Pisector GSM-01 User manual

Wireless GSM Alarm System
(GSM-01)
User Manual
Profile
For a better understanding of this product, please read this
user manual thoroughly before using it.

I. Features
1. GSM 900/1800/1900 bands, can be used all o er the world.
2. 3 zones for wired detectors and 16 zones for wireless detectors.
3. Set arm, disarm, emergency alarm by remote controller.
4. Set arm, disarm, monitor, output by calling the host.
5. Set arm, disarm, monitor, output by sending SMS.
6. Monitor en ironment on the spot.
7. Voice and message alert.
8. 5-group phone + room number; 1 group alarm monitor center
phone.
9. 2-group phone to report alarm and non-alarm status.
10. Can program 7-group alarm messages.
11. Easy to set ON or OFF for e ery wired or wireless detector.
12. 1 relay output to trigger camera when alarm.
13. 2 output for home appliances connection (lamp, cooker, air
condition).
14. SMS alert for external power failure or reco ery.
15. Built-in battery ensures normal work e en power failure.

II. Installation
1. Host
a.
Insert SIM card in alarm system
Press the yellow point on the unit with a pencil tip or other tools, SIM
card tray will come out. Put the SIM card into the tray and make sure
the Metal contacts of the card to be downwards, and then push the
tray back.
Before inserting SIM card in the alarm unit, using a regular mobile
phone do the following steps:
---Set PIN code request to off
---Delete all stored numbers
b. onnect the antenna
Screw the antenna to the unit carefully; do not o er-tighten the nut
or lea e it too loose!
c. onnect the power supply
Plug the alarm system into power and turn on the power switch. The
signal status LED on the unit will turn red and last for 20 seconds. This
shows it’s waiting for wireless detectors to be coded into the unit. Then
the status LED will turn orange with flash, indicating the unit is checking
the SIM card and searching for GSM network. After checking, if the LED
changes to green with slow flash, it shows phone numbers ha e been
sa ed in the unit, and the unit is now in “Arm” status. If the LED keeps in
green, it means phone numbers ha e not been sa ed in the unit, and
the unit is in “Disarm” status, you can call in or send SMS to program
the phone numbers.

LED status explanation
LED LED Status System working status
POWER
Off
Hasn’t turned on the switch; hasn’t
connected the power; no power in built-in
battery
Red power supply is normal
ST
AT
US
Power
on
Red Ready to code wireless sensors
Orange (flash slowly) Check SIM card and search GSM network
Green (flash slowly) SIM card and GSM signal are normal; ha e
stored numbers in SIM card; in arm status
Green ha e not stored numbers in SIM card; in
disarm status
Normal
working
Red (flash slowly) In alarm status
Red (flash quickly) Remote controlled by SMS commands or
phone
Green Disarm
Green (flash slowly) Out Arm
Green (flash quickly) Home Arm
MONITOR
On Can monitor the scene when alarming, but
the siren will not ring
Off Can not monitor the scene when alarming,
but the siren will ring
ALARM
On The siren will ring when alarming
Off The siren will not ring when alarming
d. onfiguration of the alarm unit:
There are 10 connect ports at the top side of the unit:
(GND; SIREN; RELAY1; RELAY2; O3 (SPEAKER); O2; O1; I3; I2; I1):
GND: power ground.
SIREN:
Connect the black wire to GND port and the red wire to siren port.

I1, I2, I3:
onnect wired sensors
Three inputs are a ailable to connect wired sensors. Inputs are
independent and not coded as different zones. When these sensors are
triggered, the unit will sent SMS message:
Wire Activate (1~3).
Sensors can be NO (normally Open) or NC (normally Close) type.
More than 1 sensor can be connected to one input: connect their alarm
contacts in series. The number of the sensors is not limited as long as
the total resistance is under 220 ohms.
O1, O2:
These 2 ports for output, you can call in or send SMS to set them. If
output of these goes high, the light of OUT 1 or OUT 2 will light on the
panel. (non-specialist should use it with caution!!)

O3 (SPEAKER):
This port is for oice output, it can be connected to the speaker. The
other port of the speaker is to connect to ground. You can control it by
call in or send the SMS.
RELAY1, RELAY2:
These two ports will close 3 minutes when alarm happens. You can use
these two ports to start the power supply of the camera when alarm
happens, also you can disable this function by setting command 16#1#,
you can also make this relay close or open anytime by sending SMS or
dialing (94#1# or 94#0#).
Wiring Explanation: For home-appliance control (for special order)
The controller box has four wires:
i). Two yellow AC 220 wires to be connected with Home appliance.
ii). GND, +12V DC wires to be connected with a 12V DC (Power
supply)
NOTE:
Try to install the main panel in the center of defense zone and pull
out the antenna to get longer wireless recei ing distance.
Installation position should be far away from huge metal objects
and wireless interference.

