Philips ReCare 7.0 T User manual

Please read this entire manual carefully
before operating your new treadmill
and save it for future use.
User manual
Register your product and get support at
www.philips.com/welcome
PTE7000MT
ReCare
Treadmill
7.0 T
Register your product and get support at
www.philips.com/welcome
PTE7000MT

Thank you for your recent purchase of the Philips physical
rehabilitation treadmill, 7.0 T. Philips physical therapy and exercise
solutions provide simple, reliable products that oer the most
relevant feedback to caregivers and users to achieve best-in-class
outcomes and empower individuals to build condence in rebuilding
and maintaining healthy lifestyles and keep in touch with their
communities.
Your new product has been manufactured by one of the world’s
leading medical product manufactures. It is backed by one of the
most comprehensive warranties in the industry. Through our dealers,
distributors and manufacturer’s representatives, we will do all we can
to provide many years of successful and prosperous ownership. Your
warranty and service needs will be addressed either through your
regional sales representative or our highly trained service technicians.
It is their responsibility to provide you with both the technical
knowledge and access to service personnel to make your ownership
experience more informed, and resolve any issues quickly.
Product registration
Register your product and get support at :
www.philips.com/welcome .
This will ensure we have all your details quickly at hand in dealing with
any after sales support. For fastest support visit us online for chat and
self service solution at :
www.philips.com/support .
Philips therapy solutions
Delivering better outcomes

Contents
Important safety instructions 5
Important electrical information
Important operation instructions 10
Application specication 11
Operating principle 13
Signicant physical characteristics 13
8
Signicant performance characteristic
14
Intended user prole 15

44
48
59
67
Features 18
Operation of your new treadmill 21
Data transfer software instructions 36
Using a heart rate transmitter 40
Assembly instructions for 7.0 T
Important assembly instructions
Maintenance
71
Specications
Description of packaging symbols
Operating the 7.0 T 16

5
Attention
Read all instructions in this manual before using this device.
Danger
To reduce the risk of electric shock disconnect your treadmill from the
electrical outlet prior to cleaning and/or service work.
Warning
• Do not modify this equipment without authorization of the
manufacturer.
• To reduce the risk of burns, re, electric shock, or injury to persons,
install the treadmill on a at level surface with access to a 115-volt
AC, 60 Hz, 20-amp grounded outlet. Do not use an extension cord
unless it is 12awg or larger, with only one outlet on the end. The
treadmill should be the only appliance in the electrical circuit. Do not
attempt to disable the grounded plug by using improper adapters, or
in any way modify the cord set; a serious shock or re hazard may
result along with computer malfunctions.
• To avoid risk of electric shock, this equipment must only be con-
nected to a supply main with protective earth.
• Use this device only for it’s intended use as described in this
manual.
• Keep children away from the treadmill. There are moving parts,
obvious pinch points and other caution areas that can cause harm.
Important
safety
instructions

6
• Except as instructed for use of the device, keep hands away from all
moving parts.
• Keep the electrical cord away from heated surfaces and out of all
travel lanes and do not operate the treadmill if the cord or plug is
damaged.
• Never drop or insert any object into any openings.
• Do not use outdoors.
• To disconnect, turn all controls to the o position then remove the
plug from the outlet.
• This device is designed for commercial use and will meet the
demands of orthopedic, sports wellness and general conditioning
programs.
• Do not attempt to use your treadmill for any purpose other than for
the purpose it is intended.
•The pulse sensors are not medical devices. Various factors, including
the user’s movement, may aect the accuracy of heart rate readings.
The pulse sensors are intended only as exercise aids in determining
heart rate trends in general.
• Heart rate monitoring system may be inaccurate. Over exercise may
result in injury or death. If you feel faint stop exercising immediately.
• Ensure there is a minimum space on the sides of the treadmill of
two feet for proper operation, easy access and to prevent possible
injuries to others standing or walking nearby. There should be a
minimum of at least one foot of free space at the front and three
and a half feet at the rear.
• Do not use any after market parts on this device, other than those
recommended by Philips.

7
• Do not attempt any servicing or adjustments other than those
described in this manual. All else must be left to trained service
personnel familiar with electro-mechanical equipment and
authorized under the laws of the country in question to carry out
maintenance and repair work.
• Installation and assembly of this product should be performed by
trained personnel only.
• Hold the handlebar for support when getting on or o the treadmill.
• To avoid injury please observe all minimum and maximum
adjustment settings.
• Wear proper shoes. High heels, dress shoes, sandals or bare feet are
not suitable for use on the treadmill. Quality athletic shoes are
recommended to avoid leg fatigue.
• A safety tether cord is provided with this unit. It is a simple magnetic
design that should be used at all times. It is for your safety should
you fall or move too far back on the tread-belt. Pulling this safety
tether cord will stop tread-belt movement.

