PKP DG04 User manual

Instruction Manual
DG06
Sight Flow Indicator
with flap and scale
PKP Prozessmesstechnik GmbH
Borsigstraße 24
D-65205 Wiesbaden- ordenstadt
Tel.: ++49-(0)6122-7055-0
Fax: ++49-(0)6122-7055-50
Email: info@pkp.de

Table of Contents
Safety Information..................................................................................................................2
Functional description............................................................................................................3
Maintenance and care...........................................................................................................3
Safety Information
General Instructions
To ensure safe operation, the device should only be operated according to the specifica -
tions in the instruction manual. The requisite Health & Safety regulations for a given
application must also be observed. This statement also applies to the use of accessories.
Every person who is commissioned with the initiation or operation of this device must have
read and understood the operating instructions and in particular the safety instructions!
The liability of the manufacturer expires in the event of damage due to improper use, non-
observance of this operating manual, use of insufficiently qualified personnel and unau-
thorized modification of the device.
roper Usage
The devices of the DG06 series are used for the optical control monitoring of liquids. Any
other use of the device is prohibited and outside the scope of application.
In particular, applications in which shock loads occur (for example, pulsed operation)
should be discussed and checked in advance with our technical staff.
The devices of the DG06 series should not be used as sole monitoring devices in order to
detect or even avoid dangerous operating states in plants and machines. The plant or
machine itself must be planned and constructed in such a way that critical conditions
which pose a danger to man and the environment are excluded from the outset
Dangerous substances
For dangerous media such as e.g. Oxygen, Acetylene, flammable or toxic substances as
well as refrigeration systems, compressors, etc. must comply with the relevant regulations
beyond the general rules.
Qualified ersonnel
The devices of the DG06 may only be installed by trained, qualified personnel who are
able to mount the devices correctly. Qualified personnel are persons, who are familiar with
assembling, installation, placing in service and operating these devices and who are suit-
ably trained and qualified.
DG06 Instruction manual 04/2019 page 2

Inward Monitoring
Please check directly after delivery the device for any transport damages and deficiencies.
Additional with reference to the accompanying delivery note the number of parts must be
checked.
Claims for replacement or goods which relate to transport damage can only be considered
valid if the delivery company is notified without delay.
Functional description
The mechanical flow indicator DG06 is used for the optical control of flows and liquid
media. A stainless steel flap arranged in the flow chamber is lifted by the media flow.
Attention:
The DG06 is not a flow meter. It only indicates the presence of a flow. The numbers on
the scale cannot be assigned to a flow value. They only serve to indicate a certain flow
trend.
Maintenance and care
Due to the small number of moving parts, the units require very little maintenance. How-
ever, regular functional checks and maintenance not only increase the service life and
functional reliability of the device, but also that of the entire system.
The maintenance intervals depend on:
•contamination of the medium
•environmental conditions (e.g. vibrations)
DG06 Instruction manual 04/2019 page 3

Flow Measurement and Monitoring
DG06
Sight Flow Indicator
with Flap and Scale
•for liquids
•robust design
•cast steel or stainless steel
version
•for nominal sizes from /4“ to 4“ ,
with threaded fitting or flange
•available with PN 6 or PN 40
pressure ratings
•externally attached numerical scale
indicates approximate flow volume
•max. temperature: 250 °C
Description:
The DG06 flow indicator allows visual and quantitative moni-
toring of liquid flows. The device has two large glass panes –
one on each side – and each with a scale attached.
A stainless steel flap mounted in the flow chamber is lifted
when there is flow and the current flow rate is displa ed on
the scale. The flap is mounted on a stainless steel shaft; it is
raised b flow and lowered b gravit . The DG06 can be
installed both horizontall and verticall (with flow from bottom
to top) and deplo ed in a wide variet of applications – not
least because it is not adversel affected b high tempera-
tures.
Typical applications:
This flow indicator provides visual and quantitative monitoring
of liquids. There is potential for a m riad of applications in the
fields of industrial machiner and process control, as well as
basic monitoring of cooling units etc.
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
[email protected] • www.pkp.de
20210430

