A. PRESENTATION
Firstly we would like to thank you for purchasing this product. Your business is much appreciated
and we trust that this equipment will provide many years of use and deliver full satisfaction. Before
proceeding to the installation, you should read all the instructions and recommendations detailed in
this instruction manual, since the manufacturer will not be responsible for any breakdown or damage
caused by misuse. Once your electric radiator is installed, keep this manual in a safe place so that it
can be consulted at any time.
B. RECYCLING
Warnings for the correct disposal of the product as established by the European Directive
2012/19 / EU. At the end of its useful life, the product should not be disposed of together
with urban waste. It can be delivered to specic recycling centres or to distributors that
can facilitate this service. Removing a household appliance separately means avoiding
possible negative consequences for the environment and health resulting from improper
disposal and recycling of the materials and components, thus obtaining signicant savings
in energy and resources. To underline the obligation to collaborate with a selective collection, the pro-
duct shows the marking that this product includes warning signs to conrm the non-use of traditional
disposal methods.
For more information, contact your local authority or the store where you purchased this device.
C. IMPORTANT SAFETY NOTES
The installation of the heating device must be chosen correctly and must
be carried out according to the rules and in accordance with the installation
guides included in the manual.
The equipment should be kept away from any ammable objects and chil-
dren should not be left near the appliance without being supervised. Chil-
dren under 3 years of age should be kept out of the reach of the appliance
unless they are continuously supervised.
Children from 3 years old to 8 years of age should only switch the applian-
ce on / o as long as it has been placed and installed in its normal opera-
ting position.
They must also be supervised or have received instructions regarding the
use of the appliance in a safe and secure manner and understand the risks
of a heating device.
Children from 3 years old to 8 years old should not plug, operate, clean or
perform maintenance operations.
This device can be used by children aged 8 years and above including peo-
ple with reduced physical, sensory or mental abilities or lack of experience
and knowledge providing they have been given appropriate supervision or
training regarding the use of the device in a safe manner and understand
the dangers involved. Children should be supervised to ensure they do not
play with the device.

3
Cleaning and maintenance to be performed by the user, should not be per-
formed by children without supervision.
Caution: some parts of this product can get very hot and cause bur-
ns. Particular attention must be paid when children and vulnerable
people are present.
The equipment must under no circumstances be covered by clothing, or
any other object, nor placed under a cabinet or any other obstacle that pre-
vents the circulation of hot air.
WARNING:
To avoid overheating, DO NOT COVER the heating
appliance.
The heating appliance must not be placed immediately below a socket outlet.
If your radiator is a dry type, it can be connected only to a supply with sys-
tem impedance no more than 0,24 Ω. In case necessary, please consult
your supply authority for system impedance information.
Avoid the use of extension cords as these can cause overheating and cau-
se a re risk. However, in case of using an extension cord, the cable must
be the minimum size 14 AWG and with a power no less than 2500w.
The connecting cables of the heater itself must not come into contact with
the surface of the appliance, and in the event that they can come into con-
tact with each other, they must be protected with an insulating cover having
an adequate temperature level.
The equipment must not be installed in places where there is a risk of
splashing water, such as bathtubs, washbasins, etc.
The equipment must be installed so that the switches, thermostat, out-
let cannot be touched directly or indirectly by a person in the bathtub or
shower (respect the distances of prohibition according to RBT).
In case the power supply cable is damaged, it can only be replaced by the
Technical Assistance Service, in order to avoid risks.
Always respect the safety measures when xing the device on the wall.
The electrical installation must have a switch with a fuse and magnetic protection.

