manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PowerTech
  6. •
  7. Inverter
  8. •
  9. PowerTech MP-3750 User manual

PowerTech MP-3750 User manual

1 2
Solar Charge Controller with 2 USB Outlets
MP-3750, MP-3752
User Manual
1. Safety Information
Read all of the instructions in the manual before installation.
DO NOT disassemble or attempt to repair the controller.
Install external fuse or breaker as required.
Do disconnect the solar module and fuse/ breakers near to battery before
installing or moving the controller.
Power connections must remain tight to avoid excessive heating from a
loose connection.
Only charge batteries that comply with the parameters of controller.
Battery connection may be wired to one battery or a bank of batteries.
Risk of electric shock, the PV and load can produce high voltages when the
controller is working.
2. Overview
PWM charge controller with USB output that adopts the most advanced digital
technique. It’s an easy operation and cost efficient controller featured as:
3-Stage intelligent PWM charging:Bulk, Boost/Equalize, Float
Support 3 charging options: Sealed, Gel, and Flooded
Battery status LED indicator can indicates battery situation
Battery temperature compensation function
The USB will provide power supply that can charge for electronic equipment
Battery type and load output can be set via button
Extensive Electronic protection
3. Product Features
①
Mounting Hole Φ4.5
⑥
Button
②
PV Terminals
⑦
Battery status LED indicator
③
Battery Terminals
⑧
Load status LED indicator
④
Load Terminals
⑨
Charging status LED indicator
⑤
USB Output Port
4. Wiring
(1) Connect components to the charge controller in the sequence as shown
below and pay much attention to the “+” and “-”. Please don’t insert the fuse or
turn on the breaker during the installation.
(2) After power on the controller, check the Battery LED indicator on the
controller, it will be on solid green. Otherwise please refer to chapter 8.
Always connect the battery first, in order to allow the controller to recognize
the system voltage.
(3) The battery fuse should be installed as close to battery as possible. The
suggested distance is within 150mm.
5. LED Indicators
1) Charging and load status indicator
Indicator
Color
Status
Instruction
Charging status
LED indicator
Green
On Solid
In Charging
Green
OFF
No Charging
Green
Fast Flashing
Battery Over
Voltage
Load status LED
indicator
Green
On Solid
Load ON
Green
OFF
Load OFF
Green
Slowly Flashing
Load over load
Green
Fast Flashing
Load short circuit
2) Battery status indicator
LED1
LED2
LED3
LED4
Battery Status
Slowly Flashing
×
×
×
Under voltage
Fast Flashing
×
×
×
Over discharge
Battery LED indicator status during voltage is up
○
○
×
×
12.8V<Ubat<13.4V
○
○
○
×
13.4V<Ubat<14.1V
○
○
○
○
14.1V <Ubat
Battery LED indicator status during voltage is down
○
○
○
×
12.8V<Ubat<13.4V
○
○
×
×
12.4V<Ubat<12.8V
○
×
×
×
Ubat<12.4V
NOTE:
①Voltage value for 12V system at 25℃, please use 2×in 24V system ;
②"○"LED indicator on; "×"LED indicator off.
6. Setting Operation
1)Load ON/OFF Setting
When the controller is powered on, press the button to control the load
output.
NOTE: The USB will output when the load is on.
2)Battery Type Setting
Operation:
Step 1: Enter setting mode by pressing button for 5s until the battery status
LEDs are flashing.
Step 2: Select the desired mode by pressing button.
Step 3: The mode will be saved automatically without any operation for 5S and
LED will stop flashing.
Battery Type Indicator
LED1
LED2
LED3
Battery type
○
×
×
Sealed(Default)
○
○
×
Gel
○
○
○
Flooded
NOTE: "○"LED indicator on "×"LED indicator off
Figure 1 Product Feature
Figure 2 Connection diagram
④
①
⑤
⑥
⑦
⑧
⑨
②
③
LED1
LED2
LED3
LED4
3 4
7. Protection
Battery Over Voltage Protection
When the battery voltage reaches to the set point of Over Voltage
Disconnect Voltage(OVD), the controller will stop charging the battery to
protect the battery from being over charged to break down.
Battery Over Discharge Protection
When the battery voltage reaches to the set point of Low Voltage
Disconnect Voltage(LVD), the controller will stop discharging the battery to
protect the battery from being over discharged.
Load Overload Protection
Load will be switched off when 1.25 times rated current overload happens.
User has to reduce load appliance, then press the button or repower the
controller.
Load Short Circuit Protection
Load will be switched off when load short circuit (≥3 times rated current)
happens. User has to clear short circuit, then press the button or repower
the controller.
High Voltage Transients Protection
The controller is protected against small high voltage transients. In lightning
prone areas, additional external suppression is recommended.
8. Troubleshooting
Faults
Possible reasons
Troubleshooting
LED Charging
indicator turn off
during daytime
when sunshine falls
on PV modules
properly
PV array
disconnection
Confirm that PV and battery
wire connections are correct
and tight
No LED indicator
Battery voltage
maybe less than 8V
Measure battery voltage with
the multi-meter. Min.8V can
start up the controller
Charging status
LED indicator Fast
flashing
Battery Over
Voltage
Check if battery voltage is
higher than OVD, and
disconnect the PV
LED1 Fast flashing
Battery
over discharged
When the battery voltage is
restored to or above LVR point
(low voltage reconnect
voltage), the load will recover
Load status LED
indicator slowly
flashing
Load over load①
①Please reduce the number of
electric equipments .
②Press the button or repower
the controller.
Load status LED
indicator fast
flashing
Load short circuit
①Check carefully loads
connection, clear the fault.
②Press the button or repower
the controller.
①When load current reaches1.25 times 1.5 times and 2 times 1.35-1.5 times
more than nominal value, the controller will automatically turn off loads in 60s,
5s and 1s respectively.
9. Technical Specifications
Item
MP-3750
MP-3752
Nominal system voltage
12/24VDC Auto
Rated charge current
10A
20A
Rated discharge current
10A
20A
Battery input voltage range
8V~32V
Max. PV open circuit voltage
50V
Self-consumption
12V≤5mA; 24V≤7mA
Charge Circuit Voltage Drop
≤0.13V
Discharge Circuit Voltage Drop
≤0.17V
Temperature compensation
coefficient
-5mV/ ºC /2V
USB Output Port
5VDC/1.2A
Working environment
temperature
-35 ºC ~+55 ºC
Humidity
≤95% N.C.
Enclosure
IP20
Grounding
Common Positive
Overall dimension
120.3x67x
21.8mm
148x85.6x
34.8mm
Mounting dimension
111.5mm
138mm
Mounting hole size
Φ4.5
Terminals
12AWG/4mm2
10AWG /6mm2
Net weight
0.10kg
0.18kg
Battery Voltage Control Parameters
Below parameters are in 12V system at 25 ºC, please double the values in
24V system
Battery Type
Sealed
Gel
Flooded
Over Voltage Disconnect Voltage
16.0V
16.0V
16.0V
Charging Limit Voltage
15.0V
15.0V
15.0V
Over Voltage Reconnect Voltage
15.0V
15.0V
15.0V
Equalize Charging Voltage
14.6V
——
14.8V
Boost Charging Voltage
14.4V
14.2V
14.6V
Float Charging Voltage
13.8V
13.8V
13.8V
Boost Reconnect Charging Voltage
13.2V
13.2V
13.2V
Low Voltage Reconnect Voltage
12.6V
12.6V
12.6V
Under Voltage Warning Reconnect
Voltage
12.2V
12.2V
12.2V
Under Voltage Warning Voltage
12.0V
12.0V
12.0V
Low Voltage Disconnect Voltage
11.1V
11.1V
11.1V
Discharging Limit Voltage
10.6V
10.6V
10.6V
Equalize Duration
120 min.
——
120 min.
Boost Duration
120 min.
120 min.
120 min.
10. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV or load current, voltage or power exceeding the rated value of controller.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
11. Package Contents
MP-3750 / MP-3752 charge controller
User manual
Distributed by:
TechBrands by Electus Distribution Pty. Ltd.
320 Victoria Rd, Rydalmere
NSW 2116 Australia
Ph: 1300 738 555
Int’l: +61 2 8832 3200
Fax: 1300 738 500
www.techbrands.com
Made in China
Any changes without prior notice! Version number:V1.8