8
Warning
• Never remove any cover without rst disconnecting AC power. If
voltage varies by 10% or more, the performance of your treadmill
may be aected. Such conditions are not covered under your
warranty. If you suspect the voltage is low, contact your local power
company or a licensed electrician for proper testing.
• Never expose this product to rain or moisture. This product is not
designed for use outdoors, near a pool or spa, or in any other high
humidity environment.
• The treadmill is not protected against the ingress of water or partic-
ulate matter.
• The treadmill is not suitable for use in an oxygen rich environment.
• If not stated otherwise Philips devices are designed for operation in
normal climatic surroundings (IEC 60601-1):
- Temperature: + 10° ... + 36° C
- Relative humidity: 30 ... 90 % (non condensing)
- Air pressure: 700 ... 1060 mbar
- Maximum operating altitude: approx. 10,000 feet (3000m), with
out pressurization
- Transport and store the devices at a temperature of – 20° ...
+ 50° C.
Important
electrical
information

9
Grounding instructions
This product must be grounded. In the unlikely event that the
treadmill’s electrical system should malfunction or breakdown
grounding provides a path of least resistance for electric current,
reducing the risk of electric shock. This product is equipped with a
cord having an equipment-grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Danger
Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualied electrician or
serviceman if you are in doubt as to whether the product is properly
grounded. Do not modify the plug provided with the product if it will
not t the outlet; have a proper outlet installed by a qualied
electrician.

10
• Never use the treadmill during an electrical storm. Surges may occur
in your facility power supply that could damage the treadmill’s
components.
• All users should have medical clearance before starting any rigorous
exercise program.
• Start the user at a safe exercise level. Do not allow the user to be
over exerted. Symptoms to watch for, but not limited to, are:
Shortness of breath or diculty in breathing, pain or discomfort,
feeling faint.
• Make sure the user warms up and cools down properly to avoid over
taxing the cardio vascular system. Allow three to ve minutes of
warm up and cool down during each exercise session.
Important
operation
instructions

Attention
Read all instructions in this manual before using this device.
Danger
To reduce the risk of electric shock disconnect your treadmill from the
electrical outlet prior to cleaning and/or service work.
Warning
• Do not modify this equipment without authorization of the
manufacturer.
• To reduce the risk of burns, re, electric shock, or injury to persons,
install the treadmill on a at level surface with access to a 115-volt
AC, 60 Hz, 20-amp grounded outlet. Do not use an extension cord
unless it is 12awg or larger, with only one outlet on the end. The
treadmill should be the only appliance in the electrical circuit. Do not
attempt to disable the grounded plug by using improper adapters, or
in any way modify the cord set; a serious shock or re hazard may
result along with computer malfunctions.
• To avoid risk of electric shock, this equipment must only be con-
nected to a supply main with protective earth.
• Use this device only for it’s intended use as described in this
manual.
• Keep children away from the treadmill. There are moving parts,
obvious pinch points and other caution areas that can cause harm.
11
Medical purpose
• Patient warm up before physical therapy session.
• Have the patient walk to improve ambulation and range of motion
after knee/hip/ankle surgery or neurological conditions.
• Allow patients to perform cardiovascular exercise.
Intended patient population
• There is no particular restriction on age, gender, height and nationality.
• Maximal patient’s weight is 200kg.
• Patient must be ambulatory.
• Patient should have medical clearance before starting any rigorous
exercise program. This is especially important for person with a history
of heart disease or other high risk factors.
Intended part of the body or type of tissue applied to or
interacted with:
• Contact site: hands and feet
• Condition: should not have any trauma
Application
specication

12
Intended conditions of use
• Environment including hygienic requirements
- General: intended for indoors use. This product is not designed
for use outdoors, near a pool or spa, or in any other high humidity
environment.
- Conditions of visibility:
Ambient luminance: standard ambient room lighting is
sucient.
Viewing distance: 1 m
Viewing angle: 120°
- Physical
Temperature range: 10°C ~ 36°C
Relative humidity range: 30% R.H. ~ 90% R.H., non condensing
- Hygienic requirements: there is no particular restriction on
hygienic requirements.
• Frequency of use
- Dependent on therapist’s plan.
• Location
- Intended for hospital use, clinic use, home use and research in
academic institutions.
• Mobility
- The product is intended to be xed.
1
1
2
2
3

13
The operator will start the device and use the speed and incline keys
to control motors. When the speed key is pressed a signal is sent to
the AC motor inverter to request a change. The inverter will then send
the appropriate amount of power the AC drive motor to reach the
requested speed. The motor drives the front roller (which in turn
moves the walking belt) through pulleys and fan belt. The incline
motor is operated when the operator presses the incline keys. A
command is generated that is transmitted to the incline control board
where a relay is energized sending AC power to the motor until it
reaches the desired position.
Operating
principle
Please refer to Features of 7.0 T manual.
Signicant
physical
characteristics

