Piusi MCO GO Specification sheet

Bulletin M0570 ITEN _ 00
Installation, use and maintenance | EN
Installazione, uso e manutenzione | IT
control
UNIT
MCO GO

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 25 /4 0
CONTROL unit MCO GO
EN
1. EU declaration of conformity .................................. 26
2. General warnings ................................................ 27
3. Safety instructions and warnings ............................. 28
4. First aid rules ..................................................... 29
5. General safety rules ............................................ 29
6. Device packaging ................................................ 30
7. Package contents/pre-inspection ............................. 30
8. Position of important information ............................ 31
9. Machine and manufacturer identification ................... 32
10. Technical specifications ........................................ 32
11. Intended use ..................................................... 33
12. Installation ........................................................ 34
13. Configuration ..................................................... 35
14. Maintenance ..................................................... 44
15. Demolition and disposal ........................................ 45
TABLE Of CONTENTS

26 /4 0
Installation, use and maintenance
M0570
1. EU DECLARATION OF CONFORMITY
The undersigned:
PIUSI S.p.A.
Via Pacinoi c.m. z.i. Rangavino
Suzzara - Mantova - Italy
HEREBY STATES
under its own responsibility, that the equipment described below:
Description: display and management device for processes and supply.
Model: CONTROL UNIT MCO GO
Serial number: refer to Lot Number shown on CE stamp on the product (refer to
page ).
Year of manufacture: refer to the year of production shown on the CE stamp on
the product (refer to page ).
is in conformity with the legal provisions indicated in the directives:
¦ Electromagnetic Compatibility Directive //EU
¦ Low-Voltage Directive //EU
¦ RoHS II Directive //EU
¦ RED Directive //EU
The documentation is at the disposal of the competent authority following
motivated request at PIUSI S.p.A. or following request sent to the email address:
doc_tec@piusi.com
The person authorised to compile the technical file and draw up the declaration
is Oo Varini as legal representative.
Suzzara, // Oo Varini
legal representative

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 27 /4 0
CONTROL unit MCO GO
EN
1.
To ensure operator safety and to protect the system from potential
damage, workers must be fully acquainted with this instruction
manual before aempting to operate the system.
The following symbols will be used throughout the manual
to highlight safety information and precautions of particular
importance:
Warnings
Symbols used
in the manual
2. GENERAL WARNINGS
This symbol indicates
a hazardous situation
which, if not avoided,
could result in death
or serious injury.
This symbol
indicates that there
is risk of damage to
the equipment and/
or its components.
This symbol
indicates useful
information.
WARNING ATTENTION NOTE
Manual
preservation
This manual should be complete and legible throughout. It should
remain available to end users and specialist installation and maintenance
technicians for consultation at any time.
Reproduction
rights
This manual belongs to PIUSI S.p.A., which is the sole proprietor of all
rights indicated by applicable laws, including, by way of example, laws on
copyrights. All the rights deriving from such laws are reserved to PIUSI
S.p.A.: the reproduction, including partial, of this manual, its publication,
change, transcription and notification to the public, transmission,
including using remote communication media, placing at disposal of the
public, distribution, marketing in any form, translation and/or processing,
loan and any other activity is reserved by the law to PIUSI S.p.A.
All reproduction rights are reserved by PIUSI S.p.A.
The text cannot be reprinted without the wrien permission
of PIUSI S.p.A.
© PIUSI S.p.A.
THIS MANUAL IS THE PROPERTY OF PIUSI S.p.A.
ANY REPRODUCTION, EVEN PARTIAL, IS FORBIDDEN.

