Polaris DP-20 User manual

POLARIS DP-20
WEB GUIDE CONTROLLER
User Manual
1A
AUTOMATIC
× -ãããããÜÜÜÜÜ+
06-05-2007 © 2007 Fife Corporation. All rights reserved. Figure Sheet 1-862-D

06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D
THIS PAGE INTENTIONALY LEFT BLANK

DP-20 WEB GUIDE CONTROLLER USER MANUAL
i
COPYRIGHT
COPYRIGHT
All rights reserved. Any reproduction of this User Manual, in any form, in whole or in part,
requires the prior written consent of Fife Corporation.
The information given in this User Manual is subject to change without notice.
We have compiled this User Manual with the greatest possible care and attention; however, the
possibility of error can not be completely excluded. Fife Corporation accepts no legal liability for
incorrect information given and the consequences arising there from.
Copyright ©2007 Fife Corporation. All rights reserved.
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D
THIS PAGE INTENTIONALY LEFT BLANK

DP-20 WEB GUIDE CONTROLLER USER MANUAL
iii
TABLE OF CONTENTS
1 GENERAL INTRODUCTION 1-1
DP-20 General Information ............................................................................................1-1
2 OPERATOR INTERFACE 2-1
Function of the Operator Level Keys..............................................................................2-1
Features of the LCD Panel.............................................................................................2-2
3 SETUP MENU STRUCTURE 3-1
Setup Menu Notes .........................................................................................................3-1
Setup Menu Chart..........................................................................................................3-2
4 SYSTEM SETUP MENUS AVAILABLE FROM AUTOMATIC MODE 4-1
1X.1, System Gain.........................................................................................................4-1
1X.2, System Guide Point..............................................................................................4-1
1X.3, Measurement........................................................................................................4-2
5 SYSTEM SETUP MENUS AVAILABLE FROM SERVO-CENTER MODE 5-1
2X.1, Servo-Center Gain................................................................................................5-1
2X.2, Servo-Center Guide Point.....................................................................................5-1
2X.3, Measurement........................................................................................................5-2
6 SYSTEM SETUP MENUS AVAILABLE FROM MANUAL MODE 6-1
Basic Menus...................................................................................................................6-1
3X.1.1, System Gain ................................................................................................6-1
3X.1.2, System Guide Point.....................................................................................6-1
3X.1.3, Guide Polarity ..............................................................................................6-2
3X.1.4, Calibration, Edge Sensors...........................................................................6-3
3X.1.4, Calibration, Line Sensor, Center of Line Guiding.........................................6-4
3X.1.4, Calibration, Line Sensor, Edge of Line Guiding...........................................6-5
3X.1.4, Calibration, Servo-Center Sensor................................................................6-7
3X.1.5, Auto Setup...................................................................................................6-8
3X.1.6, Servo-Center Gain.......................................................................................6-9
3X.1.7, Servo-Center Polarity.................................................................................6-10
3X.1.8, Measurement.............................................................................................6-11
Special Menus..............................................................................................................6-12
3X.2.1, Deadband ..................................................................................................6-12
3X.2.2, Set Operation Mode Enable.......................................................................6-13
3X.2.3, Set Sensor Mode Enable, Edge Sensors ..................................................6-14
3X.2.3, Set Sensor Mode Enable, Line Sensor......................................................6-15
3X.2.4, Set Jog Enable...........................................................................................6-16
3X.2.5, Set Jog Polarity..........................................................................................6-17
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
iv
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D
3X.2.6, Set Jog Speed ...........................................................................................6-18
3X.2.7, Set Sensor Type........................................................................................6-19
Advanced Menus .........................................................................................................6-20
3X.3.1, Restore Settings ........................................................................................6-20
3X.3.2, Backup Settings.........................................................................................6-20
3X.3.3, Set Password, Enter Password .................................................................6-21
3X.3.3, Set Password, Delete Password................................................................6-22
3X.3.3, Set Password, Change Password .............................................................6-23
3X.3.4, Set Output A Delay....................................................................................6-24
3X.3.5, Set Output B Delay....................................................................................6-25
3X.3.6, Set Loss Of Null Output Range..................................................................6-26
3X.3.7, Digital I/O, Enable/Disable.........................................................................6-27
3X.3.8.1, Test Signals, Sensor Current..................................................................6-27
3X.3.8.2, Test Signals, Toggle Outputs..................................................................6-28
3X.3.8.3, Test Signals, Guide Test Mode...............................................................6-29
Language Menu...........................................................................................................6-31
3X.4.1, Select Language........................................................................................6-31
Custom Menus.............................................................................................................6-32
3X.5.1, ASC Control...............................................................................................6-32
3X.5.2, Set ASC Limits...........................................................................................6-33
3X.5.3, Set ASC Source.........................................................................................6-34
7 PARALLEL MATRIX 7-1
Parallel Input Matrix .......................................................................................................7-1
Parallel Output Matrix.....................................................................................................7-1
8 SYSTEM NOTES 8-1
9 TROUBLESHOOTING 9-1
Fault Diagnostics – Fault Rectification...........................................................................9-1
Fault Codes....................................................................................................................9-2
Return Shipment Instructions.........................................................................................9-3
Motor/Valve List .............................................................................................................9-4
10 SPECIFICATIONS 10-1
General ........................................................................................................................10-1
Certifications and Compatibility with Industrial Environments......................................10-2
Inputs and Outputs.......................................................................................................10-1
Maximum Cable Lengths .............................................................................................10-2