Models:
All devices have a flap made of AISI 316 stainless steel
and PTFE seals.
DG06.S: housing made of cast steel
ASTM-A-216-2000-GR-WCB
DG06.E: housing made of st. steel AISI 316
Other materials: on request
The sight flow indicator DG06 are available with borosilicate
glass (PN 16) or soda-lime glass (PN 40) .
We suppl t pe G or NPT threaded fittings or DIN or ANSI
flanges as process couplings.
Flow rates:
ominal sizes Approx. flow rates [l/min] *
2 4 6 8 10 Max.
DN 08 / 1/4“ 2,5 3,5 4,5 7 22 100
DN 10 / 3/8“ 2,5 4 4,5 7 24 150
DN 15 / 1/2“ 3 4,5 6 8,5 20 250
DN 20 / 3/4“ 3 5 6 9 20 250
DN 25 / 1“ 3,5 6 8 10 25 250
DN 32 / 1 1/4“ 7 11 14 24 40 550
DN 40 / 1 1/2“ 8 12 15 25 50 600
DN 50 / 2“ 9 15 28 50 75 1000
DN 80 / 3“ 24 32 52 128 220 -
DN 100 / 4“ 46 70 100 150 220 -
* The quoted flow rates for flap positions 2–10 are approximate values
onl ; the ma var considerabl , depending on installation position and
process conditions. The “Max.” value is the maximum flow volume at
which the flow indicators can operate (regardless of head loss) without
being damaged.
Dimensions:
ominal sizes Length [mm] Width
[mm]
Height
[mm]
Weight [kg]
G* F* G* F*
DN 08 / 1/4“ 95 140 89 66 1,9 3,7
DN 10 / 3/8“ 95 140 89 66 1,9 3,8
DN 15 / 1/2“ 95 140 89 66 1,85 3,9
DN 20 / 3/4“ 95 140 89 66 1,85 3,9
DN 25 / 1“ 95 140 89 66 1,8 3,9
DN 32 / 1 1/4“ 120 180 120 89 4 7,1
DN 40 / 1 1/2“ 120 180 120 89 3,9 7
DN 50 / 2“ 150 220 170 110 9 14,5
DN 80 / 3“ -- 258 160 165 -- 19,5
DN 100 / 4“ -- 258 160 165 -- 23,5
*) G = threaded, F = flanged
Larger nominal sizes on request
Order Code:
Order number: DG06.
Sight flow indicator
with flap and scale
S. B. G. 15. 0
Materials:
S = cast steel
E = stainless steel
Glass / pressure rating:
B = borosilicate glass / PN 16
N = soda-lime glass / PN 40
Process connection:
G = female thread G
N = female thread NPT
F1 = DIN-flange PN 16
F4 = DIN-flange PN 40
(with soda-lime glass onl )
A1= ANSI-flange, 150 lbs., RF
A3= ANSI-flange, 300 lbs., RF
(with soda-lime glass onl )
ominal sizes:
08 = 1/4" / DN 08
10 = 3/8" / DN 10
15 = 1/2" / DN 15
20 = 3/4" / DN 20
25 = 1" / DN 25
32 = 1 1/4" / DN 32
40 = 1 1/2" / DN 40
50 = 2" / DN 50
80 = 3“/ DN 80 (flange version onl )
100 = 4“/ DN 100 (flange version onl )
Options:
0 = without
1 = please specif in plain text
Technical Data:
Max. pressure: 16/40 bar, depending on t pe of glass
and process connection
Max media-
temperature: 250 °C
Materials
Housing: cast steel or stainless steel 1.4408,
ASME 316, ASTM – 351 CF8M
Glass: borosilicate glass or soda-lime glass
Flap: stainless steel
Gasket: PTFE
Scale: Pol carbonate
Installation
position: horizontal or vertical (onl with
upward flow)
PKP Prozessmesstechnik GmbH
Borsigstr. 24 • D-65205 Wiesbaden
S +49 (0) 6122-7055-0 • T +49 (0) 6122 7055-50
[email protected] • www.pkp.de
Flow