28 /4 0
Installation, use and maintenance
M0570
SAFETY INSTRUCTIONS AND WARNINGS3.
Before proceeding, make sure that the mains power supply is equipped with
adequate grounding line in accordance with current standards.
Mains - preliminary
checks before
installation
The device may not operate correctly in the presence of particularly
intense electromagnetic interference.
WARNING
Before carrying out any inspection or maintenance operations, make
sure to disconnect the power supply by removing the plug from the
power socket, if it is connected.
Maintenance
control
It is strictly forbidden to hold or transport the system by means of the
cables connected to it.
Completely avoid contact between the electrical power supply and liquids
of any kind. Contact between electrical components and lubricating oil or
flammable liquids may cause fires or explosions.
The device is powered by a built-in baery pack. Incorrect use or aempts
at tampering may cause sparks, fire or explosion. In order to preserve its
integrity and safety, do not intervene on the baery pack.
Supplying the device using power sources other than the one built in is
expressly prohibited.
WARNING
WARNING
WARNING
Prohibitions

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 29 /4 0
CONTROL unit MCO GO
EN
GENERAL SAFETY RULES5.
Wear protective equipment according to the info below:
¦ suited to the operations that need to be performed;
¦ resistant to cleaning products.
Using the CONTROL UNIT MCO GO device does not require the
use of particular personal protective equipment.
In any case, wear equipment that is suitable for the work
environments where the device is used.
Within workshops, in any case, the following personal protective
equipment should be used:
Essential
protective
equipment
characteristics
FIRST AID RULES4.
People suffering
from electric
shock
Disconnect the power supply, or use a dry insulator to protect
yourself in the operation of moving the victim away from any
conductor. The victim must be moved away from any conductor
before touching him/her with bare hands. Seek immediate help
from trained and qualified people. Do not operate the switches
with wet hands.
Do not operate the device when tired or under the influence of drugs or alcohol.
Do not leave the work area while the device is operating. Turn off the device when not in use.
Ensure that the power cables are always far from transit areas, sharp edges, moving parts and hot
surfaces.
Do not alter or modify the device. Alterations or modifications to the device may invalidate its type-
approval and result in dangers to safety.
Keep children and animals far from the work area.
Observe all applicable safety regulations.
WARNING
Personal
protective
equipment that
must be worn Use
Instruction
Manual
safety
shoes
close-fiing
clothing
protective
gloves
safety
goggles

30 /4 0
Installation, use and maintenance
M0570
The electrical connection has to stay away from
water.
For safety reasons it is mandatory to use the
device with an RCD (maxmA).
Extension lead can be dangerous. It
recommends the use of extension cords and
appropriate use of adequate cross-section, in
accordance with regulations.
ATTENTION
7. Package contents/pre-inspection
6. Device packaging
The control device comes packed in a
cardboard box bearing a label containing all the
information relating to the equipment (model,
weight, etc.).
Power lead
(for switch)
Never touch electrical cables with wet
hands. Do not activate the device if the
mains connection cable is damaged.
Before each use, check that the mains
connection cable is not damaged. Have the
cable repaired immediately by a specialist
electrician.
WARNING
switch
CONTROL
UNIT MCO GO

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 31 /4 0
CONTROL unit MCO GO
EN
POSITION of important information
Adhesive labels showing the operator the
most important information are affixed to the
dispensing system. Check that these labels do
not deteriorate over time or come off.
8.
If all or part of the label deteriorates
or comes off, please contact our
customer care department to ask for a
replacement.
NOTE
Check that the data on the
plate correspond to the desired
specifications. In the event
of any anomaly, contact the
supplier immediately, indicating
the nature of the defects. Do
not use equipment which you
suspect might not be safe.
WARNING
To open the cardboard packaging, use a pair of scissors
or a cuer, being careful not to damage the dispensing
system or its components. Open the packaging and
check that the components provided as part of the
equipment are available.
In the event that one or more of the components
described below are missing from inside the package,
please contact PIUSI S.p.A. technical support.
NOTE
MADE IN ITALY
MCGO-01C5-36E7-015

32 /4 0
Installation, use and maintenance
M0570
1. MACHINE AND MANUFACTURER IDENTIFICATION
The device comes with an identification
stamp aached to the body and contains
the following information:
¦ lot number;
¦ type;
¦ product ID code;
¦ lot number / production year.
9.
Before installing, always make sure the
type of device is correct.
WARNING
10. TECHNICAL SPECIFICATIONS
The essential technical specifications of the CONTROL UNIT MCO GO device are:
CONTROL UNIT MCO GO
Touchscreen monitor dimensions 9"
Voltage 90-240 V
Operating temperature from -5°C to +40°C
Operating humidity from 10 to 90 R.H.%
Dimensions 283x197x55 mm
Weight 2.28 Kg