DP-20 WEB GUIDE CONTROLLER USER MANUAL
1
1-1
1 GENERAL INTRODUCTION
DP-20 General Information
The Polaris DP-20 Web Guide Controller is another Fife advancement in technology that
provides superior guiding performance.
This controller is able to operate in a variety of sensor modes, such as Fixed-Sensor Center
Guide or Edge Guiding from either edge. Edge of Line or Center of Line Guiding is also
supported.
The DP-20 can be either panel mounted or wall mounted (with optional mounting bracket).
The DP-20 Web Guide Controller is designed to control one motor, up to and including a 1.3
Amp motor, provided by Fife Corporation.
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D
THIS PAGE INTENTIONALY LEFT BLANK

DP-20 WEB GUIDE CONTROLLER USER MANUAL
2
2-1
2 OPERATOR INTERFACE
Function of the Operator Level Keys
AUTOMATIC This key initiates the Automatic mode. Correction is
applied to the web by moving the guide in response to the output of the
sensor(s) that has been selected.
SERVO-CENTER This key initiates the Servo-Center mode. The
guide is centered in its travel in response to the output of the Servo-
Center transducer (if installed).
MANUAL This key initiates the Manual mode. No correction is applied
to the guide. This key is also used to abort changes made in the Setup
Menus and to exit the Setup Menus.
SENSOR This key is used to select the sensor(s) to be used for
monitoring the web position when the system is in Automatic mode.
Sensor selection is allowed in Manual and Servo-Center modes only.
SETUP This key is used to enter the Setup Menus for configuring and
adjusting the guiding system.
- ARROW This key is used to jog the guide. The direction of guide
movement is configurable. This key is also used during setups to scroll
through the setup menus and to adjust setup parameters.
ENTER This key is not used at the Operator Level. It is used while in
the Setup Menus to enter the selected menu and to store modified
parameters.
+ ARROW This key is used to jog the guide. The direction of guide
movement is configurable. This key is also used during setups to scroll
through the setup menus and to adjust setup parameters.
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
2
2-2
Features of the LCD Panel
LINE 1 This line contains the menu number. This number may
contain 2 or more digits. The first digit indicates the current operation
mode. The second digit indicates the current sensor mode. The
subsequent digits indicate the current Setup Menu (when applicable).
See “SETUP MENU STRUCTURE“ for more information on the menu
number.
LINE 1 When the letter “X“ preceeds the menu number, this indicates
that the selected menu is password protected. When an attempt is
made to enter this menu, a password will be requested. The correct
password must be entered before access to this menu is allowed.
LINE 1 While in Servo-Center mode, the symbol of the current sensor
selection is displayed in this line.
LINE 1 While in the setup menus, the symbol of the current sensor
selection is displayed in this line.
LINE 1 A command present on the Digital I/O is indicated by an
asterisk in this line.
LINE 1 An External Lock command present on the Digitital I/O is
indicated by an asterisk surrounded by parentheses in this line.
LINE 1 An unrecognized command present on the parallel port is
