manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Phytec
  6. •
  7. Gateway
  8. •
  9. Phytec phyGATE Tauri-S L-1012e.A3 User manual

Phytec phyGATE Tauri-S L-1012e.A3 User manual

Other Phytec Gateway manuals

Phytec phyGATE Tauri-L User manual

Phytec

Phytec phyGATE Tauri-L User manual

Phytec phyGATE-Tauri-L L-1028e.A3 User manual

Phytec

Phytec phyGATE-Tauri-L L-1028e.A3 User manual

Phytec phyGATE Tauri-L User manual

Phytec

Phytec phyGATE Tauri-L User manual

Phytec phyGATE-Tauri-L i.MX 8M Mini User manual

Phytec

Phytec phyGATE-Tauri-L i.MX 8M Mini User manual

Popular Gateway manuals by other brands

Telecom FM onestream gfx Programming guide

Telecom FM

Telecom FM onestream gfx Programming guide

UfiSpace LoRa GPE810U Quick setup guide

UfiSpace

UfiSpace LoRa GPE810U Quick setup guide

Merak MMk-736F Quick setup guide

Merak

Merak MMk-736F Quick setup guide

Robustel R3010 user guide

Robustel

Robustel R3010 user guide

turck BL20-PG-EN-V3 user manual

turck

turck BL20-PG-EN-V3 user manual

IBM Security Web Gateway Appliance quick start guide

IBM

IBM Security Web Gateway Appliance quick start guide

SSS Siedle Smart Gateway Commissioning instructions

SSS Siedle

SSS Siedle Smart Gateway Commissioning instructions

ADTRAN 424RG Installation

ADTRAN

ADTRAN 424RG Installation

Chorus Hyperfibre XGS-250WX-A user guide

Chorus

Chorus Hyperfibre XGS-250WX-A user guide

Dragino G308 user manual

Dragino

Dragino G308 user manual

Data Domain DD690g Installation and setup guide

Data Domain

Data Domain DD690g Installation and setup guide

Raritan Laptop Release notes

Raritan

Raritan Laptop Release notes

Haivision Torpedo quick start guide

Haivision

Haivision Torpedo quick start guide

ATCOM AG-268 user manual

ATCOM

ATCOM AG-268 user manual

LST M500RFE-AS Specification sheet

LST

LST M500RFE-AS Specification sheet

Vega VEGA BS-3 user manual

Vega

Vega VEGA BS-3 user manual

Kinnex Media Gateway quick start guide

Kinnex

Kinnex Media Gateway quick start guide

2N Telekomunikace 2N StarGate user manual

2N Telekomunikace

2N Telekomunikace 2N StarGate user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

A product of PHYTEC Technology Holding Company

L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit
Hardware and BSP Manual






L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
2
L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
Document Title L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
Document Type BSP Reference Manual
Yocto Page https://www.phytec.de/documents/l-813e-6-yocto-reference-manual/
Article Number L-1012e.A3
Release Date 02.08.2022
Is Branch of L-1012e.Ax phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual Head
L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
3


L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
4
L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
5
1 Notes about this Manual
1.1 Usage
The information in this manual is valid for all standard variants of the phyGATE Tauri-S industrial gateway from
PHYTEC Messtechnik GmbH. An overview of all devices and variants to which the descriptions apply can be found in
Product Information.
Before using the document, please check whether it also corresponds to the latest version. The latest version of the
manual and other technical documents can be found in the download section of this device's product page at
https://www.phytec.de/produkte/fertige-geraete-oem/phygate-tauri/#downloads/.
1.2 Symbols
The manual uses various symbols to indicate helpful and safety-critical notes. Below you will find an explanation of
each symbol's meaning.
1.3 Abbreviations (reserved, will be continued in next version)
Warning
For proper installation and safe operation of the device, the operating instructions and in particular the
safety instructions contained therein must be carefully read and observed.

Warning
This symbol indicates safety-critical information. The warnings must be observed!

Tip
This symbol indicates general notes and helpful information in handling the device.