4
Likewise, a dierential protection against ground faults is advisable. The
voltage and frequency values of the electricity network must be the same
as those indicated on the nameplate.
It is possible that the radiator may produce slight noises at the beginning of
its operation which is normal due to the expansion and contraction of alu-
minium. With a few times of operation, the noise should disappear.
D. INSTALLATION
BEFORE INSTALATION
The installation and start-up of this device is extremely simple, however you should read very care-
fully all the instructions and recommendations detailed in this instruction manual, as the manufactu-
rer will not be held responsible for any damage caused by non-compliance.
Once unpacked the device, the remains of the packaging must be removed in a responsible manner
since all the elements have been designed for recycling. If, once unpacked, it detects apparent da-
mage to the appliance, you should consult your supplier before proceeding with the installation and
electrical connection within a period of less than 24 hours.
Assembly and installation must be carried out following the instructions detailed in this manual.
For safety reasons, the transmitter should not be installed so that switches and other controls can
be touched by a person in the bathroom or in the shower.
VERY IMPORTANT!
• Read the installation manual before assembling the equipment.
• Read the user manual to operate the equipment.
• Observe the warnings carefully.
• Install the equipment in a place where the air can fully circulate.
• It is advisable to be assembled by an individual with DIY skills or qualied electrician.
ELECTRIC CONNECTION
• If you decide to remove the 3 pin plug from the power cord then you must follow the instructions
below regarding the electrical installation and the connection must be made by a qualied installer.
• If the electrical connection is spurred to a mains electric supply then it must be installed in accor-
dance with the installation regulations in force in the country in which it is to be tted.
• For safety reasons, verify that there is no voltage in the network prior to connecting the device to
the mains.
• Before connecting the appliance to the mains it must be ensured that the supply voltage is within
the indicated on the nameplate 230V.
• The device must be connected to the protective conductor of the xed installation.
• Any incident arising from the breach of these instructions will invalidate the guarantee.
• For the electric connection please take close note of the electrical diagram with special attention to
the colours of the cables.
• If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or by
a similar qualied personal so that the user is not in danger.

5
ELECTRIC WIRE
WALL MOUNTING
Together with the issuer, we provide an installation kit consisting of the following elements:
• Fixing brackets.
• Template.
• Screws and xing plugs.
Follow the following steps (graphics are attached):
1. Remove the radiator from its packaging (unpack at the top) and choose where to hang it taking into
account the minimum distances required around the emitter.
2. Use the guide included in the box to help. It is necessary to previously perforate the template in
the marks.
3. Using the holes as a guide, mark the necessary holes. We suggest you use a level to ensure that the
radiator is positioned correctly.
4. Using a drill, make the holes for the plugs appropriate to the type of wall.
5. Screw the xing brackets to the wall.
6. Place the radiator in the brackets, and x it using the screws provided for safety.
The radiator should always be xed to the wall.

6
WARRANTY
The manufacturer produces high quality products for international markets. The company provides a
guarantee for the period of 5 years and 2 years on electrical and electronic components. For this warran-
ty to be valid you must present the original invoice, delivery note or receipt.
- The guarantee only covers manufacturing defects and/or any problem occurring from such defects. All
problems arising from installing an undersized heater (not enough heat, improper installation, etc) are
not covered by this guarantee.
- This heater is for domestic & light commercial use only; installation in any another enviroment voids this
guarantee.
- Company reserves the right to decide whether to repair or replace any defective part or to replace the
entire heater.
- All costs arising from any damage caused by incorrect usage, transport, electrical supply are not cove-
red by this guarantee, nor are any malicious damage.
This guarantee does not provide compensation for incidental or consequential damage or injuries.
E. TECHNICAL CHARACTERISTICS
Temperature measurement resolution 0,1ºC
Slogan temperature increments 0,5°C
Measuring range ambient temperature 0°C - 45°C
Temperature selection range 5°C - 35°C
Weekly schedule Each 1h
Maximum load (resistive only) 16A TRIAC
8 A. (2000W)
Supply voltage 230 Vac +/- 10% 50 Hz
RF 868Mhz
Operating temperature <70ºC
Consumption error measurement <3%
Norms and directives:
The thermostat has been designed in accordance with
the following European standards and directives.
EN 60730-1 : 2013
EN 61000-6-1 : 2007
EN 61000-6-3 : 2007
EN 61000-4-2 : 2009
2006/95/EC low voltage
EMC 2004/108/EC
ENERGY SUPPLY:
Connect the electric radiator using the switch installed for this function. Before using your equipment
it is necessary to make some type of adjustment.
In its rst use, the transmitter has an internal battery, which must be charged for a minimum of 24
hours so that the programming is not lost. If the transmitter is disconnected, the time and day of the
last time before the disconnection will be saved (it does not count while it is o) unless it is connec-
ted to the Internet, which will be updated automatically.
NOTES:
To control the radiators through the APP, you need a Smartbox that connects the radiators to the
internet, using the router in the house. The APP will allow you to congure, program and access the
consumption statistics of the devices through an intuitive interface and with a simple operation (user
manual included with the Smartbox).