indicated by a question mark in this line.
LINE 1 While in any of the setup menus, a flashing dot (see arrow) in
this line indicates that a timer is running. The DP-20 is waiting for a
response from the operator. If no response is detected in 3 minutes, the
unit will return to the Operator Level. If this dot is not flashing, no timer
is active.
× 3A.2.3.1
SETUP (MAN)
GUIDE POLARITY
+
× 2A
SERVO CENTER
~ƒ -ãããããÜÜÜÜÜ+
ר 2C.1.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
* 1A
AUTOMATIC
× -ãããããÜÜÜÜÜ+
× X3A.2.3.1
SETUP (MAN)
GUIDE POLARITY
+
(*) 1A
AUTOMATIC
× -ãããããÜÜÜÜÜ+
? 1A
AUTOMATIC
× -ãããããÜÜÜÜÜ+
ר 2C.1.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
2
2-3
LINE 2 While at the Operator Level, this line contains the name of
the currently selected Operation mode.
LINE 2 While in the setup menus, this line indicates that a Setup
Menu has been selected and also indicates the current Operation
Mode.
LINE 3 While at the Operator Level, in either Automatic or Manual
mode, this line contains the symbol for the current sensor mode and
also a bargraph indicating the signal level of the currently selected
sensor mode. The sensor symbols are: ×indicates Edge Left (X5 port);
Øindicates Edge Right (X4 port); ר indicates Center Guiding (both
edge sensors, X4 & X5 ports); ýindicates Center of Line guiding (X4
port); and Łindicates Edge of Line guiding (X4 port).
LINE 3 While at the Operator Level, in Servo-Center mode, this line
contains the Servo-Center sensor symbol (~ƒ) and also a bargraph
indicating the signal level of the Servo-Center sensor.
LINE 3 While in the Setup Menus, this line indicates the title of the
current menu selection.
LINE 4 While at the Operator Level, this line displays the Guide Point
value, if the value is not zero.
LINE 4 While at the Operator Level, in Automatic or Servo Center
mode, if ASC Control is set to ON, ASC is displayed on this line.
LINE 4 While at the Operator Level, in Automatic mode or Manual
mode, if ASC Control is set to ON, and if either one of the programmed
ASC Limits is reached, this line flashes ASC ACTIVE.
1A
AUTOMATIC
× -ãããããÜÜÜÜÜ+
× 3A.2.2
SETUP (MAN)
GUIDE POINT
-ÜÜÜÜåÜÜ+ +20.0%
1C
AUTOMATIC
ר -ãããããÜÜÜÜÜ+
× 2A
SERVO CENTER
~ƒ -ãããããÜÜÜÜÜ+
× 3A.1
SETUP (MAN)
GUIDE POINT
-ÜÜÜÜåÜÜ+ +20.0%
1A
AUTOMATIC
× -ãããããáÜÜÜÜ+
GP: +4.0%
1A
AUTOMATIC
× -ãããããáÜÜÜÜ+
ASC
1A
AUTOMATIC
× -ãããããáÜÜÜÜ+
ASC ACTIVE
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
2
2-4
LINE 4 While in the Setup Menus, this line indicates the value
associated with the menu as defined in Line 3. If it is possible to modify
the value, it will be flashing.
LINE 4 While at the Operator Level, in Automatic mode, Servo
Center mode, or Manual mode, if no motor is detected on the Drive
connector (X1), NO MOTOR is displayed on this line.
× 3A.2.2
SETUP (MAN)
GUIDE POINT
-ÜÜÜÜåÜÜ+ +20.0%
3A
MANUAL
× -ãããããáÜÜÜÜ+
NO MOTOR
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
3
3-1
3 SETUP MENU STRUCTURE
Setup Menu Notes
1. The SETUP key is used to enter the Setup Menus.
2. The ENTER key is used to store changes in the Setup Menus.
3. Pressing the MANUAL key in most Setup Menus will exit the Setup Menus and return to
the Operator Level. All changes that were not previously stored will be discarded.
4. In the Setup Menu Structure, at the end of each string of menu selections is an EXIT
