COOPERATION AND OPERATING RANGE
* 1-channel transmitters do not cooperate with roller blind controllers
CAUTION: The given range concerns open area - an ideal condition without any
natural or articial obstacles. If there are some obstacles between a transmitter
and a receiver, it is advisable to decrease the range according to: wood and plas-
ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium
and high electrical power lines, radio and television transmitters, GSM transmit-
ters set close to a device system have also a negative inuence on the range.
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m
lack* lack*
200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m
lack* lack*
200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
TIME PROGRAMMING
Press PROG push-button of ROP-01 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about 5 sec-
onds) till LED red diode switches on (rst signal pulsates, next the signal is constant).
Press PROG push-button of ROP-01 device and then release it. LED red diode
switches off and then switches on (signal pulsates). Every LED diode pulse equals
1 second.
After the adjusted time is nished (the number of LED red diode ashes) press
PROG push-button and then release it - TIME IS ADDED.
Maximum time is 18 hours.
RADIO TRANSMITTERS DELETION
Press PROG push-button of ROP-01 device for a longer time.
After 5 seconds LED red diode switches on (signal pulsates) and then it switches
off.
Release the push-button in ROP-01 - MEMORY IS DELETED.
CAUTION: Every transmitter can cooperate with ROP-01 in a different mode,
depending on how they were added to the device. One transmitter can be added
during one programming cycle. Full memory is signalled with pulsating LED red
diode.
WIRELESS CONTROL SET - LIGHTING
RZB-01
TECHNICAL DATA
RNK-02 ROP-01
Input (supply) terminals: - L, N
Input rated voltage: 3 V (battery CR2032) 230 V AC
Battery life: 3 ÷ 5 years -
Input voltage tolerance: - -15 ÷ +10 %
Nominal frequency: - 50 / 60 Hz
Nominal power consumption: - 0,29 W
Number of operation modes: - 5
Number of channels: 2 1
Transmission: radio 868,32 MHz
Transmission way: unidirectional
Coding: addressing transmission
Maximum number of transmitters: - 32
Range: up to 250 m in the open air up to 230 m in the open air
Time adjustment: - 1 с ÷ 18 hours (every second)
Optical signalling: LED red diode
Relay output clamps: - 12, 11, 14
Relay contacts parameters: - 1NO/NC 5A / 250V AC AC1
1250 VA
Number of terminal clamps: - 5
Section of connecting cables: - up to 2,5 mm
2
Ambient temperature range: -10 ÷ +55
o
C
Operating position: free
Casing mounting: wall plugs, double-sided
adhesive tape installation cable box Ø60 mm
Casing protection degree: IP20 (EN 60529)
Protection level: III II
Overvoltage category: - II
Pollution degree: 2
Surge voltage: - 1 kV (EN 61000-4-5)
Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm
Weight: 0,038 kg 0,043 kg
Reference standard: PN-ETSI EN 300 220-1
PN-ETSI EN 300 220-2
PN-EN 60669, PN-EN 60950
PN-EN 61000
OPERATION, MOUNTING RNK-02
OPERATION, MOUNTING ROP-01
CONNECTION
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-discon-
nector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special meas-
ure equipment.
Connect the cables with the terminals in accordance with the installing diagram.
Install ROP-01 device in installation cable box.
Switch on the power supply from the mains.
The device can operate in ve modes:
MONOSTABLE the relay operates only while pressing transmitter’s push-button.
BISTABLE (one push-button) the device changes relay status cyclically always after
pressing the same push-button.
SWITCH ON the device switches on after pressing the push-button.
SWITCH OFF the device switches off after pressing the push-button.
TIME the device switches off according to the adjusted time (tp), but it may be switched
off before adjusted time nishes. Default settings - 15 seconds.
CAUTION! Adjusted time can not be deleted.
By pressing the button, the transmitter sends a signal with 868,32 MHz frequency
which controls EXTA FREE receivers. Device programming procedure (adding a
transmitter to a receiver’s memory) is described in particular EXTA FREE man-
ual instructions. The device range (up to 250 m depending on a receiver) can be
increased by means of a retransmitter or few RTN-01 retransmitters.
The device can be mounted in any place by means of double-sided adhesive tape or
wall plugs 5 x (3 x 30) mm.
Mounting by means of wall plugs:
Remove the button - to do it press the button on one side, and on the other side put
a screwdriver into a slot and lift up the button (Fig. 1)
Find a place on the wall to mount the transmitter, make two holes corresponding
mounting holes from the transmitter’s base.
Set wall plugs in the holes.
Fix the base by means of screwing screws into wall plugs.
Place the button again.
BATTERY CHANGE
Battery discharge status is signalled by several LED red diode ashes during
transmission time.
Remove the button (Fig. 1).
By means of a screwdriver lever up the printedcircuit board releasing the bottom
latch (Fig. 2), and remove it from the base.
Remove the battery from the latch (Fig. 3).
Mount a new battery. Watch battery polarisation marked on the latch. Wrong battery
mounting may cause device damage.
Put the removed printed-circuit board back in the base.
Put the button back.
CAUTION: While changing the battery, it is suggested to press any of the but-
tons for about 5 seconds before putting it into a latch. Next press transmission
button several times to check its operation. If the transmitter does not work
properly repeat the battery change procedure.
RADIO TRANSMITTERS PROGRAMMING
MONOSTABLE mode:
Press transmitter’s push-button for a longer time.
Press PROG push-button of ROP-01 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button.
Release transmitter’s push-button. LED red diode switches on (rst signal pulsates,
next the signal is constant).
Press the same transmitter’s push-button and release it. LED red diode switches on
(the signal pulsates) and next it switches off - THE TRANSMITTER IS ADDED.
BISTABLE mode:
Press PROG push-button of ROP-01 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button.
Press the transmitter’s push-button for a longer time. LED red diode switches on (rst
signal pulsates, next the signal is constant).
Release transmitter’s push-button. LED red diode switches on (the signal pulsates),
next the LED red diode switches off - it means the TRANSMITTER IS ADDED.
SWITCH ON/SWITCH OFF mode (two push-buttons):
Press PROG push-button of ROP-01 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button.
Press and release transmitter’s pushbutton. LED red diode switches on (rst signal
pulsates, next the signal is constant).
Press and release the same transmitter’s push-button. LED red diode switches on
(the signal pulsates) and next it switches off - THE TRANSMITTER IS ADDED.
TIME mode (one push-button)
Press PROG push-button of ROP-01 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button.
Press and release transmitter’s pushbutton. LED red diode switches on (the signal
pulsates, next the signal is constant).
Press and release the same transmitter’s push-button. LED red diode switches on
(the signal pulsates) and next it switches off - THE TRANSMITTER IS ADDED.
An exemplary programming procedure with the use of P-257/2 remote controller.
The procedure for the rest of radio EXTA FREE transmitters is analogous.
Fig. 1
Fig. 2 Fig. 3