L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
6
•
•
•
•
2 Safety Instructions and Liability
2.1 Intended Use
The phyGATE Tauri-S gateway is designed for monitoring, processing, and communicating machine and sensor
data in industrial environments. For data communication, the devices provide various typical industrial interfaces
for connection to surrounding devices.
This PHYTEC standard gateway is supplied exclusively as an OEM device by PHYTEC Messtechnik GmbH and
requires an adaptation of the operating software for the intended application by the distributor of the device.
2.2 General Safety Instructions
For commissioning, development work, and assembly, the operating instructions for the device must be used.
Knowledge in the following areas is required:
Electronic circuitry
Working in electrostatically protected areas
Accident prevention regulations
On-site valid rules and regulations for occupational safety
These devices may only be commissioned and installed by adequately qualified personnel with basic electrical
knowledge! The device must be handled with care in every phase of its life cycle, in order to prevent destruction by
electrostatic discharge or mechanical stress, for example.
To ensure functional safety, the device must be powered by a SELV/PELV power supply. The gateway must be
mounted on a top-hat rail in a fire save control cabinet for permanent use.
Improper modifications and repairs may impair the integrated protective functions and the electromagnetic
behavior of the device. This can cause malfunction of the device, interference with connected and surrounding
devices, or personal injury. Therefore, interventions on the device may only be carried out by the manufacturer.
Warning
The device must not be used in a manner not specified in this manual to avoid damage of the protection
provided by the equipment.
L’appareil ne doit pas être utilisé d'une façon non spécifiée dans ce manuel afin éviter d’endommager la
protection fournie par l'équipement.

Warning
To ensure functional safety, the device must be powered by a SELV/PELV power supply. The gateway must
be mounted on a top-hat rail in a fire save control cabinet for permanent use.
Pour garantir la sécurité fonctionnelle, l’appareil doit être alimenté par une alimentation SELV/PELV. Pour
une utilisation permanente, la passerelle doit être montée sur un rail profilé chapeau dans une armoire de
commande coupe-feu.

L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
7
2.3 Disposal
The operator of these devices must ensure that there is no danger to persons or property in the event of a defect or
malfunction of the device. In case of non-repairable defects and device malfunctions, the devices must be taken out
of operation and disposed of properly.
2.4 Liability
Improper use and connection of these devices, as well as subsequent processing of these devices (e.g. soldering
work on the printed circuit board), lead to exclusion of liability on the part of the manufacturer. Please observe the
corresponding information in the operating instructions for proper installation.
Warning
The device must not be disposed of in household waste!


L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
8
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3 Product Information
3.1 Product Names and Variants
The phyGATE Tauri-S gateway is available in different variants and expansion stages, which differ in the scope of
performance and functions. The following table gives an overview of available variants of the gateway and an
explanation for the identification of the article number.
TABLE 1: phyGATE Tauri-S Variants
Parent Product Article Number Technical Features
phyGATE Tauri-S Gateway
PB-03513-001.Ax
2x Ethernet
1x USB
1x MicroSD Card
Temp-Sensor
TPM
1x CAN
1x RS485
1x RS232
25mm housing
PB-03513-002.Ax
2x Ethernet
1x USB
1x MicroSD Card
Temp-Sensor
TPM
1x CAN
1x RS485
1x RS232
mPCIe slot (USB only) with 2x
SMA antenna connector
50mm housing
3.2 Product Overview
3.2.1 phyGATE-Tauri Gateway (25 mm housing)
The phyGATE Tauri-S has several interfaces and controls/displays which are shown in the following figure.
Picture of phyGATE Tauri-S with 50mm housing (reserved, will be added in next revision)
Note
The article numbers have an index ".Ax" where x determines the product revision.

L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
9
FIGURE 1: phyGATE Tauri-S Interfaces
TABLE 2: phyGATE Tauri-S Interface List
PB-03513-001.Ax
(25mm housing)
PB-03513-002.Ax
(50mm housing)
Controls/Displays
X X 1. Power-LED green
X X 2. User-LED red (freely configurable)
X X 3. User-LED yellow (freely configurable)
X X 4. Button (freely configurable)
X X 5. USB interface (Typ A)
X X 6. Ethernet interface (RJ45)
X X 7. Micro-SD Slot
X X 8. RS232, RS485, CAN interface (configurable)
X X 9. Supply connection
L-1012e.A3 phyGATE-Tauri-S i.MX 6UL/ULL Kit Hardware and BSP Manual
© PHYTEC Messtecknik GmbH
10
X X 10. Boot-Switch (Concealed, on opposite housing side)
X X 11. Air vents
X X 12. Extension interface under a top-hat rail and top-hat
rail clip (35mm)
X (13.) SMA antenna connectors
X (14.) Internal miniPCIe slot (USB only)
X (15.) SIM card socket
3.3 Nameplate
The nameplate of the phyGATE Tauri-S gateway is located on the side of the housing. Here you will find the
essential information about your device.
Illustration of phyGATE Tauri-S nameplate (reserved, will be added in next revision)
3.4 Technical Data
TABLE 3: phyGATE Tauri-S Technical Data
Electrical Data
Power supply voltage
min. 12 VDC (-10 %)
typ. 24 VDC
max. 36 VDC (+10 %)
Power consumption max. 200 mA @ 24 VDC
Power adapter type SELV/PELV
Hardware Specification
CPU type NXP i.MX 6ULL Cortex-A7
RAM 512 MB
eMMC 8 GB