MENUS screen. Pressing the ENTER key while this screen is displayed will exit the
Setup Menus and return to the Operator Level. No values or settings are stored.
5. While in most of the Setup Menus, if no key is pressed within 3 minutes, the system will
automatically exit the Setup Menus and return to the Operator Level. While in Automatic
Mode or Servo-Center Mode, the Gain and Guide Point changes are stored. While in
Manual Mode, all changes that were not previously stored are discarded.
6. While in the Setup Menus, if “FAILED“ is displayed, the MANUAL key must be pressed
to exit the Setup Menus and return to the Operator Level.
7. If a menu is password protected, the letter “X“ will be indicated to the left of the menu
number.
8. The Menu Number, located at the right end of line 1 of the LCD Panel, will contain 2 or
more digits with the second and subsequent digits separated by dots. The Menu Number
is defined as follows;
1A.2.3.4.5 MENU NUMBER
1 OPERATION MODE *
_A SENSOR MODE/INPUT **
__.2 MENU LEVEL
__._.3 MENU ITEM
__._._.4.5 MENU ITEM SETTINGS
* 1= Automatic, 2= Servo-Center, 3= Manual
** A= Edge Left, B= Edge Right, C= Center (both edges)
D= Line Center, E= Line Edge, F= Servo-Center.
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
3
3-2
Setup Menu Chart
AUTOMATIC MODE
1X.1 1X.2 1X.3 1X.4
Gain Guide Point Measurement Exit Menus
SERVO-CENTER MODE
2X.1 2X.2 2X.3 2X.4
Servo-Center
Gain Servo-Center
Guide Point Measurement Exit Menus
MANUAL MODE
SELECT MENU
3X.1 3X.2 3X.3 3X.4 3X.5 3X.6
BASIC SPECIAL ADVANCED LANGUAGE CUSTOM Exit Menus
BASIC MENUS
3X.1.1 3X.1.2 3X.1.3 3X.1.4 3X.1.5 3X.1.6 3X.1.7 3X.1.8 3X.1.9
Gain Guide Point
Guide
Polarity Calibration Auto Setup Servo-Center
Gain Servo-Center
Polarity Measurement Exit
Menus
SPECIAL MENUS
3X.2.1 3X.2.2 3X.2.3 3X.2.4 3X.2.5 3X.2.6 3X.2.7 3X.2.8
Deadband Set Operation
Mode Enable Set Sensor
Mode Enable Set Jog
Enable Set Jog
Polarity Set
Jog Speed Set
Sensor Type Exit Menus
ADVANCED MENUS
3X.3.1 3X.3.2 3X.3.3 3X.3.4 3X.3.5 3X.3.6 3X.3.7 3X.3.8 3X.3.9
Restore
Settings Backup
Settings Set
Password Set Output
A Delay Set Output
B Delay Loss of Null
Output Range Digital I/O
(X3) Test Signals Exit
Menus
LANGUAGE MENU
3X.4.1
Select
Language
CUSTOM MENUS
3X.5.1 3X.5.2 3X.5.3 3X.5.4
ASC Control Set ASC
Limits Set ASC
Source Exit Menus
MEASUREMENT SUBMENUS
1X.3.1
2X.3.1
3X.1.8.1
1X.3.2
2X.3.2
3X.1.8.2
1X.3.3
2X.3.3
3X.1.8.3
1X.3.4
2X.3.4
3X.1.8.4
1X.3.5
2X.3.5
3X.1.8.5
1X.3.6
2X.3.6
3X.1.8.6
1X.3.7
2X.3.7
3X.1.8.7
1X.3.8
2X.3.8
3X.1.8.8
1X.3.9
2X.3.9
3X.1.8.9
Sensor Signal
Edge L (X5) or
Line C (X4)
Sensor Signal
Edge R (X4) or
Line E (X4)
Sensor Signal
Servo-Center
(X2)
Tach
Signal Motor
Type Digital
Inputs Firmware
Version Serial
Number Exit
Menus
TEST SIGNALS SUBMENUS
3X.3.8.1 3X.3.8.2 3X.3.8.3 3X.3.8.4
Sensor
Current Toggle
Outputs Guide Test
Mode Exit
Menus
Notes:
1. The ‘X’ in the Menu Number may be A, B, C, D, or E, depending on the sensor mode.
2. The highlighted menus are, by default, password protected if a password has been set.
3. The text on the LCD Panel may vary slightly from the text in this chart.
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
4
4-1
4 SYSTEM SETUP MENUS
AVAILABLE FROM AUTOMATIC MODE
1X.1, System Gain
1. Press the SETUP key to enter the Setup
Menus. The GAIN menu will be displayed on
