FC7070/01 /11 /61 /81
4-9
To exchange the PCBA in the Lower Stick assy, open the PCB
Box and undo connectors J3 (Main PCBA), J4 (Clean Water
sensor) and J5 (DWT Hall sensor).
J3
J4
J5
To exchange the Motor assy undo the fastons on the two
black wires coming from the Motor assy going to the 4P male
connector to the Upper Stick assy. Unscrew screw Jholding
the DWT Hall sensor in place, and unscrew the two screws I
Holding the Motor assy in place. You are now able to carefully
remove the Motor assy from the Lower Stick assy.
With the Motor assy removed you can also easily access the
hinge construction holding the locking of the DWT handle in
place. Both left and right hinge needs to be installed on the
link before the hinge unit can be reinstalled in the appliance.
Nozzle
To be able to open the nozzle, rst open the hood, take out
the brush cover and remove the brushes. Clean the inside of
the brush compartment if necessary.
Then carefully remove the side panels left and right from the
nozzle, starting from the rear of the nozzle, along the top
and bottom side of the nozzle, working to the front of the
nozzle, ending at the hinge of the hood. Most connections
are snaps, only the mating surface with the hood is a snap
over construction, there the side panel needs to be lifter
upwards a little bit to become undone. Only use a athead
screwdriver when absolutely necessary, because the plastic is
easily damaged.
!
1
2
3
Carefully unsnap the collar from the nozzle. Next remove 11
screws L(2 are underneath the collar) to be able to remove
the upper housing from the nozzle.
L
L
L
L
L
L
L
L
L
L
L
You can now easily access all components like the Nozzle
PCBA, pump, suction tube, drive train etc.
When reassembling please take care that the different seals
are placed back properly, keep in mind that especially the
nozzle is a wet environment, and that all electronic leads are
double isolated.
DISASSEMBLY- AND RE-ASSEMBLY ADVISE