2. Door sensor
Door sensors are used for detecting the status of open and close of
windows and doors. It will detect it and send the signal to main panel.
1. Tear apart the double-side adhesi e tape on the magnet and the
transmitter. Then adhere them to the appropriate position.
2. Magnet should be near to the side of transmitter with indicator.
The two should align with each other and the distance should not
exceed 10mm.
3. Please plug out the antenna
for better signal.
4. If the low-power indicator is on,
please change the battery.
3. Wireless PIR detector
PIR detectors are used to detect the mo ement within a certain range.
Fix the adjustment bracket on the wall with the pro ided screws
and attach the detector to the bracket. It is recommended to
mount it at a height of 2-2.2m abo e the floor.
Effect of the PIR detection is best when the detection direction is
in 90°angle with the walking direction of the intruder. Choose the
most suitable installation place and angle according to actual
situation and taking the following installation diagram as reference
to ensure the detection effect is best.
Please do not fix it under direct sunlight or other strong lights and
also keep it away from places with frequent strong air stream.
If the low-power indicator is on, please change the battery.

III. Set alarm phone numbers
You can send message to the unit to set 5 alarm phone numbers and 7
alarm SMS.
The command format: password #operation code # content #
1. Sa e the alarm phone numbers.
123456#5X# alarm phone numbers #. (X = 1 to 5)
Sa e 5 group alarm phone numbers into the base.
For example: 123456#51# 13905950001#
Sa e the 1st alarm phone number 13905950001 into the base.
2. There are 7 default SMS contents in the base, but you can change it.
When the wireless detector in zone 01 to 05 is triggered, the default
SMS content will be: Wireless Acti ated (X); X can be 01 to 05.
For example:
if detector in zone 01 is triggered the SMS will be:
Wireless Acti ated (01)
When the wireless detector in zone 06 to 16 is triggered, the default
SMS content will be:
Wireless Acti ated (X); (X=06-16)
When the wire detector is triggered, the SMS message will be: Wire
Acti ated (X);(X=1-3), for port 1 to 3 alarm

3. You can send SMS commands to rewrite the abo e 7 kinds of SMS
contents, e ery SMS cannot excess 24 English characters.
123456#8X# SMS content #. (X = 1 to 5)
For example:
Rewrite the 1
st
SMS content into “Middle door open”:
123456#81#Middle door open#
Rewrite the 6
th
to 16
th
SMS content into “Middle window open”:
123456#86# Middle window open#.
Rewrite the wire detectors SMS content into “Back window open”
123456#87# Back window open#.
IV. Test the host alarm
When you start the base, if the base is in Disarm status, the signal LED
keep still green, you can use controller to change the base into Arm
status, or you can send SMS (123456#1#1#) to the base to change the
base into Arm status, the signal LED will change to flashing green.
1. Under Arm status, with green LED on, any port of input (I1, I2, I3)
short circuit or disconnected, or any wireless detectors has been
acti ated, or you press the emergency key on the controller, the
alarm system will send alarm information by SMS, and dialing out
stored telephone numbers.
2. It will send SMS before dial alarm phone numbers. If the SMS
function has been closed or limited, it will only dial out the preset
telephone numbers. You can make them disarm with remote
controller.
3. When there is alarm, it will dial out phone numbers, you can answer

the phone (not need input password) to operate it, press 3# 1# to
start the siren and press 3# 0# to stop it; press 4# 1# to listen-in and
press 4# 0# to stop it; press 93# 1# to talk with the spot and press
93# 0# to stop it.
4. When there is alarm, it will dial out phone numbers, you can
answer the phone(not need input password ),if you do not want the
unit to dial next phone numbers, just press 1# 1# or 1#2# to re-turn
the unit into Arm status.
5. When there is alarm, you can use the controller to change the
base into disarm status when you are in nearby can control the
situation.
6. When the external power is cut off, the system will send SMS
“Power changer off” to inform. When the external power
reco ered, the system will send SMS “Power changer on” to
inform.
V. ontrol the host
1. Send message to the host phone number (SIM Card number)
Send message to the unit: password 123456#, add the following
commands to control the unit;
2. Call the host phone number (SIM Card number)
Call in the unit and enter password 123456#, then input the following
command to set the base:

ommands table:
om Function om Function
1#1# Out arm*
(all detectors work)
1#2# Home arm
(part detectors work)
1#0# Disarm*(all detectors not work)
3#1# Siren Sounds
immediatel
3#0# Stop sounding
4#1# Start listen-in* Call the
alarm panel and then
input this command
4#0# Stop listen-in
Call the alarm panel and then
input this command
11#1# Need siren sound when
alarming *
11#0# No siren sound when
alarming
12#1# Send SMS when
alarming *
12#0# No SMS when alarming
15#1# Dial phone number
when alarming *
15#0# Just alarm and no dialing
16#1# Rela does not close for
3 Min when alarming
16#0#* Set Rela close for 3 Min
when alarm*
21#1# Siren rings when
pressing out arm
button*
21#0# Siren off when pressing out
arm button
22#1# Siren rings when
pressing home arm
button*
22#0# Siren off when pressing
home arm button
23#1# Siren rings when
pressing disarm button*
23#0# Siren off when pressing
disarm button*

27#(00-
99)#
Arm dela , 00-99: dela time (default: 10sec)
28#(00-
99)#
Alarm dela , 00-99: dela time (default: 00)
30## show the arm and disarm status of every zone
(SMS command applicable onl )
31#--# Change password. Enter a new password (1—6 bit).
38#--# Set arm of zone independentl (wireless zone: 1—16; wire zone:
21—23)
39#--# Set disarm of zone independentl (wireless zone: 1—16; wire zone:
21—23)
50## show preset phone numbers in the host
(SMS command applicable only)
51#--# First group phone
number(0—15bit)
52#--# Second group phone
number(0—15bit)
53#--# Third group phone
number(0—15bit)
54#--# fourth group phone
number(0—15bit)
55#--# Fifth group phone number(0—15bit)
80## show preset SMS in the host
81#--# Wireless zone 01
Message(0-24bit)
82#--# Wireless zone 02
Message(0-24bit)
83#--# Wireless zone 03
Message(0-24bit)
84#--# Wireless zone 04
Message(0-24bit)
85#--# Wireless zone 05
Message(0-24bit)
86#--# Wireless zone I
Message(0-24bit) (I=06-16)

87#--# Wired zone Message(0-24bit)
90## Show Output status in the host
91#1# Set Output 1 to high 91#0# Set Output 1 change to low
92#1# Set Output 2 to high 92#0# Set Output 2 change to low
93#1# Set talk to the host
available (Output 3)
93#0# Set talk to the host
unavailable (Output 3)
94#1# Set Rela to be
connected
94#0# Set Rela to be disconnected
95#1# Set alarm when input 1
open
95#0# Set alarm when input 1
connect to GND*
96#1# Set alarm when line
input 2 open
96#0# Set alarm when line input 2
connect to GND*
97#1# Set alarm when line
input 3 open
97#0# Set alarm when line input 3
connect to GND*
Note:
1. In the abo e table, ‘*’ stands for default setting.
2. Alarm delay is not workable for smoke detector, gas detector or
emergency button. That is, e en though this system is set as alarm
delay, triggering of the mentioned sensors will cause immediate
alarm without delay.
3. In alarm delay state, if any of the door sensor, PIR sensor or wired
sensor is triggered, the siren will ring once per 5-second. After the
delay time, the siren will keep ringing consecuti ely, and the panel
will send SMS and make alarm call.
4. For the abo e phone operation, one beep shows your input

successful, a long beep shows the sentence you input is
successful, two short beeps shows your input is failed, you should
try again.
5. In the abo e SMS operation, you will recei e a reply message for
confirmation after you send the message command to the base,
the replied message for example:
Disarm, Sms: ON, Phone: ON, Siren: ON, enter Tel: OFF, Arm
enter Tel: OFF, Disarm enter Tel: OFF
You will know the working state of the base then (arm, disarm or
alarm).
VI. Remote controllers
The remote controller has four buttons:
1. Out Arm:
Out Arm
mergency
Home Arm
Disarm

Press the “Out Arm ” button on the remote controller, the STATUS
indicator on the main panel flashes in orange; 10 seconds later, it will
turn green with slow flash. The system enters Out Arm mode, and all
the detectors will be in working status.
2. Home Arm:
Press the “Home Arm ” button, the STATUS indicator on the main
panel flashes in orange; 10 seconds later, it will turn green with fast
flash.
Detectors inside the house (in inner defense zone) will not work, only
the detectors outside the house (in outside defense zone) will work, so
that people inside can mo e freely, but others who break in from outside
will trigger the alarm.
3. Disarm:
Press “Disarm ” button, the system will enter into disarmed status,
the STATUS indicator on the main panel is green.
4. Emergency:
When there is an emergency, press the “Emergency ” button on the
remote controller, the system will alarm immediately no matter it is in
arm or disarm status.