the LCD Panel.
2. Press the ENTER key to allow adjustment of
the System Gain. The current Gain Value will
begin flashing on line 4.
3. Use the ARROW keys to adjust the System
Gain to the desired level as indicated on line 4.
If an ARROW key is held down, the speed of
the Gain change increases. The change is
effective immediately, but not stored.
4. If desired, press both of the ARROW keys
simultaneously to reset the System Gain to
10.0% as indicated on line 4.
5. Press the ENTER key to store the change or
press the MANUAL key to abort the change.
The system will exit the setup menus, and
return to the Operator Level.
ר 1C.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
ר 1C.1.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
ר 1C.1.1
SETUP (AUTO)
GAIN
ããÜÜÜÜÜÜÜÜ 20.0%
ר 1C.1.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
1C
AUTOMATIC
ר -ãããããÜÜÜÜÜ+
1X.2, System Guide Point
1. Press the SETUP key to enter the Setup
Menus. The GAIN menu will be displayed on
the LCD Panel.
2. Use the ARROW keys to scroll until GUIDE
POINT is displayed on line 3.
ר 1C.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
ר 1C.2
SETUP (AUTO)
GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
4
4-2
3. Press the ENTER key to allow adjustment of
the System Guide Point. The current Guide
Point value will begin flashing on line 4.
4. Use the ARROW keys to adjust the System
Guide Point to the desired position. The LCD
Panel is scaled to ±100% from the center of the
sensor bandwidth. The default range of the
Guide Point adjustment is ±80% of the sensor
bandwidth, but this range will be limited if a
Deadband above 10% is being used. ASC
settings can also limit the Guide Point range.
The Guide Point change is effective
immediately, but not yet stored.
5. If desired, press both of the ARROW keys
simultaneously to reset the System Guide Point
to the center of the available range, as
indicated on line 4.
6. Press the ENTER key to store the change or
press the MANUAL key to abort the change.
The system will exit the setup menus, and
return to the Operator Level. The Guide Point
value (GP) will be displayed on Line 4 if the
value is not 0.
ר 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
ר 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜÜåÜÜ+ +20.0%
ר 1C.2.1
SETUP (AUTO)
GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
1C
AUTOMATIC
ר -ãããããáÜÜÜÜ+
GP: +20.0%
1X.3, Measurement
1. Press the SETUP key to enter the Setup
Menus. The GAIN menu will be displayed on
the LCD Panel.
2. Use the ARROW keys to scroll until
MEASUREMENT is displayed on line 3.
ר 1C.1
SETUP (AUTO)
GAIN
ãÜÜÜÜÜÜÜÜÜ 10.0%
ר 1C.3
SETUP (AUTO)
MEASUREMENT
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
4
4-3
3. Press the ENTER key to view the Measurement
menus. The level of the guiding signal from the
Left Edge Sensor (Line Center if a line sensor
is being used) is displayed on Line 4. This
signal has been scaled by values which were
determined during the Sensor Calibration
procedure.
4. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the Right
Edge Sensor (Line Edge if a line sensor is
being used). The guiding signal is displayed on
Line 4. This signal has been scaled by values
which were determined during the Sensor
Calibration procedure.
5. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