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 33 /4 0
CONTROL unit MCO GO
EN
INTENDED USE
11.
Intended use The CONTROL UNIT MCO GO device allows workshop
operators to display and manage work processes, with
interaction possible thanks to the touchscreen monitor.
The work process management activities require the entry of
a PIN that identifies the operator, so as to guarantee complete
traceability and accurate monitoring of access.
The device can also enable the opening of the fluid supply
control solenoid valves in the GPV 2.0 devices and installed
in the line in the workshop, so as to precisely control the
distribution of oil and other fluids.
Its functions allow a PRESET quantity to be set.
Conditions
of use
CONTROL UNIT MCO GO must be used in accordance with the
following conditions:
¦ operating temperature: -C / C;
¦ operating humidity: / RH;
Unintended use Do not operate the system for any purpose other than the purpose
described within this manual; all other use is considered “IMPROPER”
and will result in PIUSI S.p.A. disclaiming any responsibility for damage to
property, people, animals or to the system itself.

34 /4 0
Installation, use and maintenance
M0570
12.
Power supply ¦ Connect CONTROL UNIT MCO GO to the power supply;
¦ connect the Ethernet cable to the RJ port of the CONTROL UNIT;
¦ position and power the GPVs ;
¦ position and power the switch PIUSI ports;
¦ (option) position the Ethernet printer.
Wiring ¦ Wire the CONTROL UNIT to the switch PIUSI connecting the
Ethernet cable to one of the free ports of the switch;
¦ Wire the GPVs to the switch PIUSI connecting the Ethernet cable to
one of the free ports of the switch;
¦ (option) wire the printer PIUSI connecting the Ethernet cable to one of
the free ports of the switch;
What not to do ¦ Use a different switch from the one supplied by PIUSI;
¦ connect some GPVs already configured or coming from other plants,
without having first reset them to the factory values following the
procedure in the web screen of the GPVs (see dedicated manual of the
GPV 2.0);
¦ wire the devices using non-certified Ethernet cables (longer than
meters);
INSTALLATION
Foreword The CONTROL UNIT MCO GO device has been designed and made
for installation, on the wall, using the holes provided or the adjustable
bracket available as an accessory. In any case, a safe, stable fixing must
be guaranteed.
The device requires an electrical supply, so position it in an area that can
be safely reached from a power socket.
Authorised
installation
personnel
All installations must be carried out by authorised and competent
personnel only. Authorised persons must:
¦ install the system in dry and well-ventilated place;
¦ connect the device correctly to the mains.

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 35 /4 0
CONTROL unit MCO GO
EN
¦ connect to the switch PIUSI network devices not certified by PIUSI;
¦ connect more than GPVs to the Switch.
13.
To enable the CONTROL UNIT you need a 9-digit code "SUPER
MASTER CODE" that is provided aer registering the device on
the website portal.piusi.com.
Accessing with their own credentials, each user can register one
or more Control Units in their possession, by entering the serial
code that is located on the label, under the device.
First registration To register a new user on the PIUSI portal it is necessary to
access the website www.piusi.com, click on the PIUSI PORTAL
buon and then on "REGISTER"SIGNUP) to start the registration
of the new user on the portal.
Enter the product key (wrien on the label of the CONTROL
UNIT MCO GO body) and press "REGISTER" to proceed.
Aer registration, you will receive a confirmation email with all
the information you need to access your area on the Piusi portal,
an email containing the 9-digit SUPERMASTERCODE to be
entered when you turn on the CONTROL UNIT MCO GO and
an email with the account code of the CLOUD MCO GO service
trial version valid for 3 months (the account code is provided
only when you register the first device: for each other registered
device only the SUPER MASTER CODE will be sent).
MCGO-01C5-36E7-015
CONFIGURATION

36 /4 0
Installation, use and maintenance
M0570
Registration of a
new device
If you already have an account on the Piusi portal, follow the steps
below to register the new ‘PRODUCTKEY’ of the CONTROL UNIT
MCO GO:
Access the portal and enter the section “MCOGOADDLICENCE”.
Enter the PRODUCTKEY of the CONTROL UNIT to be registered and
the details of the dealer where you purchased it. Click “REGISTER” to
register the product.