Other manuals for RNK-02

5

This manual suits for next models

2

Other Zamel Controllers manuals

Zamel Cet Ledix SLR-01 User manual

Zamel

Zamel Cet Ledix SLR-01 User manual

Zamel ROB-01 User manual

Zamel

Zamel ROB-01 User manual

Zamel RZB-03 User manual

Zamel

Zamel RZB-03 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel RTD-01 User manual

Zamel

Zamel RTD-01 User manual

Zamel exta life SRM-22 User manual

Zamel

Zamel exta life SRM-22 User manual

Zamel exta ZCM-22 Series User manual

Zamel

Zamel exta ZCM-22 Series User manual

Zamel GRM-10 User manual

Zamel

Zamel GRM-10 User manual

Zamel exta SRM-11 User manual

Zamel

Zamel exta SRM-11 User manual

Zamel exta SRP-01/M User manual

Zamel

Zamel exta SRP-01/M User manual

Zamel ledix SLR-11 User manual

Zamel

Zamel ledix SLR-11 User manual

Zamel Cet LediX SLR-11P User manual

Zamel

Zamel Cet LediX SLR-11P User manual

Zamel SRP-22 User manual

Zamel

Zamel SRP-22 User manual

Zamel Exta Free EFC-02 Mini User manual

Zamel

Zamel Exta Free EFC-02 Mini User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel SRP-02 User manual

Zamel

Zamel SRP-02 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel Exta Life EFC-01 User manual

Zamel

Zamel Exta Life EFC-01 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel Exta RTM-02 User manual

Zamel

Zamel Exta RTM-02 User manual

Zamel exita ZIM-12/08 User manual

Zamel

Zamel exita ZIM-12/08 User manual

Zamel SRP-03 User manual

Zamel

Zamel SRP-03 User manual

Zamel exta SRP-05 User manual

Zamel

Zamel exta SRP-05 User manual

Zamel Extra Free RZB-02 User manual

Zamel

Zamel Extra Free RZB-02 User manual

Popular Controllers manuals by other brands

Gamma Vacuum DIGITEL QPC instruction manual

Gamma Vacuum

Gamma Vacuum DIGITEL QPC instruction manual

Aerotech 6020HRJ user manual

Aerotech

Aerotech 6020HRJ user manual

Zmotion ZMC464 Hardware manual

Zmotion

Zmotion ZMC464 Hardware manual

StorageWorks RAID Array 410 installation guide

StorageWorks

StorageWorks RAID Array 410 installation guide

Azbil MY8045A Specifications & instructions

Azbil

Azbil MY8045A Specifications & instructions

Danfoss AMV213 operating instructions

Danfoss

Danfoss AMV213 operating instructions

Alcatel-Lucent OmniAccess SafeGuard installation guide

Alcatel-Lucent

Alcatel-Lucent OmniAccess SafeGuard installation guide

Nordson EFD ValveMate 7140 operating manual

Nordson EFD

Nordson EFD ValveMate 7140 operating manual

gefran 1200-RD00-00-0 Series quick start guide

gefran

gefran 1200-RD00-00-0 Series quick start guide

Honeywell R8182D Product data

Honeywell

Honeywell R8182D Product data

Toshiba TS3000 Series instruction manual

Toshiba

Toshiba TS3000 Series instruction manual

Azbil F4Q user manual

Azbil

Azbil F4Q user manual

LK Systems LK Webserver Assembly instructions

LK Systems

LK Systems LK Webserver Assembly instructions

ZEG-ENERGETYKA ATS-9 operating manual

ZEG-ENERGETYKA

ZEG-ENERGETYKA ATS-9 operating manual

Emerson Dixell XT141C Installing and operating instructions

Emerson

Emerson Dixell XT141C Installing and operating instructions

Rockwell Automation 1769-L30ER installation instructions

Rockwell Automation

Rockwell Automation 1769-L30ER installation instructions

Roland TU2-64 user manual

Roland

Roland TU2-64 user manual

Monicon GTR-85 owner's manual

Monicon

Monicon GTR-85 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.