Servo-Center Sensor. The sensor signal is
displayed on Line 4.
6. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
TACHOMETER. The tachometer signal is
displayed on Line 4.
7. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
MOTOR TYPE. The motor type is displayed on
Line 4.
8. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
DIGITAL INPUTS. The status of the inputs is
displayed on Line 4. The order in which the
inputs are displayed is 5,4,3,2,1,0.
9. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
FIRMWARE VERSION. The version number of
the firmware is displayed on Line 4.
ר 1C.3.1
MEASUREMENT
× SENSOR (X5)
-ããããÜÜÜÜ+ 50%
ý 1D.3.1
MEASUREMENT
ý SENSOR (X4)
-ããããÜÜÜÜ+ 50%
Ł1E.3.2
MEASUREMENT
ŁSENSOR (X4)
-ããããÜÜÜÜ+ 50%
ר 1C.3.2
MEASUREMENT
Ø SENSOR (X4)
-ããããÜÜÜÜ+ 50%
ר 1C.3.3
MEASUREMENT
~ƒ SENSOR (X2)
-ããããÜÜÜÜ+ 50%
ר 1C.3.4
MEASUREMENT
TACHOMETER
-ããããÜÜÜÜ+ 0%
ר 1C.3.5
MEASUREMENT
MOTOR TYPE
1.3A MOTOR 14K
ר 1C.3.6
MEASUREMENT
DIGITAL INPUTS
000000
ר 1C.3.7
MEASUREMENT
FIRMWARE VERSION
DP-20 Ver 1.00
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
4
4-4
10. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the
SERIAL NUMBER. The serial number of the
DP-20 is displayed on Line 4.
11. If desired, use the ARROW keys to scroll until
EXIT MENUS is displayed on line 3. Pressing
the ENTER key while this screen is displayed
will exit the Measurement Menus and return to
the Operator Level.
12. Otherwise, press the MANUAL key to exit the
Measurement Menus and return to the
Operator Level.
ר 1C.3.8
MEASUREMENT
SERIAL NUMBER
SN:10000
ר 1C.3.9
MEASUREMENT
EXIT MENUS
1C
AUTOMATIC
ר -ãããããÜÜÜÜÜ+
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
5
5-1
5 SYSTEM SETUP MENUS
AVAILABLE FROM SERVO-CENTER MODE
2X.1, Servo-Center Gain
1. Press the SETUP key to enter the Setup
Menus. The Servo-Center (~ƒ) GAIN menu will
be displayed on the LCD Panel.
2. Press the ENTER key to allow adjustment of
the Servo-Center Gain. The Gain value will
begin flashing on line 4.
3. Use the ARROW keys to adjust the Gain to the
desired level as indicated on line 4. If an
ARROW key is held down, the speed of the
Gain change increases. The change is effective
immediately, but not stored.
4. If desired, press both of the ARROW keys
simultaneously to reset the Servo-Center Gain
to 5.0% as indicated on line 4.
5. Press the ENTER key to store the change or
press the MANUAL key to abort the change.
The system will exit the setup menus, and
return to the Operator Level.
× 2A.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
× 2A.1.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
× 2A.1.1
SETUP (SC)
~ƒ GAIN
ããÜÜÜÜÜÜÜÜ 15.0%
× 2A.1.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
× 2A
SERVO-CENTER
~ƒ -ãããããÜÜÜÜÜ+
2X.2, Servo-Center Guide Point
1. Press the SETUP key to enter the Setup
Menus. The Servo-Center (~ƒ) GAIN menu will
be displayed on the LCD Panel.
2. Use the ARROW keys to scroll until ~ƒ GUIDE
POINT is displayed on line 3.
3. Press the ENTER key to allow adjustment of
the Servo-Center Guide Point. The Guide Point
value will begin flashing on line 4.
ר 2C.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
ר 2C.2
SETUP (SC)
~ƒ GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
ר 2C.2.1
SETUP (SC)
~ƒ GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D