VII. Add more detectors
You can add new sensors or detectors, such as wireless door sensors,
PIR Sensors, gas and smoke detectors into the unit.
1) Add sensors ready to work when you set both Out Arm and Home
Arm:
When the GSM host begins to be powered on, the status LED light on
panel will be red for 20 seconds, this is code learning mode. You can
trigger the sensors or detectors, and the red LED will flash to show it is
coded successfully into the host.
The coding mode ends 20 seconds later automatically, and system
enters into working mode, status LED light on panel will change to
yellow, then to green.
2) Add sensors into inner defense zone. (Detectors in this zone are
ready to work when you set Out Arm, and will not work when you set
Home Arm
When the GSM host begins to be powered on, the status LED light on
panel will be red. Push the reset button for one second, the status LED
light will light up in orange for 20 seconds. This is code learning mode
of inner defense zone. You can trigger the sensors or detectors, the
LED will flash in red to show it is coded successfully into inner defense
zone.
For abo e operation, the host will exit code learning mode 20
seconds later automatically, and enters into working mode, the light on

panel changes to orange to search for GSM network, then to green.
Note: If there were 4 wireless sensors in the host, they stand for zone 1
to zone 4, and then the new added sensor will be 5th zone in the host.
VIII. Delete detectors
In case of the coded sensors or detectors are lost, you can delete the
coded information of these detectors so that they can not control your
alarm system.
Keep pressing the reset button, then power on the system. One beep
sound or LED flashes, shows reset is successful. All registered
detectors ha e been deleted from the unit. You can register them again
with the abo e mentioned procedures. System reset will not change the
SMS message.
Basic Kit:
- Main Panel – 1 pc
- Wireless PIR detector – 1 pc
- Wireless door (gap) sensor – 1 pc
- Remote controller – 2 pcs
- Antenna – 1pc
- Mini wired siren – 1 pc
- Power adaptor – 1pc
- User manual – 1pc

The following sensors are optional:
Optional sensors/detectors are packed separately. You can
choose according to your specific requirements.

TE HNI AL PARAMETERS
Main Panel
Static current: 20mA
Power: 9V-12V DC
Working temperature:-10~ +40
GSM: 900/1800/1900MHz band
Recei ing code: ASK
Frequency: 433MHZ
Wireless distance: 100 M
Wireless detectors: 16
Wire detectors: 3
Wireless Gap Detector (Door/ Window ontact)
Power Supply: DC12V (inner 7.4V battery)
Static Current: ≤20 uA
Transmission Current: ≤15mA
Transmission Frequency: 433MHZ±0.5MHZ
Transmission Distance: No obstacle 80m
Internal Distance: 15 mm
Working Condition: Temperature –10~+ 40
Humidity ≤ 90% rh

Wireless PIR Detector
Power Supply: DC9V (inner 9V battery)
Static Current: ≤100 uA
Transmission Current: ≤20mA
Transmission Frequency: 433MHZ±0.5MHZ
Transmission Distance: No obstacle 80m
Detecti e Speed: 0.3 - 3m/s
Detecti e Distance: 5 - 12m
Detecti e Range: Horizontal 110° Vertical 60°
Working Condition: Temperature –10 ~+ 40
Humidity ≤ 90 rh
Remote ontroller
Power Supply: DC=12V~8.4(Inside A23 DC=12V dry battery)
Static Current: 0
Emission Current: ≤15 mA
Emission Frequency: 433±0.2 MHz
Emission Speed: T≤1 second
Emission Distance: no obstacle 80m
Working En ironment: Temperature -10℃~+40℃
Humidity≤90%
Other manuals for GSM-01
1
Table of contents
Other Pisector Security System manuals

Pisector
Pisector GSM-06 User manual

Pisector
Pisector GS08 User manual

Pisector
Pisector GS08 User manual

Pisector
Pisector GSM-03 User manual

Pisector
Pisector GSM-01 User manual

Pisector
Pisector P09 series User manual

Pisector
Pisector PS03 User manual

Pisector
Pisector PS03 User manual

Pisector
Pisector Motion sensor User manual

Pisector
Pisector GS08 User manual