7
F. USE OF RADIATOR
Setting the radiator in programming mode, will allow you to assign temperatures at dierent times
of the day, for each day.
Understanding the full programing potential of your radiator will help to reduce energy consumption.
Display:
G. OPERATING INSTRUCTIONS
MODES:
The radiator can work at 3 dierent modes:
• Auto. The setpoint temperature varies automatically according to customizable programming
based on 3 temperatures (operation as programmable thermostat chronothermostat). The bars
report the temperature that is programmed for each hour.
• Manual.The setpoint temperature remains xed, depending on the user’s choice (operation as
digital thermostat).
• OFF. The radiator stays o.
Press “mode” to change the operation mode.
In “Manual” mode press the key [+] and [-] to change the temperature
In “Auto” mode when the temperature is modied temporarily, the change will be eective until the
next heating period or the end of the day.
In “Manual” mode the temperature will be xed.
Example:

8
ADJUST PROGRAMMED TEMPERATURES:
In “Auto” mode the temperature of each hour will change automatically following the programmed
Schedule. The user must assign to each hour one of the next temperatures mode:
• Comfort ( ), used normally when the user is at home.
• Eco or saving ( ), used at night or for brief absence periods.
• Freeze or minimum temperature ( ),used for longer absence periods.
To dene these temperatures:
• Press “Prog”, will display the right temperature.
• Select the temperature symbol using [+] or [-].
• Press “mode” to proceed.
• Select the temperature mode that you want to change the temperature to with the “mode” key.
Comfort ( ), eco ( ) o mínimum ( ).
• Change the temperature with the key [+] or [-].
• Press “mode” to modify other temperature modes or press “Prog” to exit.
SETTING PROGRAM, TIME AND DATE
The radiator allows the creation of a weekly programmed schedule assigning to each hour one of
the 3 available temperatures. The program for each day can be dierent.
• Use Comfort temperature for the hours that you are at home. (Represented by 2 bars at LCD).
• Use Eco-saving temperature for the night hours or short absence periods (Represented by 1 bar
at LCD).
• Use Freeze-minimum temperature for long absence periods. (Represented by no bar at LCD).
Press the “Prog” key for 3 seconds to start programming settings. You can switch directly to the day
and time setting by pressing “Prog” again.
(Example)

9
SETTING PROGRAM
1. The display will show 0:00 on day 1.
2. With the mode key select the desired “temperature mode” for that time (Comfort , eco o mí-
nimum ).
3. Use the [+] key to increase the value of the time until you get the value of the time you want to
change the “temperature mode”.
4. Use the “mode” key to select the desired new “temperature mode” for that time.
5. Repeat operations until 24:00 (0:00 on day 2)
6. Repeat the above steps for every day until 23:00 on day 7
7. Press the [+] key to switch to the time and day setting screen.
SETTING TIME AND DAY
Day:
7. On the screen the current day will be ashing, press [+] or [-] to modify it
8. Press “mode” to conrm the day.
Hour:
1. On the screen the current time will be ashing, press [+] or [-] to modify it.
2. Press “mode” to conrm the time.
3. On the screen the minutes will be ashing, press [+] or [-] to modify them.
4. Press “mode” to conrm the minutes and exit the time and day settings.
In case the device is already associated with a control unit, the time setting is cancelled and the time
of the control unit is automatically set.
KEYPAD LOCKING
Use this function to prevent any changes to your settings (In a child room, public area, etc...)
Press [+] and [-] for 3 seconds to lock, at the LCD the “Lock” message will appear:
Pres [+] and [-] for 3 seconds to unlock.