DP-20 WEB GUIDE CONTROLLER USER MANUAL
5
5-2
4. Use the ARROW keys to adjust the SC Guide
Point to the desired position as indicated on
line 4.
5. If desired, press both of the ARROW keys
simultaneously to reset the Servo-Center Guide
Point to 0.0% as indicated on line 4.
6. Press the ENTER key to store the change or
press the MANUAL key to abort the change.
The system will exit the setup menus, and
return to the Operator Level. The Servo-Center
Guide Point value will be displayed on Line 4 if
the value is not 0.
ר 2C.2.1
SETUP (SC)
~ƒ GUIDE POINT
-ÜÜåÜÜÜÜ+ -21.0%
ר 2C.2.1
SETUP (SC)
~ƒ GUIDE POINT
-ÜÜÜåÜÜÜ+ 0.0%
ר 2C
SERVO-CENTER
~ƒ -ããããÜÜÜÜÜÜ+
~ƒ GP: -21.0%
2X.3, Measurement
1. Press the SETUP key to enter the Setup
Menus. The SC GAIN menu will be displayed
on the LCD Panel.
2. Use the ARROW keys to scroll until
MEASUREMENT is displayed on line 3.
3. Press the ENTER key to view the
Measurement menus. The level of the guiding
signal from the Left Edge Sensor (Line Center
if a line sensor is being used) is displayed on
Line 4. This signal has been scaled by values
which were determined during the Sensor
Calibration procedure.
4. Use the ARROW keys to scroll to the desired
Measurement menu. Next in the list is the Right
Edge Sensor (Line Edge if a line sensor is
being used). The guiding signal is displayed on
Line 4. This signal has been scaled by values
which were determined during the Sensor
Calibration procedure.
ר 2C.1
SETUP (SC)
~ƒ GAIN
ãÜÜÜÜÜÜÜÜÜ 5.0%
ר 2C.3
SETUP (SC)
MEASUREMENT
ר 2C.3.1
MEASUREMENT
× SENSOR (X5)
-ããããÜÜÜÜ+ 50%
ý 2D.3.1
MEASUREMENT
ý SENSOR (X4)
-ããããÜÜÜÜ+ 50%
ר 2C.3.2
MEASUREMENT
Ø SENSOR (X4)
-ããããÜÜÜÜ+ 50%
Ł2E.3.2
MEASUREMENT
ŁSENSOR (X4)
-ããããÜÜÜÜ+ 50%
06-05-2007 DP-20 WEB GUIDE CONTROLLER Figure Sheet 1-862-D
Other manuals for DP-20
1
Table of contents
Other Polaris Controllers manuals
Popular Controllers manuals by other brands

Purmo
Purmo Master 6 zones user guide

Precision Digital Corporation
Precision Digital Corporation ProtEX-MAX PD8-6210 quick start guide

NANOTEC ELECTRONIC
NANOTEC ELECTRONIC N5 Technical manual

Segway
Segway InfoKey installation instructions

Sony
Sony RM-NS1000 user guide

Altronix
Altronix Trove1R installation guide