14
Please refer to “Unique uses for the 7.0 T” in operating the 7.0 T.
Signicant
performance
characteristic

15
Intended operator
• There is no particular restriction on age, gender, height, weight,
ability and culture.
• Education: University or above
• Knowledge: The operator should read the user’s manual before use.
• Discipline: The operator should receive training from the
manufacturer before use.
• Experience: The operator must have experience in physical therapy.
• Background: The operator must be a major in physical therapy.•
Professional competence: The operator should have the physical
therapist license.
Intended Installer
• There is no particular restriction on age, gender, height, weight,
ability and culture.
• Education: High School or above
• Knowledge: The installer shall be able to manipulate this product
properly.
• Discipline: The installer shall be given a specic training by
manufacturer.
• Experience: The installer must have experience in product assembly
and disassembly.
• Background: The installer must be electro-mechanically trained.
• Professional competence: Normal vision ability required.
Intended
user
prole

16
The treadmill is intended to be used in aiding in the physical
rehabilitation process for patients with orthopedic and neurological
problems. Also used in sports medicine, wellness and general
conditioning programs.
Typical applications for this type of product are
• Patient warm up before physical therapy session.
• Have the patient walk to improve ambulation and range of motion
after knee/hip/ankle surgery or neurological conditions.
• Allow patients to perform cardiovascular exercise
Unique uses for the 7.0 T :
• The walking belt allows for both forward and reverse walking.
• The front and rear incline allows for uphill and downhill walking.
• Symmetry program measures distance between left and right step
lengths. Graphical bio-feedback display motivates patients to
maintain even step symmetry between left and right legs.
Operating
the 7.0 T

17
Other features of the 7.0 T
• Belt speed settings start at 0.1 km/hr.
• The parallel handrails are adjustable to accommodate for pediatric to
large adult sizes.
• Heart rate monitoring using the optional heart rate chest-strap.
Heart rate measurements are not for medical use
The heart rate function on this product is not a medical device and
should not be relied on when accurate readings are necessary. Some
people, including those in a cardiac rehab program, may benet from
using an alternate heart rate monitoring system like a chest or wrist
strap. Various factors, including movement of the user, may aect the
accuracy of your heart rate reading. The heart rate reading is intended
only as an exercise aid for measuring heart rate trends in general.

18
7.0 T – Treadmill
Parts and adjustments
1. Hand grips
2. Electronic console
3. Safety lanyard
4. Adjustable hand rails
5. Handrail horizontal adjustment
6. Handrail vertical adjustment
7. Handrail lift bar
8. Rear step
9. Rear incline
10. Front incline
Features
10
2
3
4
5
6
7
89
1

19
The 7.0 T is an easy product to set up and use, from the adjustments to
the intuitive interface. This section explains how to set up, adjust and
operate your 7.0 T.
Leveling the 7.0 T
Once the 7.0 T is assembled, and placed on a at level oor, it may be
necessary to adjust the four leveling glides on the bottom of the rear
incline unit to ensure proper stability of the 7.0 T. Use a 1/2” wrench
to loosen the top nut of the leveler. Adjust the levelers by hand as
necessary to remove any wobble in the unit. Then tighten the top nut
against the bottom of the stabilizer tube. Make sure the bottom nut
remains cinched against the leveling foot.
Connecting to A.C. power
The 7.0 T A.C. mains input connector is located in the front of the unit.
The input module has an input connector for the line cord, a power
switch and a 20 amp circuit breaker. Turn the power switch to o
when the 7.0 T is not in use.
Lift bar
Vertical adjustment Horizontal adjustment

20
Adjusting the hand rail vertical position
• To lift: Turn both the left and right vertical adjustment knobs
counterclockwise one or two rotations. Then just grab the lift bar
and pull up. The locking pins in the knobs will automatically ratchet
into the indexing holes in the tubes. Tighten the knobs when
desired position is set. There is a numbered scale on the tubes for
repeatable settings.
• To lower: Loosen the two knobs and then pull them out and rotate
slightly until the knob remains out on its own. The pin should now
be disengaged from the tube and you can use the lift bar to lower
the rails. Lower the rail past the position you desire and rotate the
knob again so the pin can engage the holes in the tube. Now lift the
rails to the desired position and lock the knob.
Adjusting the hand rail horizontal position
Turn both the left and right levers counterclockwise one rotation.
Move the rails to the desired position and re-lock the levers. There
are numbered scales on the tubes for repeatable settings. The levers
may be blocked by the rotating tube when position is changed. The
levers can be repositioned by pulling out and rotating them to a new
position, allowing tightening.
Lift bar
The lift bar will make raising and lowering the hand rails easier. You
can remove the lift bars for better patient access by loosening the
locking knobs. Hold the bar with one hand and loosen the knobs with
the other so the lift bar does not suddenly fall to the oor.
Rear step
Additional step lowers the step-up height to 4 inches. To install or
remove the step easily there are two removable pins located under
the rear of the treadmill. Be sure these two pins are in place before
using.
This manual suits for next models