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 37 /4 0
CONTROL unit MCO GO
EN
In case of loss of the
SUPER MASTER CODE,
there is no automatic
recovery procedure:
contact the service so
that a new one can be
provided.
NOTE
Aer registration, an e-mail will be sent containing the
9-digit SUPERMASTERCODE to be entered when you
turn on the CONTROL UNIT MCO GO (one SUPER
MASTERCODE for each registered CONTROL UNIT
MCO GO).
Also from the portal, once all devices have been
registered, by accessing the "MCOGOPRODUCT
LIST" area you can view all the products that have
been registered, view the data of the active CLOUD
LICENSE, login to the CLOUD Soware and download
any updates available for the CONTROL UNIT MCO
GO.

38 /4 0
Installation, use and maintenance
M0570
Operation Turn on the CONTROL UNIT while
holding down the power buon.
CONTROL UNIT
MCO GO
AAt the first start you must enter the SUPER MASTER CODE received by
e-mail aer registering the control unit on the portal.
activation
power
Interrupt supply immediately
if there are sparks or electrical
discharge.
WARNING

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 39 /4 0
CONTROL unit MCO GO
EN
BConfigure the parameters according to your preferences,
being careful to configure the correct date, time and time
zone. Press “NEXT” to continue.
CChoose how you want to configure the CONTROL UNIT. There
are two ways: you can start with a new configuration ("NEW
CONFIGURATION") or otherwise, if you have a backup of a previously
used CONTROL UNIT, you can restore its configuration ("IMPORT
FROM BACKUP").

40 /4 0
Installation, use and maintenance
M0570
CHOICE 1 - new configuration
DEnter the device name and workshop name. These two values will be
useful to differentiate the data coming from your device in the CLOUD
SOFTWARE MCO GO.
The field "Workshop Name" is required Press "NEXT" to go to the next
configuration.
AND If you want you can change the PIN code of the manager (by default
always 123456). Press "NEXT" to end the configuration.

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 41 /4 0
CONTROL unit MCO GO
EN
CHOICE 2 – restore configuration from backup
FThe configuration is complete. If you want to start using the system
immediately press the "START" buon; otherwise, if you want to
proceed with the automatic procedure detecting the GPVs in the
system, activate the item "Discovery GPV now".
DTo start the restore procedure for a
previous configuration from backup,
insert a USB key in the CONTROL
UNIT with the last backup to
be restored loaded inside. The
procedure start automatically as
soon as a backup file is detected.
If there are multiple
configuration backups on the
USB key, the procedure will
restore the most recent backup
on the key.
NOTE

42 /4 0
Installation, use and maintenance
M0570
AND If the backup is successfully restored, the configuration is complete.
Press "START" to start using the MCO GO system.

This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden. 43 /4 0
CONTROL unit MCO GO
EN
¦ CONTROL UNIT MCO GO is for professional use only.
¦ It is mandatory to provide the electrical connection for the device in observance of the
current regulations in the installation location.
¦ It is mandatory to adhere completely to the safety and fire regulations in force in the place
of installation.
¦ The CONTROL UNIT MCO GO device has been designed for use in a dry environment. If
it is installed outside, provide adequate protective covering.
ATTENTION
Altering or modifying the device is strictly forbidden. PIUSI S.p.A. accepts no responsibility
for damage to persons, property or the environment caused by failure to comply with this
requirement.
The installer is responsible for equipping the system with the required accessories for safe
and correct operation of the device. The selection of accessories unsuitable for use may
cause serious damage/injury to the device and/or individuals.
Do not use the device if important parts of the device, accessories or safety devices are
damaged. Make the necessary replacements and repairs immediately.
WARNING
Table of contents
Other Piusi Control Unit manuals