This manual suits for next models

1

Other PowerTech Inverter manuals

PowerTech MI5740 User manual

PowerTech

PowerTech MI5740 User manual

PowerTech MI-5085 User manual

PowerTech

PowerTech MI-5085 User manual

PowerTech MI-5180 User manual

PowerTech

PowerTech MI-5180 User manual

PowerTech MI5700 User manual

PowerTech

PowerTech MI5700 User manual

PowerTech MB3697 User manual

PowerTech

PowerTech MB3697 User manual

PowerTech MI5722 User manual

PowerTech

PowerTech MI5722 User manual

PowerTech MI5736 User manual

PowerTech

PowerTech MI5736 User manual

Popular Inverter manuals by other brands

Hyundai HY300SEI user manual

Hyundai

Hyundai HY300SEI user manual

Steren PS-723 instruction manual

Steren

Steren PS-723 instruction manual

Goodwe SS SERIES user manual

Goodwe

Goodwe SS SERIES user manual

Fimer UNO-DM 1.2-TL-PLUS-Q product manual

Fimer

Fimer UNO-DM 1.2-TL-PLUS-Q product manual

EZM FG-100 manual

EZM

EZM FG-100 manual

Nedap PowerRouter PR50S user manual

Nedap

Nedap PowerRouter PR50S user manual

Must PV1100 PLUS 1200VA user manual

Must

Must PV1100 PLUS 1200VA user manual

INVT Goodrive170-PV Series Operation manual

INVT

INVT Goodrive170-PV Series Operation manual

Defort DCI-300D user manual

Defort

Defort DCI-300D user manual

Gree GMV-Pdhm280W/Na-M Installation and operating instruction manual

Gree

Gree GMV-Pdhm280W/Na-M Installation and operating instruction manual

Power Sentry EAC ISSM 375 SM instruction manual

Power Sentry

Power Sentry EAC ISSM 375 SM instruction manual

Srne IU Series user manual

Srne

Srne IU Series user manual

INVT iMars BG6KTR Operation manual

INVT

INVT iMars BG6KTR Operation manual

Mitsubishi Electric FR-S540E-0.4K-EC instruction manual

Mitsubishi Electric

Mitsubishi Electric FR-S540E-0.4K-EC instruction manual

Olimpia splendid Maestro Pro 01925 manual

Olimpia splendid

Olimpia splendid Maestro Pro 01925 manual

Phocos Any-Grid PSW-H-5kW-230/48V Recommended Battery Settings Guide

Phocos

Phocos Any-Grid PSW-H-5kW-230/48V Recommended Battery Settings Guide

AERMEC FCLI 32 Technical manual

AERMEC

AERMEC FCLI 32 Technical manual

Tektronix SPG600 Quick reference manual

Tektronix

Tektronix SPG600 Quick reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.