05 cm)
11.87"
(30.15 cm)
14.53"
(36.91 cm)
5.0"
(12.7 cm)
E3112WPT86W2
E3 Series
GENERAL DUTY THERMOPLASTIC EMERGENCY LIGHTING
Page 2 of 2
Philips Lightolier
e: [email protected]
t: (508) 679-8131
w: www.lightolier.com
E3 Series August 9, 2012
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2012.All rights reserved.
Job Information Type:
Ordering Information
Series
6 V Lead Calcium
E3112 = 12 W2
E3125 = 25 W
E3136 = 36 W1
E3150 = 50 W
6 V Nickel Calcium
E31N25 = 25 W
E31N50 = 50 W
1= One Lamp
Head
2= Two Lamp
Heads
3= Three Lamp
Heads
# of Heads
6 V Tungsten
S6 = 5.4 W
S7 = 7.2 W
S9 = 9 W
12 V Tungsten
S9 = 9 W
S12 = 12.5 W
S18 = 18 W
MR16 LED Lamp Heads*
12 V LED
M7F** = 7 Watt, 35°
Lamp Heads
W= White
B= Black
Housing Color
A= Ammeter3
BD = Battery Disconnect Switch3
DL = Damp Location Listed3
EX = Special Input Transformer (specify voltage &
frequency)4
F1 = 120 VAC Input Fuse3
F2 = 277 VAC Input Fuse3
P1 = 120 VAC Power Switch3
P2 = 277 VAC Power Switch3
T= Self-Testing Diagnostics3
TA = Audible Self-Testing Diagnostics3
TD = Time Delay, 15 Minutes3
V= Voltmeter3
Factory Installed Options3
Accessories (order as a separate item)
SDREMOTE = Infrared Remote Test Device
PCS1 = Polycarbonate Vandal Shield
WG5 = Wire Guard
Note 1) Not available with DL option. 2) Only available with non-diagnostic models. 3) Only available with diagnostic electronic models. 4) Some option combinations
may impact UL listing, consult factory for specifics.
12 V Lead Calcium
E3225 = 25 W
E3236 = 36 W2
E3250 = 50 W
12 V Nickel Calcium
E32N25 = 25 W
E32N50 = 50 W
Optics Wall mounted 7.5' AFF, ‘S9’ 6 V 9 W Tungsten Lamps Represented
7.5 ft.
25 ft.
6 ft.
Average initial footcandles at floor = 1.08
Maximum initial footcandles at floor = 3.0
Minimum initial footcandles at floor = 0.3
Maximum to minimum ratio = 10.00
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/50/20. Lightolier is not responsible for site specific conditions that
may alter the results.
0.3
0.3
0.2
1.2
1.1
0.4
2.4
2.3
0.7
2.3
1.8
0.6
1.6
1.0
0.4
0.9
0.6
0.4
0.7
0.6
0.5
0.9
0.6
0.4
1.4
0.8
0.4
2.3
1.5
0.5
2.6
2.4
0.8
1.6
1.7
0.9
.5
0.5
0.3
0.7
0.7
0.4
2.0
1.9
0.6
2.6
2.2
0.7
2.0
1.3
0.4
1.2
0.7
0.4
0.8
0.6
0.4
0.7
0.6
0.4
1.1
0.6
0.4
1.8
1.1
0.4
2.5
2.0
0.6
2.2
2.2
0.7
0.8
0.9
0.4
0.2
0.3
0.2
Blank = Standard,
Non-Diagnostic Unit
SD2 = Diagnostic
Electronics
Model Designator
Electrical Specifications
Non-Diagnostic Models (60 Hz)
6 V Lead Calcium: 0.115 A (120 VAC), 0.050 A (277 VAC)
6 V NiCad: 0.160 A (120 VAC), 0.071 A (277 VAC)
12 V Lead Calcium: 0.126 A (120 VAC), 0.055 A (277 VAC)
12 V NiCad: 0.116 A (120 VAC), 0.051 A (277 VAC)
1 FC Average
Self-Diagnostics Models (60 Hz)
6 V Lead Calcium: 0.113 A (120 VAC), 0.055 A (277 VAC)
6 V NiCad: 0.157 A (120 VAC), 0.065 A (277 VAC)
12 V Lead Calcium: 0.331 A (120 VAC), 0.146 A (277 VAC)
12 V NiCad: 0.200 A (120 VAC), 0.094 A (277 VAC)
Blank = No
Lamp Heads
* Lamp included per UL acceptance. ** UL testing restricts using any substitutes for this lamp option.