10
ADVANCED ADJUSTMENTS
To enter the advanced setting mode :
1. Press “Prog” while the radiator is in one of the main modes (OFF, AUTO, MANUAL).
The window shown will appear:
2. Press “Prog” for 5 seconds.
3. The advanced settings are:
• C1- Choose ºF or ºC
• C2- Choose type of control
• C3- Temperature Compensation
• C4- Firmware
• C5- Activation protection window open (turning o 30 minutes if a drop of 2.4 ° C is detected in 4
minutes), is indicated by the icon:
• C6- Adaptable heat anticipation. The radiator predicts the right moment to start heating in order
to reach the desired temperature according to the programmed schedule , so the user do not
need to take into account the time needed to heat the room.
• Maximum anticipation time: 24h. Indicated with the symbol:
• C7- ON / OFF Pilot thread activation.
4. To select one of the three advanced settings (C1 to C5) use the [+] / [-] keys.
5. Choose the required mode by pressing “mode.
6. Press [+] / [-] buttons to change.
7. Press “mode” or “Prog” to conrm and exit.
RESET RADIATOR
Press simultaneously “mode” and “Prog” for 10 seconds.
The gure appears:
Click on “mode” to conrm.
DEFAULT SETTINGS
• Mode: OFF
• Tª comfort: 19ºC
• Tª eco: 17ºC
• Tª freeze: 5ºC
• Tª mode manual: 19ºC
• Temperature compensation Oset: 0ºC
• No RF link
• Temperature units ºC
• Open window detection: OFF
• Control mode: PID -TRIAC-, PID15 -Relay-
• Program: All hours Eco

11
H. F.A.Q.
Error messages
• OC: no connection with temperature probe
• SC: Short-circuit at temperature probe
• Err1: Relay or Triac in short-circuit
• Err2: Overload (power limit exceeded)
• Err4: Temperature limit exceeded (>90ºC in the electronics)
I. ECO-DESIGN
Data Value
Item Simbol Unit 500W 750W 1.000W 1.200W 1.250W 1.500W 1.800W
Heat output
Nominal heat output Pnom kW 0,5 0,75 1,0 1,2 1,25 1,5 1,8
Minimum heat output (indicative) Pmin kW 0 0 0 0 0 0 0
Maximum continuous heat output Pmax,c kW 0,6 0,9 1,0 1,2 1,25 1,5 1,8
Auxiliary electricity consumption
At nominal heat output elmax kW 0,5 0,75 1,0 1,2 1,25 1,5 1,8
At minimum heat output elmin kW 0 0 0 0 0 0 0
In standby mode elSB kW 0,00095 0,00095 0,00095 0,00095 0,00095 0,00095 0,00095
Item Unit
Type of heat output/room temperature control (select one)
Single stage heat output and no room temperature control no
Two or more manual stages, no room temperature control no
With mechanic thermostat room temperature control no
With electronic room temperature control no
Electronic room temperature control plus day timer no
Electronic room temperature control plus week timer yes
Other control options (multiple selections possible)
Room temperature control, with presence detection no
Room temperature control, with open window detection yes
With distance control option yes
With adaptative start control yes
With working time limitation yes
With black bulb sensor no
Contact information: see back cover

Table of contents
Popular Heater manuals by other brands

L.B. White
L.B. White Workman CV225 Owner's manual and instructions

Trane
Trane GKNE ACCOMPANIMENT TO THE INSTALLATION, OPERATION AND MAINTENANCE MANUAL

STIEBEL ELTRON
STIEBEL ELTRON BHE 100 Style Operation and installation

comfort gear
comfort gear PPH10 User's manual and operating instructions

GVA
GVA GUFH2K15 instruction manual

WidTherm
WidTherm MPR 1000 Installation and maintenance instructions