POLA SC6D User manual

SC6D
SL 2.0
HANDBOOK
DECLARATION OF CONFORMITY
declares that your SC6D model is conform to following European
normatives: EN 50081-2 (1992) (Emission)
EN 50082-2 (1995) (Immunity)
Measure was performed by an
ACCREDITATED COMPETENT BODY.
and it is conform to directive EEC 72/23 and subsequent EEC 93/68 about
low voltage safety (LVD).
referredtodirectiveEE89/336andsubsequent92/31aboutelectro-magnetic
compatibility (EMC)
Limits for harmonic emission on line:
application of phase-control regulation in residential / light industry requires
obligation to inform electric company.
TECHNICAL DATA
ylppusrewoP egatloveniL caV042-022
ycneuqerF zH06/05
tenibaC lairetaM CVP
snoisnemiD mc11x22x71
thgieW 8.1GK
eergednoitcetorP 55PI
stuptuO daolrotalitnevmumixaM A6
daolrotalitnevmuminiM A4,0
daolstcatnocyalermumixaM 1CAA2
tuptuocigolanA Am1V01-0
stupnI egnargnirusaemeborP 0.511+...0.05-
C°
noisicerptnemurtsnI 2.0
C°
noisicerpgnidaereborperutarepmeT 2.0
C°
noitcennoceborP neercstuohtiweriw2
egnarerutarepmeT ytilibitarepO 04+...01-
C°
egarotS 58+...04-
C°
AsitcompanypolicytocontinuallyimprovetheproductstheManufacturers reserve
therighttomakeanymodificationstheretowithoutpriornotice.Theycannotbeheld
liable for any damage due to malfunction.
10.11.15

WIRING DIAGRAMS
IMPORTANT:
in order to avoid that
SC6D malfunction
causes damage to
animal's health we
suggest to install an
indipendent minimum-
maximum alarm system
(See our depliantl).
Ventilation slave
command (SCSL)
Fan
230V Max 6A*2
Ambient temperat.
probe *1
230V ac line
50/60 Hz + Earth
Make this connection only if
you want connect a SC6L
power unit option.
ALARM COMMAND
N.C. CONTACT
ALARM COMMAND
N.O. CONTACT
HEAT COMMAND
N.O. CONTACT
Contact open for alarm intervent
or black-out.
Contact closed for alarm intervent
or black-out.
Contact rating 2A AC1.
Use fuse max 2A T

VIEWING AMBIENT TEMPERATURE RECORDING
HEAT TEMPERATURE SETTING.
VENTILATION TEMPERATURE SETTING.
Press VENT (key lamp flashes) :
this message will be displayed instead of the
°C Ventilation temperature value.
Press +or -to modify, press VENT to confirm.
ALARM TEMPERATURE SETTING.
Press ALARM (key lamp flashes) :
this message will be displayed instead of the
°C Minimum alarm value.
Press +or -to modify, press ALARM to confirm.
At this point this message will be displayed instead of the
Maximum speed %.
Press +or -to modify, press VENT to exit.
At this point this message will be displayed instead of the
Minimum speed %.
Press +or -to modify, press VENT to confirm.
At this point this message will be displayed instead of the
°C Maximum alarm value
Press +or -to modify, press ALARM to exit.
RUN MODE
*1 Connection of probe doesn't require particular cabling attention (use normal commercial bipolar cable).
INSTALLATION
How to connect the auxiliary contacts:
Connect 41-42......43-44 terminals on the terminals block (contacts up to 2AMP.AC1)
to the loads as shows in the diagram.
Protect contacts with a 2AMP.F fuses.
How to connect temperature probe.
Connect the sensor provided as shown in the diagram: for remote connections use a
standard 0,5-square millimetre two-pole wire, taking great care over the connections,
by insulating and sealing carefully the joints.
In case of strong radio-interference insert a ferrite sleeve in the cable near regulator.
How to connect the power line.
Connect power line on L-N terminals, connect earth on PE terminal.
Protect against electric shocks by a line differential breaker.
SC6D istallation.
Place installation in a clean and dry site.
Connectelectricwiressuchasshownindiagram;useIP55cross-cablefornotdegrade
protection.
Inordertoavoiddamagetoregulatorduringdrillingispossibletoremovebasedprinted
circuit (fixed by 4 screws).
Fuse replacement.
Switch off line switch and replace with a 8A FF 6.3x32mm ceramic fuse.
Before switching on power line verify cause of over current.
Minimum speed setting.
To allineate setting of minimum speed to effective ventilator's minimum speed
(VENT key SP._ _ function) plug-off CNA connector on relay's circuit and adjust
MINIMUM trimmer to get minimum required speed.
Press HEAT (key lamp flashes) :
this message will be displayed instead of the
°C Heat temperature value.
Press +or -to modify, press HEAT to exit.
The light situated at the bottom of display shows the state of the controller.
STATE INDICATIONS LAMPS
In normal condition (not in programming) press VENT key for at least 1 second to display
% speed insert.
MIN/MAX
ALARM ON
HEAT
ON BAR-GRAPH % SPEED
VENTILATION INSERT
Press +: will be displayed followed by
°Maximum Temperature Recording .
Press - : will be displayed followed by
°Minimum Temperature Recording.
Valuesrecorderarememorypermanentstored:formemoryclearkeeppushed + keysformore
than 3 seconds: CLEA message will be composed on display before clearing operation.
*2 As a first step, check motors are suitable for triac speed control.
3-wire motor connection:
inthecaseofaspecial3-wiremotorproceedsuchasindicatedindiagram(thirdmotor'sconnector"Z"must
be connected to "N" terminal).
WithSCSLpowerunitispossibletoincreasetheregularcapacityfortotalload superior to 6A(every SC6L
has a capacity of 6A, it's possible to expand up to 5 SC6L).

Thesesettingsrefer tothe modeofoperationof the systemandmustbe madeon
initial start-up. Press - / + together for at least one second:
the message C.O.S.t. will be displayed.
Pressthan repeatly ALARM until interested variable'smessage is displayed (see
table below) : variable value and related message will be displayed.
Press + or - to set a new value and then ALARM to confirm.
The next system constant will then appear.
YoucanpressALARMforaleasttwosecond toescapeandreturntotheRunMode.
*3) You can correct the readings on the sensor (+ or -).
*2) tEnP =1 ; °C Temperature range.
*1) For more details see Operative Diagrams.
COST PROGRAMMING (System costants)
HEATINGOPERATIVEDIAGRAMS
AMBIENT PROBE TEMPERATURE
HEAT
ON
OFF
1/2 d.HEA 1/2 d.HEA
t.HEA
ALARMOPERATIVEDIAGRAMS
ON
OFF
t.AL.
MINIMUM ALARM
ON
OFF
MAXIMUM ALARM
t.AL.
d.HEA
tEnP =2 ; °F Temperature range.
In normal condition on display appears temperature.
Some special condition can cause following messages:
*In these cases alarm output relay is on.
SPECIAL MESSAGGES ON DISPLAY
*Whenselectedprobehas
an open circuit wire failure. *When selected probe has
a short circuit wire failure.
In some start-up conditions may be useful to work in "hand" mode.
Power off theprocessor, press + key and keep it pressed giving power on:
HAnd message will be displayed (release now + key).
Push + until is displayed number required to be handed:
1 = HEAT relay, 2 = Alarm relay.
Pushing again + for increase relay number previous relay is disactivated.
Youcan pressALARM for a least twoseconds toescape and returnto the Run Mode.
HAND MODE
At delivery this processor is ready programmed with the following (variable)
settings. To return to these settings at any time:
Powerofftheprocessor,pressALARMkeyandkeepitpressedgivingpoweron:
boot message will be displayed (release now ALARM key).
t.HEA = 20.0° t.vEn = 25.0° SP._ _= 0% SP.- - = 100%
t.AL._ = 10.0° t. AL. - =40.0 COST value are shown in COST paragraph.
PRESET PROGRAMS (bootstrap)
AMBIENT PROBE TEMPERATURE
Mess. Value Meaning Note
d.HEA 0.2° °HEAT differential *1)
ProP 3.0° °Ventilation proportional range *1)
FrEo =1 Power line frequency =1 ; 50Hz =2 ; 60Hz
tEnP =1 Temperature representation (=1 °C, =2 °F) *2)
Ad.tE 0.0° °Input sensor temperature correction (+ or -) *3)
VENTILATIONOPERATIVEDIAGRAMS
% Ventilation
ProP
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
AMBIENT PROBE TEMPERATURE
Minimum and maximum speed
are conditioned by these sets.
example with
SP._ _ =10%
example with
SP. - - = 90%
t.vEn